Laserfiche WebLink
10/5/2021 Page <br /> City of Everett <br /> 8:14:20AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. P2109-027 Site Address 1620 RAINIER AVE <br /> Applied 9/20/2021 Applicant Nick Shelly Lot <br /> Approved 9/22/2021 Owner Nick Shelly Block <br /> Issued 9/22/2021 Contractor OWNER Tract <br /> Parent Permit No. Description Replace tub,sinks,faucets,toilets(upgrades) <br /> Notes Per inspector,we need to apply for a more generalized permit for updating fixtures <br /> Scheduled Completed Tvne Inspector Result Remarks Inspector's Comments <br /> 9/24/2021 9/24/2021 PLUMB 07-FINAL SDP CORRECTION eTRAKiT Inspection 9/23/2021 9:02 AM Nick Shelly <br /> Request <br /> Contact Name:Nick Shelly <br /> Site Address: 1620 RAINIER AVE <br /> Phone:4259545756 <br /> e-Mail:nicholas.shelly@gmail.com <br /> (9/24/2021 11:39 AM SDP) <br /> UPC 608.5-Water heater T&P drain line <br /> cannot be flexible pipe nor can it be <br /> reduced in size(pex fittings).Change the <br /> drain line to solid approved piping.Ok to <br /> pipe to 6"above the floor.See exception. <br /> 9/30/2021 9/30/2021 PLUMB 07-FINAL JJM CORRECTION (9/30/2021 9:29 AM JJM) <br /> Need to disconnect relief line from wall <br /> connection and hard pipe in CPVC or <br /> Copper to within 6"of floor per Shellies <br /> original allowance. <br /> No observed pex in crawl space at this time. <br /> 10/1/2021 10/1/2021 PLUMB 07-FINAL JJM APPRVD-PERK eTRAKiT Inspection 9/30/2021 5:59 PM Nick Shelly <br /> Request <br /> Contact Name:Nick Shelly <br /> Site Address:1620 RAINIER AVE <br /> Phone:4259545756 <br /> e-Mail:nicholas.shelly@gmail.com <br /> (10/1/2021 2:42 PM JJM) <br /> Relief run in CPVC to exterior.Ok final. <br /> INSP12 <br />