CONT
<br />CONTINUOUS(ATION)
<br />JAN
<br />JANITOR
<br />SUSP
<br />SUSPENDED
<br />CONTR
<br />CONTRACT(OR)
<br />K
<br />SYS
<br />SYSTEM(S)
<br />COV
<br />COVER
<br />KIT
<br />KITCHEN
<br />T
<br />CPT
<br />CARPET
<br />L
<br />T&G
<br />TONGUE AND GROOVE
<br />D
<br />LAV
<br />LAVATORY
<br />TG
<br />TEMPERED GLASS
<br />DBL
<br />DOUBLE
<br />LB
<br />POUND
<br />THK
<br />THICK
<br />DEPT
<br />DEPARTMENT
<br />LOUVER
<br />LOUVER
<br />TLT
<br />TOILET
<br />DES
<br />DESIGNED)
<br />LT
<br />LIGHT
<br />TRAP
<br />TRAFFIC
<br />DET
<br />DETAIL
<br />LVLG
<br />LEVELING
<br />TRANS
<br />TRANSPARENT
<br />DF
<br />DRINKING FOUNTAIN
<br />M
<br />TRTD
<br />TREATED
<br />DIA
<br />DIAMETER
<br />M.E.
<br />MATCH EXISTING
<br />TYP
<br />TYPICAL
<br />DIFF
<br />DIFFUSER
<br />MAX
<br />MAXIMUM
<br />U
<br />DIM
<br />DIMENSION
<br />MECH
<br />MECHANICAL
<br />UNDRLAY
<br />UNDERLAYMENT
<br />DISP
<br />DISPENSER
<br />MEMB
<br />MEMBRANE
<br />LION
<br />UNLESS OTHERWISE
<br />DIV
<br />DIVISION
<br />MET
<br />METAL
<br />NOTED
<br />DN
<br />DOWN
<br />MEEE
<br />MEZZANINE
<br />UTIL
<br />UTILITY
<br />DR
<br />DOOR
<br />MFD
<br />MANUFACTURED
<br />DSCON
<br />DISCONNECT
<br />MFR
<br />MANUFACTURER
<br />VEH
<br />VEHICLE
<br />DWR
<br />DRAWER
<br />MIN
<br />MINIMUM
<br />VERT
<br />VERTICLE
<br />E
<br />MISC
<br />MISCELLANEOUS
<br />VIIF
<br />VERIFY IN FIELD
<br />ELAST
<br />ELASTOMERIIC
<br />MLWK
<br />MILLWORK
<br />W
<br />ELEC
<br />ELECTRICAL
<br />MOIST
<br />MOISTURE
<br />wl
<br />WITH
<br />EMBED
<br />EMBEDD(ED)(ING)
<br />MOT
<br />MOTOR(IEED)
<br />W/O
<br />WITHOUT
<br />ENGR
<br />ENGINEERED)
<br />MTD
<br />MOUNTED
<br />WC
<br />WATER CLOSET
<br />ENTR
<br />ENTRANCE
<br />N
<br />WD
<br />WOOD
<br />EQ
<br />EQUAL
<br />NIC
<br />NOT IN CONTRACT
<br />WDW
<br />WINDOW
<br />EQUIP
<br />EQUIPMENT
<br />NO
<br />NUMBER
<br />WI
<br />WEIGHT
<br />EX
<br />EXISTING
<br />NTS
<br />NOT TO SCALE
<br />WTRPRF
<br />WATERPROOFING
<br />EXP JT
<br />EXPANSION JOINT
<br />O
<br />EXPS
<br />EXPOSE(D)
<br />OH
<br />OPPOSITE HAND
<br />EXT
<br />EXTERIOR
<br />OPNG
<br />OPENING(S)
<br />F
<br />OPP
<br />OPPOSITE
<br />FAB
<br />FABRICATION
<br />OPR
<br />OPERABLE
<br />FD
<br />FLOOR DRAIN
<br />ORNA
<br />ORNAMENTAL
<br />FE
<br />FIRE EXTINGUISHER
<br />OS
<br />OCCUPANCYSENSOR
<br />FE&C
<br />FIRE EXTINGUISHER AND
<br />OVFL
<br />OVERFLOW
<br />CABINET
<br />OVHD
<br />OVERHEAD
<br />FHC
<br />FIRE HOSE CABINET
<br />P
<br />FIN
<br />FINISH
<br />PBD
<br />PARTICLE BOARD
<br />FLDG
<br />FOLDING
<br />PEDTR
<br />PEDESTRIAN
<br />FLR
<br />FLOORING)
<br />PLAM
<br />PLASTIC LAMINATE
<br />FPLC
<br />FIREPLACE
<br />PLAS
<br />PLASTER
<br />FIR
<br />FIRE RAT(ING)(ED)
<br />PLSTC
<br />PLASTIC
<br />FRMG
<br />FRAMING
<br />PLYWD
<br />PLYWOOD
<br />FURN
<br />FURNITURE
<br />PNL
<br />PANEL
<br />FWC
<br />FABRIC WALL COVERING
<br />POLYST
<br />POLYSTYRENE
<br />FXD
<br />FIXED
<br />PORT
<br />PORTABLE
<br />C. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY
<br />THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15
<br />POUNDS.
<br />FA " ) ! P )
<br />LOCKING DEVICE IS READILY DISTINGUISHABLE AS i� VISIBLE
<br />t
<br />POSTED
<br />ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN
<br />BUILDING ",
<br />CONTRASTING
<br />TYPICAL MOUNTING HEIGHTS
<br />yr
<br />----------------------
<br />OUTLINE OF
<br />DOOR IN OPEN
<br />'
<br />POSITION
<br />6a
<br />i
<br />ALIGN TOP OF
<br />'
<br />DEVICES
<br />O
<br />E-
<br />I
<br />2°
<br />�
<br />`
<br />THERMOSTAT
<br />\0
<br />®`
<br />GANG OF DIMMER
<br />q-
<br />SWITCHES
<br />LO
<br />Ln'
<br />i
<br />FLUORESCENT
<br />`
<br />SWITCH (SECURITY
<br />\\`
<br />DEVICE WHERE
<br />OCCURS. I.E. CARD
<br />co
<br />`
<br />READERS, ETC. )
<br />DEVICES AT DOOR IN OPEN POSITION
<br />DOORFRAME
<br />'
<br />AUDIBLE/VISIBLE STROBE
<br />'
<br />FIRE EXTINGUISHER
<br />AND/OR HOSE CABINET
<br />'
<br />PEEP SCOPE, WHERE
<br />'61,
<br />SCHEDULED
<br />1_41
<br />HOLD UP LIGHT
<br />/
<br />PEEP SCOPE WHERE
<br />SCHEDULED AND
<br />REQUIRED BY CODE
<br />f,
<br />2
<br />L4JI
<br />`�
<br />c�
<br />co`
<br />4 1/2"
<br />THERMOSTAT LOCATION.
<br />DO NOT LOCATE
<br />®.
<br />DIRECTLY ABOVE
<br />DIMMERS.
<br />LOCATION FOR: LIGHT
<br /><
<br />CIO
<br />SWITCH, DIMMERS,
<br />`
<br />00
<br />EGRESS BUTTON, CARD
<br />co
<br />READER, (ETC.) CLUSTER.
<br />SEE PLAN FOR QUANTITY
<br />OF EACH CLUSTER. USE
<br />GANG -TYPE COVER
<br />PLATES FOR MORE THAN
<br />`
<br />ONE DEVICE OF THE SAME
<br />`
<br />TYPE.
<br />DEVICES AT DOOR IN CLOSED POSITION
<br />NOTE: ALL DIMENSIONS TO CENTER LINE OF DEVICES U.N.O.- INTERCOM
<br />TO BE MOUNTED AT
<br />3' 9" AFF U.N.O.: CENTER ALL DEVICES BELOW SWITCH. ALL OPERABLE PARTS
<br />SHALL BE
<br />OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,
<br />PINCHING, OR
<br />TWISTING OF THE WRIST WITH A MAX OF 5 LB& OF FORCE TO OPERATE.
<br />A CLEAR SPACE TO
<br />BE PROVIDED OF 30" MIN. X 48" MIN.
<br />ACCESSIBILITY
<br />I
<br />- CHANGES IN THE CEILING PLANE MUST HAVE POSITIVE BRACING. I I
<br />- CABLE TRAYS AND ELECTRICAL CONDUITS MUST BE INDEPENDENTLY SUPPORTED AND
<br />BRACED.
<br />- IF PARTITIONS ARE ATTACHED TO THE SUSPENDED SYSTEM, THEY MUST BE LATERALLY
<br />BRACED TO THE BUILDING
<br />•
<br />- PENDANT MOUNTED FXTURES MUST BE SUPPORTED FROM THE STRUCTURE. THEY MAY
<br />NOT SUE THE CEILING SUSPENSION SYSTEM FOR SUPPORT.
<br />- LIGHT FIXTURES MUST BE POSITIVELY ATTACHED TO THE SUSPENSION SYSTEM.
<br />ATTACHED DEVICE MUST BE ABLE TO WITHSTAND 100% OF THE FIXTURE WEIGHT.
<br />- IF LIGHT FIXTURE IS 56 POUNDS OR LESS, MUST HAVE TWO 12-GUAGE WIRES ATTACHED
<br />AT DIAGONAL CORNERS. IF MORE THAN 56 POUNDS, MUST BE INDEPENDENTLY SUPPORTED
<br />FROM THE BUILDING STRUCTURE.
<br />2. SEE SHEET SERIES A13 FOR CEILING SYSTEM DETAILS.
<br />3. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPRINKLER
<br />HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL
<br />UNITS, UNLESS OTHERWISE NOTED.
<br />4. FINISH HVAC DIFFUSERS, DRAPERY POCKETS, AND SPEAKER GRILLES TO MATCH
<br />ADJACENT FINISH, UNLESS OTHERWISE NOTED.
<br />GENERAL NOTES
<br />mm ma
<br />1. ALL WORK SHALL CONFORM TO THE AMERICAN WITH DISABILITIES ACT (A.D.A.), WHERE
<br />APPLICABLE, ALONG WITH ALL STATE, COUNTY, AND LOCAL APPLICABLE CODES,
<br />ORDERS, ORDINANCES AND REGULATIONS. PRIOR TO START OF WORK, NOTIFY
<br />ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS AND CODE. ALL WORK
<br />SHALL CONFORM TO THE MOST RESTRICTIVE REQUIREMENTS.
<br />2. BEFORE COMMENCING WORK, CONTRACTOR SHALL BECOME FAMILIAR WITH THE
<br />DRAWINGS AND THE SCOPE OF WORK. CONTRACTOR SHALL VERIFY EXISTING
<br />CONDITIONS AND DIMENSIONS AT THE SITE. ARCHITECT SHALL BE NOTIFIED OF
<br />DISCREPANCIES.
<br />3. BEFORE COMMENCING WORK, THE GENERAL CONTRACTOR SHALL SUBMIT AN ITEMIZED
<br />COST BREAK DOWN OF ALL SCOPE ITEMS AND A CONSTRUCTION SCHEDULE TO THE
<br />BANK OF AMERICA PROJECT MANAGER AND THE ARCHITECT. WORK SHALL_ BE
<br />SCHEDULED TO MEET BAND OF AMERICA REQUIREMENTS.
<br />4. ALL WORK DESCRIBED OR INDICATED IN THESE DOCUMENTS AND ALL WORK
<br />DEPENDENT UPON OR NECESSARY TO COMPLETE THIS WORK SHALL BE EXECUTED IN A
<br />WORKMAN -LIKE MANNER CONSISTENT WITH THE BEST STANDARDS OF THE TRADE.
<br />ITEMS AND MATERIALS USED SHALL BE SUITED FOR THE INTENDED PURPOSE.
<br />5. TRADESMEN, CRAFTSMEN, INSTALLERS, FOREMEN AND SUPERVISORS ARE TO BE
<br />SKILLED, EXPERIENCED AND LICENSED IF REQUIRED IN THE WORK THEY WILL BE
<br />PERFORMING,
<br />6. PROJECT CONSTRUCTION ITEMS TO BE NE1it/', UNLESS NOTED OTHERWISE. NO
<br />SUBSTITUTIONS WILL BE ALLOWED UNLESS COMPLETE DESCRIPTIONS, DRAWINGS,
<br />TEST DATA, SAMPLES, COST AND SCHEDULED CHANGES ARE SUBMITTED BY THE
<br />CONTRACTOR AND APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. ANY ITEMS
<br />NOTED ON THE DRAWINGS THAT ARE NOT AVAILABLE OR WOULD CAUSE A TIME DELAY
<br />SHALL BE IDENTIFIED BY THE GENERAL CONTRACTOR AND THE ARCHITECT SHALL. BE
<br />NOTIFIED.
<br />7. TYPICAL DETAILS AND GENERAL NOTES SHALL BE USED WHENEVER APPLIABLE U.N.O.
<br />ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED
<br />CONSTRUCTION STANDARDS. IF CONTRACTOR HAS ANY QUESTIONS REGARDING THE
<br />SAME OR EXACT MEANING, ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION.
<br />S. DIMENSIONS ARE TO THE FACE OF FINISH ON EXISTING OR NEW WORK, UNLESS NOTED
<br />OTHERWISE. DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. LARGER SCALE
<br />DRAWINGS SHALL HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS.
<br />9. PROVIDE SHOP DRAWINGS WHERE INDICATED AND FOR ALL METAL FABRICATION OR
<br />WHERE NOTED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL
<br />SUBMIT FIVE (5) SETS TO THE ARCHITECT WITH AMPLE TIME TO REVIEW. REQUIRED
<br />CORRECTIONS WILL BE NOTED AND A COPY WILL BE RETURNED TO THE CONTRACTOR.
<br />THE CONTRACTOR SHALL REVISE THE DRAWINGS AND RESUBMIT FOR FINAL APPROVAL
<br />PRIOR TO FABRICATION.
<br />10. CONTRACTOR TO SUBMIT SAMPLES OF ALL FINISH MATERIALS TO THE ARCHITECT FOR
<br />APPROVAL PRIOR TO INSTALLATION.
<br />11. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS -BUILT DRAWINGS NOTING
<br />DEVIATIONS BETWEENTHE DRAWINGS, THE ACTUAL FIELD CONDITIONS AND THE NEW
<br />CONSTRUCTION OF ALL TRADES. AS -BUILT DRAWINGS SHALL BE DELIVERED TO BANK
<br />OF AMERICA AT THE END OF THE PROJECT. GENERAL CONTRACTOR SHALL PROVIDE
<br />ALL SUBCONTRACTORS WITH THE MOST CURRENT CONSTRUCTION DOCUMENTS
<br />THROUGHOUT THE PROJECT INCLUDING ALL REVISIONS.
<br />12. CONTRACTOR TO NOTIFY ARCHITECT AND BANK OF AMERICA PROJECT MANAGER OF
<br />ALL REVISIONS TO THE DRAWINGS AND CHANGES TO THE SCOPE OF WORK OR
<br />SCHEDULE AS REQUIRED BY GOVERNING AGENCIES, FIELD CONDITIONS OR BANK OF
<br />AMERICA PERSONNEL REGARDLESS OF EXTENT. ALL REVISIONS TO BE IN WRITING AS
<br />CHANGE ORDERS AND APPROVED PRIOR TO STARTING WORK.
<br />13. CONTRACTOR TO PROVIDE PROTECTIVE EQUIPMENT TO ENSURE THE LIFE SAFETY OF
<br />PUBLIC, TENANTS AND WORKERS AS REQUIRED BY FEDERAL, STATE .AND LOCAL CODES
<br />THROUG}-LOUT CONSTRUCTION. CONTR�iCTOR SHALL TAKE ALL 3�ECESSARY
<br />MEASURES TO PROTECT PEDESTRIANS.
<br />14. CONTRACTOR TO VERIFY EXISTING STRUCTURAL CONDITIONS AND REQUIREMENTS OF
<br />NEW CONSTRUCTION PRIOR TO START OF WORK, CONTRACTOR SHALL FURNISH
<br />ADEQUATE SHORING, BRACING, ETC. AS REQUIRED TO SAFETLY EXECUTE ALL WORK
<br />AND SHALL BE RESPONSIBLE FOR THE SAME, UNLESS SPECIFICALLY DETAILED IN THE
<br />DRAWINGS. CONTRACTOR SHALL PROVIDE BLOCKING, BACKING, FRAMING, HANGERS,
<br />OR OTHER SUPPORTS AS NECESSARY FOR ALL FIXTURES, EQUIPMENT AND ALL OTHER
<br />ITEMS AS NECESSARY.
<br />15. SITE AND BUILDING SHALL BE MAINTAINED IN A CLEAN, SAFE MANNER. DIRTY OR NOISY
<br />WORK SHALL BE PERFORMED AT SUCH A TIME AS DIRECTED BY THE OWNER AND/ OR
<br />CITY. ALL TRASH DEBRIS, SURPLUS MATERIAL, TOOLS AND EQUIPMENT TO BE
<br />REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL MANNER. LEAVE PREMISES IN
<br />A CONDITION ACCEPTABLE TO BANK OF AMERICA OR OWNER.
<br />16. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. WHERE EXISTING
<br />CONSTRUCTION, FINISHES OR EQUIPMENT IS DAMAGED BY WORK IN THIS CONTRACT, IT
<br />SHALL BE PATCHED, REPAIRED OR REPLACED AS REQUIRED TO MATCH EXISTING AT NO
<br />COST TO BANK OF AMERICA.
<br />17. THE LOCATION AND ELEVATIONS OF ALL WORK TO BE CONSTRUCTED IS SHOWN ON
<br />THE DRAWINGS. UNLESS DISCREPANCIES ARE BROUGHT TO THE ATTENTION OF THE
<br />ARCHITECT PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE HELD
<br />RESPONSIBLE FOR THE PROPER LOCATION AND ELEVATIONS AS SHOWN AND
<br />INTENDED.
<br />18. THE CONTRACTOR SHALL LAY -OUT THE WORK, ESTABLISH AND MAINTAIN NECESSARY
<br />MARKERS AND BE RESPONSIBLE FOR THE ACCURACY OF THE WORK. THE
<br />CONTRACTOR SHALL MARK, AS A GUIDE TO ALL TRADES AND TO HIS
<br />SUBCONTRACTORS, THE EXACT LOCATIONS OF NEW OR REMODELED WORK WITH
<br />RESPECT TO ALL CHANGES TO EXISTING.
<br />19. INSTALL AND APPLY ITEMS, MATERIALS, EQUIPMENT, FINISHES, ETC. INCLUDING THE
<br />PREPARATION OF SURFACES IN STRICT ACCORDANCE WITH THE MANUFACTURER'S
<br />PRINTED RECOMMENDATIONS AND INSTALLATION REQUIREMENTS.
<br />20. PERTAINING TO EQUIPMENT: GENERAL CONTRACTOR IS RESPONSIBLE FOR THE
<br />REMOVAL AND RELOCATION OF ANY EXISTING EQUIPMENT OR CONSTRUCTION AS
<br />NECESSARY FOR A COMPLETE INSTALLATION.
<br />21. ACCESS PANELS SHALL BE PROVIDED FOR ALL EQUIPMENT SWITCHES, VALVES AND
<br />OTHER CONTROL DEVICES THAT ARE CONCEALED. EXACT LOCATIONS TO BE
<br />APPROVED BY ARCHITECT PRIOR TO INSTALLATION.
<br />22. BESIDES GUARANTEES REQUIRED ELSEWHERE, THE CONTRACTOR SHALL GUARANTEE
<br />ALL WORK FOR A MINIMUM PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE OF
<br />WORK WITHOUT EXPENSE TO BANK OF AMERICA. GUARANTEE SHALL INCLUDE ANY
<br />WORK THAT MAY BE DISPLACED BY GENERAL CONTRACTOR'S WORK.
<br />23. OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES
<br />GOVERNING THE WORK.
<br />24. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT FOR
<br />REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION.
<br />25. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR'WC" UNDER SEPARATE
<br />CONTRACT. CONTRACTOR SHALL INCLUDE SCHEDULE REQUIREMENTS IN
<br />CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY
<br />SEQUENCE OF INSTALLATION.
<br />26. CONTRACTOR TO COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM
<br />INSTALLATIONS.
<br />27. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE.
<br />28. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT,
<br />CONSULT THE ARCHITECT.
<br />29. COORDINATE AND PROVIDE BLOCKING FOR MILLWORK AND ITEMS ATTACHED OR
<br />MOUNTED TO WALLS OR CEILINGS.
<br />30. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS NOTED
<br />OTHERWISE.
<br />31. CONCEALED INSULATING MATERIALS INSTALLED WITHIN WALL SHALL HAVE A FLAME
<br />SPREAD INDEX OF NOT MORE THAN 75 AND A SMOKE DEVELOPED INDEX OF NOT MORE
<br />THAN 450.
<br />32. INSULATING MATERIALS WHICH ARE SUBJECT TO DIRECT EXPOSURE TO POTENTIAL
<br />FIRE ON THE INSIDE OF THE BUILDING DUE TO INSTALLATION IN UNCONCEALED SPACES
<br />SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED
<br />INDEX OF NOT MORE THAN 450.
<br />33. MATERIALS EXPOSED WITHIN PLENUMS ARE REQUIRED TO BE NONCOMBUSTIBLE OR
<br />SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED
<br />INDEX OF NOT MORE THAN 50 AS DETERMINED IN ACCORDANCE WITH ASTM E 84.
<br />A N :I FA M EI'll C
<br />��-
<br />F
<br />1200 Sixth Avenue Tel 206.654.2100
<br />Suite 500 Fax 206.654.2121
<br />Seattle, IIUA 98101
<br />United States
<br />l
<br />JLvx $'I P
<br />JLL Third Party Project Management
<br />800 5th Avenue
<br />Seattle, VVA 98104
<br />Contact: Jim Foster
<br />jim.fosterc@am.jll.com
<br />Tel 206.375,4788
<br />z�, Date Description
<br />03/19/2021 ISSUE FOR PERMIT
<br />Project Name
<br />GREENTREE PLAZA
<br />Description
<br />GENERA, NOTES AND TYPICAL
<br />MOUNTM HEIGHTS
<br />Seale