s <br />2015 WSEC/IECC <br />REFER TO 2015 RESIDENTIAL CONSTRUCTION ENERGY COMPLIANCE FORM ATTACHED: <br />ENERGY CREDITS REQUIRED: USE OPTION 1d WITH MODIFICATION TO PRESCRIPTIVE COMPLIANCE <br />U-VALUE R-VALUE <br />VERTICAL FENESTRATION 0.28 <br />CEILING (ATTIC) C)• s- p2 R-49 <br />WOOD FRAME WALL ABOVE LEST R-21 int <br />FLOOR R-30 <br />ENERGY NOTES <br />1. BUILDING AIR LEAKAGE TEST REQUIRED PER WSEC R402.4.1.2, AIR LEAKAGE RATE OF NOT EXCEEDING 5 AIR CHANGES PER <br />HOUR. TESTING MUST BE CONDUCTED WITH A BLOWER DOOR AT A PRESSURE OF 0.2" w.g. (50 PASCALS). <br />2. DUCTS MUST BE LEAK TESTED IN ACCORDANCE WITH WSU RS-33 USING THE MAXIMUM DUCT LEAKAGE RATES SPECIFIED. <br />DUCT TIGHTNESS MUST BE VERIFIED BY EITHER THE POST CONSTRUCTION TEST OR ROUGH -IN TEST PER WSEC R403.2.2. <br />TOTAL LEAKAGE MUST BE LESS THAN OR EQUAL TO 4 CFM PER 100 SF OF CONDITIONED FLOOR AREA WHEN TESTED AT A <br />PRESSURE DIFFERENTIAL OF 0.1" w.g. (25 Pa) ACROSS THE ENTIRE SYSTEM. <br />3. A RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE IS REQUIRED TO BE COMPLETED BY BUILDER OR OWNER & <br />PERMANENTLY POSTED WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION PER WSEC R401.3 AND INCLUDE <br />THE FOLLOWING: PREDOMINATE R-VALUES, U-VALUES OF FENESTRATION, RESULTS FROM DUCT SYSTEM AND BUILDING <br />ENVELOPE AIR LEAKAGE TESTING, AND EFFICIENCIES OF HEATING/COOLING/WATER HEATING EQUIPMENT. <br />4. EXTERIOR WALL HEADER INSULATION INSTALLATION PER IECC/WSEC R202; ADVANCED FRAMED WALLS AND <br />INTERMEDIATE FRAMED WALLS PER WSEC R402.2. <br />5. R-4 INSULATION ON HOT WATER PIPING REQUIRED PER WSEC R403.4.2. <br />6. A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN INTERIOR OR EXTERIOR LIGHTING FIXTURES MUST BE <br />HIGH -EFFICIENT LAMPS PER WSEC R404.1. <br />[ wWi dal C dit.0 f- R.Wi .t .l New Con. tl- <br />WIDTH X HEIGHT <br />1 3.5'x4' <br />APPLICABLE CODES AND REFERENCES <br />2015 INTERNATIONAL RESIDENTIAL CODE (IRC) & WAC 51-51 <br />2015 INTERNATIONAL MECHANICAL CODE <br />2015 INTERNATIONAL FIRE CODE (IFC) & WAC 51-54 <br />2015 WASHINGTON STATE ENERGY CODE RESIDENTIAL (WSEC) <br />2015 WASHINGTON STATE ENERGY CODE APPENDIX (WSEC) <br />2015 UNIFORM PLUMBING CODE <br />2017 NATIONAL ELECTRICAL CODE (NFPA 70) & WAC 296-46B-010 <br />2015 WASHINGTON STATE-WIDE AMENDMENTS <br />CITY OF EVERETT DESIGN & CONSTRUCTION STANDARDS & SPECS. <br />WINDOW SCHEDULE <br />GLASS AREA S.F. I NOTE: ALL WINDOWS WILL BE 'NFRC CERTIFIED' <br />14 1 $*pgw-Ty SLIDER <br />2 5'x4' 20 SLIDER BEDROOM EGRESS WINDOW, REFER TO <br />CONSTRUCTION NOTE <br />SUB -TOTAL S.F. WINDOW GLAZINGI 34 <br />DOOR SCHEDULE <br />Q WIDTH HEIGHT I MATERIAL REMARKS <br />001 I 36" I 80' I EXTERIOR INSULATEOLID D DOOR I WEATHER -PROTECTION OR WITH <br />002 30" 80" HOLLOW WOOD LOCK <br />003 26" 80" HOLLOW WOOD LOCK <br />TING GARAGE <br />A DE <br />INSULATIO <br />NEW HEATED SPA <br />PER SCHEDULE <br />EXISTING <br />GARAGE <br />TO REMAIN <br />I <br />NEW DOOR <br />& WINDOW <br />FRONT <br />OF BUILDING <br />001 <br />i 12" RAISED FLOOR <br />REFER TO A- 4/12 <br />i FOR DETAIL <br />PROJECT AREA BUILDING SECTION <br />SCALE: 1/4" = V-0" <br />w <br />w0 <br />9oi� <br />N O <br />0 <br />CONSTRUCTION NOTES <br />1. EXTERIOR WALL CONSTRUCTION IS 2x6 @ 16"o.c. TYPICAL, INTERIOR WALLS ARE 2x4 @ 16"o.c. TYPICAL UNLESS OTHERWISE NOTED. <br />2. BATHROOM AND LAUNDRY FANS: 65 CFM, KITCHEN EXHAUST FAN: 100 CFM. LI <br />3. MINIMUM AIR INTAKE OPENINGS = 4 sq. in. PER ROOM. <br />4. IN EVERY SLEEPING ROOM, PROVIDE AN EMERGENCY EXIT WINDOW WITH A WIDTH OF 20" MIN. & HT. 24" & NOT LESS THAN 5.7 S.F. OPENABLE AREA (MIN. <br />3'x4'-6" IF DOUBLE HUNG OR WxT-6" WINDOW IF SLIDER) AND NOT MORE THAN 44" FROM FLOOR TO SILL. <br />5. SMOKE DETECTORS (S.D.) ARE REQUIRED FOR ALL BEDROOMS AND HALLWAY, HARDWIRED & INTERCONNECTED w/BATTERY BACK-UP. <br />6. PROVIDE WATER-RESISTANT GWB BEHIND ALL PLUMBING FIXTURES, PROVIDE WATER-RESISTANT WAINSCOT = 60" C.T. AROUND TUB. <br />7. MOISTURE CONTROL: EXTERIOR DOORS AND WINDOWS TO BE CAULKED AND WEATHER STRIPPED. RECESSED LIGHTING FIXTURES TO LIMIT AIR LEAKAGE PER <br />WSEC 502.4.4 IN UNCONDITIONED AREAS. ALL PLUMBING, ELECTRICAL,& HVAC PENETRATIONS IN FLOORS, WALLS, & CEILINGS ARE TO BE CAULKED AND <br />SEALED. ELECTRICAL OUTLETS & LIGHT SWITCH BOXES ON EXTERIOR WALLS MUST BE SEALED AT THE BACK OF THE BOX OR EQUIPPED WITH A FACE PLATE <br />GASKET. SOLE PLATE MUST BE CAULKED OR GLUED TO SUB -FLOOR. CAULK & SEAL RIM JOISTS BETWEEN STORIES. <br />4e51_1wu,1e51gt7 <br />14632 - 14th Ave. SE <br />Mill Creek, WA 98012 <br />(425) 512-1780 <br />dwudesign@gmail.com <br />SHEET TITLE: <br />CONSTRUCTION NOTES, <br />2015 W.S.E.C. <br />SCHEDULES <br />& BUILDING SECTION <br />PROJECT: <br />LUBWAMA <br />RESIDENCE <br />ADU <br />LOCATION: <br />1218 59th PLACE SW <br />EVERETT, WA 98203 <br />FILE: 2020-018 <br />DATE: 04/17/2020 <br />PREPARED BY: D. Wu <br />REVISIONS: <br />SHEET NUMBER: <br />A- 3 <br />8. ALL CARBON MONOXIDE ALARM SHALL COMPLY WITH UL2034, TYP., LOCATE OUTSIDE OF BEDROOMS HALLWAY. <br />