0 <br />MVJ <br />DIRECTIONS: Read the WAC section below to determine if plan review is required or not required. Then select the box next to (a) to <br />tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br />required, select the box next to (b) and (c) to acknowledge that plan review is required and the electrical plans have been provided <br />with this permit application. <br />-- If item (a)-(ii, iii, or v) is selected, the work must also comply with section (a)-(vii). See arrow flow chart below. <br />(3) Electrical plan review. <br />❑✓ (a) Electrical plan review is not required for: <br />D&I (i) Low voltage systems; <br />❑ (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br />(iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br />La involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br />❑ (iv) Stand-alone utility fed services that do not exceed 250 volts, 400 amperes where the project's distribution system <br />does not include: <br />(A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br />(B) An essential electrical system defined in NEC 517.2; or <br />(C) A required fire pump system. <br />(v) Modifications to existing electrical installations where all of the following conditions are met: <br />(A) Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br />250 volts or for lighting circuits not exceeding 277 volts to ground; <br />(B) Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br />(C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br />and <br />(D) Service or feeder load calculations are increased by 5% or less. <br />El rating <br />Electric power production source(s) such as solar photovoltaic, fuel cell, or wind electric system(s) with a total <br />rating of 9600 watts or less. <br />(vii) For installations in (a)(ii), (iii), and (v) of this subsection to be considered, the following must be available'. <br />to the electrical inspector before the work is initiated: <br />(A) A clear and adequate description of the project's scope; <br />(B) A load calculation(s); <br />(C) What the load changes are, providing both before and after panel schedules as needed; and <br />(D) Provide information showing that the service and feeder(s) supplying the panel(s) where the work is <br />taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br />for that supply. <br />NOTE: Electrical plan review is not required for "Medical, dental, and chiropractic clinic" of which is a clinic or <br />LJ physicians' office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br />(1)(c)(xii). <br />(b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br />occupancies defined in this chapter. <br />(c) If a review is required, the electrical plan must be submitted for review and approval before the electrical work is begun. <br />Table 900.1 <br />Health or Personal Care Facilities <br />Health or Personal Care Facility <br />Type <br />an Review <br />Required <br />.VPSIII> home i,nq cr Icng-tern• <br />C3rZ y'It <br />'%es <br />aiCt)1101 11) ho<_'p:tal <br />`(E: <br />'',totemic" <br />Yn <br />Aml:��ato +-uq;e,yrad' <br />nerno d o.ysi' C`In:-- <br />-iriin e:j c.al v EdmGn.it faci;i", <br />Ye5 <br />ru+a'•.ed sENk s f8ci itl+ <br />Adl., It renti + 1ha'o�.�tat':on <br />t--s <br />Table 900-2 <br />Educational and Institutional Facilities, Places of Assembly, or other Facilities <br />Educational, Institutional, or Plan Review <br />Other Facility Types Required <br />_rt:cat'ona' <br />n titU_Icnai <br />Notes to Tables 900-1 and 900-2, <br />. A Cit� a t..o r Ze„ tIC t. ? L ',f 31 1:: 1..r(' ;:•; <br />may roqulre pi n e/, ev, or faci'n.y ;t-ces not <br />Viev"F." by thie <br />PERMIT p r� `Oe�[ t 3L� Page 2-Plan Review <br />