3 1 4 <br />2=■ <br />0■ <br />0■ <br />PIPING SPECIALTIES <br />FIRE PROTECTION SYSTEM <br />REFRIGERANT PIPING SYSTEM <br />I UNION <br />F FIRE SPRINKLER <br />REFRIGERANT LIQUID LINE <br />i FLANGE <br />FM FIRE MAIN <br />RSL <br />REFRIGERANT SUCTION LINE <br />FLEX CONNECTOR <br />DRY SPRINKLER <br />-- <br />SIGHT GLASS WITH MOISTURE <br />INDICATOR <br />THERMAL/SEISMIC FLEXIBLE <br />LOOP <br />RECESSED SPRINKLER HEAD <br />FILTER DRYER <br />EJ THERMAL EXPANSION JOINT <br />SEMI -RECESSED SPRINKLER <br />HEAD <br />DUCTWORK <br />STRAINER <br />UPRIGHT SPRINKLER HEAD <br />BDD BDD <br />STRAINER WITH BLOW OFF <br />DOUBLE DETECTOR CHECK <br />BACKDRAFT DAMPER <br />VALVE04FW7104- <br />VALVE/DOUBLE CHECK VALVE <br />PIPE ANCHOR <br />ASSEMBLY <br />\ _ <br />VOLUME DAMPER <br />® ALIGNMENT GUIDE <br />® <br />FLEXIBLE CONNECTION TO <br />MECHANICAL EQUIPMENT <br />TIP <br />TEMPERATURE/PRESSURE <br />FIY IC PIPING SYSTEM <br />TRANSITION - FROM <br />TEST PORT <br />RECTANGULAR TO ROUND <br />THERMOMETER <br />C CONDENSATE DRAIN <br />TRANSITION - FROM ROUND TO <br />RECTANGULAR <br />RISE IN DUCT <br />PRESSURE GAGE <br />HEATING WATER SUPPLY <br />® ® ® HEATING WATER RETURN <br />PUMPS 16x3 <br />REVISION CALLOUT CWS CONDENSER WATER SUPPLY <br />16x3 <br />FLAG NOTE CALLOUT CENTRIFUGAL PUMP ® ® CONDENSER WATER RETURN <br />DEMOLITION NOTE TAG - 1NLINE PUMP CHS CHILLED WATER SUPPLY <br />EQUIPMENT TAG CIRCULATING PUMP CHR ®®® CHILLED WATER RETURN - <br />aHu-o7 MECHANICAL EQUIPMENT TAG BASE MOUNTED PUMP r4 AUTOMATIC AIR VENT/MANUAL <br />AIR VENT <br />AHU MECHANICAL EQUIPMENT TAG VALVECING/MEASURING \, <br />STORM DRAINAGE PIPING SYSTEM AUTOMATIC FLOW CONTROL <br />N NORTH ARROW VALVE <br />ROOF DRAIN <br />LOCATION WHERE PICTURE SPECIALTY PIPING SYSTEM <br />1 WAS TAKEN AND DIRECTION g OVERFLOW ROOF DRAIN <br />INVERT ELEVATION OR POC RL RAIN LEADER NPCW NON -POTABLE COLD WATER <br />ORL OVERFLOW RAIN LEADER NPHW NON -POTABLE HOT WATER <br />.ELECTRICAL PROVISIONS FOR MECHANICAL WORK NPM NON -POTABLE HOT WATER <br />CIRCULATION <br />LOCATION OF STARTER, SOIL AND WASTE WATER PIPINGSYSTEM <br />DISCONNECT & CONTROLS <br />vFD VARIABLE FREQUENCY DRIVE SANITARY SEWER/WASTE <br />UNDERGROUND <br />HT HT HEAT TRACE BETWEEN SANITARY SEWERMWASTE <br />SYMBOLS OR END OF RUN ABOVE GROUND <br />®®®®—®®® VENT PIPING <br />ACCESS, EXCAVATION, FILLI 4" VTR VENT THRU ROOF <br />(INCLUDE SIZE) <br />ACCESS DOOR (SPECIFIED OR AW ACID WASTE ABOVE GROUND <br />AS SHOWN ON DWGS) AW ACID WASTE UNDERGROUND <br />r MECHANICAL ACCESS <br />(SPECIFIED OR AS SHOWN ON AV ACID VENT <br />DWGS) <br />® FLOOR DRAIN/FUNNEL FLOOR <br />DRAIN <br />PIPING <br />FLOOR SINK <br />PIPE ELBOW UP OR PIPE TEE HUB DRAIN <br />UP AND DOWN <br />PIPE ELBOW DOWN TRENCH DRAIN <br />PIPE TEE UP CO CLEANOUT <br />PIPE TEE DOWN NOWCO CLEANOUT - FREE STANDING <br />WALL MOUNTED <br />PIPE RISE FCO CLEANOUT - FLUSH WITH <br />FLOOR <br />PIPE CAP <br />PIPE PLUG DOMESTIC AT I I SYSTEM <br />FLOW DIRECTION DOMESTIC COLD WATER <br />PIPE BREAK DOMESTIC HOT WATER <br />PIPE CONNECTION DOMESTIC HOT WATER <br />CIRCULATION <br />®® DOMESTIC HOT WATER (TEMP. <br />VALVES ®®®® DOMESTIC HOT WATER <br />VALVE: GATE, BALL, <br />BUTTERFLY (REFER TO WATER "DIETER <br />SPECIFICATIONS) <br />GLOBE VALVE BASKET STRAINER <br />SOLENOID VALVE HOSE BIBBNVALL HYDRANT <br />CHECK VALVE TRAP PRIMER BOX <br />BALANCING VALVE <br />PRESSURE REDUCING VALVE <br />REDUCED PRESSURE <br />BACKFLOW ASSEMBLY <br />SAFETY RELIEF VALVE <br />TEMPERATURE/PRESSURE <br />RELIEF VALVE <br />(D=DROP IN DUCT) <br />DUCT SIZE (CLEAR INSIDE <br />DIMENSION) <br />RECTANGULAR DUCT UP <br />RECTANGULAR DUCT DN <br />ROUND DUCT UP <br />ROUND DUCT DN <br />FLEXIBLE DUCTWORK <br />TRANSITION OR REDUCER <br />(FOT=FLAT ON TOP, FOB=FLAT <br />ON BOTTOM) <br />TRANSITION -ECCENTRIC <br />- FIRE DAMPER <br />F/S F/S <br />FIRE/SMOKE DAMPER <br />S S <br />SMOKE DAMPER <br />CEILING FIRE DAMPER <br />GRILLE REGISTER OR <br />TYPE <br />ODIFFUSER <br />A <br />RUNOUT SIZE (INCHES) <br />500 <br />AIR QUANTITY (CFM) <br />CEILING DIFFUSER <br />1-WAY DIRECTION FLOW <br />2-WAY DIRECTION FLOW <br />3-WAY DIRECTION FLOW <br />RETURN/RELIEF AIR GRILLE <br />EXHAUST AIR GRILLE <br />LINEAR DIFFUSER/GRILLE <br />--� <br />SUPPLY GRILLE <br />___VL <br />RETURN/EXHAUST GRILLE <br />— <br />TRANSFER GRILLE <br />RETURN/EXHAUST AIRFLOW <br />—� <br />SUPPLY AIR FLOW <br />R/D OR RIW=1.5 CONTROLS (PLAN VIEW) <br />T THERMOSTAT OR <br />Tu-XX TEMPERATURE SENSOR <br />R/D OR R/W=1.5 SENSOR: SHOWN WITH GUARD <br />G (TYPICAL ALL SENSORS) <br />SQUARE CORNER ELBOW HUMIDISTAT OR HUMIDITY <br />WITH H SENSOR <br />TURNING VANES <br />CO CARBON MONOXIDE SENSOR <br />®®®O ®®®9 ®® <br />c02 CARBON DIOXIDE SENSOR <br />IAQ INDOOR AIR QUALITY SENSOR PERMIT <br />® O OOB ® O ® 00 O ® O ® ® O ® 9 O <br />M <br />MOTORIZED DAMPER04/01/2019 <br />RADIUS TAP IN F <br />AIRFLOW MEASURING UNIT <br />DSD <br />DUCT SMOKE DETECTOR This drawing is: <br />WYE FITTING T 1. Copyright 2017 Dykeman, Inc. C <br />LP TEMPERATURE TRANSMITTER 2. The Architect's Instrument of Professional Service. <br />3. For use on this project only. Obtain Architect's <br />written permission for any other use or reproduction. <br />RADIUS TEE P <br />PRESSURE TRANSMITTER'g,." x' <br />SQUARE TEE WITH TURNING A <br />VANES o <br />AQUASTAT <br />029 <br />DP DIFFERENTIAL PRESSURE <br />BULLHEAD TEE SENSOR a Y <br />DIFFERENTIAL PRESSURE <br />MARK ®ATE DESCRIPTION <br />SECTION THRU RECTANGULAR MONITOR <br />SUPPLY AIR DUCT AUTOMATIC CONTROL VALVE, <br />SECTION THRU RECTANGULAR 3-WAY <br />RETURN OR OUTSIDE AIR AUTOMATIC CONTROL VALVE, <br />DUCT 2-WAY <br />SECTION THRU RECTANGULAR DIRECT DIGITAL CONTROL - <br />EXHAUST AIR DUCT DDC PANEL <br />SECTION THRU ROUND DUCT Y HOOD SWITCH BY MECHANICAL <br />RECTANGULAR SUPPLY DUCT <br />ROOF PENETRATION <br />RECTANGULAR RETURN OR <br />OUTSIDE AIR DUCT ROOF <br />PENETRATION <br />RECTANGULAR EXHAUST _ <br />DUCT ROOF PENETRATION <br />ROUND DUCT ROOF - B <br />PENETRATION ►,{� ..,Yr.\..: .._. \. <br />M0.01 B MECHANICAL LEGEND AND SHEET LIST <br />M0.02B MECHANICAL ABBREVIATIONS & GENERAL NOTES <br />MD2.01 B BUILDING B - MECHANICAL DEMOLITION PLAN <br />M3.01 B BUILDING B - MECHANICAL FLOOR PLAN <br />mechanical 1201 third avenue, suite 600 <br />electrical seat�tle, viashington 93101 <br />telec;ornmunications <br />security energy t 206.448.3376 vu hargis.hiz <br />I E I <br />■m <br />PRINCIPAL IN CHARGE: I BJB <br />PROJECT MANAGER: I BJB <br />PROJECT ARCHITECT: I e <br />JOB CAPTAIN: I SLR <br />MECHANICAL <br />D , <br />mil <br />I <br />N <br />5 <br />NOT ALL {, APPEAR ON THE DRAWINGS <br />