Laserfiche WebLink
FORTE MEMBER REPORT Level,upper floor-worst case PASSED <br /> 1 piece(s)11 7/8"TM®110 @ 16"OC <br /> Overall Length: 15' 7" <br /> • <br /> 11 <br /> 1 15' <br /> El LI <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> I Design Results Actual to Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(Ibs) 533 @ 2 1/2" 1041(2.25") Passed(51%) 1.00 1.0 D+ 1.0 L(All Spans) Member Type:Joist <br /> r <br /> Shear(Ibs) 520 @ 3 1/2" 1560 Passed(33%) 1.00 1.0 D+ 1.0 L(All Spans) Building Use:Residential <br /> Moment(Ft-Ibs) 1994 @ 7'9 1/2" 3160 Passed(63%) 1.00 1.0 D+ 1.0 L(All Spans) Building Code:IBC 2015 <br /> live Load Defl.(in) 0.217 @ 7'9 1/2" 0.379 Passed(L/840) -- 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Total Load Deft.(in) 0.282 @ 7'9 1/2" 0.758 Passed(L/646) -- 1.0 D+1.0 L(All Spans) <br /> Ti-Pro'm Rating 51 40 Passed -- -- <br /> • Deflection criteria:LL(L/480)and TL(L/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 4'o/c unless detailed otherwise. <br /> •Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 15'5"o/c unless detailed otherwise. <br /> •A structural analysis of the deck has not been performed. <br /> •Deflection analysis is based on composite action with a single layer of 23/32"Weyerhaeuser Edge"'Panel(24"Span Rating)that is glued and nailed down. <br /> •Additional considerations for the TJ-Pro'"Rating include:1/2"Gypsum ceiling. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Flr Total Accessories <br /> Oreoo i <br /> 1-Stud wall-SPF 3.50" 2 25" 1.75" 125 416 541 1 1/4"Rim Board <br /> 12-Stud wall-SPF 3.50" 2.25" 1.75" 125 416 541 1 1/4"Rim Board <br /> •Rim Board Is assumed to carry all loads applied directly above it,bypassing the member being designed. <br /> Dead Floor Live <br /> Loads Location(Side) Spadng (0.90) (1.00) Comments <br /> 1-Uniform(PSF) 0 to 15'7` 16" 12.0 40.0 Residential-Living <br /> Areas <br /> 1 Weyerhaeuser Notes 1.0 SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Use of this software is not intended to circumvent the need for a design <br /> professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is <br /> compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> i Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES <br /> under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards.For current code evaluation reports, <br /> Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Forte Software Operator Job Notes 4/10/2019 12:03:26 PM <br /> Forte v5 4.Design Engine:V7 1 1 3 <br /> rill I i /,ror. c.1 V <br /> • <br /> 22agevf 1 <br />