Laserfiche WebLink
w <br />Q <br />0 <br />co <br />M' <br />O <br />0 <br />co <br />M <br />LO <br />- <br />CV <br />CE <br />U <br />m <br />of <br />0 <br />o� <br />cV <br />co <br />0 <br />D <br />CONSTRUCTION PLAN <br />SCALE: 1/4" = 1'-0" 01. <br />SHEET NOTES <br />01 EXISTING STOREFRONT TO REMAIN <br />02 5/8" PLYWOOD TO BE PROVIDED TO EXTENT SHOWN <br />FROM FLOOR TO BOTTOM OF DECK WITH 5/8" GYP. ON <br />INTERIOR SIDE <br />03 PROVIDE FIRE RATED 3/4" PLYWOOD BACKER <br />BOARD ON ALL WALLS, H=8'-0". DO NOT PAINT <br />OVER FIRED RATED PLYWOOD STAMP. ALL <br />WALL POWER/DATA OUTLETS SHALL BE <br />RECESSED AND FLUSH WITH THE PLYWOOD <br />PANELS. <br />04 EXISTING STRUCTURAL COLUMN TO REMAIN; FURR <br />TIGHT WITH ONE LAYER GYPSUM BOARD; PAINT AS <br />SCHEDULED <br />GENERAL NOTES <br />A. ALL PARTITIONS TO BE TYPE "A36," UNLESS NOTED <br />OTHERWISE. REFER TO WALL PARTITION TYPES. <br />B. FOR ADDITIONAL GENERAL NOTES, LEGENDS AND <br />SCHEDULES, REFER TO SHEETS A00.00 AND A00.10. <br />C. UNLESS OTHERWISE NOTED, LOCATE HINGE SIDE <br />OF ALL DOORS 4" FROM ADJACENT PERPENDICULAR <br />PARTITION. <br />D. VERIFY ALL EQUIPMENT WITH VENDOR. <br />E. CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL <br />WALL -MOUNTED EQUIPMENT AND ACCESSORIES. <br />F. INSTALL TYPE X GYP. BOARD AT ALL EXISTING <br />PERIMETER WALLS. <br />WALL TYPE L <br />REFER TO SHEET A00.20 & A00.21 FOR ADDITIONAL <br />INFORMATION <br />1 A PARTITION TAG <br />PARTITION TYPE DESIGNATOR <br />(SEE PARTITION SERIES TYPE SCHEDULES) <br />FRAMING MEMBER SIZE <br />(SEE TABLE B BELOW) <br />PARTITION SERIES <br />(SEE TABLE A - BELOW) <br />FIRE RATING (IF APPLICABLE) <br />QUICK REFERENCE PARTITION TYPE DESIGNATOR <br />X XXA GYP BD UP SLAB TO SLAB (FULL HEIGHT) <br />X XXB GYP BD UP 6" PAST CEILING <br />X XXC GYP BD UP PARTIAL HEIGHT (PER PLAN) <br />X XXD GYP BD UP 12" PAST CEILING <br />X XXE GYP BD UP TO CEILING HEIGHT <br />4 µ NOT IN CONTRACT <br />EXISTING PARTITION TO <br />REMAIN <br />NEW PARTITION <br />XXX REFERENCE TO PARTITION <br />TYPE <br />17777777771 FIRE RATED PARTITION <br />NEW DOOR <br />EXISTING DOOR TO REMAIN <br />r� <br />1 <br />A COLUMN GRID <br />OFFICE ROOM NAME <br />### ROOM NUMBER <br />ff 1 DOOR NUMBER <br />01 SHEET NOTES <br />oz�\ REVISION REFERENCE <br />DIRECTION OF ELEVATION <br />xx <br />Axx.xx ELEVATION NUMBER ON <br />SHEET <br />SHEET WHERE SHOWN <br />xx DETAIL NUMBER <br />Axx.xx SHEET WHERE SHOWN <br />Sim <br />II DESCRIPTION OF SIMILAR <br />t OR OPPOSITE <br />AREA TO BE DETAILED <br />MILLWORK <br />EOR--- MILLWORK SCHEDULE TAG <br />MW## <br />ALIGN <br />i ALIGN <br />FEC <br />FIRE EXTINGUISHER <br />CABINET (F.E.C.) <br />KEVLAR PANELS TO BE <br />INSTALLED PER WALL TYPE <br />BANK OF AMERICA <br />GREENTREE PLAZA <br />EVERETT, WA 98208 <br />SERIAL 1 A4i <br />VERSION:NRSP 1 <br />141 ! <br />1200 Sixth Avenue Tel 206.654.2100 <br />Suite 500 Fax 206.654.2121 <br />Seattle, WA 98101 <br />United States <br />JLL Third Party Project Management <br />800 5th Avenue <br />Seattle, WA 98104 <br />Contact: Jim Foster <br />jim.foster@am.jll.com <br />Tel 206.375.4788 <br />0 Date Description <br />03/19/2021 ISSUE FOR PERMIT <br />Seal / Signature <br />5461 E"185 <br />LMTIS CHU <br />STA= OF WSMMON <br />Project Name <br />GREENTREE PLAZA <br />Project Number <br />032.4596.003 <br />Description <br />CONSTRUCTION PLAN <br />Scale <br />As indicated <br />F -y <br />mil TV ail <br />M <br />© 2021 Gensler <br />