9600 SHARON DR EXPLORER MIDDLE SCHOOL 2022-03-11
>
Address Records
>
SHARON DR
>
9600
>
EXPLORER MIDDLE SCHOOL
>
9600 SHARON DR EXPLORER MIDDLE SCHOOL 2022-03-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2022 10:53:08 AM
Creation date
11/9/2021 3:50:14 PM
Metadata
Fields
Template:
Address Document
Street Name
SHARON DR
Street Number
9600
Tenant Name
EXPLORER MIDDLE SCHOOL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXPLORER MS PORTABLES <br />UTILITY 12 MONTH PEAK DEMAND CALCULATION WORKSHEET <br />PANEL MDB <br />NEC 220.87 AND WAC 296-46B-900(3)0) <br />12 Month Peak Demand (Month & Year) : December 2019 <br />Phase to Phase Voltage (Volts) : 480 <br />Phases (1=Single Phase, 3=Three Phase) : 3 <br />Utility Peak Demand <br />Power Factor <br />Apparent Peak Demand <br />NEC 220.87(2) adjustment factor <br />Adjusted Peak Demand <br />Seasonal adjustment factor <br />Seasonal adjustment peak demand <br />Occupancy adjustment factor <br />Occupancy adjustment peak demand <br />Other adjustement factor(s) <br />Utility Peak Demand with Adjustments <br />New Calculated Demand Load Added <br />................... <br />............. . <br />1564 KW <br />/ 090 <br />(P.F.) <br />= 173.78 <br />KVA <br />X 1;25 <br />KVA <br />= 217.22 <br />KVA <br />X 100 <br />KVA <br />217.22 <br />KVA <br />X 1.00 <br />KVA <br />= 217.22 <br />KVA <br />X 100 <br />.................... <br />KVA <br />= 217.22 <br />KVA <br />PORTABLES + 110.67 KVA <br />Metered Demand Based <br />CALCULATED DEMAND LOAD: 327.89 KVA <br />CALCULATED DEMAND CURRENT: 394 AMPS <br />Note: See WAC 296-46B-900 (3)(j) for additional metering requirements <br />Explain how the factor was derived for 30-day demand metering: <br />Seasonal <br />Utilized utility furnished 12 month peak demand for load calculation, seasonal demand factor is not <br />necessary. <br />Occupancy <br />Since 12 months of demand data was utilized and normal occupancy occurred during the 12 month period, <br />no additional occupancy adjustment is necessary. <br />Other <br />No other adjustment factors were utilized for this demand calculation <br />