KEY NOTES, <br />UEXISTING 127'-0' HIGH MONOPOLE <br />OEXISTING AT&T ANTENNA MOUNT, TYP. <br />3O NEW AT&T ANTENNA, TYP. <br />OEXISTING MASTER GROUND BAR AT BASE OF MONOPOLE <br />5 EXISTING MASTER GROUND BAR FINAL GROUND LEAD TO <br />EXISTING MONOPOLE GROUND RING <br />ANTENNA GROUNDING, #2 AWG STRANDED GREEN <br />O INSULATED COPPER CONDUCTOR TO COLLECTION <br />GROUND BAR AT ANTENNA LEVEL OF MONOPOLE <br />(D NOT USED <br />OEXISTING COLLECTION GROUND BAR FINAL GROUND LEAD, #2 AWG STRANDED GREEN INSULATED COPPER <br />CONDUCTOR TO MASTER GROUND BAR AT BASE OF <br />MONOPOLE <br />OEXISTING COLLECTION GROUND BAR <br />SRRH GROUNDING, #2 AWG STRANDED GREEN <br />10 INSULATED COPPER CONDUCTOR TO COLLECTION <br />GROUND BAR AT ANTENNA LEVEL OF MONOPOLE <br />6 <br />I a, <br />10 \ \ <br />\ B <br />% \ <br />\ 1 \ <br />� \ 1 <br />� \ 1 <br />\ 1 4 <br />\ � I <br />\ O <br />GENERAL GROUNDING NOTES- <br />1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND <br />CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. <br />2. ALL GROUNDING SHALL CONFORM TO THE CURRENT AT&T STANDARDS. <br />3. CONDUIT ROURNGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO <br />EQUIPMENT IS NOT BLOCKED. <br />4. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND <br />CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR <br />DAMAGE TO THE CONDUIT. <br />5. PREFABRICATED SHELTER WILL BE PROVIDED WITH INTERNAL WIRING AND EQUIPMENT INSTALLED. <br />FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS PROVIDED BY SHELTER <br />MANUFACTURER. <br />6. FOR INTERIOR EQUIPMENT LAYOUT AND LOCATION, SEE SHELTER MANUFACTURER'S DRAWINGS AND <br />SPECIFICATION. IN CASE OF CONFLICT THE DRAWINGS GOVERN. <br />7. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). <br />8. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING TWO <br />(2) HIGH PRESS CRIMPS. <br />9. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A <br />VERTICAL SEPARATION OF 6' FOR EVERY ADDITIONAL CONNECTION. <br />10. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING SURFACES AND <br />INSTALL PER MANUFACTURER'S RECOMMENDATIONS. ALL EXTERIOR GROUND CONNECTIONS SHALL BE <br />COATED WITH A CORROSION RESISTANT MATERIAL. <br />11. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG TIN PLATED COPPER UNLESS OTHERWISE <br />INDICATED. <br />12. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, i1010-Fr. LONG, AND <br />SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18' BELOW FINAL GRADE OR 6' BELOW FROST <br />LINE FOR MAXIMUM DEPTH. <br />13. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO <br />BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. <br />14. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN <br />45'BENDS CAN BE ADEQUATELY SUPPORTED. <br />15. GROUND RING SHALL BE LOCATED A MINIMUM OF 24' BELOW GRADE OR 6' MINIMUM BELOW <br />THE FROST LINE. <br />16. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0' FROM EQUIPMENT <br />CONCRETE PAD, SPREAD FOOTING, OR FENCE. <br />17. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED <br />SPRAY. <br />10. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING <br />19. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS <br />OR AT GROUNDING POINTS PROVIDED (2 MINIMUM) <br />20. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. <br />21. MINIMUM BENDING RADIUS FOR GROUNDING CONDUCTORS IS 8' WHEN BENDING IS <br />NECESSARY. GROUND CONDUCTORS ARE TO BE AS STRAIGHT AS POSSIBLE. <br />22. NO SPLICES PERMITTED IN GROUND CONDUCTORS. <br />23. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SPECIFIED <br />VALUES. <br />24. GROUND BARS SHALL NOT BE FIELD MODIFIED. <br />25. ALL HORIZONTAL FENCE SECTIONS TO BE GROUNDED WITH 8' SINGLE BARREL GROUND <br />STRAPS. <br />26. USE PANI SCHEME FOR LOADING ON MOB AS DISCUSSED IN NSTD 119, 33 & 36. <br />LE:GROUNDING NOTES I L <br />Schematic of Th eft Deterrent Solution at Cellular Site <br />LEGEND <br />Theft Deterrent Composite Cable. <br />ERLCO tCSAOsa (Ar&T Oort <br />Number. CEQI5.228, Rosenberger <br />Port Number: wR-ST'DC48LE•230) <br />#2 AWG Soli! Tinned Copper <br />Wire Bare, Below Grade <br />Coaxial and Other Feeders <br />a t & t <br />a4wn MY•rt0ol..t+� KYVV1tDY£.YEwaiO•trt T.4i't'tRRMD�t •O,MrMG . <br />.+w.va ro w rocccwc .•s r,F -, .. <br />-APua°- '�d-caWc�'rT --- <br />ac rm4mxo »Fr*sr <br />�tury or ATAraonoracmt <br />772 <br />TA,i <br />ANTENNA GROUNDING PLAN �;..;'�.A14.;;.-0 1 THEFT DETERRENT GROUND ARRANGEMENT I 22"x3a"SCALE: NONE i <br />I— 11"x17" SCALE: NONE 31 <br />N <br />1n <br />> <br />UUI <br />Z <br />O <br />3 <br />r <br />0 <br />to <br />O <br />0 <br />U_ <br />2> <br />NQ�y <br />LL <br />W� <br />Z� <br />W°_' <br />0 <br />Oc <br />C"P+ <br />ASSOCIATES <br />1-111 40TH AVE, W., SUITE 304 <br />LYNNWOOD• WA 98036 <br />PHONE: (425) 740-6392 <br />FAX: (425) 224-1614 <br />W W W.CAMPASSOC.COM <br />DATE: 02/03/16 <br />DRAWN BY: EAT <br />CHECKED BY: PIN <br />REVISIONS <br />REV.: DATE: DESCRIPTION: BY: <br />Q <br />01/25/16 <br />ISSUED FOR <br />CID REVIEW <br />EAT <br />Qi <br />02/03/16 <br />ISSUED P FRORIT <br />FINALREGISTERED <br />EAT <br />ARCHI ECT <br />UL NI <br />OF ASHINGTON <br />U2103120:6 <br />WA6808 EVERETT GOLF AND <br />COUNTRY CLUB <br />6107 BERKSHIRE DRIVE <br />EVERETT, WA 98203 <br />SHEET TITLE <br />ANTENNA GROUNDING PLAN <br />AND NOTES <br />SHEET NUMBER <br />E-1 <br />JOB NO. SWGM <br />