My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6107 BERKSHIRE DR A T AND T ANTENNA 2021-12-10
>
Address Records
>
BERKSHIRE DR
>
6107
>
A T AND T ANTENNA
>
6107 BERKSHIRE DR A T AND T ANTENNA 2021-12-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2021 9:41:13 AM
Creation date
12/9/2021 9:41:50 AM
Metadata
Fields
Template:
Address Document
Street Name
BERKSHIRE DR
Street Number
6107
Tenant Name
A T AND T ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EQUIPMENT CHASSIS V (2) 3/8"0 SS HEX NUT HYLUG CONNECTOR INSTALLATION <br />GROUNDING BUSS BAR / INSTRUCTIONS: <br />CABLE RACEWAY (#2) TWO HOLE 1. SELECT PROPER HYLUG FOR THE WIRE SIZE USED. <br />COMPRESSION LUG 2. STRIP CABLE OF INSULATION TO A LENGTH EQUAL <br />GROUND WIRE STUD (TYP OF 2 @ TO THE BARREL OF THE CONNECTOR. <br />NO -LUX ANTI -OXIDIZING FRONT AND BACK OF CABINET) 3. INSERT CABLE FULLY INTO CONNECTOR. <br />COMPOUND 4. APPLY THE PROPER NUMBER OF CRIMPS AS <br />SHOWN BY NUMBER OF COLORED BANDS. <br />CLEAR HEAT SHRINK ON 5. CRIMP FROM TONGUE END OF CONNECTOR <br />COMPRESSION LUGS TOWARD CABLES FOR TERMINALS AND CENTER <br />SPLICE TOWARD CABLE FOR BUTT SPLICES <br />3/8"0 STAR WASHER #2 STRANDED GREEN REQUIRING MORE THAN ONE CRIMP PER END. <br />INSULATED COPPER GROUND <br />LEAD TO BUSS BAR OR #2 HYLUG TYPE YGA CONNECTOR IS PRE -FILLED WITH <br />SOLID BARE TINNED COPPER PENETROX COMPOUND AND STRIP SEALED. <br />PLAN TO (E) GROUNDING SYSTEM <br />BURNDY HYDRAULIC DIE SET #U1CRT-1/U11T. <br />NOTE: <br />FOR GROUNDING CONNECTIONS TO PAINTED CABINETS <br />CHASSIS, GRIND OFF ALL ENAMEL COATINGS TO BARE METAL <br />AT LUG CONTACT AREA PRIOR TO MAKING BOLTED LUG <br />CONNECTION. APPLY NO -LUX TO ALL EXPOSED BARE METAL. <br />NOT USED 12 NOT USED GROUND LUG CONNECTION 9 <br />22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS <br />GROUND BAR ATTACHMENT: COAXIAL GROUND KITS W/ <br />LONG BARREL COMPRESSION <br />CONCRETE SUBSTRATE: (4) 3/8"0 HILTI TZ EXPANSION ANCHORS DOUBLE LUGS, ATTACH TO <br />WITH 2" MINIMUM EMBEDMENT. GROUND BAR & INSTALL BY <br />ANTENNA CONTRACTOR <br />WOOD FRAMED SUBSTRATE: (4) 3/8"0 LAG SCREWS WITH 2" MINIMUM (CADWELD TYPE-GL) <br />EMBEDMENT (ADD BLOCKING IF <br />NECESSARY. <br />CLEAR HEAT SHRINK 4"x 24"x 114" THK COPPER <br />SOLID CMU WALL: (4) 3/8"0 HILTI TZ EXPANSION ANCHORS ON COMPRESSION LUGS GROUND BAR. INSTALLED <br />WITH 2' MINIMUM EMBEDMENT. BY GENERAL CONTRACTOR <br />HOLLOW CMU WALL: (4) 3/8"0 HILTI HIT HY-20 WITH HIT -A O O <br />STANDARD RODS. (3 3/8" EMBEDMENT) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 <br />0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I <br />NOTE: O o000000000000000o O <br />COAT ALL MECHANICAL CONNECTIONS <br />W/'NO-LUX" OR APPROVED EQUAL 200 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a <br />o O <br />24' <br />FIELD VERIFY <br />#2 SOLID BARE TINNED <br />COPPER WIRE CADWELD (TYPE-GL) <br />TYPICAL GROUND BUSS BAR CONNECTIONS <br />22x34 SCALE NTS 11x17 SCALE: NTS <br />7 <br />TYPE GL LUG <br />TYPE GR <br />Gy! TYPE PT <br />TYPE GT TYPE SS <br />TYPE VS <br />NOTE: <br />CADWELD "TYPES' SHOWN ABOVE ARE EXAMPLES -CONSULT <br />WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS <br />TO BE USED FOR THIS PROJECT. <br />CADWELD DETAIL 4 NOT USED 3 NOT USED <br />22x34 SCALE: NTS 11x17 SCALE: NTS I 22x34 SCALE: NTS _ 11x17 SCALE: NTS 22x34 SCALE., NTS 111x17 SCALE: NTS <br />► at&t <br />Your world. <br />`—PLANS PREPARED BY: <br />_� �HCOr�NEr15 oONo <br />16928 WOODINVILLE-REDMOND RD NE, SUITE 210 <br />WOODINVILLE, WA W072 <br />PHONE! 426.487.1732 <br />W W W.CORNERSTONE-ENGR.COM <br />—13ROAF-17 T INFA- <br />WA6808 <br />EVERETT GOLF <br />& COUNTRY CLUB <br />6107 BERKSHIRE DRIVE <br />EVERETT, WA 98203 <br />SNOHOMISH COUNTY <br />—ISSUtU FUK: <br />CF CONSTRUCTION <br />,_REV.:DATE:=ISSUED FOR: BY:- <br />i v ` <br />03.08-18 <br />FINAL <br />DMO <br />Al02-28-18 <br />PRELIMINARY <br />DMO <br />=DRAWN BY:=CHK.: APV.: <br />DMOI MWO MWO <br />=CURRENT ISSUE DATE: <br />03-08-18 <br />SLS <br />e O <br />m 4iZ <br />32204 <br />�� alplcT <br />=JURISUIG 17UNAL APPROVAL: <br />PROPRIETARY INFORMATION: <br />DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY <br />ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br />ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS <br />DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br />THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS <br />IS PROPRIETARY BY NATURE- ANY USE OR DISCLOSURE <br />OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS <br />STRICTLY PROHBNED. <br />DRAWING TITLE: <br />GROUNDING DETAILS <br />=DRAWING NUMBER: <br />E-1.1 <br />0 <br />CEI JOB NUMBER: 5C/6C/4TXRX 17-09244 <br />
The URL can be used to link to this page
Your browser does not support the video tag.