My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2415 COLBY AVE 2019 EVERETT HS CIVIC AUDITORIUM Plans 2022-11-23
>
Address Records
>
COLBY AVE
>
2415
>
EVERETT HS CIVIC AUDITORIUM
>
Plans
>
2415 COLBY AVE 2019 EVERETT HS CIVIC AUDITORIUM Plans 2022-11-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2022 1:57:38 PM
Creation date
12/14/2021 7:54:58 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2415
Tenant Name
EVERETT HS CIVIC AUDITORIUM
Permit
B1904-003
Year
2019
Notes
Interior tenant improvement - bldg b, auditorium
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />0 <br />0 <br />r <br />00 <br />e <br />4 5 6 <br />GENERAL NOTES - PLANS <br />A. DIMENSIONS TO EXISTING WALLS, OPENINGS, AND FIXTURES ARE TO BE FIELD VERIFIED. <br />B. INTERIOR DIMENSIONS ARE TO THE FACE OF CONCRETE, MASONRY, OR GWB AT FRAME WALLS, <br />AND TO CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED. <br />C. CONTRACTOR SHALL PROVIDE CONTINUOUS HORIZONTAL BLOCKING OR BOND BEAM AS <br />REQUIRED AT ALL WALL MOUNTED LAVATORIES, DRINKING FOUNTAINS, CASEWORK, MIRRORS, <br />HANDRAILS, ETC, REFER TO ARCHITECTURAL INTERIOR ELEVATIONS AND MECHANICAL DRAWINGS. <br />D. FLOOR TRANSITIONS SHALL OCCUR AT CENTERLINE OF DOOR TYPICAL UNLESS OTHERWISE <br />NOTED. <br />E. OMIT FLOORING BENEATH BASE CABINETS. <br />F. FLOOR FINISH TYPES - REFER TO MATERIAL LEGEND THIS SHEET. <br />G. UNLESS NOTED OTHERWISE, RECESSES AND PROJECTIONS RECEIVE SAME FINISH AS ADJACENT <br />SURFACES. <br />H. INSTALL NEW BASE AS REQUIRED FOR NEW CARPET, <br />I. ALL DIMENSIONS, ELEVATIONS, AND LOCATIONS OF EXISTING BUILDING COMPONENTS ARE BASED <br />ON INFORMATION GATHERED FROM CURSORY FIELD OBSERVATIONS AND ARE SHOWN FOR <br />REFERENCE ONLY. CONTRACTOR SHALL FIELD MEASURE AND VERIFY ALL CONDITIONS PRIOR TO <br />COMMENCING ANY WORK, NOTIFY THE ARCHITECT WHERE CONDITIONS VARY FROM THOSE <br />SHOWN. <br />Plan Leqend <br />EXISTING WALLS AND BUILDING ELEMENTS TO REMAIN <br />NEW WALLS AND BUILDING ELEMENTS <br />KEYNOTELEGEND <br />KEYNOTE KEIPNOTE TEXT <br />1. INSTALL SALVAGED CASEWORK FROM VOCATIONAL BUILDING. <br />2. INSTALL SALVAGED MARKER BOARDS AND TACK BOARDS FROM VOC <br />BUILDING. <br />MATERIAL LEGEND - FLOOR FINISHES <br />F1 -CARPET <br />L <br />EXISTING VCT FLOOR TILE <br />EXISTING CARPET <br />012- <br />23'-2" 22'-0° 22'-0° 23'-2° <br />—, <br />D <br />9739 <br />REGISTEP,ED <br />ARCHITECT <br />KELLI <br />GARDINER SMITH <br />STATE <br />OF WASHINGTON <br />This drawing Is: <br />1. Copyright 2018 Dykeman, Inc. C <br />2. The Architect's Instrument of Professional Service. <br />3. For use on this project only. Obtain Architect's <br />written permission for any other use or reproduction. <br />ARK DATE DESCRIPTION <br />B BUILDING -FLOOR <br />PLAN <br />F�`�s''�.Z�,"�� <br />EW7 <br />a <br />
The URL can be used to link to this page
Your browser does not support the video tag.