My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7130 HIGHLAND DR 2022-02-14
>
Address Records
>
HIGHLAND DR
>
7130
>
7130 HIGHLAND DR 2022-02-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2022 3:10:36 PM
Creation date
11/9/2021 11:54:08 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND DR
Street Number
7130
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Z ., City of Sammamish A Residential Energy & Ventilation Complian0orm Page 6_of� <br />Whole House Ventilation (Prescriptive) IRC Sec. M1507.3 Whole -House Ventilation <br />Whole -house mechanical ventilation systems shall be designed in accordance with Sections M1507.3.1 through M1507.3.7. <br />Please check the appropriate box to describe which of the four prescriptive Whole House <br />Ventilation Systems you will be using. <br />Indicate ❑ Continuous or 01ritermittent and provide Run Time % 5 (see Table M1507.3.3(2)) <br />❑ 1. Whole House Ventilation Using Exhaust Fans & Outdoor Air Inlets or Operable Windows. (M1507.3.4) <br />2. Whole House Ventilation Integrated with a Forced Air System. (M1507.3.5) <br />❑ 3. Whole House Ventilation using a Supply Fan. (M1507.3.6) <br />TABLES FOR USE WITH CALCULATING WHOLE HOUSE VENTILATION OPTIONS <br />TABLE M1507.3.3( t <br />CONTINUOUS WHOLE -HOUSE MECHANICAL'vENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS <br />DWELLING UNIT <br />FLOOR AREA <br />(Square fart <br />NURIBER OF IEDROO S <br />0-1 2-3 4-8 g—q >7 <br />AIrftw In CFM <br />i < 1,500 ' <br />30 <br />45 <br />60 <br />75 <br />90 <br />1,501— 3,000 <br />45 <br />60 <br />75 <br />90 <br />105 <br />3,001— 4,500 <br />60 <br />75 <br />90 <br />105 <br />120 <br />4,501— 6,(100 <br />75 <br />90 <br />105 <br />120 <br />135 <br />6,001— 7,500 <br />90 <br />105 <br />120 <br />135 <br />150 <br />> 7,500 <br />105 <br />120 <br />135 <br />150 <br />165 <br />For SI: 1 square foot = 0.0929'ne, 1 cubic foot per minute = 0.00047I9 els. <br />TABLE M1507.3 2) <br />INTERMITTENT WHOLE -HOUSE MECHANICAL VENTILATION RATE FACTOWb <br />RUN-TIME PERCENTAGE 1N EACH 444OUR <br />26% <br />=% <br />W% <br />66 % <br />73% <br />1009E <br />SEGMENT <br />Factoe <br />4 <br />3 <br />2 <br />1.5 <br />1.3 <br />1 1.0 <br />a. For ventilation system run time values between those ,given, the factors are permitted to be determined by interpolation: , <br />b. Extrapolation beyond the table is prohibited. <br />See modified Tables M1507.3.3(1) implementing intermittent factors shown in <br />Table M1507.3.3(2)—on next page. <br />Supp Fan Tested at 0.40" W.G. <br />Specified Volume from <br />Table M1507.3.3 1 <br />Minimum Smooth Duct <br />Diameter <br />Minimum Flexible <br />Duct Diameter <br />50 — 90 CFM <br />4 inch <br />5 inch <br />90 -150 CFM <br />5 inch <br />6 inch <br />150 — 250 CFM <br />6 inch <br />7 inch <br />250 — 400 CFM <br />7 inch <br />8 inch <br />Source Specific Exhaust Ventilation <br />Required in each kitchen, bathroom, water closet compartment, laundry room, indoor swimming pool, spa and other <br />rooms where water vapor or cooking odor is produced. <br />MINIMUM REQUIRED LOCAL EXHAUST RATES FOR <br />ONE- AND TWO-FAMILY DWELLINGS <br />AREA TO 13E EXHAUSTED I EXHAUST RATES <br />x4e4%pne 100 chn intermittent or 25 cfin cont <br />in- <br />Bathrooms-Toilet Rooms Mechanical exhaust capacity of 50 cfm <br />I intermittent or 20 cfm continuous <br />For Si I cubic foot per minute = 0.0OD4719 rn'A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.