WT= <br />• <br />iNo <br />ASSEMBLY <br />DOOR <br />FRAME <br />ASSEMBLY <br />RATING <br />HARDWARE <br />SET <br />NOTES <br />NO. <br />LOCATION <br />TYPE <br />DIMENSIONS <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />FIRE <br />RATING <br />WIDTH <br />HEIGHT <br />THICKNESS <br />100 <br />24 HR ATM <br />VESTIBULE <br />D <br />MATCH (E) <br />MATCH (E) <br />2" <br />ALUMINUM/GLASS <br />SEE GENERAL NOTE'E' <br />ALUMINUM <br />SEE GENERAL NOTE'E' <br />- <br />AL2C <br />(E) OPENING TO BE REPLACED WITH NEW STOREFRONT DOOR. GC TO <br />REVIEW SPECIFIED COMPATIBILITY WITH STOREFRONT SPECIFIED <br />AND EXISTING SYSTEM <br />101 <br />ATM ROOM <br />A <br />3'- 6" <br />T - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />11 C <br />PROVIDE PEEP SCOPE TO BE VIEWED FROM ATM ROOM 101 TO <br />CENTRAL ZONE 102 <br />102 <br />CENTRAL ZONE <br />E <br />6'- 0" <br />8'- 4" <br />1/2" <br />ALUMINUM/GLASS <br />SEE GENERAL NOTE'E' <br />ALUMINUM <br />SEE GENERAL NOTE'E' <br />- <br />01A <br />104 <br />OFFICE 1 (ME) <br />G2 <br />T - 0" <br />8'- 2" <br />- <br />ALUMINUM/GLASS <br />- <br />ALUMINUM <br />- <br />- <br />- <br />STOREFRONT SYSTEM BY BANK'S VENDOR <br />105 <br />OFFICE 2 (HL) <br />G2 <br />T - 0" <br />8'- 2" <br />- <br />ALUMINUM/GLASS <br />- <br />ALUMINUM <br />- <br />- <br />- <br />STOREFRONT SYSTEM BY BANK'S VENDOR <br />106 <br />OFFICE 6 (CB) <br />G2 <br />T - 0" <br />8'- 2" <br />- <br />ALUMINUM/GLASS <br />- <br />ALUMINUM <br />- <br />- <br />- <br />STOREFRONT SYSTEM BY BANK'S VENDOR <br />107 <br />OFFICE 3 (SB) <br />G2 <br />3' - 0" <br />8'- 2" <br />- <br />ALUMINUM/GLASS <br />- <br />ALUMINUM <br />- <br />- <br />- <br />STOREFRONT SYSTEM BY BANK'S VENDOR <br />108 <br />OFFICE 4 (CB) <br />G2 <br />3' - 0" <br />8' - 2" <br />- <br />ALUMINUM/GLASS <br />- <br />ALUMINUM <br />- <br />- <br />- <br />STOREFRONT SYSTEM BY BANK'S VENDOR <br />109 <br />OFFICE 5 (CB) <br />G2 <br />3' - 0" <br />8'- 2" <br />- <br />ALUMINUM/GLASS <br />- <br />ALUMINUM <br />- <br />- <br />- <br />STOREFRONT SYSTEM BY BANK'S VENDOR <br />110 <br />TELLER AREA <br />1 <br />3' - 0" <br />T - 0" <br />1 3/4" <br />WOOD/KEV <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />11 <br />BR DOOR BY BANK'S VENDOR, PROVIDE PEEP SCOPE TO BE VIEWED <br />FROM CORRIDOR 116 TO TELLER AREA 110 <br />111 <br />TELLERS <br />A <br />3' - 0" <br />T - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />11 <br />( PROVIDE PEEP SCOPE TO BE VIEWED FROM TELLERS 111 TO <br />CORRIDOR 116 <br />112 <br />WORK RM. <br />A <br />T - 6" <br />8'- 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />12 <br />PROVIDE PEEP SCOPE TO BE VIEWED FROM WORKROOM 112 TO <br />TELLERS 112 <br />113 <br />CALLING CUBES <br />A <br />3' - 0" <br />T - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />11 <br />PROVIDE PEEP SCOPE TO BE VIEWED FROM CALLING CUBES 113 TO <br />CORRIDOR 116 <br />114 <br />BREAK ROOM <br />A <br />T - 0" <br />T - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />11 <br />PROVIDE PEEP SCOPE TO BE VIEWED FROM BREAK ROOM 114 TO <br />CORRIDOR 116 <br />115 <br />WELLNESS ROOM <br />A <br />3' - 0" <br />T - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />16 <br />PROVIDE PRIVACY TYPE LOCK. PROVIDE 3/4" UNDERCUT AT DOOR <br />LEAF. REFER TO MECHANICAL DRAWINGS <br />116 <br />CORRIDOR <br />G1 <br />MATCH (E) <br />MATCH (E) <br />2" <br />ALUMINUM/GLASS <br />SEE GENERAL NOTE'E' <br />ALUMINUM <br />SEE GENERAL NOTE'E' <br />- <br />AL-1 <br />(E) OPENING TO BE REPLACED WITH NEW STOREFRONT DOOR. GC TO <br />REVIEW SPECIFIED COMPATIBILITY WITH STOREFRONT SPECIFIED <br />AND EXISTING SYSTEM. DOOR FOR EXITING PURPOSES ONLY. PULL <br />HANDLE FOR EXTERIOR TO BE OMITTED. <br />117 <br />MENS <br />A <br />3'- 0" <br />T - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />08 <br />PROVIDE PRIVACY TYPE LOCK. PROVIDE 3/4" UNDERCUT AT DOOR <br />LEAF. REFER TO MECHANICAL DRAWINGS <br />118 <br />WOMENS <br />A <br />3' - 0" <br />T - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />08 <br />PROVIDE PRIVACY TYPE LOCK. PROVIDE 3/4" UNDERCUT AT DOOR <br />LEAF. REFER TO MECHANICAL DRAWINGS <br />120 <br />STORAGE <br />F <br />6'- 0" <br />T - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />10 <br />PROVIDE STOREFRONT TYPE LOCK. <br />121 <br />JANITORS CLOSET <br />A <br />3'- 0" <br />T - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />09 <br />PROVIDE STOREFRONT TYPE LOCK. PROVIDE 3/4" UNDERCUT AT <br />DOOR LEAF. REFER TO MECHANICAL DRAWINGS <br />122 <br />NER <br />A <br />T - 4" <br />7' - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />10B <br />123 <br />ELECTRICAL <br />A <br />T - 0" <br />7' - 0" <br />1 3/4" <br />WOOD <br />SEE GENERAL NOTE'C' <br />HOLLOW METAL <br />SEE GENERAL NOTE'C' <br />- <br />10A <br />f <br />to mes Oka WJ a _K_ <br />06 <br />A00.42 <br />N <br />PEEP SCOPE <br />WHERE NOTED <br />� <br />IN SCHEDULE <br />w <br />J <br />� <br />PEEP SCOPE <br />® <br />�' <br />WHERE NOTED IN <br />SCHEDULE AND <br />cUn <br />REQUIRED BY CODE <br />O <br />w <br />w <br />` <br />` <br />W <br />` <br />07 <br />�� <br />`y, <br />o <br />x <br />A00.42 <br />` <br />i, <br />� <br />M <br />II EQ <br />EQ <br />II <br />1 "2"1I SEE SCHEDULE T-1 1/2" <br />TYPE A <br />SINGLE PAINT GRADE <br />SOLID CORE WOOD DOOR <br />HOLLOW METAL FRAME <br />SEE SCHEDULE <br />15, 1 112" 1 1/2" <br />SEE DOOR SCHEDULE <br />1 <br />I SEE SCHEDULE I <br />TYPE D <br />STOREFRONT DOORS <br />WIDE RAILS AND STILES <br />GLASS, ALUMINUM FRAME <br />/04 <br />A00.42 <br />/02 <br />A00.42 <br />SEE FINISH PLAN FOR DESIGNATION.vv <br />TYPE E <br />GLASS AIRLOCK <br />5" <br />5" <br />NO <br />0 <br />$/A/ <br />w <br />J <br />Ww <br />= <br />U <br />SIT <br />SH <br />VE/Z <br />FUI <br />INS <br />O <br />u <br />GL-3 <br />- <br />OT <br />GL-3 � <br />0 <br />SEE SCHEDULE <br />TE TO A/E: <br />E CONTRAC <br />ALL ORDER <br />JDOR WILL <br />ZNISH AND <br />TALL <br />YL FILM BY <br />-IERS. <br />2 SEE SCHEDULE 2" <br />TYPE F TYPE G1 TYPE G2 TYPE I <br />SOLID CORE STOREFRONT DOOR INTERIOR DOOR SINGLE PAINT GRADE <br />STAIN GRADE WOOD WIDE STILE AND RAIL WIDE STILE AND RAIL BULLET RESISTANT WOOD/KEVLAR DOOR <br />HOLLOW METAL FRAME GLASS, ALUMINUM GLASS, ALUMINUM FRAME (BY VENDOR) HOLLOW METAL FRAME <br />FRAME <br />SECURITY AT EXTERIOR ENTRY DOORS <br />> <br />w <br />Q <br />0 <br />M <br />M' <br />0 <br />0 <br />v <br />M <br />N <br />i4 <br />U <br />Q <br />m <br />0 <br />0 <br />0 <br />rn <br />CV <br />co <br />O <br />O <br />M <br />AL-2A AL-2A <br />DOOR (OUTSIDE) DOOR SECURE SIDE <br />► ►M = 11 RNW, <br />FROM EXTERIOR - LOCKED CONDITION AFTER HOURS: <br />ATM DOORS: ACCESS VIA VALID CARD WHICH UNLOCKS EXIT DEVICE ON ATM DOORS. CUSTOMERS PULL TRIM FOR <br />[ELECTRICAL] ENTRANCE. <br />FROM EXTERIOR - UNLOCKED CONDITION DURING BUSINESS HOURS: <br />ATM DOORS: PARABIT CONTROLLER HOLDS DOORS UNLOCKED ON A TIME SCHEDULE. CUSTOMERS PULL TRIM FOR <br />[ELECTRICAL] ENTRANCE. <br />FROM INTERIOR: <br />ATM DOORS: FREE EGRESS AT ALL TIMES VIA THE INSIDE DUMMY TOUCH BAR OR BY DEPRESSING THE PUSH TO EXIT <br />BUTTON. <br />SECURE LOCKDOWN FROM INTERIOR DURING BUSINESS HOURS: <br />ATM DOORS: IN THE EVENT OF AN EMERGENCY, BANK ASSOCIATE USES A KEY TO OPERATE THE INTERIOR <br />KEYSWITCH WHICH WILL OVERRIDE THE ACCESS SYSTEM AND SECURE TEH DOOR (RED LED). EGRESS <br />WILL STILL BE ALLOWED. AFTER THE EVENT, ASSOCIATE USES A KEY TO OPERATE THE KEYSWITCH <br />AND THE DOOR WILL RESUME OPERATION UNDER PARABIT CONTROLLER SYSTEM (GREEN LED). <br />EVACUATION LOCKDQWN FROM EXTERIOR DURING BUSINESS HOURS: <br />ATM DOORS: IN THE EVENT OF AN EMERGENCY, BANK ASSOCIATE TO USE INTERIOR KEYSWITCH WHICH WILL <br />OVERRIDE THE ACCESS SYSTEM AND SECURE THE DOORS (RED LED). EGRESS WILL STILL BE <br />ALLOWED AND ASSOCIATE WILL EXIT THROUGH SINGLE DOOR. AFTER EVENT, ASSOCIATE WILL <br />ENTER THE BANK BY OPERATING THE EXTERIOR KEYSWITCH WHICH UNLOCKS THE DOORS FOR 10 <br />SECONDS. AFTER ENTERING THE BANK, ASSOCIATE TO OPERATE THE INTERIOR KEYSWITCH AND <br />DOORS WILL RESUME OPERATION UNDER PARABIT CONTROLLER SYSTEM (GREEN LED). <br />QUANTITY DESCRIPTION MODEL NUMBER FINISH MFR <br />HARDWARE GROUP NO. 01A <br />2 <br />CENTER HUNG TOP PIVOT <br />CRL860BS <br />630 <br />CRL <br />W/COVER <br />2 <br />CENTER HUNG END <br />CRL801ODP <br />CRL <br />LOADED MOUNT PIVOT <br />FOR BOTTOM DOOR RAIL <br />2 <br />PANIC DEVICE/PULL <br />PA100F (TOP) W/KEY CYLINDER <br />630 <br />CRL <br />2 <br />MTSE CY, AR CAM <br />80-133 <br />626 <br />SCH <br />2 <br />SFIC EV B CORE ONLY <br />80-037 <br />626 <br />SCH <br />1 <br />POWER OPERATOR <br />ED900-CMP-J8 (BY SECURITY VENDOR) <br />695 <br />DRM <br />2 <br />PUSH PLATES <br />10PBJM1 1 OBOXJAMBSET (BY SECURITY <br />VENDOR) <br />2 <br />AUTOMATIC CAUTION <br />(The sign shall be a min of 6" in diameter with <br />DOOR SIGN <br />black lettering on a yellow background. <br />Additionally, when a knowing act switch is used to <br />initiate the operation of the door operator, the <br />doors shall be provided with signs on each side <br />of the door where <br />1 <br />ELECTRIC STRIKE <br />ESK-2 (BY SECURITY VENDOR) <br />630 <br />CRL <br />DOOR RAILS <br />REFER TO SECTION 08 41 26 <br />1 <br />CUSTOM <br />IWIRING DIAGRAM BY HARDWARE SUPPLIER <br />HARDWARE GROUP NO. 08 <br />3 <br />HINGE <br />BB1279 4.5 X 4.5 <br />26D <br />HAG <br />1 <br />PRIVACY SET <br />ND40S SPA <br />626 <br />SCH <br />1 <br />SURFACE CLOSER <br />4011 <br />689 <br />LCN <br />1 <br />KICK PLATE <br />8400 10" X 2" LDW <br />CLR <br />IVE <br />1 <br />WALL STOP <br />WS407CCV <br />630 <br />IVE <br />1 <br />SEALS <br />188S <br />CL <br />ZER <br />HARDWARE GROUP NO. 09 <br />3 <br />HINGE <br />BB1279 4.5 X 4.5 NRP <br />26D <br />HAG <br />1 <br />STOREROOM LOCK <br />ND80HD SPA <br />626 <br />SCH <br />1 <br />SFIC EV B CORE ONLY <br />80-037 <br />626 <br />SCH <br />1 <br />SURFACE CLOSER <br />4111 EDA <br />689 <br />LCN <br />1 <br />OVERHEAD STOP <br />100E <br />630 <br />GLY <br />3 <br />SILENCER <br />SR64 <br />GRY <br />IVE <br />HARDWARE GROUP NO. 10 <br />3 <br />HINGE <br />BB1279 4.5 X 4.5 NRP <br />26D <br />HAG <br />1 <br />STOREROOM LOCK <br />ND80HD SPA <br />626 <br />SCH <br />1 <br />SFIC EV B CORE ONLY <br />80-037 <br />626 <br />SCH <br />1 <br />OVERHEAD STOP <br />1 OOS <br />630 <br />GLY <br />3 <br />SILENCER <br />SR64 <br />GRY <br />IVE <br />HARDWARE GROUP NO. 1 OA <br />3 <br />HINGE <br />BB1279 4.5 X 4.5 NRP <br />26D <br />HAG <br />1 <br />PUSH BUTTON LOCK <br />5031 B WL <br />626 <br />SIM <br />1 <br />SFIC EV B CORE ONLY <br />80-037 <br />626 <br />SCH <br />1 <br />SURFACE CLOSER <br />4111 EDA <br />689 <br />LCN <br />1 <br />OVERHEAD STOP <br />100S <br />630 <br />GLY <br />3 <br />SILENCER <br />SR64 <br />I GRY <br />I IVE <br />HARDWARE GROUP NO. 10B <br />3 <br />IHINGE <br />BB1168 5 X 4.5 NRP <br />26D <br />HAG <br />1 <br />ELECTRICAL STRIKE <br />1500C (BY SECURITY VENDOR) <br />630 <br />HES <br />1 <br />LOCKSET <br />L9080 17A XL11-422 <br />626 <br />SCH <br />1 <br />MORTISE CYLINDER <br />80-101 <br />626 <br />SCH <br />1 <br />CONSTRUCTION CORE <br />80-037 <br />626 <br />SCH <br />1 <br />SURFACE CLOSER <br />4111 EDA <br />689 <br />LCN <br />1 <br />OVERHEAD STOP <br />100E <br />630 <br />GLY <br />3 <br />SILENCER <br />SR64 <br />GRY <br />IVE <br />1 <br />STRIKE GUARD <br />152 (BY SECURITY VENDOR) <br />630 <br />HES <br />1 <br />CARD READER <br />(BY SECURITY VENDOR) <br />1 <br />WIRING DIAGRAM <br />(BY SECURITY VENDOR) <br />HARDWARE GROUP NO. 11 <br />3 <br />HINGE <br />BB1279 4.5 X 4.5 <br />26D <br />HAG <br />1 <br />PUSH BUTTON LOCK <br />5031 B WL <br />626 <br />SIM <br />1 <br />SFIC EV B CORE ONLY <br />80-037 <br />626 <br />SCH <br />1 <br />SURFACE CLOSER <br />4011 <br />689 <br />LCN <br />1 <br />WALL STOP <br />WS407CCV <br />630 <br />IVE <br />1 <br />DOOR SCOPE <br />DS/2000-ALS <br />AL <br />MIS <br />3 <br />SILENCER <br />SR64 <br />GRY <br />IVE <br />HARDWARE GROUP NO. 11C <br />4 <br />HINGE <br />BB1168 5 X 4.5 NRP <br />26D <br />HAG <br />1 <br />STOREROOM LOCK <br />ND80HD SPA <br />626 <br />SCH <br />1 <br />SFIC EV B CORE ONLY <br />80-037 <br />626 <br />SCH <br />1 <br />ELECTRIC STRIKE <br />1500C (BY SECURITY VENDOR) <br />689 <br />LCN <br />1 <br />STRIKE GUARD <br />152 (BY SECURITY VENDOR) <br />630 <br />HES <br />1 <br />SURFACE CLOSER <br />4111 EDA <br />689 <br />LCN <br />1 <br />WALL STOP <br />WS407CCV <br />630 <br />IVE <br />1 <br />DOOR SCOPE <br />DS/2000-ALS <br />AL <br />MIS <br />3 <br />SILENCER <br />SR64 <br />GRY <br />IVE <br />1 <br />CARD READER <br />(BY SECURITY VENDOR) <br />1 <br />CUSTOM <br />WIRING DIAGRAM BY SECURITY VENDOR <br />HARDWARE GROUP NO. 12 <br />3 <br />HINGE <br />BB1279 4.5 X 4.5 <br />26D <br />HAG <br />1 <br />PUSH BUTTON LOCK <br />5031 B WL <br />626 <br />SIM <br />1 <br />SFIC EV B CORE ONLY <br />80-037 <br />626 <br />SCH <br />1 <br />SURFACE CLOSER <br />4111 EDA <br />689 <br />LCN <br />1 <br />WALL STOP <br />WS407CCV <br />630 <br />IVE <br />1 <br />DOOR SCOPE <br />DS/2000-ALS <br />AL <br />MIS <br />3 <br />1 SILENCER <br />SR64 <br />GRY <br />IVE <br />HARDWARE GROUP NO. 16 <br />3 <br />HINGE <br />BB1279 4.5X4.5 <br />26D <br />HAG <br />1 <br />PRIVACY SET <br />L9456HD 17A L583-363 L283-722 <br />626 <br />SCH <br />1 <br />WALL STOP <br />WS407CCV <br />630 <br />IVE <br />3 <br />SILENCER <br />SR64 <br />GRY <br />IVE <br />HARDWARE GROUP NO. AL-1 <br />4 <br />HINGE <br />BY DOOR MANUFACTURER (BALL BEARING <br />HINGES W/ NON-REMOVEABLE PINS) <br />32D <br />1 <br />PANIC HARDWARE <br />98EO <br />626 <br />VON <br />1 <br />SURFACE CLOSER <br />4111 SLUSH <br />689 <br />LCN <br />1 <br />MOUNTING PLATE <br />4110-18 <br />689 <br />LCN <br />1 <br />CUSH SHOE SUPPORT <br />4110-30 <br />689 <br />LCN <br />1 <br />BLADE STOP SPACER <br />4110-61 <br />689 <br />LCN <br />1 <br />THRESHOLD <br />325 <br />1 AL <br />NGP <br />1 <br />WEATHERSTRIPPING <br />BY DOOR MANUFACTURER <br />HARDWARE GROUP NO. AL-2C <br />8 <br />HINGE <br />BY DOOR MANUFACTURER (BALL BEARING <br />HINGES W/ NON-REMOVEABLE PINS) <br />32D <br />2 <br />POWER TRANSFER <br />EPT-2 (BY SECURITY VENDOR) <br />689 <br />HAG <br />1 <br />PANIC HARDWARE <br />QEL9847NL-OP (BY SECURITY VENDOR) <br />626 <br />VON <br />1 <br />PANIC HARDWARE <br />QEL9847 (BY SECURITY VENDOR) <br />626 <br />VON <br />1 <br />RIM CYL W/ <br />CONSTRUCTION CORE <br />80-159 <br />626 <br />SCH <br />1 <br />SFIC EV B CORE ONLY <br />80-037 <br />626 <br />SCH <br />2 <br />DOOR PULL <br />RM2110-78" 1-1/4" (2 STANDOFFS PER PULL) <br />630 <br />ROC <br />2 <br />WOOD PULL BAR <br />(ALTERNATE) <br />RM4010-78" 1-1/4"" (2 STANDOFFS PER PULL) <br />630 <br />ROC <br />1 <br />POWER OPERATOR <br />ED900-CMP-J8 (BY SECURITY VENDOR) <br />689 <br />DRM <br />2 <br />PUSH PLATES <br />1 OPBJM1 1 OBOXJAMBSET (BY SECURITY <br />VENDOR) ALTERNATE: 1 OPBS1 <br />1 OBOX475SQSM; SEE DIAGRAM BELOW FOR <br />LOCATIONS <br />2 <br />AUTOMATIC CAUTION <br />DOOR SIGN <br />(The sign shall be a min of 6" in diameter with <br />black lettering on a yellow background. <br />Additionally, when a knowing act switch is used to <br />initiate the operation of the door operator, the <br />doors shall be provided with signs on each side <br />of the door where <br />1 <br />THRESHOLD <br />325 <br />AL <br />NGP <br />1 <br />KEYSWITCH <br />653-14-NS-L2 <br />630 <br />SCE <br />1 <br />POWER SUPPLY <br />PS914-21RS <br />GRY <br />VON <br />1 <br />WEATHERSTRIPPING <br />BY DOOR MANUFACTURER <br />1 <br />ICARD READER <br />(BY SECURITY VENDOR) <br />1 <br />ICUSTOM <br />I WIRING DIAGRAM BY SECURITY VENDOR <br />411L9■a"T19 <br />10PBJM1 1OBOXJAMBSET <br />USED WHERE NO WALL AREA IS PROVIDED, INSTALLED ON <br />STOREFRONT MULLION - AT ALL LOCATIONS WHERE <br />NOTED EXCEPT DOOR#100 FOR EXTERIOR <br />PUSH PLATE - ALT 1 <br />10PBS1 10BOX475SQSM <br />PREFERRED OPTION FOR WALL MOUNTED -AT <br />EXTERIOR LOCATION FOR DOOR#100 ONLY <br />A. REFER TO SPECIFICATIONS FOR DOOR HARDWARE <br />GROUPS. <br />B. EXTERIOR CURTAIN WALL, STOREFRONT, DOORS <br />AND FRAMES TO HAVE CLEAR ANODIZED FINISH. <br />C. PAINT DOORS AND DOOR FRAMES TO MATCH <br />ADJACENT PARTITION UNLESS NOTED OTHERWISE. <br />D. NOT USED. <br />E. DOOR RAILS/ FRAME TO BE CLEAR ANODIZED <br />FINISH. <br />F. ALL DOOR HARDWARE SHALL BE LEVER TYPE <br />MEETING ACCESSIBILITY DESIGN REQUIREMENTS. <br />G. ALL DOOR HARDWARE SHALL BE SATIN CHROME <br />FINISH (US26D), UNLESS OTHERWISE INDICATED. <br />H. COORDINATE ALL HARDWARE KEYING WITH THE <br />OWNER AND OBTAIN OWNER'S APPROVAL PRIOR TO <br />PLACING HARDWARE ORDER. <br />I. REFER TO FINISH SCHEDULE FOR WOOD DOOR <br />FINISHES. <br />J. FOR EXTERIOR HOLLOW METAL DOORS, PAINT <br />FRAME AND DOOR ON INTERIOR SIDE TO MATCH <br />ADJACENT PARTITION COLOR. PAINT FRAME AND <br />DOOR ON EXTERIOR SIDE EXPT-2. <br />K. REFER TO SHEET A00.10 FOR ADDITIONAL GENERAL <br />DOOR NOTES. <br />ITEM <br />DESCRIPTION <br />VHINGE <br />TRANSFER: ELECTRICAL POWER TRANSFER <br />CPANIC <br />HARDWARE <br />PUSH PLATE <br /><E> <br />KEY SWITCH: (RECESS MOUNTED ON <br />INTERIOR JAMB FRAME) <br />CYLINDER: (TEMPORARY CYLINDER USED <br />DURING CONSTRUCTION; TO BE REPLACED <br />WITH ITEM "0" AFTER CONSTRUCTION <br />GCLOSER <br />PULL HANDLE <br /><>SWEEP <br />WEATHERSTRIP <br />THRESHOLD <br /><*> <br />DOUBLE MAGLOCK <br />MINI MULLION READER <br />® <br />PERMANENT CYLINDER <br />�t <br />PUSH PLATE <br />< > <br />CARD READER (SURFACE MOUNTED ON <br />EXTERIOR JAMB FRAME) <br />RELECTRIC <br />STRIKE <br />TEXIT <br />BUTTON <br />U <br />< > <br />PASSIVE INFRARED DETECTOR <br />L <br />305 SE EVERETT MALL WAY, STE 31 <br />EVERETT, WA 98208 <br />SERIAL NUM./MANH. ID: WA4-158 <br />NRSP VERSION: 3.0 <br />BULLETIN: 04-2020 <br />JLL Third Party Project Management <br />800 5th Avenue <br />Seattle, WA 98104 <br />Contact: Jim Foster <br />jim.foster@am.jll.com <br />Tel 206.375.4788 <br />Date Description <br />03/19/2021 ISSUE FOR PERMIT <br />Seal I Signature <br />9961 <br />�N. ARC81TrCT <br />LMVIS CHU <br />STATH OF WASIMMON <br />Project Name <br />GREENTREE PLAZA <br />Project Number <br />032.4596.003 <br />Description <br />■:� <br />Scale <br />3/8if = 1'-0" <br />M <br />© 2021 Gensler <br />