Simple Heating System Size: Washington State <br />This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals <br />J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br />The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. <br />The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. <br />Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some <br />values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at <br />(360) 956-2042 for assistance. <br />Project Information Contact Intortnation <br />ERKABAEV ANVAR RESIDENCE BEN TRAN <br />10103 1ST DR SE EVERETT, WA 98208 253 235 5532 <br />Heating System Type: O All Other Systems O Heat Pump <br />To see detailed instructions for each section, place your cursor on the word 'Instructions". <br />Design Temperature <br />Instructions - -- — <br />- - Design Temperature Difference (4T) <br />Snohomish <br />, AT =Indoor (70 degrees) -Outdoor Design Temp <br />Area of Building <br />Conditioned Floor Area <br />Instructions Conditioned Floor Area (sq ft),99 <br />Average Ceiling Height <br />Conditioned Volume <br />Instructions Average Ceiling Height (ft) <br />25,441 <br />Glazing and Doors <br />U-Factor <br />X Area = <br />UA <br />Instructions <br />47Y <br />143.10 <br />0.30 <br />Skylights <br />U-Factor <br />X Area = <br />UA <br />Instructions <br />0.50 <br />Insulation <br />Attic <br />U-Factor <br />X Area = <br />UA <br />_ - <br />Instructions <br />0.026 <br />1,385 <br />36.01 <br />R•38Advanced <br />.a— <br />SingleRafterorJoistVaultedCeilings <br />-- — <br />U-Factor <br />X Area <br />UA <br />Instructions <br />Select R-value <br />� . � <br />No selection <br />0 <br />--- <br />Above Grade Walls (see Figure 1) <br />U-Factor <br />X Area <br />UA <br />Instructions `— <br />'' R 21 Intermediate <br />0.056 <br />3,736 <br />209.22 <br />Floors <br />U-Factor <br />X Area <br />UA <br />•. _ <br />Instructions <br />0.025 <br />2,626 <br />65.65 <br />R•38 <br />Below Grade Walls (see Figure 1) <br />U-Factor <br />X Area <br />UA <br />Instructions Select R value <br />No selection <br />Slab Below Grade (see Figure 1) <br />F-Factor <br />X Length <br />UA <br />Instructions <br />Select condltioninq <br />No selection <br />0 <br />--- <br />Slab on Grade (see Figure 11 <br />F-Factor <br />X Length <br />UA <br />Instructions <br />Select R•Yakte <br />� <br />No selection <br />--- <br />Location of Ducts <br />Instructions -- .- __..__ _- <br />Duct Leakage Coefficient <br />C Conditioned Space <br />— <br />1.00 <br />Sum of UA <br />453.98 <br />Figure 1. <br />Above Grade <br />49 <br />Envelope Heat Load <br />22,245 <br />Btu / Hour <br />Sum of UA X dT <br />Air Leakage Heat Load <br />13,463 <br />Btu / Hour <br />VolumeX 0.6XATX.018 <br />Building Design Heat Load <br />35,708 <br />Btu / Hour <br />Air Leakage + Envelope Heat Loss <br />Building and Duct Heat Load <br />35,708 <br />Btu / Hour <br />Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 <br />Ducts in conditioned space: Sum of Building Heat Loss X 1 <br />Maximum Heat Equipment Output <br />49,991 <br />Btu / Hour <br />Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br />Building and Duct Heat Loss X 1.25 for Heat Pump <br />(07101113) <br />