My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2325 75TH ST SE 2021-12-27
>
Address Records
>
75TH ST SE
>
2325
>
2325 75TH ST SE 2021-12-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 4:05:49 PM
Creation date
11/10/2021 10:52:27 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
2325
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />Simple Heating System Size: Washington State <br />This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA <br />Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling <br />loads. <br />The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br />0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. <br />Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, <br />some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension <br />Program at (360) 956-2042 for assistance. <br />Project Information Contact Information <br />Joel Hacck JAmerican Home Planners <br />(425)258-6400 <br />Heatina System Tyne: O All Other Systems O Heat Pump <br />To see detailed instructions for each section, place your cursor on the word 'Instructions". <br />Desian Temperature <br />Everett Paine AFB W Design Temperature Difference (AT) 49 <br />Area of Buildina <br />Conditioned Floor Area <br />Conditioned Floor Area (sq ft) <br />Average Ceiling Height <br />Average Ceiling Height (ft) <br />Glazing and Doors <br />Sk Iv iahts <br />Insulation <br />Attic <br />R 49 <br />Single Rafter or Joist Vaulted Ceilings <br />No Vaulted Cei ings .n tl+i5 pFojec[. <br />Above Grade Walls teas Figure 1) <br />R-21 Intermed ate <br />Floors <br />R-30 <br />Below Grade Walls (see Figure 1) <br />No Belo . Grade walls m. this project. <br />Slab Below Grade (see Figure i) <br />No Slab Below Grade in this project. <br />Slab on Grade (sae Figure r) <br />No Slab on Grade in the project. <br />Location of Ducts <br />Unconditioned Space <br />F, inure 1. <br />Above Grade <br />BefRw"6tade . <br />AT = Indoor (70 degrees) - Outdoor Design T rfe_:y, <br />t�bD rs U FE <br />2,230 <br />Conditioned Vol a MAR 2 6 2021 <br />8.5 18,955 0 <br />U-Factor X Area =CIRY OF EVERETT <br />0.30 360 108ftrmit Services <br />U-Factor X Area = UA <br />0.50 --- <br />U-Factor X Area — <br />UA <br />0.026 F 17384 <br />35.98 <br />U-Factor X Area <br />UA <br />U-Factor X Area <br />UA <br />0.056 2,572 <br />144.03 <br />U-Factor X Area <br />UA <br />0.029 F 978 <br />28.36 <br />U-Factor XrArea <br />UA <br />F-Factor X Lr y� <br />UA <br />F-Factor X Lefth i <br />UA <br />_ Duct Leakage Coefficient <br />1.10 <br />Sum of UA <br />316.38 <br />Envelope Heat Load <br />15,503 Btu / Hour <br />Sum of UA X AT <br />Air Leakage Heat Load <br />10,031 Btu / Hour <br />VolumeX 0.6XATX.018 <br />Building Design Heat Load <br />25,534 Btu / Hour <br />Air Leakage + Envelope Heat Loss <br />Building and Duct Heat Load <br />28,087 Btu / Hour <br />Duds in unconditioned space: Sum of Building Heat Loss X 1.10 <br />Duds in conditioned space: Sum of Building Heat Loss <br />X 1 <br />Maximum Heat Equipment Output <br />39,322 Btu I Hour <br />Building and Dud Heat Loss X 1.40 for Forced Air Furnace <br />Building and Dud Heat Loss X 1.25 for Heat Pump <br />(07101113) <br />
The URL can be used to link to this page
Your browser does not support the video tag.