Laserfiche WebLink
STRUCTURAL NOTES <br /> (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS)CODE LUMBER L.T ■ ■Mobile■ <br /> ABBREVIATIONS <br /> ALL MATERIALS,WORKMANSHIP,DESIGN,AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED.ALL LUMBER SHALL BE IN ACCORDANCE WITH W WPA (A) ABOVE GLB GLUE-LAMINATED BEAM <br /> SPECIFICATIONS,AND THE INTERNATIONAL BUILDING CODE(IBC),2015 EDITION.SPECIFICATIONS AND STANDARDS GRADING RULES,KILN-DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: <br /> WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. AB ANCHOR BOLT HORIZ HORIZONTAL <br /> DESIGN LOADS SIZE CLASSIFICATION SPECIES GRADE Fb(PSI) Fc(PSI) ALT ALTERNATE KP KING POST —PROJECT INFORMATION: <br /> SLEEPERS DOUG-FIR STUD 700 - ARCH ARCHITECT K51 KIPS PER SQUARE INCH <br /> DEAD (B) BELOW L ANGLE MOSQUITO FLEET <br /> ROOF 85PSF REFER TO PLAN NOTES,SCHEDULES,AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS <br /> BD BAR DIAMETER MECH MECHANICAL HOSPITAL <br /> LIVE LOADS: - UNLESS NOTED OTHERWISE IN THE PLANS,ALL WOOD AND WOOD-BASED MEMBERS EXPOSED TO WEATHER OR BLKG BLOCKING MF MOMENT FRAME <br /> ROOF(SNOW LOAD) 25 PSF IN CONTACT WITH CONCRETE,MASONRY,OR WITHIN 8"OF SOIL SHALL BE PRESERVATIVE-TREATED BY SE01523A <br /> VACUUM-PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD Ul. BM BEAM MU METAL <br /> DESIGN LOADS NAILS,BOLTS,AND METAL CONNECTORS FOR WOOD BOT BOTTOM NS NEAR SIDE <br /> 1321 COLBY AVENUE <br /> SCREENWALL DEAD LOAD: 2,300 LBS(INCLUDES APPURTENANCES AND FRAMING) BRNG BEARING OC ON CENTER <br /> ANTENNA MOUNTS: 500 LBS(EA)MAX ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS(NDS)FOR EVERETT,WA 98201 <br /> EQUIPMENTCABINETS: 3,070 LBS(TOTAL) WOOD CONSTRUCTION,LATEST EDITION.NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING BTWN BETWEEN OPP OPPOSITE <br /> SCHEDULE.ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL OP COMPLETE JOINT PENETRATION PL PLATE —ISSUED FOR: <br /> ROOFTOP SCREENWALL: MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: <br /> -— CLR CLEAR PLCS PLACES <br /> WIND LOAD:115 MPH EXPOSURES NAIL SHANK 0 MIN LENGTH BUILDING PERMIT <br /> CMU CONCRETE MASONRY UNIT PSI POUNDS PER SQUARE INCH <br /> Bd COMMON 0.1310 21/2'SHANK <br /> F= qz x(GCf)x Af=23.5 PSF(ASD) COL COLUMN PSF POUNDS PER SQUARE FOOT —REVISION HISTORY: <br /> qz= 29.8 PSF(Kz=1.03,Ka.1.0,Kd=0.85) 10d COMMON 0.1480 3'SHANK CHUB. <br /> CONC CONCRETE P/T POST TENSIONED NO. DATE: DESCRIPTION: BY, <br /> GU= 1.32(G=0.85,Cf=1.55) 12d COMMON 0.1480 3 1/4"SHANK <br /> RISK CATEGORY IV CONN CONNECTION PT PRESSURE TREATED I <br /> 16d COMMON 0.1620 3112'SHANK CONT CONTINUOUS REINF REINFORCING <br /> SEISMIC LOAD:SEISMIC DESIGN CATEGORY D,SOIL TYPE Sd <br /> 10d BOX NAILS MAYBE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING.FRAMING COORD COORDINATE REQ'D REQUIRED <br /> Fp= pp [1+2z/h)Wp=0.301 Wp(ASD) MEMBERS MAY BE NAILED WITH 16d SINKERS(0.148"0 x 31/4"),BUT ONLY 16d COMMON NAILS SHALL BE USED DBL DOUBLE SCHED SCHEDULE _ <br /> ap= 1.0(SCREENWALL) WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET.ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS DET DETAIL SIM SIMILAR <br /> Rp= 2.5(SCREENWALL) ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. <br /> Sds= 0.854(Ss=1.281&Fa=1.0 BASED ON LAT/LONG) DIA DIAMETER 50G SLAB ON GRADE <br /> Ip= 1.5 ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307.PROVIDE WASHERS UNDER THE HEADS AND DIM DIMENSION STD STANDARD <br /> z/h= 1.08 NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD.LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR <br /> THE SHANK AND THREADED PORTIONS PER NDS 11.1.3. DIR DIRECTION STIFF STIFFENER <br /> STATEMENT OF SPECIAL INSPECTIONS <br /> GALVANIZATION EA EACH STL STEEL <br /> SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE.THE CONTRACTOR SHALL SUBMIT A ELEV ELEVATION SYMM SYMMETRICAL <br /> WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF UNLESS NOTED OTHERWISE,STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED <br /> WORK IN ACCORDANCE WITH CHAPTER 1704.4 OF THE IBC. ACCORDING TO THE FOLLOWING TABLE: ES EACH SIDE SW SHEARWALL _ <br /> SPECIAL INSPECTION FOR THE ABOVE SYSTEMS SHALL BE AS INDICATED IN THE SPECIAL INSPECTION TABLE BELOW. GALVANIZATION UNTREATED ACQ-C CBA-A OTHER ACZ OTHER PT EX EXISTING TOC TOP OF CONCRETE <br /> WOOD CCA-C SBX ACQ-D CA-B BORATE A WOOD <br /> EXP EXPANSION TOS TOP OF STEEL - <br /> STRUCTURALOBSERVATIONOFTHESTRUCTURALSYSTEMBYTHEENGINEERISNOTREQUIRED. G90 X X X FLR FLOOR TOW TOP OF WALL <br /> SPECIAL INSPECTION G185 X X X X X X FON FOUNDATION TYP TYPICAL <br /> HDG X X X X X X FTG FOOTING UNO UNLESS NOTED OTHERWISE <br /> OPERATION CONT PERIODIC REMARKS- STT300 % X X X X X X X <br /> STRUCTURAL STEEL&FRP FS FAR SIDE VERT VERTICAL <br /> ' G90=0.90 OZ.OF ZINC PER SQUARE FOOT OF AREA GC GENERAL CONTRACTOR WF WIDE FLANGE <br /> FABRICATION&ERECTION X G185=1.85 OZ.OF ZINC PER SQUARE FOOT OF AREA_ <br /> SHOP&FIELD WELDING HDG=HOT DIP GALVANIZED 1 12/22/2020 PERMIT SUBIRTN. LLIS <br /> SST300=TYPE 3161 STAINLESS STEEL <br /> SINGLE PASS FILLET WELDS 5 5/16' X —PLANS PREPARED BY: <br /> _ FIBER REINFORCED POLYMER(FRP)SHAPES AND FASTENERS <br /> NOTE: <br /> ALL ITEMS MARKED WITH AN"X"SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17.SPECIAL ALL FRP STRUCTURAL SHAPES SHALL BE 1625 SERIES PULTEX STANDARD PROFILES BY CREATIVE PULTRUSIONS,INCINSPECTI ��..���M <br /> ON SHALL UE AL PERFORMED BY ANA D <br /> QUALIFIED ILDIN OFFICIAL <br /> AGENCY DESIGNATED BYTHE OWNER.THE AE OR APPROVED EQUAL. �Rd0N <br /> ARCHITECT,STRUCTURAL ENGINEER,ANDBUILDINGOFFICIALSHALL BE FURNISHED WTH COPIES OF ALL <br /> RESULTS.ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT ALL FRP FLAT PANELS SHALL BE 1500/1525 OR 1625 SERIES PULTEX STANDARD PROFILES BY CREATIVE <br /> TO THE ATTENTION OF THE DESIGN TEAM. PULTRUSIONS,INC OR APPROVED EQUAL. <br /> END all MG■,RITE LR <br /> DM (42187 1LINO <br /> BOLTS AND NUTS SHALL BE SUPERSTUD FIBER REINFORCED POLYMER FASTENER SYSTEM BY CREATIVE Roc (a■)7 41331 <br /> SHOP DRAWINGS PULTRUSIONS,INC OR APPROVED EQUAL. (�7h� <br /> SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL CGX:20070.714 <br /> ENGINEER FOR REVIEW PRIOR TO FABRICATION: ALL FRP PRODUCTS EXPOSED TO WEATHER SHALL CONTAIN AN ULTRAVIOLET INHIBITOR. <br /> DRAWN BY: CHK.BY: <br /> 1.FRP SCREENWALLS ALL FIELD CUT,DRILLED EDGES AND HOLES SHALL BE SEALED WITH CATALYZED RESIN AS RECOMMENDED BY <br /> MANUFACTURER. <br /> SHOP DRAWINGS SHALL BE REVIEWED,REVISED AS REQUIRED FOR FIELD CONDITIONS,AND DATE STAMPED BY FIBER REINFORCED POLYMER PRODUCTS SHALL BE DESIGNED AND PROVIDED BY HI-TECH COMPOSITE JEG LMS <br /> THE CONTRACTOR PRIOR TO REVIEW BY THE ENGINEER.CONTRACTOR SHALL PROVIDE(3)SETS OF SHOP STRUCTURES OR ENGINEER-APPROVED EQUIVALENT MANUFACTURER.SHOP DRAWINGS ARE REQUIRED PER THE <br /> DRAWINGS FOR ENGINEER'S REVIEW.ALLOW TWO WEEKS FOR SHOP DRAWING APPROVAL BY ENGINEER. STRUCTURAL NOTES AND SHALL BE DESIGNED AND STAMPED BY THE MANUFACTURER'S PROFESSIONAL <br /> ENGINEER LICENSED IN THE SAME STATE AS THE PROJECT.REFER TO THE DESIGN LOADS SECTION OF THE ,—LICENSURE: <br /> ENGINEER'S SHOP DRAWING REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AND STRUCTURAL NOTES FOR MAXIMUM WEIGHT OF SCREENWALL AS WELL AS LATERAL FORCE REQUIREMENTS. <br /> CONTRACT DOCUMENTS.MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR <br /> FROM COMPUANCE WITH THE PROJECT PLANS AND SPECIFICATIONS.THE CONTRACTOR REMAINS RESPONSIBLE EXISTING BUILDING <br /> FOR DETAILS AND ACCURACY,FOR CONFORMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS,FOR d0, <br /> SELECTING FABRICATION PROCESSES,FOR TECHNIQUES OF ASSEMBLY,AND FOR PERFORMING THE WORK IN A CONTRACTOR SHALL VERIFY ALL DIMENSIONS,MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING fgb 01 W.Ulfr <br /> SAFE MANNER. DEPICTED IN THE DRAWINGS,AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE S.A1' <br /> ENGINEER'S SHOP DRAWING REVIEW OF STRUCTURAL COMPONENTS DESIGNED BY OTHERS IS FOR LOADS REDESIGN. �. m� L A <br /> IMPOSED ON THE BASIC STRUCTURE.THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE CONFORMANCE <br /> AND ALL CONNECTIONS TO THE BASIC STRUCTURE.SHOP DRAWINGS SHALL INDICATE MAGNITUDE AND CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS (' ,�'' <br /> DIRECTION OF THE LOADS IMPOSED ON THE BASIC STRUCTURE AND SHALL BE STAMPED&SIGNED BYA PENETRATED OR REMOVED.PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. >� <br /> PROFESSIONAL ENGINEER REGISTERED IN THE SAME STATE AS THE PROJECT. GENERAL ZONAL <br /> 12/22/2020 <br /> FABRICATION SHALL BEGIN ONLY AFTER SHOP DRAWINGS BEARING THE STAMP AND SIGNATURE OF THE PROJECT STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL,CIVIL,ELECTRICAL,AND <br /> ARCHITECT,ENGINEER OF RECORD,AND CONTRACTOR HAVE BEEN RECEIVED. MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND <br /> DEFERRED APPROVAL ITEMS CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING.ANY DISCREPANCIES SHALL BE BROUGHT TO THE —JURISDICTIONAL APPROVAL: <br /> ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. <br /> SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT OR CONTRACTOR TO SEE ARCHITECTURAL,CIVIL,ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION <br /> ENGINEER OF RECORD WHO SHALL REVIEW THEM AND INDICATE THAT THE DEFERRED SUBMITTAL DOCUMENTS OF PIPE,VENT,DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. <br /> HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN <br /> OF THE BUILDING.THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL <br /> SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. <br /> 1.FRP SCREENWALLS CONTRACTOR-INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL <br /> [ <br /> STRUCTURAL STEEL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION.CHANGES SHOWN ON SHOP DRAWINGS <br /> ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWING TITLE: <br /> STRUCTURAL STEEL DESIGN,FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.WHERE CONDITIONS ARE NOT <br /> "SPECIFICATION FOR THE DESIGN,FABRICATION,AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS",LATEST SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN,SIMILAR DETAILS OF <br /> EDITION. CONSTRUCTION SHALL BE USED,SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL • <br /> STRUCTURAL <br /> SHAPES SHALL CONFORM TO ASTM A992,Fy=50 KS!. ENGINEER. C <br /> PLATES,ANGLES,AND RODS SHALL CONFORM TO ASTM A36,Fy=36 KSI. - OTG V <br /> STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE B,Fy=46 KSI. <br /> STEEL PIPE SHALL CONFORM TO ASTM A53 GRADE B,Fy=35 KS!. DRAWING NUMBER:• <br /> -BOLTS CONNECTING STEEL MEMBERS SHALL CONFORM TO ASTM A325-N.BOLTS SHALL BE 3/4"0 MINIMUM,UNO <br /> ANCHOR BOLTS SHALL CONFORM TO ASTM A307. /`'� <br /> CONTRACTOR SHALL PROVIDE CONNECTION ADJUSTMENT TOLERANCES TO SATISFY THE REQUIREMENTS OF AISC J O <br /> MANUAL OF STEEL CONSTRUCTION. ■ <br /> UNLESS SPECIFIED AS STAINLESS STEEL,ALL STEEL MEMBERS,SHAPES,BOLTS,AND ACCESSORIES EXPOSED TO <br /> WEATHER SHALL BE HOT DIP GALVANIZED. <br /> 22125 <br />