n <br />LJ <br />• <br />lair <br />EVE <br />R ETT WAC 296-46B-900; ELECTRICAL PLAN REVIEW <br />DIRECTIONS: Read the WAC section below to determine If plan review is required or not required. Then select the box next to (a) to <br />tell City Staff if plan review is not requded and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br />required, select the box next to (b) and (c) to acknowledge that plan review is required and the electrical plans have been provided <br />with this permit application. <br />if item (a)-(ll, III, or v) Is selected, the work must also comply with section (a)4vii). See arrow flow chart below, <br />(3) Electrical plan review. <br />✓� (a) Electrical plan review is not required for. <br />❑ (i) Low voltage systems; <br />t4—❑ (ii) Lighting specific projects that result In an electrical load reduction on each feeder involved in the project; <br />(lii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br />involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br />(iv) Stand-alone utility fed services that do not exceed 250 volts, 400 amperes where the projects distribution system <br />does not include: <br />(A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br />(B) An essential electrical system defined in NEC 517.2; or <br />(C) A required fire pump system. <br />(v) Modifications to existing electrical Installations where all of the following conditions are met: <br />(A) Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br />250 volts or for lighting circuits not exceeding 277 volts to ground; <br />(B) Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br />(C) Does not Involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br />and <br />(D) Service or feeder load calculations are increased by 5% or less. <br />❑ (vi) Electric power production source(s) such as solar photovoltaic, fuel cell, or wind electric system(s) with a total <br />rating of 9600 watts or less. <br />(vii) For installations in (a)(il), (ill), and (v) of this subsection to be considered, the following must be available <br />❑ to the electrical Inspector before the work is initiated: <br />(A) A clear and adequate description of the project's scope; <br />(B) A load calculalion(s); <br />(C) What the load changes are, providing both before and after panel schedules as needed, and <br />(D) Provide information showing that the service and feeder(s) supplying the panels) where the work is <br />taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br />for that supply. <br />NOTE: Electrical plan review is not required for "Medical, dental, and chiropractic clinic" of which is a clinic or <br />❑ physicians' office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br />(1)(c)(xii). <br />o(b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br />occupancies defined in this chapter. <br />(c) if a review is required, the electrical plan must be submitted for review and approval before the electrical work is begun. <br />T.bl. 00-? <br />Health or Paricaki tare Facilities <br />Hea➢th or Permmanal sere facility <br />Type <br />osc-exE <br />Numn5 home 4n,i or acne tin 3 <br />cars uM <br />Plan Review <br />Required <br />'res <br />res <br />$cardi;nj home <br />�Y@S <br />:,slued 11'Ing lacil.ty <br />ves <br />; rvhe'e altchCat Sm hosDita- <br />vss <br />?. rra,e mP�Yv)€amc holoas< <br />Yes <br />.Mate.-n.ty norre <br />Yes <br />Arr tru'at ry surgery °acairy <br />yes <br />Rena€ e ^Llai<ln€C <br />yea <br />e"�.eS:Cinaai g!l �tn°e:vt :atrst}+ <br />`y@Y <br />2nhancfd afmce, fa<ii yr <br />Yes <br />Adult re5,denual reh,,Vitatiz, <br />;enter <br />Yey <br />Table 900-2 <br />Educational and Institutional Facilities, Places of <br />Assembly, or Other Facilities <br />Educational, Institutional, or <br />Plan Review <br />Other Facility Types <br />Required <br />mcuca:icna <br />Yes <br />Ir _:l:utlona' <br />Yes <br />Notes to Tables 900•1 and 900-2. <br />A City author _ed to do a ear cal rtspect•or:; <br />may requ re p.an re, + e= on fads .y rylaes not <br />reviF red by the d%a-tT.ent <br />PERMITO—L ` 1 ()g —0�) Page 2-Plan Review <br />