GENERAL NOTES: <br />1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF <br />DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED <br />OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL <br />MATERIALS, EQUIPMENT. LABOR. AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE <br />PROJECT AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. <br />2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALLVSIT THE JOB SITE TO <br />FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT, <br />CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT <br />DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE <br />ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, <br />OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE <br />ARCHITECT/ENGINEER VERBALLY AND IN WRITING. <br />3. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION <br />AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK, CONTRACTORS BIDDING THE JOB <br />ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR <br />SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND <br />IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL <br />BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECTIENGINEER OF ANY <br />CONFLICTS. ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE <br />EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE <br />WORK UNLESS DIRECTED OTHERWISE. <br />4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT <br />DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION <br />MEANS, METHODS, TECHNIQUES. SEQUENCES, AND PROCEDURES FOR COORDINATING ALL <br />PORTIONS OF THE WORK UNDER THE CONTRACT. <br />6. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO <br />MANUFACTURER'SNENDORS SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL <br />CODES OR ORDINANCES TAKE PRECEDENCE. <br />6. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT <br />ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS. AND ORDINANCES. CONTRACTOR <br />SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND <br />LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS. <br />AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK <br />7. GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION <br />DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR USE <br />BY ALL PERSONNEL INVOLVED WITH THE PROJECT. THIS SET IS A VAUD CONTRACT DOCUMENT <br />ONLY IF THE TITLE SHEET IS STAMPED "FOR CONSTRUCTION" AND EACH SUCCESSIVE SHEET BEARS <br />THE ARCHITECTS SIGNED WET STAMP. <br />& THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE <br />ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE <br />9. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL <br />APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE <br />10. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN <br />2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING <br />CONSTRUCTION. <br />11. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, <br />EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK <br />CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION <br />ON OR ABOUT THE PROPERTY. <br />12. CONTRACTOR SHALL KEEP GENERAL WORKAREA CLEAN AND HAZARD FREE DURING <br />CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR SHALL REMOVE <br />EQUIPMENT NOT SPECIFIEDAS REMAINING ON THE PROPERTY OR PREMISES, SITE SHALLSE LEFT <br />IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. <br />13. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH <br />CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE <br />CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. <br />14. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID <br />DISTURBING NORMAL BUSINESS. <br />15. THE CONTRACTOR SHALL PROVIDE THE CLIENT PROPER INSURANCE CERTIFICATES NAMING <br />CLIENT AS ADDITIONAL INSURED, AND CLIENT PROOF OF LICENSE(S) AND PE 8 PD INSURANCE. <br />16. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL INSPECTIONS. <br />17, CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION <br />SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF <br />48 HOURS PRIOR TO CONSTRUCTION. DIAL 811. <br />1S CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO CLIENT <br />ALONG WITH REDLINED CONSTRUCTION SET. <br />19. CONTRACTOR TO DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP (REOUNING) THE <br />APPROVED CONSTRUCTION SET AND SUBMITTING THE REDLINED SET TO THE CLIENT UPON <br />COMPLETION. <br />20. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE. FOR PARTICIPATION IN BID <br />WALK <br />21. GENERAL CONTRACTOR IS TO COORDINATE ALL POWER INSTALLATION WITH POWER COMPANY AS <br />REWIRED. CONTRACTOR TO REPORT POWER INSTALLATION COORDINATION SOLUTIONS) TO <br />NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT. <br />22. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST: BE APPROVED BY CLIENT <br />CONSTRUCTION MANAGER. <br />Za IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE <br />PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, THE GENERAL CONTRACTOR SHALL <br />COORDINATE WITH BUILDING OWNER AND BUILDING ROOFING CONTRACTOR OF RECORD FOR <br />INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF, AND HAVE THE WORK <br />GUARANTEED UNDER THE ROOFING CONTRACTOR'S WARRANTY FOR MOISTURE PENETRATION OR <br />AND OTHER FUTURE BREACH OF ROOFING INTEGRITY. <br />24. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN CONCEALED <br />(SHROUDED) SUPPORT FRAMES OR TRIPODS, THE GENERAL CONTRACTOR SHALL COORDINATE <br />WITH THE FRP DESIGNERIFABRICATOR TO ENSURE THAT THE FINAL FRP SHROUD IS SIMULATING (IN <br />APPEARANCE) DESIGNATED EXISTING EXTERIOR BUILDING FACADE MATERIALS, TEXTURES AND <br />COLORS. THE CONTRACTOR SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK <br />FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTO SIMULATIONS ARE PROVIDED, THE <br />CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED IN <br />PHOTO SIMULATIONS. SHOP DRAWINGS SHALL BE PROVIDED TO THE GENERAL CONTRACTOR, <br />CONSTRUCTION COORDINATOR, AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION. <br />26. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE <br />ANCHORING TO A CONCRETE ROOF SLAB IS REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR TO <br />SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE <br />PRESENCE OF POST TENSION TENDONS WITHIN THE ROOF SLAB -RESULTING FROM AN <br />UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT DRAWING SET"- HAVING <br />INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE W/EMBEDDED STEEL <br />REPAR. IN THE EVENT POST TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE <br />PROVISIONS FOR X-RAY PROCEDURES (INCLUDED IN BID) FOR ALL PENETRATION AREAS WHERE <br />ANCHORING OCCURS. <br />20. GENERAL 8 SUBCONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL CABLE <br />TRAY TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS (WHERE APPLICABLE). PLASTIC ZIP TIES <br />SHALL NOT BE PERMITTED FOR USE ON CLIENT PROJECTS. RECOMMENDED MANUFACTURE SHALL <br />BE: PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S-CP UNDER SERIES-3N (OR EQUAL). <br />PANDUIT PRODUCT DISTRIBUTED BY TRIARC OF TACOMA, WA. <br />DESIGN CRITERIA: <br />THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH THE 2016 INTERNATIONAL <br />BUILDING CODE WITH WASHINGTON STATE BUILDING CODE AMENDMENTS (20151BC) <br />DESIGN LOADS: <br />DESIGN DATA FOR THE CITY OF EVERETT, WA: <br />-ROOF SNOW LOAD N/A (NOT A ROOFTOP SOLUTION) <br />-BASIC WIND SPEED 110 MPH (3 SEC GUST) <br />-WIND EXPOSURE B <br />CODE COMPLIANCE: <br />ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE <br />CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. <br />NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE <br />CODES. <br />BUILDING/DWELLING CODE 2015 ISC (STATE BUILDING CODE, WAC CHAPTER 51.60) <br />20151RC (STATE BUILDING CODE. WAC CHAPTER 51-61) <br />STRUCTURAL CODE 20151BC (STATE BUILDING CODE, WAC CHAPTER 6150) <br />MECHANICALCODE 20151MC (STATE BUILDING CODE, WAC CHAPTER 61-52) <br />ELECTRICAL CODE 2014 NEC (DEPT. OF LABOR 81NOUSTIRES, WAC CHAPTER 20646A) <br />FIREAJFE SAFETY CODE 20151FC (STATE BUILDING CODE, WAC CHAPTER 51.64A) <br />FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE <br />NOT REQUIRED IN ACCORDANCE WITH THE IBC 2016 BUILDING CODE. <br />CONCRETE NOTES: <br />1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI.318. <br />2. CONCRETE SHALL BE MIXED, PROPORTIONED. CONVEYED AND PLACED IN ACCORDANCE WITH <br />CHAPTER 19 OF THE 201516C. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS <br />FOLLOWS. <br />TYPE OF CONSTRUCTION 28 DAY STRENTHS W/C MNXMUM CEMENT <br />(Tc) RATIO CONTENT <br />PER CUBIC YARD <br />A. SLABS ON GRADE 2,600 PSI s 0.45 5 SACKS <br />TOPPING SLABS <br />CONCRETE PIERS <br />S. ALL STRUCTURAL CONCRETE 4,000 PSI s OAS 6 1/2 SACKS <br />EXCEPT WALLS <br />C. CONCRETE WADS 4.000 PSI S OAS 6 12 SACKS <br />CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE 4 U.N.O. <br />2. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND <br />PROCEDURES OF CONCRETE PLACEMENT. <br />3. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR�ENTRAINED WITH AN <br />AIR -ENTRAINING AGENT CONFORMING TO ASTM C260. C494,0618, CM AND C1017. TOTALAIR <br />CONTENT SHALL BE IN ACCORDANCE WITH TABLE IOD42 OF THE 201516C. <br />4. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT Si), GRADE 60. <br />fy-60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE <br />GRADE 40. fy-40,000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED <br />SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A816(S1) MAY BE WELDED <br />ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES <br />SPECIFIED IN A.W.S. D14 ARE SUBMITTED. <br />5. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND RENDS) IN ACCORDANCE WITH <br />ACI 316 AND 318. LAP ALL CONTINUOUS REINFORCEMENT T 0 E EMENT AT LEAS 30 BAR DIAMETERS OR A <br />MINIMUM OF Z-V. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP <br />CORNER BARS AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF Z-W. LAP ADJACENT MATS OF <br />WELDED WIRE FABRIC A MINIMUM OF 8' AT SIDES AND ENDS. <br />6. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />7. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 00. ",000 <br />PSL <br />8. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS <br />SPECIFICALLY SO DETAILED OR APPROVED BY THE CONSULTANT, <br />10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: <br />- CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" <br />- CONCRETE EXPOSED TO EARTH OR WEATHER <br />(#6 BARS OR LARGER) 2" <br />(#6 BARS OR SMALLER) 1 12- <br />-CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND <br />(SLABS, WALLS AND JOISTS) (#I1 BARS AND SMALLER) 314" <br />(BEAMS. COLUMNS) (PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS) 1 12" <br />It BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. <br />12. ANCHOR BOLTS TO CONFORM TO ASTM A307. <br />13. NONSHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE. <br />MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED <br />RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH <br />IT IS PLACED (3,000 PSI MINIMUM). <br />14. ALLEXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS REWIRE TESTING TO <br />CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER <br />STRUCTURAL STEEL NOTES: <br />SYMBOLS AND ABBREVIATIONS <br />AC <br />AIR CONDITIONING <br />MAX <br />MAXIMUM <br />1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR <br />AGL <br />ABOVE GRADE LEVEL <br />MECH <br />MECHANICAL <br />REVIEW PRIOR TO FABRICATION. <br />APPROX <br />APPROXIMATELY <br />MTL <br />METAL <br />MFR <br />MANUFACTURE <br />2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING, HIGH <br />BLDG <br />BUILDING <br />MGR <br />MANAGER <br />STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION ANCHORS) SHALL BE <br />BLK <br />BLOCKING <br />MIN <br />MINIMUM <br />BASED ON THE A.I.S.I. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF <br />B.O. <br />BOTTOM OF <br />MISC <br />MISCELLANEOUS <br />STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION. SUPERVISION SHALL BE IN ACCORDANCE <br />B.O.S. <br />BOTTOM OF STEEL <br />WITH20151BC CHAPTER 22. BYA QUAUFIED TESTING AGENCY DESIGNATED BY THE CONSULTANT. <br />NIA <br />NOT APPLICABLE <br />THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST <br />CLG <br />CEILING <br />NIC <br />NOT IN CONTRACT <br />RESULTS. <br />CIA <br />CLEAR <br />N.S. <br />NEAR SIDE <br />CMU <br />CONCRETE MASONRY UNIT <br />NTS <br />NOT TO SCALE <br />3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: <br />CONC <br />CONCRETE <br />CONST <br />CONSTRUCTION <br />O.C. <br />ON CENTER <br />TYPEOFMEMBER <br />CONT <br />CONTINUOUS <br />O.D. <br />OUTSIDE DIAMETER <br />OM <br />OVERHEAD <br />A. WIDE FLANGE SHAPE ASTM A992, Fy 50 KSI <br />DBL <br />DOUBLE <br />S. OTHER SHAPE, PLATES AND ROD ASTM A38, Fy 36 KSI <br />DIA/0 <br />DIAMETER <br />PLCS <br />PLACES <br />C. PIPE COLUMNS ASTM A53, Fy 35 KSI <br />DIAG <br />DIAGONAL <br />PLYWD <br />PLYWOOD <br />D. STRUCTURAL TUBING ASTM A600, Fy46 KSI <br />DN <br />DOWN <br />PROJ <br />PROJECT <br />E. ANCHOR BOLTS ASTM A307 <br />GET <br />DETAIL <br />PROP <br />PROPERTY <br />F. CONNECTION BOLTS ASTM A326 <br />DWG <br />DRAWING <br />PSF <br />POUNDS PER SQUARE FOOT <br />PSI <br />POUNDS PER SQUARE INCH <br />4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER A123/A123M-13. <br />EA <br />EACH <br />PT <br />PRESSURE TREATED <br />EL <br />ELEVATION <br />5. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.I. AND AWS STANDARDS AND SHALL BE <br />ELEC <br />ELECTRICAL <br />RAD <br />RADIUS <br />PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70 XX ELECTRODES. ONLY PREQUAL FIED <br />EQ <br />EQUAL <br />REQ <br />REQUIRED <br />WELDS (AS DEFINED BY AWS) SHALL BE USED. WELDING OF GRADE 60 REINFORCING BARS (IF <br />EQUIP <br />EQUIPMENT <br />RM <br />ROOM <br />REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 <br />E.W. <br />EACH WAY <br />RO <br />ROUGH OPENING <br />REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E70 XX ELECTRODES. WELDING <br />EXT <br />EXTERIOR <br />WITHIN 4' OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE <br />SCH <br />SCHEDULE <br />FOR MATERIAL REQUIREMENTS OF WELDED BARS. <br />FIN <br />FINISH <br />SHT <br />SHEET <br />FLUOR <br />FLUORESCENT <br />SIM <br />SIMILAR <br />6. COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE SHOWN ON <br />FLR <br />FLOOR <br />SPEC <br />SPECIFICATION <br />THE PLANS. PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL COLD -FORMED STEEL <br />F.S. <br />FAR SIDE <br />SF <br />SQUARE FOOT <br />FRAMING SHALL CONFORM TO THE A.I.S.I. "SPECIFICATION FOR THE DESIGN OF COLD -FORMED <br />FT <br />FOOT <br />SS <br />STAINLESS STEEL <br />STEEL STRUCTURAL MEMBERS.* <br />STL <br />STEEL <br />GA <br />GAUGE <br />STRUCT <br />STRUCTURAL <br />7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (aW DIA.) AND SHALL HAVE A <br />GALV <br />GALVANIZED <br />STD <br />STANDARD <br />MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. <br />G.C. <br />GENERAL CONTRACTOR <br />SO FT <br />SQUARE FOOT <br />GRND <br />GROUND <br />SQ IN <br />SQUAREINCH <br />8. NONSTRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE ST'DIA. ASTM A307 BOLTS <br />GYP BD <br />GYPSUM WALLBOARD <br />SUSP <br />SUSPENDED <br />UNLESS NOTED OTHERWISE. <br />HORZ <br />HORIZONTAL <br />THK <br />THICK <br />9. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE DESIGN 8 CONSTRUCTION <br />HR <br />HOUR <br />THRU <br />THROUGH <br />SPECIFICATION AND IN ACCORDANCE WITH ASTM A36 UNLESS NOTED OTHERWISE. <br />HT <br />HEIGHT <br />TNNG <br />TINNED <br />HVAC <br />HEATING VENTILATION <br />T.O. <br />TOP OF <br />10. ALL WELDS TO BE 1/4' FILLET UNLESS NOTED OTHERWISE. <br />AIR CONDITIONING <br />T,O.S. <br />TOP OF STEEL <br />TYP <br />TYPICAL <br />11. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COA78 OF GALVACON(ZINC RICH PAINT) OR <br />I.D. <br />INSIDE DIAMETER <br />APPROVED EQUAL. <br />IN <br />INCH <br />UNO <br />UNLESS NOTED OTHERWISE <br />INFO <br />INFORMATION <br />TOWER/POLE NOTES: <br />NSUL <br />INSULATION <br />VERT <br />VERTICAL <br />INT <br />INTERIOR <br />V.I.F. <br />VERIFY N FIELD <br />IBC <br />INTERNATIONAL BUILDING CODE <br />1. VERIFICATION THAT THE PROPOSED TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA <br />W/ <br />WITH <br />LOADING IS TO BE DONE BY OTHERS. <br />LBS <br />POUNDS <br />W/0 <br />WITHOUT <br />WP <br />WATERPROOF <br />2. PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INITIALAND <br />FUTUREANTENNAS. ANTENNA COAX CABLES ARE TO BE SUPPORTED AND RESTRAINED AT THE <br />CENTERS SUITABLE TO THE MANUFACTURER'S REQUIREMENTS. <br />ABBREVIATED ROOFTOP SAFETY PROCEDURES <br />R <br />PLATE Q o <br />D Q- <br />CHAIN -LINK FENCE <br />(WHEN APPLICABLE): <br />4, <br />CENTERLNE <br />O O <br />D O <br />CHAIN -LINK FENCE W/ BARB WIRE <br />WOOD FENCE <br />(E) <br />EXISTING T <br />T <br />- TELEPHONE <br />(AS PER 'ACCIDENT PREVENTION PROGRAM"- BY PERMISSION OF WREN CONSTRUCTION, INC.- <br />- P <br />- P <br />- POWER - <br />03A1M�) <br />N <br />DETAIL NUMBER _ _ _ _ _ <br />_ - - - <br />- - GROUND WIRE <br />FALL PROTECTION METHODS AND EQUIPMENT <br />X'N <br />SHEET NUMBER <br />COAX <br />COAXIAL CABLE <br />ROOF TOP INSTALLATIONS <br />1 . FOR WORK BEG PERFORMED WITHIN 25'OF AN UNPROTCTED RF EDGE. <br />SPECIAL <br />INSPECTIONS: <br />CONSSTRUCIS <br />TIONSUPERVSORSHALL DESIGNATE ATRANEDSAFETYMONTORTOOBSERVETHE <br />MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION WORKERS. <br />SPECIAL <br />INSPECTIONS IN ACCORDANCE WITH 20151BC SECTION 1704. <br />2. SAFETY MONITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (LE. BACKING UP TOWARE <br />A ROOF EDGE, ETC.) OR UNSAFE ACTIVITIES. THE SAFETY MONITOR MUST BE ON THE SAME ROOF <br />SOILS/GEOTECHNICAL: <br />AND WITHIN VISUAL AND VERBAL DISTANCE OF THE CONSTRUCTION WORKERS. <br />OSHORING INSTALLATION AND MONITORING <br />DOBSERVE AND MONITOR EXCAVATION <br />3. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN V OR LESS OF AN UNPROTECTED <br />❑VERIFY SOIL BEARING <br />psf BEARING <br />ROOF EDGE, REWIRES WORKERS TO USE SAFETY LINE. <br />❑SUBSURFACE DRAINAGE PLACEMENT <br />4. SAFETY LINE SHALL BE MINIMUM W DIAMETER NYLON. WITH NOMINAL TENSILE STRENGTH OF <br />OVERIFY FILL MATERIAL AND COMPACTION <br />5400 Les. <br />❑VERIFY CONDITIONS AS ANTICIPATED <br />DPILE PLACEMENT (AUGER CASTIDRIVEN PILE) <br />5. SAFETY LINE SHALL BE ATTACHED TO SUBSTANTIAL MEMBER OF THE STRUCTURE. <br />❑OTHER <br />8. SAFETY LINE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO REACH EDGE OF <br />ROOF. BUT NOT BEYOND. <br />REINFORCED CONCRETE: <br />❑REINFORCING STEEL AND CONCRETE PLACEMENT <br />7. SAFETY BELTS SHALL BE woan BY ALL CONSTRUCTION WORKERS. <br />❑PRESTRESSEDIPRECAST CONCRETE FABRICATION AND ERECTION <br />OBATCH PLANT INSPECTION <br />8. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION EQUIPMENT SHALL <br />OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES, tNCLUDING: <br />❑SHOTCRETE <br />OGROUTING <br />INSPECTION OF CONSTRUCTION AREA FOR HAZARDS <br />❑OTHER <br />USE OF AN INSPECTION CHECKLIST <br />INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS <br />STRUCTURAL STEEL: <br />REPORTING AND DOCUMENTING ANY HAZARDS <br />REPORTING HAZARDS TO THE SAFETY COMMITTEE FOR CONSIDERATION <br />DFABRICATION AND SHOP WELDS <br />POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN <br />❑ERECTION AND FIELD WELDS AND BOLTING <br />RECEIVING AN UNBIASED REVIEW OF ONE'S OWN WORK AREA BY ANOTHER COWORKER SAF <br />OOTHER <br />REPRESENTATIVE <br />REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL <br />NATIONAL ASSOCIATION OF TOWER ERECTORS 2000 PUBLICATION <br />STRUCTURAL ALUMINUM: <br />DFABRICATION AND SHOP WELDS <br />REFERENCED OSHA REGULATIONISTANDARDS SHALL BE REVIEWED BY TOWER ERECTORS. <br />❑ERECTION AND FIELD WELDS AND BOLTING <br />EQUIPMENT INSTALLERS AND TOWER/ROOF TOP CONTRACTORWUBCONTRACTORS <br />DOTHER <br />29 CFR 1928.500 - SCOPE. APPLICATION, AND DEFINITIONS <br />29 CFR IWAZ01- DUTY TO HAVE FALL PROTECTION <br />19 CFR 1928,502 - FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES <br />STRUCTURAL <br />MASONRY' <br />CALL TWO WORKING DAYS <br />BEFORE YOU =1 <br />811 <br />NATIONAL UTILITIES UNDERGROUND LOCATE <br />aisflvonc twws�uu eE u�xcNeioer w,nw.aoncs•�.0 <br />rnE«a.wmncconnvx�vn s..,o, nc <br />F oaovosEn. <br />OCONTINUOUS <br />❑PERIODIC <br />OOTHER <br />OTHER: NONE REQUIRED <br />ANCHORING TO CONCRETE: <br />❑BOLTS INSTALLED IN CONCRETE <br />❑POST -INSTALLATION ADHESIVE ANCHORS <br />❑POST -INSTALLATION MECHANICAL ANCHORS <br />at&t <br />Your world. <br />:PLANS COZPREPARED BY: <br />)19TONE <br />NOIN{{RIN O, INC. <br />16928 WOODINVILLE-REDMOND RD NE, SUITE 210 <br />WOODINVILLE. WA98072 <br />PHONE: 426.487.1732 <br />W W W.CORNERSTONE-ENGR.COM <br />:PROJECT INFO: <br />WA6808 <br />EVERETT GOLF <br />& COUNTRY CLUB <br />6107 BERKSHIRE DRIVE <br />EVERETT, WA 98203 <br />SNOHOMISH COUNTY <br />:ISSUED FOR: <br />CONSTRUCTION <br />ZREV::DATE:=ISSUED FOR: BY:= <br />Qp <br />03-W18 <br />FINAL <br />DMO <br />Qq <br />02-28-18 <br />PRELIMINARY <br />ONTO <br />:DRAWN BY:=CHK.: APV.: <br />DMO I MWO MWO <br />:CURRENT ISSUE DATE: <br />03-08-18 <br />�SIEy <br />L it <br />DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY <br />ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br />ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS <br />DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br />THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS <br />IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE <br />OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS <br />STRICTLY PROHIBITED. <br />GENERAL NOTES <br />-noewlAlr_ A9 wcvo. <br />G-1 <br />0 <br />CEI JOB NUMBER: SC16C/4TXRX 17-09244 <br />)0 <br />