Laserfiche WebLink
CONT <br />CONTINUOUS(ATION) <br />JAN <br />JANITOR <br />SUSP <br />SUSPENDED <br />CONTR <br />CONTRACT(OR) <br />K <br />SYS <br />SYSTEM(S) <br />COV <br />COVER <br />KIT <br />KITCHEN <br />T <br />CPT <br />CARPET <br />L <br />T&G <br />TONGUE AND GROOVE <br />D <br />LAV <br />LAVATORY <br />TG <br />TEMPERED GLASS <br />DBL <br />DOUBLE <br />LB <br />POUND <br />THK <br />THICK <br />DEPT <br />DEPARTMENT <br />LOUVER <br />LOUVER <br />TLT <br />TOILET <br />DES <br />DESIGNED) <br />LT <br />LIGHT <br />TRAP <br />TRAFFIC <br />DET <br />DETAIL <br />LVLG <br />LEVELING <br />TRANS <br />TRANSPARENT <br />DF <br />DRINKING FOUNTAIN <br />M <br />TRTD <br />TREATED <br />DIA <br />DIAMETER <br />M.E. <br />MATCH EXISTING <br />TYP <br />TYPICAL <br />DIFF <br />DIFFUSER <br />MAX <br />MAXIMUM <br />U <br />DIM <br />DIMENSION <br />MECH <br />MECHANICAL <br />UNDRLAY <br />UNDERLAYMENT <br />DISP <br />DISPENSER <br />MEMB <br />MEMBRANE <br />LION <br />UNLESS OTHERWISE <br />DIV <br />DIVISION <br />MET <br />METAL <br />NOTED <br />DN <br />DOWN <br />MEEE <br />MEZZANINE <br />UTIL <br />UTILITY <br />DR <br />DOOR <br />MFD <br />MANUFACTURED <br />DSCON <br />DISCONNECT <br />MFR <br />MANUFACTURER <br />VEH <br />VEHICLE <br />DWR <br />DRAWER <br />MIN <br />MINIMUM <br />VERT <br />VERTICLE <br />E <br />MISC <br />MISCELLANEOUS <br />VIIF <br />VERIFY IN FIELD <br />ELAST <br />ELASTOMERIIC <br />MLWK <br />MILLWORK <br />W <br />ELEC <br />ELECTRICAL <br />MOIST <br />MOISTURE <br />wl <br />WITH <br />EMBED <br />EMBEDD(ED)(ING) <br />MOT <br />MOTOR(IEED) <br />W/O <br />WITHOUT <br />ENGR <br />ENGINEERED) <br />MTD <br />MOUNTED <br />WC <br />WATER CLOSET <br />ENTR <br />ENTRANCE <br />N <br />WD <br />WOOD <br />EQ <br />EQUAL <br />NIC <br />NOT IN CONTRACT <br />WDW <br />WINDOW <br />EQUIP <br />EQUIPMENT <br />NO <br />NUMBER <br />WI <br />WEIGHT <br />EX <br />EXISTING <br />NTS <br />NOT TO SCALE <br />WTRPRF <br />WATERPROOFING <br />EXP JT <br />EXPANSION JOINT <br />O <br />EXPS <br />EXPOSE(D) <br />OH <br />OPPOSITE HAND <br />EXT <br />EXTERIOR <br />OPNG <br />OPENING(S) <br />F <br />OPP <br />OPPOSITE <br />FAB <br />FABRICATION <br />OPR <br />OPERABLE <br />FD <br />FLOOR DRAIN <br />ORNA <br />ORNAMENTAL <br />FE <br />FIRE EXTINGUISHER <br />OS <br />OCCUPANCYSENSOR <br />FE&C <br />FIRE EXTINGUISHER AND <br />OVFL <br />OVERFLOW <br />CABINET <br />OVHD <br />OVERHEAD <br />FHC <br />FIRE HOSE CABINET <br />P <br />FIN <br />FINISH <br />PBD <br />PARTICLE BOARD <br />FLDG <br />FOLDING <br />PEDTR <br />PEDESTRIAN <br />FLR <br />FLOORING) <br />PLAM <br />PLASTIC LAMINATE <br />FPLC <br />FIREPLACE <br />PLAS <br />PLASTER <br />FIR <br />FIRE RAT(ING)(ED) <br />PLSTC <br />PLASTIC <br />FRMG <br />FRAMING <br />PLYWD <br />PLYWOOD <br />FURN <br />FURNITURE <br />PNL <br />PANEL <br />FWC <br />FABRIC WALL COVERING <br />POLYST <br />POLYSTYRENE <br />FXD <br />FIXED <br />PORT <br />PORTABLE <br />C. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY <br />THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 <br />POUNDS. <br />FA " ) ! P ) <br />LOCKING DEVICE IS READILY DISTINGUISHABLE AS i� VISIBLE <br />t <br />POSTED <br />ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN <br />BUILDING ", <br />CONTRASTING <br />TYPICAL MOUNTING HEIGHTS <br />yr <br />---------------------- <br />OUTLINE OF <br />DOOR IN OPEN <br />' <br />POSITION <br />6a <br />i <br />ALIGN TOP OF <br />' <br />DEVICES <br />O <br />E- <br />I <br />2° <br />� <br />` <br />THERMOSTAT <br />\0 <br />®` <br />GANG OF DIMMER <br />q- <br />SWITCHES <br />LO <br />Ln' <br />i <br />FLUORESCENT <br />` <br />SWITCH (SECURITY <br />\\` <br />DEVICE WHERE <br />OCCURS. I.E. CARD <br />co <br />` <br />READERS, ETC. ) <br />DEVICES AT DOOR IN OPEN POSITION <br />DOORFRAME <br />' <br />AUDIBLE/VISIBLE STROBE <br />' <br />FIRE EXTINGUISHER <br />AND/OR HOSE CABINET <br />' <br />PEEP SCOPE, WHERE <br />'61, <br />SCHEDULED <br />1_41 <br />HOLD UP LIGHT <br />/ <br />PEEP SCOPE WHERE <br />SCHEDULED AND <br />REQUIRED BY CODE <br />f, <br />2 <br />L4JI <br />`� <br />c� <br />co` <br />4 1/2" <br />THERMOSTAT LOCATION. <br />DO NOT LOCATE <br />®. <br />DIRECTLY ABOVE <br />DIMMERS. <br />LOCATION FOR: LIGHT <br />< <br />CIO <br />SWITCH, DIMMERS, <br />` <br />00 <br />EGRESS BUTTON, CARD <br />co <br />READER, (ETC.) CLUSTER. <br />SEE PLAN FOR QUANTITY <br />OF EACH CLUSTER. USE <br />GANG -TYPE COVER <br />PLATES FOR MORE THAN <br />` <br />ONE DEVICE OF THE SAME <br />` <br />TYPE. <br />DEVICES AT DOOR IN CLOSED POSITION <br />NOTE: ALL DIMENSIONS TO CENTER LINE OF DEVICES U.N.O.- INTERCOM <br />TO BE MOUNTED AT <br />3' 9" AFF U.N.O.: CENTER ALL DEVICES BELOW SWITCH. ALL OPERABLE PARTS <br />SHALL BE <br />OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, <br />PINCHING, OR <br />TWISTING OF THE WRIST WITH A MAX OF 5 LB& OF FORCE TO OPERATE. <br />A CLEAR SPACE TO <br />BE PROVIDED OF 30" MIN. X 48" MIN. <br />ACCESSIBILITY <br />I <br />- CHANGES IN THE CEILING PLANE MUST HAVE POSITIVE BRACING. I I <br />- CABLE TRAYS AND ELECTRICAL CONDUITS MUST BE INDEPENDENTLY SUPPORTED AND <br />BRACED. <br />- IF PARTITIONS ARE ATTACHED TO THE SUSPENDED SYSTEM, THEY MUST BE LATERALLY <br />BRACED TO THE BUILDING <br />• <br />- PENDANT MOUNTED FXTURES MUST BE SUPPORTED FROM THE STRUCTURE. THEY MAY <br />NOT SUE THE CEILING SUSPENSION SYSTEM FOR SUPPORT. <br />- LIGHT FIXTURES MUST BE POSITIVELY ATTACHED TO THE SUSPENSION SYSTEM. <br />ATTACHED DEVICE MUST BE ABLE TO WITHSTAND 100% OF THE FIXTURE WEIGHT. <br />- IF LIGHT FIXTURE IS 56 POUNDS OR LESS, MUST HAVE TWO 12-GUAGE WIRES ATTACHED <br />AT DIAGONAL CORNERS. IF MORE THAN 56 POUNDS, MUST BE INDEPENDENTLY SUPPORTED <br />FROM THE BUILDING STRUCTURE. <br />2. SEE SHEET SERIES A13 FOR CEILING SYSTEM DETAILS. <br />3. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPRINKLER <br />HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL <br />UNITS, UNLESS OTHERWISE NOTED. <br />4. FINISH HVAC DIFFUSERS, DRAPERY POCKETS, AND SPEAKER GRILLES TO MATCH <br />ADJACENT FINISH, UNLESS OTHERWISE NOTED. <br />GENERAL NOTES <br />mm ma <br />1. ALL WORK SHALL CONFORM TO THE AMERICAN WITH DISABILITIES ACT (A.D.A.), WHERE <br />APPLICABLE, ALONG WITH ALL STATE, COUNTY, AND LOCAL APPLICABLE CODES, <br />ORDERS, ORDINANCES AND REGULATIONS. PRIOR TO START OF WORK, NOTIFY <br />ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS AND CODE. ALL WORK <br />SHALL CONFORM TO THE MOST RESTRICTIVE REQUIREMENTS. <br />2. BEFORE COMMENCING WORK, CONTRACTOR SHALL BECOME FAMILIAR WITH THE <br />DRAWINGS AND THE SCOPE OF WORK. CONTRACTOR SHALL VERIFY EXISTING <br />CONDITIONS AND DIMENSIONS AT THE SITE. ARCHITECT SHALL BE NOTIFIED OF <br />DISCREPANCIES. <br />3. BEFORE COMMENCING WORK, THE GENERAL CONTRACTOR SHALL SUBMIT AN ITEMIZED <br />COST BREAK DOWN OF ALL SCOPE ITEMS AND A CONSTRUCTION SCHEDULE TO THE <br />BANK OF AMERICA PROJECT MANAGER AND THE ARCHITECT. WORK SHALL_ BE <br />SCHEDULED TO MEET BAND OF AMERICA REQUIREMENTS. <br />4. ALL WORK DESCRIBED OR INDICATED IN THESE DOCUMENTS AND ALL WORK <br />DEPENDENT UPON OR NECESSARY TO COMPLETE THIS WORK SHALL BE EXECUTED IN A <br />WORKMAN -LIKE MANNER CONSISTENT WITH THE BEST STANDARDS OF THE TRADE. <br />ITEMS AND MATERIALS USED SHALL BE SUITED FOR THE INTENDED PURPOSE. <br />5. TRADESMEN, CRAFTSMEN, INSTALLERS, FOREMEN AND SUPERVISORS ARE TO BE <br />SKILLED, EXPERIENCED AND LICENSED IF REQUIRED IN THE WORK THEY WILL BE <br />PERFORMING, <br />6. PROJECT CONSTRUCTION ITEMS TO BE NE1it/', UNLESS NOTED OTHERWISE. NO <br />SUBSTITUTIONS WILL BE ALLOWED UNLESS COMPLETE DESCRIPTIONS, DRAWINGS, <br />TEST DATA, SAMPLES, COST AND SCHEDULED CHANGES ARE SUBMITTED BY THE <br />CONTRACTOR AND APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. ANY ITEMS <br />NOTED ON THE DRAWINGS THAT ARE NOT AVAILABLE OR WOULD CAUSE A TIME DELAY <br />SHALL BE IDENTIFIED BY THE GENERAL CONTRACTOR AND THE ARCHITECT SHALL. BE <br />NOTIFIED. <br />7. TYPICAL DETAILS AND GENERAL NOTES SHALL BE USED WHENEVER APPLIABLE U.N.O. <br />ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED <br />CONSTRUCTION STANDARDS. IF CONTRACTOR HAS ANY QUESTIONS REGARDING THE <br />SAME OR EXACT MEANING, ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION. <br />S. DIMENSIONS ARE TO THE FACE OF FINISH ON EXISTING OR NEW WORK, UNLESS NOTED <br />OTHERWISE. DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. LARGER SCALE <br />DRAWINGS SHALL HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS. <br />9. PROVIDE SHOP DRAWINGS WHERE INDICATED AND FOR ALL METAL FABRICATION OR <br />WHERE NOTED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL <br />SUBMIT FIVE (5) SETS TO THE ARCHITECT WITH AMPLE TIME TO REVIEW. REQUIRED <br />CORRECTIONS WILL BE NOTED AND A COPY WILL BE RETURNED TO THE CONTRACTOR. <br />THE CONTRACTOR SHALL REVISE THE DRAWINGS AND RESUBMIT FOR FINAL APPROVAL <br />PRIOR TO FABRICATION. <br />10. CONTRACTOR TO SUBMIT SAMPLES OF ALL FINISH MATERIALS TO THE ARCHITECT FOR <br />APPROVAL PRIOR TO INSTALLATION. <br />11. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS -BUILT DRAWINGS NOTING <br />DEVIATIONS BETWEENTHE DRAWINGS, THE ACTUAL FIELD CONDITIONS AND THE NEW <br />CONSTRUCTION OF ALL TRADES. AS -BUILT DRAWINGS SHALL BE DELIVERED TO BANK <br />OF AMERICA AT THE END OF THE PROJECT. GENERAL CONTRACTOR SHALL PROVIDE <br />ALL SUBCONTRACTORS WITH THE MOST CURRENT CONSTRUCTION DOCUMENTS <br />THROUGHOUT THE PROJECT INCLUDING ALL REVISIONS. <br />12. CONTRACTOR TO NOTIFY ARCHITECT AND BANK OF AMERICA PROJECT MANAGER OF <br />ALL REVISIONS TO THE DRAWINGS AND CHANGES TO THE SCOPE OF WORK OR <br />SCHEDULE AS REQUIRED BY GOVERNING AGENCIES, FIELD CONDITIONS OR BANK OF <br />AMERICA PERSONNEL REGARDLESS OF EXTENT. ALL REVISIONS TO BE IN WRITING AS <br />CHANGE ORDERS AND APPROVED PRIOR TO STARTING WORK. <br />13. CONTRACTOR TO PROVIDE PROTECTIVE EQUIPMENT TO ENSURE THE LIFE SAFETY OF <br />PUBLIC, TENANTS AND WORKERS AS REQUIRED BY FEDERAL, STATE .AND LOCAL CODES <br />THROUG}-LOUT CONSTRUCTION. CONTR�iCTOR SHALL TAKE ALL 3�ECESSARY <br />MEASURES TO PROTECT PEDESTRIANS. <br />14. CONTRACTOR TO VERIFY EXISTING STRUCTURAL CONDITIONS AND REQUIREMENTS OF <br />NEW CONSTRUCTION PRIOR TO START OF WORK, CONTRACTOR SHALL FURNISH <br />ADEQUATE SHORING, BRACING, ETC. AS REQUIRED TO SAFETLY EXECUTE ALL WORK <br />AND SHALL BE RESPONSIBLE FOR THE SAME, UNLESS SPECIFICALLY DETAILED IN THE <br />DRAWINGS. CONTRACTOR SHALL PROVIDE BLOCKING, BACKING, FRAMING, HANGERS, <br />OR OTHER SUPPORTS AS NECESSARY FOR ALL FIXTURES, EQUIPMENT AND ALL OTHER <br />ITEMS AS NECESSARY. <br />15. SITE AND BUILDING SHALL BE MAINTAINED IN A CLEAN, SAFE MANNER. DIRTY OR NOISY <br />WORK SHALL BE PERFORMED AT SUCH A TIME AS DIRECTED BY THE OWNER AND/ OR <br />CITY. ALL TRASH DEBRIS, SURPLUS MATERIAL, TOOLS AND EQUIPMENT TO BE <br />REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL MANNER. LEAVE PREMISES IN <br />A CONDITION ACCEPTABLE TO BANK OF AMERICA OR OWNER. <br />16. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. WHERE EXISTING <br />CONSTRUCTION, FINISHES OR EQUIPMENT IS DAMAGED BY WORK IN THIS CONTRACT, IT <br />SHALL BE PATCHED, REPAIRED OR REPLACED AS REQUIRED TO MATCH EXISTING AT NO <br />COST TO BANK OF AMERICA. <br />17. THE LOCATION AND ELEVATIONS OF ALL WORK TO BE CONSTRUCTED IS SHOWN ON <br />THE DRAWINGS. UNLESS DISCREPANCIES ARE BROUGHT TO THE ATTENTION OF THE <br />ARCHITECT PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE HELD <br />RESPONSIBLE FOR THE PROPER LOCATION AND ELEVATIONS AS SHOWN AND <br />INTENDED. <br />18. THE CONTRACTOR SHALL LAY -OUT THE WORK, ESTABLISH AND MAINTAIN NECESSARY <br />MARKERS AND BE RESPONSIBLE FOR THE ACCURACY OF THE WORK. THE <br />CONTRACTOR SHALL MARK, AS A GUIDE TO ALL TRADES AND TO HIS <br />SUBCONTRACTORS, THE EXACT LOCATIONS OF NEW OR REMODELED WORK WITH <br />RESPECT TO ALL CHANGES TO EXISTING. <br />19. INSTALL AND APPLY ITEMS, MATERIALS, EQUIPMENT, FINISHES, ETC. INCLUDING THE <br />PREPARATION OF SURFACES IN STRICT ACCORDANCE WITH THE MANUFACTURER'S <br />PRINTED RECOMMENDATIONS AND INSTALLATION REQUIREMENTS. <br />20. PERTAINING TO EQUIPMENT: GENERAL CONTRACTOR IS RESPONSIBLE FOR THE <br />REMOVAL AND RELOCATION OF ANY EXISTING EQUIPMENT OR CONSTRUCTION AS <br />NECESSARY FOR A COMPLETE INSTALLATION. <br />21. ACCESS PANELS SHALL BE PROVIDED FOR ALL EQUIPMENT SWITCHES, VALVES AND <br />OTHER CONTROL DEVICES THAT ARE CONCEALED. EXACT LOCATIONS TO BE <br />APPROVED BY ARCHITECT PRIOR TO INSTALLATION. <br />22. BESIDES GUARANTEES REQUIRED ELSEWHERE, THE CONTRACTOR SHALL GUARANTEE <br />ALL WORK FOR A MINIMUM PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE OF <br />WORK WITHOUT EXPENSE TO BANK OF AMERICA. GUARANTEE SHALL INCLUDE ANY <br />WORK THAT MAY BE DISPLACED BY GENERAL CONTRACTOR'S WORK. <br />23. OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES <br />GOVERNING THE WORK. <br />24. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT FOR <br />REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION. <br />25. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR'WC" UNDER SEPARATE <br />CONTRACT. CONTRACTOR SHALL INCLUDE SCHEDULE REQUIREMENTS IN <br />CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY <br />SEQUENCE OF INSTALLATION. <br />26. CONTRACTOR TO COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM <br />INSTALLATIONS. <br />27. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. <br />28. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, <br />CONSULT THE ARCHITECT. <br />29. COORDINATE AND PROVIDE BLOCKING FOR MILLWORK AND ITEMS ATTACHED OR <br />MOUNTED TO WALLS OR CEILINGS. <br />30. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS NOTED <br />OTHERWISE. <br />31. CONCEALED INSULATING MATERIALS INSTALLED WITHIN WALL SHALL HAVE A FLAME <br />SPREAD INDEX OF NOT MORE THAN 75 AND A SMOKE DEVELOPED INDEX OF NOT MORE <br />THAN 450. <br />32. INSULATING MATERIALS WHICH ARE SUBJECT TO DIRECT EXPOSURE TO POTENTIAL <br />FIRE ON THE INSIDE OF THE BUILDING DUE TO INSTALLATION IN UNCONCEALED SPACES <br />SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED <br />INDEX OF NOT MORE THAN 450. <br />33. MATERIALS EXPOSED WITHIN PLENUMS ARE REQUIRED TO BE NONCOMBUSTIBLE OR <br />SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED <br />INDEX OF NOT MORE THAN 50 AS DETERMINED IN ACCORDANCE WITH ASTM E 84. <br />A N :I FA M EI'll C <br />��- <br />F <br />1200 Sixth Avenue Tel 206.654.2100 <br />Suite 500 Fax 206.654.2121 <br />Seattle, IIUA 98101 <br />United States <br />l <br />JLvx $'I P <br />JLL Third Party Project Management <br />800 5th Avenue <br />Seattle, VVA 98104 <br />Contact: Jim Foster <br />jim.fosterc@am.jll.com <br />Tel 206.375,4788 <br />z�, Date Description <br />03/19/2021 ISSUE FOR PERMIT <br />Project Name <br />GREENTREE PLAZA <br />Description <br />GENERA, NOTES AND TYPICAL <br />MOUNTM HEIGHTS <br />Seale <br />© 2021 Gensler <br />