m <br />ME <br />ml <br />0 <br />1 A SCOPE <br />1.1 THE COMPLETE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. <br />CONSULT LANDLORD'S DESIGN CRITERIA. <br />1.2 THE DRAWINGS AND THE SPECIFICATIONS SHALL BE CONSIDERED ADDITIONAL_ TO ARCHITECT AND MECHANICAL <br />ENGINEER'S SPECIFICATIONS. ANY DISCREPANCY OR CONTRADICTION SHALL BE BROUGHT <br />TO THE ATTENTION OF THE ENGINEER. <br />1.3 ARCHITECT'S GENERAL REQUIREMENTS ARE PART OF THIS CONTRACT. AND THEY SHALL BE APPLIED BY <br />THE GENERAL CONTRACTOR AND SUBCONTRACTORS (ELECTRICAL,ETC..). <br />1.4 ONCE ONSITE GENERAL CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH ANY CONDITIONS THAT MAY AFFECT HIS <br />WORK IN ANY MANNER PRIOR TO START OF CONSTRUCTION. (MEASUREMENTS - PARTICULAR CONDITIONS, ETC...) <br />GENERAL CONTRACTOR SHALL NOTIFY TENANT REPRESENTATIVE AND ARCHITECT OF ANY SUCH CONDITIONS PRIOR TO <br />COMMENCEMENT OF WORK. <br />1.5 GENERAL CONTRACTOR SHALL MAKE ALL NECESSARY CHECKING AND ADJUSTMENTS TO COMPLY WITH THE INTENT <br />OF SPECIFICATIONS. <br />1.6 THE DRAWINGS SHOW THE APPROXIMATE LOCATION OF THE EQUIPMENT. EACH SUBCONTRACTOR SHALL VERIFY <br />THESE LOCATIONS BEFORE INSTALLATION. <br />1.7 GENERAL CONTRACTOR'S TENDER SHALL INCLUDE THE COST OF ALL NECESSARY PERMITS AND CERTIFICATES, ALL <br />DRAWINGS APPROVAL COSTS AND ALL INSPECTION COSTS REQUIRED BY ALL AUTHORITIES HAVING JURISDICTION. <br />1.8 EACH SUBCONTRACTOR SHALL COMPLETE THE WORK IN EVERY DETAIL. EVEN THOUGH NOT SHOWN ON DRAWINGS <br />OR CALLED FOR IN THIS SPECIFICATION. <br />1.9 THE ELECTRICAL TRADE SHALL PROVIDE ALL LABOR AND MATERIALS NECESSARY FOR A COMPLETE AND OPERATING <br />ELECTRICAL SYSTEM AS INDICATED ON THE DRAWINGS. THE TRADE SHALL ALSO PROVIDE ANY ITEMS AND/OR LABOR <br />THAT ARE OBVIOUSLY NECESSARY OR REASONABLY IMPLIED TO COMPLETE ALL WORK. <br />1.10 ALL ELECTRICAL WORK TO BE DONE IN ACCORDANCE WITH APPLICABLE EDITIONS AND AMENDMENTS OF THE <br />NATIONAL ELECTRICAL CODE (NEC), NFPA AND ALL LOCAL CODES ADOPTED BY THE LOCAL JURISDICTION HAVING <br />AUTHORITY. <br />l A l ALL RUBBISH'S AND GARBAGE SHALL BE REMOVED FROM THE JOB SITE AT THE END OF EVERY WORKDAY. AT THE <br />CONTRACT COMPLETION, ALL TOOLS AND EQUIPMENT SHALL BE REMOVED AND <br />THE JOB SITE SHALL BE LEFT IN A CLEAN CONDITION.. <br />2.0 GUARANTEE <br />2.1 EACH SUBCONTRACTOR SHALL GUARANTEE HIS WORK AND INSTALLATION REGARDING HIS CONTRACT. THE <br />ELECTRICAL CONTRACTOR SHALL REPAIR OR REPLACE, AT HIS OWN EXPENSE, ALL DEFECTS AND THIS DURING A TWELVE <br />MONTHS PERIOD, STARTING AT THE PROVISIONAL ACCEPTANCE BY THE TENANT. AS LONG AS THE DEFECTS IS NOT DUE <br />TO A BAD USE OR NORMAL WEAR. <br />3.0 TAXES <br />3.1 EACH SUBCONTRACTOR SHALL PAY ALL APPLICABLE TAXES, FOR LABOR AND MATERIAL INCLUDED IN HIS TENDER <br />4.0 TEMPORARY SERVICES <br />4.1 ALL TEMPORARY LIGHTING (MIN. 20OLUX WITH MH HALIDE FIXTURE) AND POWER DURING CONSTRUCTION SHALL BE <br />BY GENERAL CONTRACTOR AFTER AGREEMENT WITH ELECTRICAL CONTRACTOR AND SHALL BE TAKEN FROM EXISTING <br />PANEL SERVING THE SPACE, SUPPLY VOLTAGE AND AMPS AS REQUIRED. <br />5.0 SHOP DRAWINGS <br />5.1 PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT SUBMIT TO ENGINEER FOR APPROVAL A MINIMUM OF TWO (2) <br />COPIES OF SHOP DRAWINGS FOR EACH ITEM OF EQUIPMENT <br />6.0 ALTERNATE EQUIPMENT <br />6.1 PROPOSAL SHALL BE BASED ON SPECIFIED EQUIPMENT AND MATERIAL. <br />6.2 PROPOSAL FOR ALTERNATE TO SPECIFICATION SHALL INCLUDE MANUFACTURER NAME, MODEL AND COST <br />MODIFICATION, <br />6.3 COST OF ANY CHANGE REQUIRED TO OTHER TRADES WORK. DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT, <br />SHALL BE INCLUDED IN THE SUBCONTRACTOR'S PROPOSAL CALLING FOR THIS SUBSTITUTION. EVEN IF THESE CHANGES <br />APPEAR AFTER THE DEMAND FOR SUBSTITUTION. <br />6.4 ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE CONTRACTS ARE AWARDED. NO CHANGES WILL <br />BE ALLOWED AFTER THE CONTRACT IS SIGNED. <br />7.0 IDENTIFICATION <br />7.1 ALL ELECTRICAL EQUIPMENT (SWITCHES, PANELS, CIRCUITS ETC..) MUST BE PROPERLY IDENTIFIED WITH LAMICOID <br />NAME PLATES SCREWED ON PANELS AND HAVE A TYPED DIRECTORY AND INDICATE LOAD ON <br />EACH CIRCUIT. <br />8.0 GROUND <br />8.1 THE GROUND SHALL BE CONTINUOUS AND SHALL BE CONFORM TO THE APPLICABLE EDITION OF THE NATIONAL <br />ELECTRICAL CODE. <br />9.0 PULLING AND JUNCTION BOXES <br />9.1 TRADE WILL PROVIDE PULLING AND JUNCTION BOXES WITH SCREWED PLATED COLOR MATCHED FOR WALL AND <br />CEILING FINISHES. <br />9.2 ALL BOXES SHALL BE ACCESSIBLE. <br />9.3 BACK TO BACK BOXES WILL NOT BE ACCEPTED. <br />9.4 PULL BOXES SHALL BE LOCATED EVERY 100 FEET (30m) AND EVERY TWO 90 DEG, ELBOW, <br />9.5 ALL SURFACE MOUNTED BOXES FOR JUNCTION, SOCKETS, SWITCHES, FIXTURES ETC .... SHALL BE F.S. TYPE. <br />10.0 DRILLING <br />10.1 ELECTRICAL CONTRACTOR SHALL DRILL OR SAW CUT THE FLOOR WHERE REQUIRED. ELECTRICAL CONTRACTOR <br />SHALL PROVIDE AND INSTALL SLEEVES IN CONCRETE SLAB, WHERE REQUIRED. <br />10.2 NO ELECTRICAL OR PNEUMATIC HAMMER SHOULD BE USED. <br />10.3 EXISTING CONCRETE COLUMNS ARE NOT TO BE CHANNELED OR NOTCHED. <br />11.0 WIRING AND CONDUIT <br />11.1 ALL WIRING, WILL BE COPPER TYPE, No.12 AWG MINIMUM, UNLESS OTHERWISE NOTED. <br />11.2 ALL SURFACE WIRING, SHALL BE THWN TYPE IN E.M.T. CONDUIT. ALL COUPLINGS TO BE RAIN TIGHT OR GALVANIZED <br />SET CREW TYPE. <br />11.3 ALL WIRING AND CONDUIT, WILL BE RECESSED IN WALL OR CEILING (INCLUDING EXISTING ARCHITECTURAL <br />ELEMENTS) UNLESS APPROVED BY LOCAL INSPECTOR AND AHJ. ELECTRICAL CONTRACTOR TO VERIFY. <br />11.4 ALL CONDUIT SHALL BE PARALLEL WITH ARCHITECTURAL LINES AND DESIGN. <br />11.5 FOR SUSPENDED CEILING, MC CABLE FOR 15 FEET (4.5m) IS ACCEPTED. MAIN WIRING TO BE THWN IN E.M.T. CONDUIT. <br />11.6 ALL EMPTY CONDUIT SHALL INCLUDE A PULLING WIRE No.12 AWG. -MAX. 6'-0" FLEXIBLE CONDUIT MAYBE USED FOR <br />FIXTURE AND EQUIPMENT CONNECTIONS ONLY. PLASTIC CONDUIT IS NOT ACCEPTED. <br />12.0 FIRE BARRIER: <br />12.1 IN CASE OF CROSSING A FIRE BARRIER (FLOOR, WALL, OR CEILING) FILL GAP WITH APPROPRIATE MATERIAL. THIS <br />MATERIAL SHALL BE EFFICIENT BARRIER FOR FLAME, FUME AND GAS. SEAL AT SMOKE WALL. <br />I <br />13.0 EXPANSION JOINT <br />13.1 EACH TIME ELECTRICAL CONDUIT PASS THROUGH AN EXPANSION JOINT OF THE BUILDING USE GALVANIZED STEEL <br />SLIDING TYPE EXPANSION JOINT WITH CONTINUOUS COPPER GROUNDING. FLEXIBLE AT THESE LOCATIONS. <br />14.0 FIXTURES AND LAMPS <br />14.1 COMPLETE LIGHTING PACKAGE IS OWNER (OR LANDLORD) FURNISHED (REFER TO LEASE AGREEMENT), GC <br />INSTALLED. ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES, LAMPS AND CONTROLS PER MANUFACTURER <br />SPECS AND RDSS (ENERGY DESIGN SERVICE SYSTEMS) INSTALLATION INSTRUCTIONS. <br />15.0 FIELD CONDITIONS <br />15.1 ENGINEER CAN RELOCATE ALL EQUIPMENT (FIXTURES, OUTLETS, ETC...), AT NO COST, IF DISPLACEMENT IS LESS <br />THAN 10 FEET (3m), AND WRITTEN NOTICE IS SENT TO CONTRACTOR PRIOR TO INSTALLATION, <br />15.2 CONFER WITH ALL OTHER TRADES AND ARRANGE EQUIPMENT IN PROPER RELATION WITH OTHER APPARATUS, <br />DUCTS, PIPES, ETC. AND WITH BUILDING CONSTRUCTION AND ARCHITECTURAL FINISHES. <br />16.0 EXISTING CONDITIONS <br />16.1 ELECTRICAL CONTRACTOR WORK AFFECTING OTHER TENANT SHALL BE DONE OFF BUSINESS HOURS (NIGHT OR <br />WEEK -END). COORDINATE WITH THE LANDLORD, <br />16.2 ELECTRICAL CONTRACTOR SHALL REMOVE AND LEGALLY DISPOSE ANY UNUSED MATERIAL. <br />16.3 ANY NON REUSED MATERIAL SHALL BE GIVEN BACK IN GOOD CONDITION TO LANDLORD <br />16.4 ANY DAMAGED WALL, FLOOR, CEILING, FINISHES SHALL BE REPAIRED BY GENERAL CONTRACTOR THOSE REPAIRS <br />SHALL MATCH EXISTING FINISHES. <br />17.0 COMMUNICATIONS <br />17.1 TENANT IS IN CHARGE FOR ANY COMMUNICATIONS SYSTEMS. <br />17.2 ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL, IF REQUIRED, TELEPHONE TERMINAL BOARD, 24"x24" <br />PLYWOOD 3/4" THICK (OR AS DETAILED IN PLANS), AND CONDUIT AS INDICATED ON DRAWINGS. <br />17.3 ALL WIRING, INCLUDING INSTALLATION AND CONNECTION TO EQUIPMENT SHALL BE PERFORMED BY A SPECIALIZED <br />CONTRACTOR, IN CHARGE OF THE TENANT. <br />18.0 FIRE ALARMS <br />18A EXISTING FIRE ALARM TO BE KEPT TENANT'S FIRE ALARM CONTRACTOR TO RELOCATE IF REQUIRED ANY <br />EQUIPMENT AT NO COST. <br />18.2 ALL REQUIRED WORK RELATED TO LIFE SAFETY SYSTEMS SHALL BE DONE AT NO EXTRA COST. RETAIN THE SYSTEM <br />MANUFACTURER'S FORCES TO PERFORM FINAL CONNECTIONS, MODIFICATIONS AND PROVISION OF NEW INTERFACING <br />DEVICES IN THE SYSTEM PANELS, ETC. <br />18.3 ENSURE FULL COMPATIBILITY OF ALL NEW DEVICES WITH EXISTING LIFE SAFETY SYSTEMS. <br />18.4 TENANT'S FIRE ALARIA CONTRACTOR SHALL HAVE SYSTEM MANUFACTURER TEST AND CERTIFY LIFE SAFETY <br />SYSTEMS FOR PROPER OPERATION AT COMPLETION OF WORK. <br />19.0 COLOR CODE <br />120/203V <br />120/240V HIGH LEG 3P AN 277/430V <br />PHASE A <br />BLACK <br />BLACK BROWN <br />PHASE B <br />RED <br />ORANGE ORANGE Y <br />PHASE C <br />BLUE <br />BLUE W YELLOW <br />NEUTRAL <br />WHITE <br />WHITE GREY <br />GROUND <br />GREEN~ <br />GREEN GREEN <br />20.0 SPECIAL_ NOTES <br />20.1 ELECTRICAL CONTRACTOR TO PROVIDE UNDERGROUND CONDUIT TO EC PROVIDED SURFACE MOUNTED J-BOXES, <br />OWNER FURNISHED RECESSED FLOOR BOXES AND OWNER FURNISHED POKE-THRU BOXES AS INDICATED AND PROVIDE <br />APPROVED FLEX CONNECTION ASSEMBLY. LEAVE FLEX CONNECTION ASSEMBLY COILED AND TAPED AS REQ'D UNTIL <br />FIXTURE INSTALLATION. AFTER FIXTURE INSTALLATION EC TO INSTALL POWER RECEPTACLES IN PRE -INSTALLED BLANK <br />BOXES INSIDE FIXTURE, PROVIDE POWER CIRCUIT FROM PANEL TO RECEPTACLES AND CONNECTION POWER SOURCE. EC <br />TO PROVIDE PULL STRING FROM TELEPHONE BOARD TO ALL FIXTURE DESIGNATIONS FOR CAT5E DATA CABLING AND RJ45 <br />JACKS BY OWNER'S VENDOR. SEE WIRING DETAILS ON SHEETS E501 AND E511 FOR ADDITIONAL INFORMATION. <br />20.2 ON ALL OUTLETS LOCATED IN POS COUNTERS, ETC..., ELECTRICAL TRADE SHALL ATTACH ALL CONDUITS TO THE <br />FLOOR WITH APPROPRIATE CONNECTORS. GC MUST OBTAIN WRITTEN APPROVAL FROM THE LANDLORD PRIOR TO ANY <br />TRENCHING OR CORE DRILLING. <br />20.3 RECEPTACLES, OUTLETS, ETC..., LOCATED AT THE CASH COUNTERS SHALL BE INSTALLED IN COMMON BOXES, USE 1 <br />GANG, 2 GANG, 3 GANG OR 4 GANG, ETC..., BOXES C[W SEPARATIONS AS PER CODE, AS REQUIRED. BOXES SUPPLIED, <br />INSTALLED AND CONNECTED BY THE ELECTRICAL CONTRACTOR. <br />21.0 DEMOLITION <br />21.1 REMOVE AND TRANSPORT OUT OF THE CONSTRUCTION SITE ALL EQUIPMENT MADE OBSOLETE CONSECUTIVE TO <br />THE WORK, INCLUDING WIRING, CONDUITS, BOXES, OUTLETS, SWITCHES, LIGHTING FIXTURES, DISTRIBUTION EQUIPMENT, <br />SUPERVISORY AND COMMUNICATION EQUIPMENT. ALL ACCESSORIES BEING PART OF THE ELECTRICAL INSTALLATION. <br />21.2 REMOVE THE WIRING AND THE CONDUIT UP TO THE LAST PANEL OR BOX KEPT IN THE NETWORK. <br />21.3 PUT BACK IN SERVICE ALL FEEDERS, CONTROL OR COMMUNICATION CABLES WHEN THE CONTINUITY OF THOSE <br />SERVICES IS INTERRUPTED BY THE WORK. <br />22.0 SPECIFICATIONS <br />22.1 DISCONNECT AS PER CUTLER -HAMMER <br />22.2 FUSES AS PER GOULD <br />MODEL <br />FUSE <br />INSTALLATION <br />HD <br />WITH <br />INTERIOR <br />LID m <br />WITHOUT <br />INTERIOR <br />RD <br />UVITH <br />EXTERIOR <br />R® _- <br />--WITHOUT <br />EXTERIOR <br />GAGE <br />MODEL <br />SPARE CITY. <br />0 500A <br />AJT <br />M% MINIMUM 6 <br />22.3 SPUTTER BOXES AND TROUGHS, AS PER BEL, 14 GA STEEL WITH HINGED COVER CLOSED WITH SCREWS, TINNED <br />COPPER BUS BARS, COMPLETE WITH SOLDERLESS TERMINALS. BARS SUPPORTED BY ISOLATORS. <br />22.4 TRANSFORMERS AS PER DELTA, DT (TRIPLE PHASE). <br />22.5 PANELS CAA/ DOORS AND LOCKS, AS PER CUTLER -HAMMER <br />USAGE <br />VOLTAGE <br />MODEL <br />LIGHTING <br />120/20 3P3PH <br />PRL 1 <br />BREAKERS WITH 10,000 A SYMMETRICAL INTERRUPTING <br />CAPACITY, UNLESS OTHERWISE NOTED <br />22.6 OUTLETS AS PER LEVI I ON, MODEL NO, 5262, WHITE. <br />22.7 SWITCH <br />TYPE _ <br />- <br />UNIPOLAR <br />_MODEL <br />5401/001 <br />BIPOLAR <br />54502/001 <br />THREE WAY <br />54503/001 <br />FOUR WAY <br />54504/001 <br />2 <br />1 <br />SYMBOLSLEGEND <br />NOTE: NOT ALL SYMBOLS LISTED BELOW ARE SHOWN ON PLANS <br />SWITCHING <br />POWER <br />DISTRIBUTION DEVICES <br />GENERA. WIRING <br />SWITCH BANK <br />PANELBOARD SURFACE MOUNTED MAXIMUM <br />HOMERUN - CONDUIT SYSTEM TO <br />72" TO TOP OF OVERCURRENT PROTECTION <br />PANEL AS NOTED ON DRAWINGS <br />SWITCH _ <br />ET <br />TRANSFORMER a <br />CONDUIT SYSTEM UNDER FLOOR <br />DIMMER SWITCH <br />DISCONNECT SWITCH <br />CONDUIT UP <br />OS <br />OCCUPANCY SENSOR - CEILING MOUNTED <br />'M `) <br />METER <br />TELEPHONE TERMINAL BOARD <br />ti <br />SEE DETAIL AIL ON SHEET E4 <br />® <br />OCCUPANCY SENSOR - WALL MOUNTED <br />DUPLEX RECEPTACLE - 20A <br />JUNCTION BOX <br />18" AFF UNO <br />PC <br />PHOTOCELL - CEILING MOUNTED <br />QUADPLEX RECEPTACLE - 20A <br />RECESSED FLOOR BOX <br />18" AFF UNO <br />LCP <br />LCP - LIGHTING CONTROL PANEL <br />GFI <br />RECEPTACLE <br />ABBREVIATIONS <br />WITH GROUND FAULT INTERRUPTER <br />INVER <br />MINI -INVERTER <br />WP <br />WEATHERPROOF RECEPTACLE <br />BOH <br />BACK OF HOUSE <br />1$ AFF UNO <br />CB <br />CIRCUIT BREAKER <br />Tvss <br />TRANSIENT VOL RAGE SURGE SUPPRESSOR <br />SHOW WINDOW RECEPTACLE <br />DL <br />DAYLIGHT 4 <br />EC <br />ELECTRICAL CONTRACTOR <br />iAGS <br />JUNCTION BOX <br />EM <br />EMERGENCY <br />GC <br />GENERAL CONTRACTOR <br />�A <br />DETAIL DESIGNATION: <br />� f COMMUNICATION <br />1G - <br />ISOLATED GROUND <br />AA - DETAIL NUMBER <br />JB <br />JUNCTION BOX (J-BOX) <br />BB <br />BB - SHEET NUMBER <br />TELEPHONE / DATA - RJ45 JACK W/ CAT5e <br />JHA <br />JURISDICTION HAVING AUTHORITY <br />SHEET NOTE <br />XX <br />WIRES. CONDUIT WITH PULLWIRE TO ABOVE <br />LL <br />LANDLORD <br />X <br />ACCESSIBLE CEILING, CABLE IS BY OWNER. <br />MLO <br />MAIN LUG ONLY <br />SECTION DESIGNATION: <br />xx <br />OVERHEAD AP CABLING <br />MCB <br />MAIN CIRCUIT BREAKER <br />AA - DETAIL NUMBER <br />OR <br />ORANGE <br />BB <br />BB -SHEET NUMBER <br />SW <br />SHOW WINDOW <br />SECURITY / COMMUNICATION <br />TGC <br />TENANT GENERAL CONTRACTOR <br />KP <br />ROUGH -IN FOR ADT KEY PAD @ 48"A.F.F. <br />WH <br />WHITE <br />NEC <br />NATIONAL ELECTRIC CODE <br />T <br />THERMOSTAT <br />A. FIELD VERIFY ALL CONDITIONS. <br />B. DESIGN DRAWINGS ARE SCHEMATIC. ONCE ONSITE GENERAL CONTRACTOR IS TO INSPECT EXISTING FIELD CONDITIONS. RFI SHALL BE SUBMITTED FOR ALL LABOR AND <br />MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. <br />C. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER ONCE ONSITE FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN INTENT PRIOR TO <br />COMMENCEMENT OF WORK. <br />D. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED <br />IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER <br />OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. <br />E, RFI SHALL BE SUBMITTED FOR ANY UNFORESEEN CONDITIONS THAT MAY EFFECT THE CONTRACTOR'S SCOPE OF WORK. MINOR VARIATIONS REQUIRED FOR ACCOMPLISHING <br />THE INTENT OF THIS DESIGN SHALL BE INCLUDED IN THE RFI. <br />F. PROVIDE ALL REQUIRED PERMITS AND INSPECTIONS. CONTRACTOR'S INSTALLATION SHALL CONFORM TO ALL LOCAL CODE REQUIREMENTS. <br />G. VERIFY EXACT PLACEMENT OF ALL DEVICES SHOWN ON THE DOCUMENTS WITH ARCHITECTURAL, MECHANICAL AND PLUMBING DRAWINGS PRIOR TO FINAL PLACEMENT, <br />H. BECOME FAMILIAR WITH REQUIRED DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL DEMOLITION AS <br />REQUIRED FOR INSTALLATION OF NEW WORK. <br />1. COORDINATE INSTALLATION OF ELECTRICAL WORK ABOVE THE CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION OF PLUMBING AND <br />MECHANICAL, CONDUIT RUNS SHALL BE RUN THROUGH TRUSSES WHERE POSSIBLE. <br />J. COORDINATE EXACT LOCATION OF DEVICES SERVING CASEWORK WITH FIXTURE CONTRACTOR. <br />K. COORDINATE ALL LOW VOLTAGE CONDUIT AND ROUGH -IN REQUIREMENTS WITH LOW VOLTAGE CONTRACTORS. <br />L. SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES, TRANSFORMERS AND CONTACTORS SHALL BE "LISTED" AND "IDENTIFIED" AS RATED FOR A MINIMUM OF 75°C <br />CONDUCTOR TERMINATION. <br />M. INCLUDE A COPPER EQUIPMENT GROUND CONDUCTOR IN ALL RACEWAYS. SIZE RACEWAYS AS NECESSARY TO COMPLY WITH NEC. <br />N. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH A PULL WIRE. <br />O. ALL 20A BRANCH CIRCUITS BETWEEN 100' AND 150' IN LENGTH, #10 AWG COPPER WIRE SHALL BE USED. FOR ALL 20A BRANCH CIRCUITS OVER 150' IN LENGTH, #8 AWG COPPER <br />WIRE SHALL BE USED. <br />P. ALL 20A BRANCH CIRCUITS LESS THAN 100' iN LENGTH, SHALL BE #12 COPPER CONDUCTORS, #12 GND., 3/4" UNLESS NOTED OTHERWISE. TYPE MC CABLE MAY BE USED FOR <br />BRANCH CIRCUITS ABOVE CEILINGS AND FOR FINAL FIXTURE CONNECTIONS. DO NOT USE TYPE MC EXPOSED UNLESS APPROVED BY LOCAL INSPECTOR AND JHA. ELECTRICAL <br />CONTRACTOR TO VERIFY. <br />Q. CIRCUITING INDICATED ON PLAN IS DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL BE "THRU-WIRING" WHERE/WHEN POSSIBLE. MULTI -CONNECTIONS TO A SINGLE LIGHT <br />FIXTURE FOR FIELD CONDITIONS OR VOLTAGE DROP FACTORS MAY BE REQUIRED (FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU-WIRING"), AND RELATED <br />COSTS SHALL BE INCLUDED IN BID. <br />R. MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. <br />S. WHERE DRYWALL CEILINGS ARE USED, CONTRACTOR SHALL ARRANGE CIRCUITING SO THAT JUNCTION/BOXES ACCESS PANELS ARE NOT INSTALLED IN THESE DRYWALL <br />CEILING AREAS. (THE USE OF JUNCTION BOXES IN THESE DRYWALL CEILINGS IS NOT PERMITTED, ARRANGE CIRCUITS TO AVOID THIS SITUATION). FIELD COORDINATE WITH <br />TENANT'S CONSTRUCTION MANAGER PRIOR TO ROUGH -IN TO AVOID CONFLICTS. JUNCTION BOXES MAY BE PLACED ABOVE LAY -IN CEILINGS. <br />T. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR, PRIOR TO ORDERING RELATED ELECTRICAL <br />EQUIPMENT. <br />U. PLACEMENT OF ALL RECEPTACLES SHALL BE INTENTIONAL (I.E. CENTERED ON COLUMNS OR WALL FEATURES, OR TIGHT TO CORNER). IF RECEPTACLE IS NOT SHOWN IN A <br />DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENANT'S CONSTRUCTION MANAGER. PRIOR TO ROUGH -IN. <br />V. PROVIDE ALL NECESSARY COMPONENTS TO MAKE A COMPLETE WORKING SYSTEM. VERIFY ROW LENGTHS, FEED POINT AND MOUNTING REQUIREMENTS S PRIOR TO ORDERING <br />W. TAKE ADEQUATE CARE TO CORRECTLY LOCATE ALL ELECTRICAL S T UBOUTS, FLOOR BOXES, J-BOXES, TRACK, ETC. PRECISE LOCATIONS OF FLOOR OUTLETS AND J-BOXES IS <br />VERY IMPORTANT. <br />X. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL <br />EQUIPMENT. NEC 110.34(t). <br />Y. FUSES SHALL BE PROVIDED WITH REJECTION TYPE FUSE HOLDERS. NEC 240.60B. <br />Z. PROVIDE LOCK -ON DEVICE FOR CIRCUITS SUPPLYING EMERGENCY UNIT EQUIPMENT, NEC 700.18. <br />AA. ATTAIN EXISTING BUILDING LOAD INFORMATION AND VERIFY AMPACITY AND DEMAND FOR BUILDING TO ENSURE THAT ALL LOADS (EXISTING AND NEW) DO NOT EXCEED THE <br />AMPACITY OF THE SERVICE FEEDER(S) OR RATING OF THE SERVICE, PER NEC 220.40, <br />AB. ALL DEDICATED RECEPTACLES SHALL BE RATED TO NOT LESS THAN THE RATING OF THE BRANCH CIRCUIT SERVING THE RECEPTACLE. <br />AC, SUPPORT VERTICAL CABLE RUNS PER NEC 300.19. <br />F <br />I 12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />vwvw.t-moblle.com <br />i <br />COPYRIGHT NOTICE: <br />7 THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT <br />jj TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. <br />102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003, THE <br />PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, <br />ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE <br />DESIGN, UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE <br />DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF <br />CONSTRUCTION, BUILDING SEIZURE, AND/OR MONETARY LIABILITY. <br />ARCHITECT: <br />20:16 BjrpFL€ F:'1s"9CS <br />kph ,""3+. x 3 [$#� <br />Milancii'ufifburrg,,�411,004.5342 <br />5.. . vff'.: %"e U."�'sfFt R, c +`�:� <br />��`i'C.6yli�..l 7L,�AF <br />07/02/2021 <br />CONSULTING ENGINEER: <br />DATE: 07/02/2021 <br />SCALE: AS NOTED <br />DRAWN BY: JVH <br />SAP NUMBER: <br />CORPORATE REMODEL CD <br />LDC <br />SHEET TITLE: <br />I <br />SHEET NUMBER. <br />E701 <br />