Laserfiche WebLink
=90 July 19, 2019 <br />M2190708 Asbesto-Test, Inc. 425-489-4040 <br />Vacant Duplex 6D 3205 Lombard Ave. Everett, WA 98201 <br />Samples taken are listed with their corresponding analyses. If asbestos is detected, those samples containing asbestos are listed first <br />and noted with the initials 'ACM". <br />Some sample analyses listed may be a representative analysis of individual and separate samplings and analysis of homogenous <br />materials, as prescribed byA.H.E.R.A. guideline. <br />If, during demolition or renovation, any additional suspect asbestos containing materials are located [may include but not limited to: <br />sheet vinyl flooring, the flooring, wall or ceiling texturings or paints, concrete siding or skirting, cement pipes, cement wallboard, <br />electrical cloth, electrical wiring insulation, thermal paper, wallboard, joint compounds, vinyl wall coverings, spackling compounds, or <br />any other suspect TSI (Thermal System Insulation)], those materials are presumed Asbestos Containing Materials unless determined <br />to be non -asbestos by laboratory analysis. <br />Asbesto-Test, Inc. does not guarantee approximations of quantities of ACM, which may be listed with the analyses. It is therefore <br />recommended professional abatement price and/or disposal quotes be obtained by inquiring as to fees per area of specific ACM <br />material (i.e. sq. ft, , In. ft etc.), or by on site assessment. <br />Any and all materials identified as ACM and/or PACM in this report must be abated prior to disturbance in renovation or demolition. <br />PLM (polarized light microscopy) has been known to miss asbestos in small percentages of some samples, which contain asbestos, <br />thus negative PLM results cannot be guaranteed. Floor tiles and wipes should be tested with SEM (scanning electron microscope) or <br />TEM (transmitting electron microscope), to insure analytical accuracy when asbestos is reported in small percentages <br />Analytical test method: USEPA 600/R93/116** (PLM); WAC 296-62-07753 App. J <br />**One percent is the USEPA regulatory limit for asbestos in bulk samples. <br />Kev., "FRIABLE" signifies "EasilyAirborne" <br />ACM signifies "Asbestos Containing Material" <br />PACM signifies "Presumed Asbestos Containing Materiar <br />CAB signifies "Concrete Asbestos Board" <br />t signifies "less than" <br />TSI signifies "Thermal System Insulation" <br />HVAC signifies Heating Ventilating Air -Conditioning" <br />NAD signifies No Asbestos Detected" <br />END OF REPORT <br />ArLynn Hammond, Pres., BSc. <br />Analytical Chemist, AIHA proficient <br />Inspector, certified A.H.E.R.A. <br />accred#174014; exp. July 17, 2020 <br />BBB_ <br />CD <br />1429Ave. D. 9187, Snohomish, WA 98290 <br />425-489-4040; f 775-665-0420 <br />www.asbestotest.com; infoaasbtestotest.com <br />