6/8/2021 City of Everett <br />1i19:49PRI <br />INSPECTION ACTIVITY REPORT <br />Permit No. C1908-021 Site Address 7037 MORGAN RD <br />Page <br />Applied 8/30/2019 Applicant ALMOND DOUGLAS Lot <br />Approved 5/11/2020 Owner DINSA GEDEFA & GELETA BEDANE L Block <br />Issued 5/18/2020 Contractor EVERGREEN CONTRACTING Tract <br />Parent Permit No. Description ADDITION OF (3) BEDROOMS FOR AFH/ RECONFIGURE BAI <br />Notes ADA REQUIREMENTS**FINAL LANDSCAPE INPECTION REQUIRED**LANDSCAPING SHALL <br />BE RESTORED TO MEET SHORT PLAT CONDITIONS**SETBACK SURVEY REQUIRED** <br />Scheduled <br />ComDleted <br />TvDe <br />Insuector <br />Result <br />Remarks <br />Inspector's Comments <br />6/l/2020 <br />6/l/2020 <br />BLDG <br />KMK <br />APPROVAL <br />eTRAKiT Inspection <br />5/28/2020 1:43 PM john an <br />02-FOOTING/SETB <br />Request <br />Contact Name: john an <br />Site Address: 7037 MORGAN RD <br />Phone:4252581015 <br />e-Mail: evergreencontracting4@msn.com <br />6/1/2020 <br />6/l/2020 <br />BLDG <br />KMK <br />APPROVAL <br />eTRAKiT Inspection <br />5/28/2020 1:43 PM John an <br />06-UNDERSLAB <br />Request <br />Contact Name: john an <br />Site Address: 7037 MORGAN RD <br />Phone:4252581015 <br />e-Mail: evergreencontracting4@msn.com <br />7/16/2020 <br />7/16/2020 <br />BLDG <br />KMK <br />APPROVAL <br />eTRAKiT Inspection <br />7/16/2020 12:44 AM john an <br />07-EXTERIOR <br />Request <br />Contact Name: john an <br />Site Address: 7037 MORGAN RD <br />Phone:4252581015 <br />e-Mail: evergreencontracting4@msn.com <br />8/20/2020 <br />8/20/2020 <br />PLUMB <br />SDP <br />CORRECTION <br />eTRAKiT Inspection <br />8/18/2020 6:44 AM john an <br />02-GROUND <br />Request <br />Contact Name: john an <br />Site Address: 7037 MORGAN RD <br />Phone:4252581015 <br />e-Mail: evergreencontracting4@msn.com <br />(8/20/2020 3:03 PM SDP) <br />the toilet is not vented properly <br />8/20/2020 <br />8/20/2020 <br />PLUMB <br />SDP <br />CORRECTION <br />eTRAKiT Inspection <br />8/18/2020 6:44 AM john an <br />03-ROUGH IN <br />Request <br />Contact Name: john an <br />Site Address: 7037 MORGAN RD <br />Phone:4252581015 <br />e-Mail: evergreencontracting4@msn.com <br />(8/20/2020 3:27 PM SDP) <br />Methods are not to code. <br />1) A 2" trap is not big enough to handle two <br />washers. See Tbl's 702.2(1) and 703.1 in <br />the UPC. A 2" trap can hande 4 fixture <br />units and two washers equals 6 fixture <br />units. You would overwhelm the stand <br />pipe. <br />2) The method that the hose bib is installed <br />would not allow you to change it out with <br />out cutting into the drywall. If you tried to <br />un screw the hose bib from the outside you <br />stand the chance of twisting and breaking <br />the pipe inside of the wall as well as not <br />being able to screw a new one back in. <br />3) The toilet vent is undersized and you <br />cannot reduce the size of a vent from 2" to <br />1 1/2" . <br />INSPI2 C WYST <br />