Laserfiche WebLink
4 1 <br />3 1 <br />2 I 1 <br />U <br />O <br />00 <br />FRP-3 <br />CI I <br />Ip vma,>e.. au , <br />,..w..a. a. �­_­-:­ <br />Y <br />I <br />� <br />C4 .TOILET ROOM E <br />FI <br />AUTOMATIC <br />HAND DRYER <br />IONS - TYPICAL <br />TOILET TISSUE <br />DISPENSER <br />w � <br />Wm0Q O <br />==w�cn <br />v=0 w <br />Q <br />s2 <br />in <br />a <br />1-1/2" D►A. STAINLE <br />STEEL GRAB BAR <br />0--'L-T / 3" = 1'-0" <br />SEAT COVER <br />DISPENSER <br />ID <br />20 GA. TRACK <br />SECURED TO STUDS <br />(3) 14 X 2-1/2" TYPE 304 <br />STAINLESS STEEL PHILLIPS <br />ROUND -HEAD, SHEET <br />METAL SCREWS <br />PARTITION AS <br />SPECIFIED <br />AT WATER AND DRAIN LINESy <br />BELOW LAVATORY <br />m <br />(V <br />M J <br />LL <br />w <br />IY <br />J <br />MIRROR <br />WALL MOUNTED WATER <br />LAVATORY CLOSET <br />h <br />�O <br />za <br />�O <br />� �Q a. <br />> _U <br />OF <br />4 <br />1) GC TO INSTALL WITH MOUNTING KIT # 252-30. <br />2) THE STRUCTURAL STRENGTH OF GRAB BARS SHALL MEET THE FOLLOWING SPECIFICATIONS <br />(A) BENDING STRESS IN A GRAB BAR INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE <br />APPLICATION OF 250 LBF (1112N) SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE <br />MATERIAL OF THE GRAB BAR. <br />(B) SHEAR STRESS INDUCED IN A GRAB BAR BY THE APPLICATION OF 250 LBF (1112N) SHALL BE <br />LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR, IF THE <br />CONNECTIONS BETWEEN THE GRAB BAR AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS <br />CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES <br />SHALL BE TOTALED FOR THE COMBINED SHEAR STRESS, WHICH SHALL NOT EXCEED THE <br />ALLOWABLE SHEAR STRESS. <br />(C) SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE APPLICATION OF <br />250 LBF (1112N) SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER <br />OR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER <br />ALLOWABLE LOAD. <br />(D) TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF 250 LBF (1112N) <br />PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF 250 LBF (1112N) SHALL BE LESS THAN <br />THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND THE SUPPORTING <br />STRUCTURE. <br />I (E) GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. I <br />I I <br />7" MIN. <br />9"MAX. <br />A - - - _ — <br />I I <br />D C4 B <br />C <br />5'-0" X 5'-0°' ` <br />CLR. SPACE <br />Is OAP I <br />Z ` TOILET ; I ACCESSIBILITY <br />U ROOM i I I SIGNAGE. SEE <br />M ` _ t - - i SHEET 62 / 0002 <br />I <br />O <br />ir) I I <br />RECESSED <br />HAND DRYER <br />O O O 30„ X 48" <br />CLEAR SPACE <br />6", Z-0" 1, 6" <br />MAX 3'4' <br />1 "-6" <br />5'-0" <br />rC2)1NLA�RGED TOILET ROOM PLAN <br />A CLEAR FLOOR SPACE <br />LAVATORY D ETAI L <br />r� s " <br />w` / 'IF2" = 1'-U" <br />ADA SIGN DESCRIPTION <br />MODEL # <br />SIGNAGE <br />WINDOW / COUNTER DECAL SYMBOL OF ACCESSIBILITY - SIZE 6" X 6" <br />ADA-1006 <br />"EXIT" - SIZE: 6" X 6"; W/ ADA/CBC BRAILLE <br />ADA-1242 <br />Exl <br />"EXIT ROUTE" - SIZE: 6" X 6"; W/ ADA/CBC BRAILLE <br />ADA-1243 <br />WHEELCHAIR ACCESSIBLE ENTRANCE - <br />SIZE: 6" X 8" <br />ADA-1070F <br />"WOMEN" WHEELCHAIR ACCESSIBLE RESTROOM - WALL - SIZE: 6" X 8" <br />ADA-1024 <br />"MEN" WHEELCHAIR ACCESSIBLE RESTROOM - WALL - SIZE: 6" X 8" <br />ADA-1025$ <br />"ALL GENDER" WHEELCHAIR ACCESSIBLE RESTROOM - WALL - SIZE: 8" X 8" <br />ADA-1026� <br />"ALL GENDER" ACCESSIBLE RESTROOM-TACTILE BRAILLE -WALL-8"X9" <br />ADA-1245 <br />"WOMEN" ACCESSIBILE RESTROOM - DOOR - SIZE: 12" DIA, CIRCLE <br />T24-1001 <br />"MEN" ACCESSIBLE RESTROOM - DOOR - SIZE: 12" TRIANGLE <br />T24-1000 <br />A�6 <br />"ALL GENDER" WHEELCHAIR ACCESSIBLE RESTROOM - DOOR - 12" <br />TRIANGLE / CIRCLE <br />T24-1003 <br />"ALL GENDER" WHEELCHAIR ACCESSIBLE RESTROOM-DOOR -12' X 12" <br />ADA-1251 <br />G.0 IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL ACCESSIBLE SIGNAGE. SIGNAGE TO BE ADA WHITE ON <br />BLUE AVAILABLE FROM WWW.ADASIGNDEPOT.COM *NOT ALL USED AT THIS LOCATION <br />MIRROR <br />L w > <br />J1 IL P w <br />�KN <br />?r _ N N M O <br />I <br />ADA TRAP GUARD <br />8"MIN. 6"MAX <br />KNEE CLEARANCE TOE CLEARANCE <br />B MOUNTING HEIGHTS. <br />..obi <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />W W W. T-Mobi le,com <br />COPYRIGHT NOTICE: <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO <br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF <br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003, THE PROTECTION <br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND <br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH <br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS <br />MAY RESULT W CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR <br />MONETARY LIABILITY. <br />ARCHITECT: <br />Design <br />Forum 2056 Byers Road <br />Architects ,:, Miamisburg, Ohio45342 <br />844.804.7700: <br />ChangeUP <br />07/06/21 <br />CONSULTING ENGINEER: <br />CASE <br />Engineering Inc. <br />796 Mems Court T 636.349.1600 <br />St. Louis, MO 63026 F 636.349.173'1 <br />CERTIFICATE OF AUT110RITY NO. 9180 <br />UJI <br />y♦ <br />V <br />i <br />L.)�:N <br />W <br />< <br />co <br />n <br />- �;w <br />W <br />W <br />W <br />Uj <br />W <br />W <br />(f) <br />CO <br />W <br />W <br />1. DISPENSERS THAT CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER <br />FLOW SHALL NOT BE USED. <br />2. INTERIOR SURFACES - TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD, <br />NON -ABSORBENT SURFACE, SUCH AS PORTLAND CEMENT, CONCRETE, CERAMIC TILE, OR <br />OTHER APPROVED MATERIALS WHICH EXTEND UPWARD ONTO THE WALLS AT LEAST 511 <br />. <br />3. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES OR SINKS. <br />4. PROVIDE BLOCKING AT ALL WALL MOUNTED FIXTURES AND ACCESSORIES. <br />1. FRAMES MIRROR: BOBRICK B-1652436 <br />2. SEAT COVER DISPENSER: ITEM #420660 <br />3. GRAB BAR: BOBRICK B06806 (36"L, 42"L, AND 18"L WHEN REQUIRED) <br />4. AUTOMATIC HAND DRYER: EXCEL XL-SB WITH ADA RECESSED MOUNTING KIT 40502 <br />5. TOILET PAPER DISPENSER: BOBRICK B-2888 CITY OF EVERETT <br />6, DOOR COAT HOOK: BOBRICK B-6827 REVIEWEDFOR PERMIT <br />^k SKxv.;`S € m. ,, �,: w�'* <br />i�^,,`y^'-. L-• •. m y" g2' "_. 4J3Fu at.# <br />DATE: July 02, 2021 <br />SCALE: AS NOTED <br />DRAWN BY: PT <br />SAP NUMBER: <br />2SDX <br />CORPORATE REBUILD CD <br />LDC <br />SHEET TITLE: <br />ENLARGED TOILET ROOM <br />SHEET NUMBER: <br />A401 <br />4 <br />3 1 <br />2 1 <br />1 <br />