My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6107 BERKSHIRE DR A T AND T ANTENNA 2021-12-10
>
Address Records
>
BERKSHIRE DR
>
6107
>
A T AND T ANTENNA
>
6107 BERKSHIRE DR A T AND T ANTENNA 2021-12-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2021 9:41:13 AM
Creation date
12/9/2021 9:41:50 AM
Metadata
Fields
Template:
Address Document
Street Name
BERKSHIRE DR
Street Number
6107
Tenant Name
A T AND T ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EQUIPMENT CHASSIS: -(2) 318"0 SS HEX NUT HYLUG CONNECTOR INSTALLATION <br />GROUNDING BUSS BAR INSTRUCTIONS: <br />CABLE RACEWAY (#2) TWO HOLE 1 <br />COMPRESSION LUG SELECT PROPER HYLUG FOR THE WIRE SIZE USED - <br />COMPRESSION STRIP CABLE OF INSULATION TO A LENGTH EQUAL <br />GROUND WIRE STUD (TYP OF 2 @ TO THE BARREL OF THE CONNECTOR. <br />NO -LUX ANTI -OXIDIZING FRONT AND BACK OF CABINET) 3 INSERT CABLE FULLY INTO CONNECTOR <br />COMPOUND 4 APPLY THE PROPER NUMBER OF CRIMPS AS <br />SHOWN BY NUMBER OF COLORED BANDS. <br />CLEAR HEAT SHRINK ON 5. CRIMP FROM TONGUE END OF CONNECTOR <br />COMPRESSION LUGS TOWARD CABLES FOR TERMINALS AND CENTER <br />SPLICE TOWARD CABLE FOR BUTT SPLICES <br />318"0 STAR WASHER #2 STRANDED GREEN REQUIRING MORE THAN ONE CRIMP PER END <br />INSULATED COPPER GROUND <br />LEAD TO BUSS BAR OR #2 HYLUG TYPE YGA CONNECTOR IS PRE -FILLED WITH <br />SOLID BARE TINNED COPPER PENETROX COMPOUND AND STRIP SEALED <br />PLAN TO (E) GROUNDING SYSTEM <br />BURNDY HYDRAULIC DIE SET #U1CRT-1A111T <br />NOTE: <br />FOR GROUNDING CONNECTIONS TO PAINTED CABINETS <br />CHASSIS. GRIND OFF ALL ENAMEL COATINGS TO BARE METAL <br />AT LUG CONTACT AREA PRIOR TO MAKING BOLTED LUG <br />CONNECTION. APPLY NO -LUX TO ALL EXPOSED BARE METAL <br />NOT USED 2 NOT USED GROUND LUG CONNECTION <br />22x34 SCALE: NTS ',xi7 SCALE: NTS 22x34 SCALE: NTS tix17 SCALE: NTS 22x34 SCALE: NTS 1 11x17 SCALE: NTS <br />GROUND BAR ATTACHMENT: COAXIAL GROUND KITS W7 <br />LONG BARREL COMPRESSION <br />CONCRETE SUBSTRATE: (4) 3!8"0 HILTI TZ EXPANSION ANCHORS DOUBLE LUGS, ATTACH TO <br />WITH 2" MINIMUM EMBEDMENT. GROUND BAR & INSTALL BY <br />ANTENNA CONTRACTOR <br />WOOD FRAMED SUBSTRATE: (4) &B"O LAG SCREWS WITH Z" MINIMUM (CADWELD TYPE-GL) <br />EMBEDMENT (ADD BLOCKING IF <br />NECESSARY. <br />CLEAR HEAT SHRINK 4"x 24-x 1I4" THK COPPER <br />SOLID CMU WALL (4) 318"0 HILT] TZ EXPANSION ANCHORS ON COMPRESSION LUGS / GROUND BAR. INSTALLED <br />WITH 2" MINIMUM EMBEDMENT. BY GENERAL CONTRACTOR <br />HOLLOW CMU WALL (4) 318"$HILTI HIT HY-20 WITH HIT -A O��' <br />STANDARD RODS. (3 318" EMBEDMENT) 0 0 0 0 4,0 <br />0 0 0 0 0 0 0 0 0 0 0 0 + <br />NOTE: 00000000000aa000 <br />COAT ALL MECHANICAL CONNECTIONS O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 <br />cm <br />WY "NO -LUX" OR APPROVED EQUAL O O 0 0 0 0 0 0 0 O O C 0 0 0 t: <br />I° <br />za- <br />FIELD VERFY <br />02 SOLID BARE T9#*D �. <br />COPPER WIRE CWWEMMPE-GL) <br />TYPICAL GROUND BUSS BAR CONNECTIONS 7 <br />2204 SCALE: NTS 11x17 SCALE: NTS <br />TYPE GL LUG <br />TYPE GR 4� <br />TYPE PT <br />i Lq <br />. Y <br />TYPE GT TYPE SS <br />TYPE VS <br />NOTE: <br />CADWELD "TYPES' SHOWN ABOVE ARE EXAMPLES -CONSULT <br />WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS <br />TO BE USED FOR THIS PROJECT <br />CADWELD DETAIL 4 NOT USED 3 NOT USED <br />22x34 SCALE NTS I Nx17 SCALE- NTS I 22x34 SCALE, NTS 11x17 SCALE: NTS 1 22x34 SCALE. NTS 11x17 SCALE NTS <br />at&t <br />Your world. Delivered. <br />=PLANS PREPARED BY. <br />�E COr�lERSTONE <br />18928 WOODINVILLr-REDMOND RD NE. SUITE 210 <br />WOOO:NV LE, WA 98772 <br />PHONE: 425.467,1732 <br />WWV1 CORNERSTONE-ENGRCOIA <br />=PROJECT INFO: <br />WA6808 <br />EVERETT GOLF <br />& COUNTRY CLUB <br />6107 BERKSHIRE DRIVE <br />EVERETT, WA 98203 <br />SNOHOMISH COUNTY <br />=ISSUED FOR. <br />CONSTRUCTION <br />=REV.:DATE:-ISSUED FOR: BY.J <br />Q03-03-17 <br />FINAL <br />DMO <br />LIN02-23-17 <br />PRELIMINARY <br />DMO <br />DRAWN BY'-CHK.: APV.: <br />DNO I MWO MWO <br />=CURRENT ISSUE DATE: <br />03-03-17 <br />=LICFNSURF <br />�13yES L t YV <br />1 <br />N <br />32 <br />. � 4 <br />►►Vir <br />=JURISDICTIONAL APPROVAL: <br />=PROPRIETARY INFORMATION: <br />DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERY <br />MI DIMENSIONS AND AOVSE CONSLRTANTSOF ANY <br />ERRORS AND OMZSSONS At PREVIOUS:SSUES OF T46 <br />DRAWING ARE SUPERSEDED BY THE LATEST REVISION <br />THE IWORMA1x1N CONTA"ED W TH6 SET OF DOCLINENTS <br />IS PROPRETARY BY NATURE. ANY USE OR DISCLOSLIRE <br />OTHER THAN WHKX/ G RELATED TO NAMED CLIENT G <br />STR!-Z;TLY PROHIBITED. <br />=DRAWING TITLE: <br />GROUNDING DETAILS <br />=DRAWING NUMBER: <br />E-1.1 <br />0 <br />CEI JOB NUMBER: LTE 3C-4C 16-09217 <br />u�i <br />