Laserfiche WebLink
1 31 4 1 5 1 6 <br />SYMBOLS LEGEND <br />North Arrow <br />E <br />NORTH <br />--------------------- <br />Dimensional Control <br />(:o <br />r + Grid <br />0 <br />Name Level Datum <br />Elevation <br />I Centerline Mark <br />+ Spot Elevation - Crosshair <br />Spot Elevation- Target Filled <br />User Note Location & Label <br />D Drawing Callout Types <br />A3.01 1 B Exterior Elevation Callout <br />1A <br />1 D A5.01 1 B Interior Elevation Callout <br />1C <br />1 / A101 Drawing Reference <br />CI <br />BI <br />Al <br />SIM <br />A101 Callout <br />SIM <br />1 <br />A101 Building Section <br />SIM <br />1 <br />A101 Wall Section <br />1 SIM <br />A101 Detail Section <br />Building Element Tags <br />00 00 00.0-01 Keynote Reference <br />Area name <br />150 SF Area Name & Square Footage <br />ROOM NAME Room Name & Number <br />101 <br />WS00 Wall Type <br />GA Storefront Type <br />101 Door Number <br />OWindow Type <br />O' - Q, Ceiling Elevation from Floor Level <br />RA_ Roof Assembly Type <br />Mark Casework Type <br />WHD <br />00 Material Mark <br />------------------------------ <br />Revisions <br />000 Revision Number <br />ued to <br />PROJECT TEA <br />Client <br />Everett Public Schools <br />3900 Broadway <br />Everett, WA 98201 <br />Contact: Darcy Walker <br />Phone: (425) 385 4197 <br />Email: dwalker@everettsd.org <br />Tenant rovement MONITORED AUTOMATIC FIRE <br />DETECTION SYSTEM REQUIRED <br />Hingh S <br />PROJECT Di <br />Everett <br />ARCHITECTURAL ABBREVIATIONS <br />ANGLE <br />& <br />AND <br />L. <br />LENGTH <br />AB <br />ANCHOR BOLT <br />LAV <br />LAVATORY <br />ACT <br />ACOUSTICAL CEILING TILE <br />LB <br />LAG BOLT <br />ADD <br />ADDENDUM <br />LKR <br />LOCKER <br />A.F.F. <br />ABOVE FINISH FLOOR <br />LS <br />LANDSCAPING <br />ALS <br />AREA LIGHT STANDARD <br />LVR <br />LOUVER <br />ALUM <br />ALUMINUM <br />ANOD <br />ANODIZED <br />MAT'L <br />MATERIAL <br />MAX <br />MAXIMUM <br />BC <br />BOTTOM OF CURB <br />MB <br />MARKERBOARD <br />BD <br />BOARD <br />MECH <br />MECHANICAL <br />BLDG <br />BUILDING <br />MED <br />MEDIUM <br />BLKG <br />BLOCKING <br />MEZZ <br />MEZZANINE <br />B.M. <br />BENCH MARK <br />MFR <br />MANUFACTURER <br />BM <br />BEAM <br />MH <br />MANHOLE <br />BOT <br />BOTTOM <br />MIN <br />MINIMUM <br />BTU <br />BRITISH THERMAL UNIT <br />MIR <br />MIRROR <br />BTWN <br />BETWEEN <br />MISC <br />MISCELLANEOUS <br />MTD <br />MOUNTED <br />OR C CHANNEL <br />MTL <br />METAL <br />CB <br />CATCH BASIN <br />CCTV <br />CLOSED CIRCUIT TV <br />NA <br />NOT APPLICABLE <br />CG <br />CORNER GUARD <br />NIC <br />NOT IN CONTRACT <br />C.I.P. <br />CAST IN PLACE <br />NOM <br />NOMINAL <br />CLG <br />CEILING <br />NS <br />NELSON STUD <br />CLR <br />CLEAR <br />NTS <br />NOT TO SCALE <br />CJ <br />CONTROL JOINT <br />CMU <br />CONCRETE MASONRY UNIT <br />OA <br />OVERALL <br />CONT <br />CONTINUOUS <br />OC <br />ON CENTER <br />CORR <br />CORRIDOR <br />O.D. <br />OVERFLOW DRAIN <br />CS.J <br />CONSTRUCTION JOINT <br />OD <br />OUTSIDE DIAMETER <br />CSMT <br />CASEMENT <br />OFCI <br />OWNER FURNISHED CONTRACTOR <br />CT <br />CERAMIC TILE <br />INSTALLED <br />CTR <br />CENTER <br />OFOI <br />OWNER FURNISHED OWNER <br />CENTERLINE <br />INSTALLED <br />OH <br />OVERHEAD <br />DBL <br />DOUBLE <br />OPNG <br />OPENING <br />DTL <br />DETAIL <br />OPP <br />OPPOSITE <br />DF <br />DRINKING FOUNTAIN <br />OS <br />OUTSIDE <br />DIA <br />DIAMETER <br />DIAL <br />DIAGONAL <br />PIP <br />POURED IN PLACE <br />DIM <br />DIMENSION <br />PL <br />PROPERTY LINE <br />DISP <br />DISPENSER <br />PLAS <br />PLASTER <br />DN <br />DOWN <br />PLYWD PLYWOOD <br />DP <br />DAMPROOFING <br />PSF <br />PER SQUARE FOOT <br />DR <br />DOOR <br />P.T. <br />PRESSURE TREATED <br />DS <br />DOWN SPOUT <br />PVMT <br />PAVEMENT <br />DT <br />DRAIN TILE <br />DWG <br />DRAWING <br />R. <br />RADIUS <br />R.D. <br />ROOF DRAIN <br />EA <br />EACH <br />REF <br />REFERENCE <br />EF <br />EXHAUST FAN <br />REFR <br />REFRIGERATOR <br />EJ <br />EXPANSION JOINT <br />REQ'D <br />REQUIRED <br />EL <br />ELEVATION <br />REV <br />REVISE OR REVISION <br />ELEC <br />ELECTRICAL <br />RM <br />ROOM <br />E.O.S. <br />EDGE OF SLAB <br />R.O. <br />ROUGH OPENING <br />ENGR <br />ENGINEER <br />RCP <br />REFLECTED CEILING PLAN <br />EP <br />ELECTRICAL PANEL <br />EQ <br />EQUAL <br />SB <br />SMART BOARD <br />EQUIP <br />EQUIPMENT <br />SC <br />SOLID CORE <br />ES <br />EACH SIDE <br />SECT <br />SECTION <br />EW <br />EACH WAY <br />SF <br />SQUARE FOOT <br />EXST <br />EXISTING <br />SHTG <br />SHEATHING <br />(E) <br />EXPANSION <br />SHWR <br />SHOWER <br />EXT <br />EXTERIOR <br />SHT <br />SHEET <br />SIM <br />SIMILAR <br />FA <br />FIRE ALARM <br />SJ <br />SEISMIC JOINT <br />FBO <br />FURNISHED BY OTHERS <br />SM <br />SHEET METAL <br />FD <br />FLOOR DRAIN <br />SPEC <br />SPECIFICATION <br />FDN <br />FOUNDATION <br />SQ <br />SQUARE <br />FE <br />FIRE EXTINGUISHER <br />SS <br />STAINLESS STEEL <br />FEC <br />FIRE EXTINGUISHER CABINET <br />STD <br />STANDARD <br />FF <br />FINISH FLOOR <br />STL <br />STEEL <br />FFE <br />FINISH FLOOR ELEVATION <br />STOR <br />STORAGE <br />FIN <br />FINISH <br />STRUCTSTRUCTURAL <br />FL <br />FLOOR <br />SUSP <br />SUSPENDED <br />FO <br />FACE OF <br />FOC <br />FACE OF CONCRETE <br />T <br />TEMPERED GLAZING <br />FOF <br />FACE OF FINISH <br />TC <br />TOP OF CURB <br />FOM <br />FACE OF MASONRY <br />TEL <br />TELEPHONE <br />FOS <br />FACE OF STUD <br />T&G <br />TONGUE AND GROOVE <br />FRT <br />FIRE RETARDANT TREATED <br />THK <br />THICK <br />FTG <br />FOOTING <br />TJ <br />TOOL JOINT <br />FURR <br />FURRING <br />TP <br />TOP OF PAVEMENT <br />TYP <br />TYPICAL <br />GA <br />GAUGE <br />TOD <br />TOP OF (MATERIAL) <br />GALV <br />GALVANIZED <br />TOP <br />TOP OF PARAPET <br />GB <br />GRAB BAR <br />TOS <br />TOP OF STRUCTURE <br />GC <br />GENERAL CONTRACTOR <br />GL <br />GLASS <br />UNFIN <br />UNFINISHED <br />GND <br />GROUND <br />LINO <br />UNLESS NOTED OTHERWISE <br />GVP <br />GYPSUM VENEER PLASTER <br />GWB <br />GYPSUM WALL BOARD <br />VB <br />VAPOR BARRIER <br />VERT <br />VERTICAL <br />HB <br />HOSE BIB <br />VEST <br />VESTIBULE <br />HC <br />HANDICAP <br />VFY <br />VERIFY <br />HDWR <br />HARDWARE <br />HM <br />HOLLOW METAL <br />W/ <br />WITH <br />HW <br />HOT WATER <br />WC <br />WATER CLOSET <br />HVAC <br />HEATING, VENTILATION AND <br />WD <br />WOOD <br />AIR CONDITIONING <br />WF <br />WIDE FLANGE <br />WG <br />WIRE GLASS <br />INSUL <br />INSULATION <br />WH <br />WATER HEATER <br />INT <br />INTERIOR <br />W/O <br />WITHOUT <br />WP <br />WATERPROOFING <br />JAN <br />JANITOR <br />WT <br />WEIGHT <br />JT <br />JOINT <br />JST <br />JOIST <br />Architect <br />D ky eman <br />1716 West Marine View Drive <br />Everett, WA 98201-2098 <br />Contact: Corey Wright <br />Phone: (425) 259 3161 <br />Email: coreyw@dykeman.net <br />Mechanical Engineer <br />HARGIS <br />1201 3rd Ave Suite #600 <br />Seattle, WA 98101 <br />Contact: Brian Boettcher <br />Phone: (206) 436 0404 <br />Email: brian.boettcher@hargis.biz <br />Electrical Engineer <br />HARGIS <br />1201 3rd Ave Suite #600 <br />Seattle, WA 98101 <br />Contact: Mark Humiston <br />Phone: (206) 859 5380 <br />Email: mark, humiston@hargis, biz <br />■ ■ ESUPERVISED AUTOMAC <br />SPRINKLER SYSTEM REQUIRED <br />chool -E3 13uilding <br />LOPED FOR - <br />9 1.".- 91 <br />strict #2 <br />PROPERTY INFORMATION CODE ANALISYS <br />NO FINAL <br />APPROVAL <br />DEC D p 2021 <br />ARCHIVED - <br />PARCEL NUMBER: JURISDICTION: City of Everett, Washington <br />00517155100100 <br />BUILDING CODE: International Existing Building Code (IEBC), <br />LEGAL DESCRIPTION: 2015 Edition & WAC 51-51. <br />MONITOR ADD BLK 551 D-00 BLK 551 TGW VAC ALLEY LY WITHIN SD LEVEL OF ALTERATION: Level 2 Alterations <br />BLK PER ORD640-79 TGW ALL OF BILKS 552 & 553 TGW PLAT OF <br />EVERETT BLK 551 LOT 1 & FRACLOTS 17 THRU 28 INCL & TGW ALL PLANNING CRITERIA <br />BLKS 552 & 553 ALSO TGW LOTS 13 THRU 20 BLK489 SD PLAT OF EV <br />DRAWING INDEX <br />GENERAL <br />G01 COVER SHEET <br />ARCHITECTURAL <br />SITE DEVELOPMENT <br />SD1.0 SITE PLAN <br />ET COF <br />DR INGS SHALL <br />E 0 OB SITE <br />Ai ALL ES• <br />THESE DOCUMENTS HAVE 140T BEEN <br />APPROVED FOR THE ISSUANCE OF <br />PU LIS WORKS, MECHANICAL, FIRE <br />SUPPRES,ION, ELECTRICAL OR <br />PLUIs DING PERMITS, <br />Additional Permits Are Required <br />For This Project To Include: <br />® Plumbing Sprinkler <br />f_ <br />ical Fire Alarm <br />Electrical <br />TGW ALL TH PTN VAC 24TH ST & TH PTN VAC ALLEY ABTG SD BLK Address: <br />2416 Colby Ave <br />ARCHITECTURAL <br />489 PER CITY OF EV ORD NO 1448-88 REC AF NO 8802190424 & <br />Everett, WA 98203 <br />A1.10 <br />B BUILDING - DEMOLITION PLAN <br />ALSO TGW VAC ALLEYS LT WHNBLKS 552 & 553 OF BOTH PLATS <br />Lot Area: 11.12 Acres <br />A121 <br />B BUILDING - FLOOR PLAN <br />PER CITY OFEV COUNCIL RECORDS DATED JUNE 5,1899 & PER ORD <br />Parcel: 00517155100100 <br />A6.10 <br />B BUILIDING - INTERIOR ELEVATIONS <br />NO 960 DATED OCT.21,1908 <br />Existing Building: <br />Name: Everett High School Cafeteria Building (B <br />ELECTRICAL <br />BUILDING ADDRESS: <br />Building) <br />2416 Colby Ave Everett, WA 98203 <br />Occupancy Type: Educational <br />Eo.01 <br />ELECTRICAL LEGEND AND DRAWING INDEX <br />Use: High School (Grades 9-12) <br />Eo.02 <br />ELECTRICAL ABBREVIATIONS AND GENERAL NOTES <br />BUILDING OWNER: <br />Construction Type: III-B <br />E0.03 <br />TELECOM AND LOW -VOLTAGE ROUGH -IN SCHEDULES <br />Everett Public Schools - 3900 Broadway - Everett, WA 98201 <br />Fire Sprinkler: Yes <br />ED2.01 <br />AUDITORIUM BASEMENT - LIGHTING DEMOLITION PLAN <br />Fire Alarm: Yes <br />ED3.01 <br />AUDITORIUM BASEMENT - POWER DEMOLITION PLAN <br />PROJECT DESCRIPTION: <br />Seismic Zone: Zone 3 <br />ED5.01 <br />AUDITORIUM BASEMENT- LOW VOLTAGE DEMOLITION <br />PLAN <br />• Interior demolition of non-structural walls, ceilings, light fixtures, <br />Recent Modifications: <br />ED6.01 <br />AUDITORIUM BASEMENT -TELECOM DEMOLITION PLAN <br />plumbing fixtures, and finishes. <br />2008 Seismic Upgrade <br />E2.01 <br />AUDITORIUM BASEMENT- LIGHTING PLAN <br />• Interior Construction of non-structural walls, ceilings, electrical <br />2012 Temporary Locker Rooms <br />E3.01 <br />AUDITORIUM BASEMENT- POWER PLAN <br />fixtures, plumbing fixtures, casework, and finishes. <br />E5.01 <br />AUDITORIUM BASEMENT- LOW VOLTAGE PLAN <br />VICINITY MAP <br />E6.01 <br />AUDITORIUM BASEMENT - TELECOM FLOOR PLAN <br />E8.01 <br />TELECOM AND LOW -VOLTAGE ENLARGED PLANS AND <br />ZONING REQUIREMENTS Everett Municipal Code 2018 <br />DETAILS <br />E8.02 <br />TELECOM AND LOW -VOLTAGE ENLARGED PLANS AND <br />DETAILS <br />Zone : R-3 (Multiple Family Medium Density) E8.03 <br />TELECOM AND LOW -VOLTAGE ENLARGED PLANS AND <br />DETAILS <br />E9.01 <br />ONE -LINE DIAGRAM <br />MECHANICAL <br />M0.01 B <br />MECHANICAL LEGEND & SHEET LIST <br />M0.0213 <br />MECHANICAL ABBREVIATIONS & GENERAL NOTES <br />MD2.01 B <br />BLDG B - MECHANICAL DEMOLITION PLAN <br />M3.01 B <br />BLDG B - MECHANICAL FLOOR PLAN <br />SITE KEY MAP <br />w <br />0 <br />- -I 1 L_ <br />LEl L <br />L T � - L LI 1 I <br />L <br />� z <br />24TH AVE <br />- <br />1161 <br />�^fi"}°'a <br />p ggm, <br />• max° <br />PROJECT SITE <br />ra <br />y <br />> <br />> <br />a <br />0"` <br />J <br />°v <br />w <br />25TH AVE <br />1 <br />CONSULTANT: <br />STAMP:REGISTRATION <br />9739 REGISTERED <br />ARCHITECT <br />qE,ILLI GARFR SMITH <br />TE OF HINGTON <br />PROJECT IDENTIFICATION: <br />Tenant Improvement <br />- Everett High School <br />B Building <br />FOR <br />Everett School <br />District #2 <br />-'-� IT AT <br />--244-& Colby Avenue <br />Everett, WA 98203 <br />PERMIT SET <br />04/01 /2019 <br />This drawing is: <br />1. Copyright 2019 Dykeman, Inc. <br />2. The Architect's Instrument of Professional Service. <br />3. For use on this project only. Obtain Architect's <br />written permission for any other use or reproduction. <br />2019-015 <br />0 <br />ILy <br />B <br />..O <br />PRINCIPAL IN CHARGE: KS <br />PROJECT MANAGER: CW <br />PROJECT ARCHITECT: CW <br />JOB CAPTAIN: <br />1 KG <br />Permit#: <br />B1904-003 <br />Site Address: <br />2415 COLBY <br />Owner: <br />EVERETT SCHOOL DIST 2 <br />Tenant: <br />BLDG B, AUDITORIUM-EVRT HIGH <br />APp•Date: <br />411/2019 <br />Prcpcsed Use: <br />COMMERCIAL <br />Description: <br />INTERIOR TENANT IMPROVEMENT-BLDG <br />B, <br />AUDITORIUM <br />1 <br />By: � - <br />reviewed <br />Date:__ <br />"- Office Set <br />Job Site Set Fire/Planning Set <br />COVER SHEET <br />DRAWING NUMBER: <br />A <br />1 <br />2 3 4 5 1 6 <br />1 <br />3/29/2019 11:43:28 AM <br />