811 SE EVERETT MALL WAY 2021 T MOBILE Plans 2022-11-02
>
Address Records
>
SE EVERETT MALL WAY
>
811
>
T MOBILE
>
Plans
>
811 SE EVERETT MALL WAY 2021 T MOBILE Plans 2022-11-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2022 11:00:30 AM
Creation date
12/14/2021 8:58:16 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
811
Tenant Name
T MOBILE
Permit
B2107-045
Year
2021
Notes
TI: Interior remodel of extg T-Mobile store. New partitioned walls, fixtures
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />4 <br />I <br />w1 <br />IE <br />m <br />1. THE LIGHTING IN EACH ENCLOSED ROOM (TELCO, INVENTORY, MEN'S RESTROOM, WOMEN'S RESTROOM) SHALL BE <br />CONTROLLED BY LOCAL OCCUPANCY SENSOR(S). <br />2. THE REMAINDER OF THE LIGHTING SHALL BE CONTROLLED VIA AUTOMATIC LIGHTING CONTROL SYSTEM AND SHALL <br />INCLUDE A 365 DAY ASTRONOMICAL TIMECLOCK, THE TIME CLOCK SHALL HAVE A NON-VOLATILE PROGRAM MEMORY. <br />EACH LIGHTING CONTROL RELAY SHALL HAVE AN INTEGRAL OVERRIDE SWITCH THAT ALLOWS FOR INDEPENDENT <br />OVERRIDE. <br />3. THERE SHALL BE TWO ON/OFF SWITCHES (CONTROL FUNCTIONS) FOR THE AUTOMATIC LIGHTING CONTROL SYSTEM, <br />DEFINED BELOW: <br />GENERAL LIGHTING FUNCTION (MANUAL ON/SCHEDULED OFF) <br />A. SWITCH SHALL CONTROL ALL GENERAL LIGHTING LOCATED IN THE SALES AREA AND BACK OF HOUSE (BOH). WHEN <br />PRESSED TO THE ON POSITION, ALL LIGHTING SHALL BE ENERGIZED. ONCE ENERGIZED, THE LIGHTING CONTROL <br />SYSTEM SHALL AUTOMATICALLY DE -ENERGIZE ALL LIGHTING AT STOKE CLOSE, UNLESS SWITCH IS PRESSED TO <br />THE OFF POSITION PRIOR TO STORE CLOSE. <br />B. SWITCH SHALL ALSO OPERATE AS A TIMED OVERRIDE. WHEN PRESSED TO THE ON POSITION BEYOND STORE <br />CLOSE, ALL LIGHTING SHALL BE ENERGIZED FOR A MAXIMUM DURATION OF 2 HOURS. <br />C. ALL LIGHTING SHALL BE PROGRAMMED WITH BLINK FUNCTION; 5 MINUTES PRIOR TO AUTOMATIC SHUTOFF. <br />ACCENT LIGHTING FUNCTION (MANUAL ON/SCHEDULED OFF) <br />A. SWITCH SHALL CONTROL ALL ACCENT, FIXTURE (CASEWORK), SIGNAGE , AND SHOW WINDOW LIGHTING. WHEN <br />PRESSED TO THE ON POSITION, ALL LIGHTING SHALL BE ENERGIZED 30 MINUTES PRIOR TO STOKE OPENING. <br />ONCE ENERGIZED, THE LIGHTING CONTROL SYSTEM SHALL AUTOMATICALLY DE -ENERGIZE ALL LIGHTING AT <br />STORE CLOSE, UNLESS SWITCH IS PRESSED TO THE OFF POSITION PRIOR TO STORE CLOSE. <br />B. SWITCH SHALL ALSO OPERATE AS A TIMED OVERRIDE. WHEN PRESSED TO THE ON POSITION BEYOND STORE <br />CLOSE, ALL LIGHTING SHALL BE ENERGIZED FOR A MAXIMUM DURATION OF 2 HOURS. <br />3 SECURITY LIGHTING FUNCTION (AUTOMATIC ON/MANUAL OFF <br />A. ALARM CONDITION FROM SECURITY SYSTEM SHALL ENERGIZE ALL GENERAL LIGHTING. LIGHTING SHALL REMAIN <br />ENERGIZED UNTIL MANUALLY DE -ENERGIZED. <br />4. THREE PROGRAMMED TIMED SET POINTS SHALL BE SET FOR THIS SYSTEM. <br />A. STORE OPEN <br />B. STORE CLOSE <br />C. 30 MINUTES PRIOR TO STORE OPENING <br />5, VERIFY ALL TIDIED SET POINTS WITH OWNER AND ADJUST ACCORDINGLY PER MFG RECOMMENDATIONS. <br />6. A DAYLIGHTING SWITCH WILL BE IMPLEMENTED AS REQUIRED BY ENERGY CODES. <br />7. INITIAL PROGRAMMING OF THIS SYSTEM SHALL BE PERFORMED BY THE INSTALLING CONTRACTOR, PER MFG. <br />RECOMMENDATIONS. <br />NOTE: ALL LIGHTING FOR THIS PROJECT SHALL BE WIRED TO OBTAIN THE ABOVE CONTROL SYSTEM DESCRIPTIONS. <br />COORDINATE PROGRAMMING OF AUTOMATIC LIGHTING CONTROL SYSTEM WITH MFG. PRIOR TO INSTALLING. <br />HVAC CONTROL <br />1. EACH HVAC UNIT WILL BE CONTROLLED DIRECTLY FROM A PROGRAMMABLE THERMOSTAT. THE SYSTEM WILL BE <br />CYCLED TO MAINTAIN THE ZONE TEMPERATURE SET POINT. <br />2. THE TIME SCHEDULE FOR THE HVAC EQUIPMENT WILL BE SET TO ALLOW THE STORE TO BE AT OCCUPIED <br />TEMPERATURES WHEN THE STORE OPENS FOR CUSTOMERS AND THEN TO UNOCCUPIED MODE WHEN THE STORE <br />CLOSES. <br />3. THE HVAC WILL RETURN TO OCCUPIED MODE FOR 1 HOUR WHEN AN OVERRIDE BUTTON IS PRESSED. <br />RESTROOM EXHAUST FAN <br />4. THE RESTROOM EXHAUST FAN WILL BE CONTROLLED WITH THE RESTROOM'S OCCUPANCY SENSORS; 10-MINUTE <br />OFF -DELAY. <br />FAN CONTROL <br />5. THE FAN WILL. BE SET TO RUN CONTINUOUS DURING STORE OPEN HOURS TO PROVIDE VENTILATION AND AIR <br />CIRCULATION. <br />6. IN SETBACK OR UNOCCUPIED MODE, THE FAN WILL RUN ONLY WHEN THERE IS A CALL FOR HEATING OR COOLING. <br />COOLING CONTROL <br />7. THE INITIAL SET POINT FOR OCCUPIED HOURS WILL BE 75 DEGREES. <br />6. THE INITIAL SET POINT FOR UNOCCUPIED HOURS WILL BE 35 DEGREES. <br />9. AIR CONDITIONING SYSTEM WILL HAVE A MINIMUM ON AND MINIMUM OFF TIME OF TWO MINUTES TO PREVENT SHORT <br />CYCLING. <br />HEATING CONTROL <br />10. THE INITIAL SET POINT FOR OCCUPIED HOURS WILL BE 63 DEGREES. <br />11. THE INITIAL SET POINT FOR UNOCCUPIED HOURS WILL BE 55 DEGREES. <br />w 4 I`mill Pollq 3 E <br />11 <br />I <br />IN <br />I <br />Wil <br />GENERAL LTS <br />SWITCH ENABLES AUTOMATIC CONTROL OF ALL <br />GENERAL LIGHTING DURING STOKE HOURS. <br />LIGHTS SHALL BLINK 5 MINUTES PRIOR TO <br />AUTOMATICALLY TURNING OFF. PRESS ON/OFF <br />TO PROVIDE OVERRIDE OF LIGHTS. <br />ALARM CONDITION FROM ADT SECURITY SYSTEM <br />TURNS ON ALL GENERAL LIGHTING. LIGHTS WILL <br />REMAIN ON UNTIL MANUALLY TURNED OFF. <br />mliffigmumff <br />1. SWITCH ENABLES AUTOMATIC <br />CONTROL OF ALL ACCENT <br />LIGHTING DURING STORE HOURS. <br />2. PRESS ON/OFF TO PROVIDE <br />OVERRIDE OF LIGHTS. <br />SALES <br />SALES <br />SALES <br />GENERAL <br />GENERAL/EM <br />DISPLAY <br />� <br />1 <br />L1 <br />L2 <br />L3 <br />ENTOUCH <br />DLC <br />DIMMING & LOAD <br />CONTROLLER <br />SWITCHBANK DETAIL <br />NTS <br />I <br />j <br />i <br />BOH <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />vuvwt-mobiio.com <br />COPYRIGHT NOTICE: <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT <br />TO COPYP.IGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. <br />102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE <br />PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, <br />ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE <br />DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE <br />DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF <br />CONSTRUCTION, BUILDING SEIZURE, AND/OR MONETARY LIABILITY. <br />ARCHITECT <br />Dcinald J. RcWiruan <br />Charg4-- <br />"ILA <br />2056 Byers Erb <br />An' Ohio 45342 <br />hr, 1, . .. anµ 843,U04Y73:0 <br />07/02/2021 <br />CONSULTING ENGINEER: <br />DATE: 07/02/2021 <br />SCALE: AS NOTED <br />DRAWN BY: JVH <br />SAP NUMBER: <br />m <br />0 <br />0 <br />1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.