Laserfiche WebLink
2015 Washington State EneeCode Compliance Forms for Commercial,R2 and R3 over Ones and all R1-Page 12 of 22 <br /> Service Water Heating Permit Plans Checklist SWH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: ESD-ATHLETICSBUILDING Date 5/28/2020 <br /> The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (ves.no.nal Documents Notes <br /> Equipment-Sizing,Performance and Type <br /> Yes C404.2 SWH equipment type and Provide equipment schedule on plans indicating type and capacity;indicate efficiency complies M-0.2 <br /> efficiency with required federal standard <br /> For individual SWH equipment serving an entire building with a 1,000,000 Btu/h capacity, <br /> indicate thermal efficiency a 90%;or exception taken <br /> High input-rated SWH For buildings with aggregate capacity of all SHW equipment a 1,000,000 Btu/h(exclude< <br /> NA C404.2.1 systems 100,000 Btu/h equipment from threshold calculation),indicate average capacity weighted <br /> thermal efficiency a 90%:or exception taken <br /> If applying Exception 1 for site-solar or site-recovered energy,provide calculations and source <br /> of annual service water heating energy use estimate <br /> N/A C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply and discharge <br /> N/A C404.5 Insulation under electric For electric water heaters located in unconditioned spaces or on concrete floors,indicate R-10 <br /> water heater insulation under equipment <br /> Piping Systems <br /> Indicate thickness of piping insulation on plans per Table C403.2.9;verify insulation is provided M-3 <br /> Yes C404.6 Insulation of piping -from the water heater to the final fixture in a line,from the inlet/outlet piping at water heater <br /> to heat trap fuo to 8 feet).and on piping that is heat traced:note exceptions taken <br /> Indicate method of compliance on plans for all piping runs connecting service hot water source <br /> NA C404.3 Efficient SWH supply piping to hot water fixture(maximum pipe length or maximum pipe volume method per Table <br /> C404 7 11•nrnvide calculations for all nininn runs documenting the total length and/nr volume <br /> Service Water Heating System Controls <br /> For circulation systems with dedicated return piping,indicate controls are configured to <br /> automatically start pump based on demand for hot water and shut-off pump when there is no <br /> Yes C404.7.1 Heated-water circulating For circulation systemsdwith cold watery supplytpiping met <br /> as the return,indicate controls are M-3.3 <br /> C404.8 systems configured to automatically start pump based on demand for hot water and shut-off pump <br /> when there is no demand,or when temperature of water entering the cold water supply pipe is <br /> F1Q4°F <br /> or heat trace systems provided to maintain temperature of service hot water in piping,indicate <br /> NA C404.7.2 Heat trace system controls controls are configured to de-energize system when there is no demand for hot water and <br /> when the desired water temperature is met <br /> NA C404.7.3 Controls for hot water For systems with separate water heater and storage tank,indicate controls are configured to <br /> storage limit operation time of pump after end of heating cycle to s 5 minutes <br /> For SWH,pool/spa and pressure boosting pump motors a 7.5 hp,indicate method of variable <br /> C403.2.13 Variable flow control- flow control(VSD or equivalent method that requires a 30%design wattage at 50%design fluid <br /> NA C403.4.2.7 pumps flow):note exception taken <br /> Identify basis of pump speed control(differential or static pressure setpoint,pressure,zone <br /> load demand etc) <br /> Pools and Permanent Spas-Equipment and Controls(Sections are under C404.11) <br /> Pool heating equipment Provide equipment schedule on plans indicating type and capacity for all pool heating <br /> NA C404.10.1 efficiency equipment;indicate efficiency complies with required federal standard;for heat pump water <br /> heaters indicate COP a 4 <br /> NA C403.2.13 Variable flow control Refer to Service Water Heating System Controls <br /> pumps <br /> C404.10.1 Indicate automatic on/off control based on scheduling and readily accessible on/off switch on <br /> NA C404.10.2 Pool heater on/off controls heater that operates independent of thermostat setting;note exceptions taken <br /> For all pools and in-ground permanent spas,indicate a vapor retardant cover on plans <br /> NA C404.10.3 Pool covers For all pools and in-ground spas heated to>90°F,indicate cover shall include insulation a R- <br /> 12 <br /> NA C404.10.3 Pool assembly insulation For all pools and in-ground spas heated to>90°F,Indicate on plans that sides and bottom are <br /> provided with insulation a R-12 <br /> NA C404.12 Energy consumption of Indicate portable spa complies with Association of Pool and Spa Professionals APSP-14 <br /> portable spas <br /> VD \ <br />