Laserfiche WebLink
Maintenance Component: ,. <br />Defect <br />i '.. Conditions When Ma7ntenance Is Needed <br />Results Expected When Maintenance Is per--.. <br />donned' . <br />(A percolation test pit ortest of facility indicates facility, is only working at 909A of its designed capabilities. Test every 2 to 5 years. If <br />p : <br />; <br />two inches or more sediment is present, remove). <br />' <br />RfterBags(dapplicable) <br />Fdiedwith Sediment and <br />Sediment and debris fill bag more than 1/2full. <br />Filter bag isrepl"tirsystemisredesigned. <br />Debris <br />; <br />Rock Filters <br />Sediment and Debris <br />By visual inspection, little orno waterflows; through flitertludng heavy rain storms.. <br />Gravel in ruckfiltertri replaced: <br />Side Slopes of Pond <br />Erosion <br />SeeTable V-A.1: Maintenance Standards- Detention Pcinds <br />See Table V-A.1: MAtenance Standards- Deten- <br />tion Ponds <br />Tree Growth <br />SeeTaMe V A.1: Maintenance Standards -Detention Ponds <br />See Table V A 1. Maintenance Standards - Deten- <br />Emergency Overflow Spil14. <br />Lion Ponds <br />and Berths over4 feet in height <br />Piping <br />See TableV-AA: Maintenance Standards -Detention Ponds <br />See Table V-A 1: Mafnenance Standards - Deter <br />Lion Ponds <br />Rock Missing <br />See TableV-A-1.MaintenanceStandards-DetentionPonds <br />See Table V-A1:M✓3fntenanceStandards -Detem <br />Emergency Overflow SprgwAr <br />lion Ponds <br />Erosion <br />SeeTable V A 1: Maintenance Standards -Detention Ponds <br />See Table V-A.1: Maintenance Standards - Deten- <br />tion Ponds <br />f <br />Facility orsump filled ; <br />Pre -settling Ponds and Vaull3 <br />with Sediment and/or <br />6' or designed sediment trap depth of sediment. <br />Sediment is remov4 <br />debris <br />s• Table V A.3: Maintenance Standards -Closed Detention Systems (TankslVaults) <br />Maintenance <br />'.' <br />Defect. <br />• • - <br />Conditions When Maintenance is'Needed ' <br />Resultt s. Expected When Maintenance is Per - <br />Component <br />formed <br />Plugged Air Vents <br />One Ralf of the cross section of a vent is blocked at any pant orthe vent Is damaged. <br />Vents open and functioning. <br />Accumulated sediment depth exceeds 10%.of the diameter of the storage -for 112length of storage vault orany point <br />, <br />Debris a6d Sediment <br />depth exceeds 15% of diameter. <br />All sediment soil debris removed from storage <br />(Example:72-inch storagetank would require cleaning when sediment reaches depth of 7 inches formorethan 112length 'of <br />area - <br />StorageArea <br />tank.) <br />AnYopeningsorvoidsallirwingmaterialtobetransportedIntofaality. <br />JoiMsBetweenTank/Pi Section - <br />pe <br />(MR require engineering analysis to determine sbuctuual stability).. <br />All Joint between tank/pipe sections are sealed. <br />Any pat of tank/pipe is bent out of shape more than 10% of fts design shape. (Review required by engineerto determine <br />Tank Pi Bent Out of Shape <br />� <br />structural stabltty). <br />Tatrk/plpe repaired or replaced to design. <br />Cracks widerthan 1124nch and any evidence of soil particles entering the structure through the cracks, or main- <br />Vault replaced or repaired to design spe- <br />Vault Structure Includes Cracks in Wall. Bottom, <br />tenanceBnspection personnel determines that the vault is not structurally sound. <br />cifications and is structurally sound. <br />Damage to Frame andlorTop Slab <br />Cracks wider than 112 inch at the Joint of any irdef/outfet pipe or any evidence of so l particles entering the vault through the <br />No cracks more than I WrichwideattheJoIntof <br />walls <br />the lydetfoudet pipe. <br />