Laserfiche WebLink
ELECTR 'ALP, <br />DIRECTIONS: Read the WAC section below to determine if plan review is required or not required. Then select the box next to (a) to <br />tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-4613-900. If plan review is <br />required, select the box next to (b) and (c) to acknowledge that plan review is required and the electrical plans have been provided <br />with this permit application. <br />* If item (a)-(ii, iii, or v) is selected, the work must also comply with section (a)-(vii). See arrow flow chart below. <br />(3) Electrical plan review. <br />® (a) Electrical plan review is not required for: <br />❑ (i) Low voltage systems; <br />I*--❑ (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br />❑ (iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br />involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br />(iv) Stand-alone utility fed services that do not exceed 250 volts, 400 amperes where the project's distribution system <br />❑ does not include: <br />(A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br />(B) An essential electrical system defined in NEC 517.2; or <br />(C) A required fire pump system. <br />(v) Modifications to existing electrical installations where all of the following conditions are met: <br />(A) Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br />250 volts or for lighting circuits not exceeding 277 volts to ground; <br />(B) Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br />(C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br />and <br />(D) Service or feeder load calculations are increased by 5% or less. <br />(vi) Electric power production source(s) such as solar photovoltaic, fuel cell, or wind electric system(s) with a total <br />❑ rating of 9600 watts or less. <br />(vii) For installations in (a)(ii), (iii), and (v) of this subsection to be considered, the following must be available' <br />❑ to the electrical inspector before the work is initiated: <br />(A) A clear and adequate description of the project's scope; <br />(B) A load calculation(s); <br />(C) What the load changes are, providing both before and after panel schedules as needed; and <br />(D) Provide information showing that the service and feeder(s) supplying the panel(s) where the work is <br />taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br />for that supply. <br />NOTE: Electrical plan review is not required for "Medical, dental, and chiropractic clinic" of which is a clinic or <br />❑ physicians' office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br />(1)(c)(xii). <br />(b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br />El occupancies defined in this chapter. <br />® (c) If a review is required, the electrical plan must be submitted for review and approval before the electrical work is begun. <br />T ble 900-1 <br />Healtkor 0,grsonarCare P.adi lfies <br />Health or Persorial Care FacFiity <br />.-.... Type .. <br />Dian; Review <br />Required . <br />t-ios ta`:. <br />Yes <br />a8ur nn Fcffie'un or long crib <br />CA <br />ye's <br />boarding home <br />Yes <br />F gist=� { 'ingfacr;ity� <br />'Yes <br />private a€coholism hospl t <br />Yes <br />Pnva.[ psfcn•acrct}osp at <br />Yes <br />Matern>bj-home <br />Yes <br />Ambu-a ory'su?ge acimv <br />Yes <br />Rerra hcmodiafsis. clinic <br />Yes <br />Resgentf Itreatn�entfaci?izy <br />yes <br />Enhanced service facility.. <br />yes- <br />Adult:residentia: r h-bil taflbj <br />Genie;: <br />Yes <br />Tatte 908,z <br />Educational and ,lmtit f6nal 4<aciiities,, laces of csseiiibly, or tither 6acilities. <br />Educatiotrai: ln. $Vt4tianal,, Or <br />Other. Fae ity Types: <br />Plan Rev eW <br />Required <br />➢nstrtu#:¢naG <br />Yes: <br />i�intesstu Tahtes_rSCi£s 7.�id 9QEF�2,, <br />r cit}at thcrtp.to do'eiectritat nsp cttr�r= <br />tndy requ.ir e plan, Y.6drew L,n faci;ity types not <br />revieEd'b} # ieiepartmenf. <br />PERMIT <br />Page 2-Plan Review <br />