<br />NOTES
<br />EXISTING STOREFRONT SYSTEM, GLAZING, AND DOOR(S) TO REMAIN.
<br />EXISTING EXTERIOR WALL AND/OFF CONSTRUCTION TO REMAIN. PATCH AND REPAIR AS REQUIRED.
<br />- AS INDICATED IN THESE PLANS.
<br />PREPARE EXISTING CONCRETE FLOOR SURFACE FOR INSTALLATION OF NEW FLOORING MATERIALS �,
<br />SEE SPECIFICATIONS FOR ADDITIONAL FLOOR PREPARATION NOTES.
<br />4
<br />EXISTING MOP SINK TO BE REMOVED.
<br />5
<br />EXISTING DASHED FLOORIWALL FIXTURES AND SIGNAGE TO BE REMOVED IN THEIR ENTIRETY.
<br />6
<br />LEASE LINE.
<br />7
<br />EXISTING INTERIOR DOOR TO BE REMOVED IN ITS ENTIRETY.
<br />8
<br />EXISTING INTERIOR WALL TO BE REMOVED IN ITS ENTIRETY.
<br />9
<br />EXISTING TOILET ROOM, PLUMBING FIXTURES AND FLOORING TO BE REMOVED IN THEIR ENTIRETY.
<br />10
<br />EXISTING THRESHOLD TO REMAIN. REPLACE IF IT EXCEEDS 1/2" IN HEIGHT.
<br />1 1
<br />EXISTING FIRE EXTINGUISHER TO BE REMOVED.
<br />12
<br />EXISTING ELECTRICAL PANEL(S) TO REMAIN.
<br />13
<br />EXISTING PARTITION WALL TO REMAIN. PATCH AND REPAIR AS NEEDED TO RECEIVE NEW FINISHES AS SPECIFIED IN THESE PLANS.
<br />14
<br />EXISTING DEMISING WALL TO REMAIN, PATCH AND REPAIR AS REQUIRED.
<br />PORTION OF EXISTING INTERIOR WALL TO BE REMOVED UP TO 7 0® A.F.F. FOR A NEW INVENTORY AND TOILET OPENING AS INDICATED IN
<br />15
<br />THESE PLANS.
<br />16
<br />EXISTING STRUCTURAL COLUMN TO REMAIN. REMOVE ALL FINISHES AND PREPARE FOR NEW FINISHES AS INDICATED IN THESE PLANS,
<br />17
<br />EXISTING FLOOR MOUNTED IT/DATA RACK TO BE REMOVED.
<br />18
<br />EXISTING DRINKING FOUNTAIN TO BE REMOVED.
<br />19
<br />EXISTING WALK OFF MAT TO BE REMOVED.
<br />1. GENERAL CONTRACTOR AND/OR SUBCONTRACTORS
<br />SHALL REVIEW THE EXISTING FACILITY TO DETERMINE
<br />THE EXTENT OF DEMOLITION REQUIRED TO INSTALL THE
<br />NEW WORK. A WRITTEN OUTLINE OF ALL REQUIRED
<br />DEMOLITION SHALL BE SUBMITTED TO T-MOBILE
<br />DESCRIBING THE FOLLOWING (BUT NOT LIMITED TO):
<br />1A CONDITION OF EXISTING POWER PANELS AND
<br />TRANSFORMERS; IBILITY FOR RELOCATION AND
<br />FEASIBILITY
<br />REFURBISHING, OR NEED FOR REPLACEMENT DUE TO
<br />AGE OR EXISTING CONDITION.
<br />1.2 CONDITION OF EXISTING GYPSUM BOARD ON EXISTING
<br />DEMISING WALLS AND RECOMMENDATION OR WHETHER
<br />TO REMOVE EXISTING OR REUSE TO BE DETERMINED IN
<br />FIELD.
<br />1.3 SUMMARIZE RECOMMENDATIONS FOR REUSE OF
<br />EXISTING MATERIALS, EQUIPMENT, AND ACCESSORIES.
<br />ONCE REFURBISHED TO A LIKE -NEW CONDITION,
<br />ITEMIZE THE CREDIT TO THE CONTRACT.
<br />1.4 TENANT G.C. SHALL NOTIFY THE ARCHITECT OF ANY UN -
<br />NOTED EXISTING CONDITION WHICH CONFLICTS WITH
<br />THE PROJECT REQUIREMENTS AND MAY REQUIRE
<br />MODIFICATION, RELOCATION, OR REMOVAL TO COMPLETE
<br />THE PROJECT WITHIN 24 HOURS SO THAT THE
<br />NECESSARY DRAWING REVISIONS MAYBE
<br />INCORPORATED INTO THE PROJECT REQUIREMENTS.
<br />1.5 IN ADDITION TO THE ABOVE, REFER TO GENERAL
<br />DEMOLITION NOTES INDICATED IN SPECIFICATION
<br />DIVISION 2- EXISTING CONDITIONS.
<br />1.6 CONDITION OF EXISTING MECHANICAL SYSTEM;
<br />FEASIBILITY OF REUSING, RELOCATION, OR
<br />REFURBISHING EXISTING EQUIPMENT AND
<br />DUCTWORK; AND RECOMMENDATION OF
<br />REPLACEMENT, IF NECESSARY, PRIOR TO BID.
<br />SEE MECHANICAL DRAWINGS FOR SCOPE OF
<br />MECHANICAL WORK.
<br />0 1' 21 4'
<br />1.
<br />CHECK MECHANICAL AND ELECTRICAL DRAWINGS PRIOR RO DEMOLITION
<br />14.
<br />G.C. SHALL CONSTRUCT A BARRICADE WALL AS REQUIRED. G.C. SHALL
<br />WITH REGARD TO UTILIZING ANY EXISTING WIRING, LINES, COMPONENTS,
<br />COORDINATE REQUIREMENTS WITH MALL PROPERTY MANAGEMENT.
<br />ETC.
<br />15.
<br />BARRICADE GRAPHICS SHALL BE PROVIDED BY MALL UNLESS OTHERWISE
<br />2.
<br />PROVIDE TRASH CONTAINER AS REQUIRED AT LOCATION TO SUIT
<br />REQUESTED. G.C. SHALL ENGAGE T-MOBILE'S SIGN VENDOR FOR BARRICADE
<br />LANDLORD. REMOVE DEBRIS DAILY AND HAUL FROM THE SITE AT TIME TO
<br />GRAPHICS AS REQUIRED.
<br />SUIT LANDLORD.
<br />16.
<br />FIRE SPRINKLER SYSTEM TO REMAIN - G.C. TO RE -WORK/ MODIFY SYSTEM AS
<br />3.
<br />NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCPRENANCIES OR
<br />REQUIRED FOR NEWCONSTRUCTION. VERIFY IN FIELD.
<br />UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS.
<br />17.
<br />WHERE REQUIRED BY THE LOCAL JURISDICTION, G.C. SHALL PREPARE A
<br />4.
<br />ALL REMOVED MATERIAL AND DEBRIS, NOT OTHERWISE DESIGNATED,
<br />"RECYCLING PLAN" TO DIVERT DEBRIS FOR RECYCLING. G.C. SHALL KEEP
<br />BECOMES THE PROPERTY OF THE CONTRACTOR, WHO SHALL REMOVE IT
<br />RECORDS OF DIVERTED MATERIAL AS REQUIRED. G.0 TO VERIFY
<br />FROM THE SITE.
<br />REQUIREMENTS WITH JURISDICTION AND TO MALL OPERATIONS/ LANDLORD
<br />5.
<br />G.C. SHALL NOT DEMOLISH AND LOAD BEARING WALLS OR CONSTRUCTION
<br />WHERE APLLICABLE.
<br />THAT WILL COMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING
<br />18.
<br />REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS, AND DOOR FRAMES
<br />SPACE. G.G. TO NOTIFY THE ARCHITECT IMMEDIATELY OF ANY STRUCTURAL
<br />SCHEDULED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC. THAT
<br />CONCERNS DURING CONSTRUCTION.
<br />IS ATTACHED TO PARTITIONS SCHEDULED FOR DEMOLITION.
<br />6.
<br />EXISTING EQUIPMENT NOT BEING USED MUST BE COMPLETELY
<br />19,
<br />REMOVE EXISTING HVAC CEILING DIFFUSERS AND RETURN GRILLES AS
<br />REMOVED/DISPOSED OF PROPERLY, NOTHING CAN BE ABANDONED ABOVE
<br />SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION! DEMOLITION
<br />THE CEILING.
<br />AND NEW CONSTRUCTION. MODIFY EXISTING DUCTWORK AS REQUIRED BY
<br />7.
<br />REMOVE EXISTING ACCOUSTICAL CEILING GRID AND TILES, LIGHT FIXTURES,
<br />NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF SUPPLY
<br />AND GYPSUM WALL BOARD SOFFITS AS SCHEDULED FOR DEMOLITION AND
<br />AND RETURN DUCTS AT NEAREST SOURCE ABOVE CEILNG.
<br />AS REQUIRED BY PARTITION DEMOLTION AND NEW CONSTRUCTION WORK.
<br />20.
<br />REMOVE ALL EXISTING PLUMBING FIXTURES, FITTINGS, AND PIPING AS
<br />MAINTAIN EXISTING CEILING WIRE HANGERS FOR FUTURE USE.
<br />SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION
<br />S.
<br />REMOVE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA
<br />AND NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF AT
<br />JACKS AND THERMOSTATS IN PARTITIONS SCHEDULED FOR DEMOLITION.
<br />WET STACK.
<br />MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT
<br />21.
<br />REMOVAL/ RELOCATION OF ALL CEILING EQUIPMENT (TYCO, FIRE ALARM,
<br />REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE
<br />SPRINKLER, SHOPPER TRAK, ETC.) MUST BE PERFORMED BY THE REQUIRED
<br />ABOVE CEILING.
<br />VENDORS. T-MOBILE'S VENDOR TO RELOCATE SECURITY CAMERAS AS NEEDED
<br />9.
<br />REMOVE EXISTING FLOOR FINISHES SCHEDULED FOR REMOVAL AND AS
<br />PER NEW FIXTURE LAYOUT,
<br />REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. PREPARE
<br />22.
<br />G.C. TO CONFIRM FLOOR SLAB IS SMOOTH AND LEVEL AND NOTIFY
<br />EXISTING FLOOR SURFACE PER MANUFACTURER FOR INSTALLATION OF
<br />CONSTRUCTION PM OF ANY DISCREPANCIES.
<br />NEW FLOORING MATERIAL INDICATED IN THESE PLANS. G.C. MAY NEED TO
<br />23.
<br />MAINTAIN EXISTING EXITS, EMERGENCY LIGHTING, AND ILLUMINATION MEANS
<br />PERFORM A MOISTURE TEST PRIOR TO ANY DEMOLITION OR NEW FLOORING
<br />OF EGRESS DURING DEMOLITION AND CONSTRUCTION AS REQUIRED BY JHA
<br />INSTALLATION. NEWLY REPLACED OR LIKE -NEW FINISHES MAY REMAIN AT
<br />AND ALL GOVERNING CODES.
<br />THE DISCRETION OF THE CONSTRUCTION PM. G.C. TO VERIFY PRIOR TO
<br />24.
<br />SAW -CUTTING SHOWN ON PLANS IS AN INDICATION OF THE INTENDED WORK
<br />REMOVAL. PROTECT ALL NEW FLOOR FINISHES UNTIL FINAL CLEANING.
<br />FOR BIDDING AND COORDINATION PUPOSES ONLY. IT IS NOT INTENDED FOR BE
<br />10.
<br />REMOVE ALL CONSTRUCTION DEBRIS FROM AREA. REPAIR ALL ADJACENT
<br />AS SPECIFICATION OR METHOD.
<br />DAMAGED SURFACES, AS NECESSARY. PREPARE ALL DAMAGED SURFACES
<br />25.
<br />WHEN EXISTING MECHANICAL SYSTEM IS TO REMAIN, G.C. TO CLEAN
<br />FOR FINISHES AS SCHEDULED OR REFINISH TO MATCH EXISTING.
<br />DUCTWORK, DIFFUSERS, AND REPLACE HVAC AIR FILTERS AFTER
<br />11.
<br />PROVIDE A SMOOTH, NEAT, AND CONTIUOUS APPEARANCE WHERE
<br />CONSTRUCTION AND CLEANUP IS COMPLETE PRIOR TO TURNING PROJECT
<br />DEMOLITION WORK MEETS ADJACENT EXISTING WORK. REMOVED EXISTING
<br />OVER TO T-MOBILE.
<br />FINISHES AS REQUIRED TO PROVIDE BEAT, STRAIGHT SEAMS AND
<br />26.
<br />DURING CONSTRUCTION, THE G.C. IS TO PROVIDE A PORTABLE FIRE
<br />TRANSITIONS BETWEEN EXISTING AND MATCHING NIEl14 FINISHES.
<br />EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A WITHiNG A 75 FOOR
<br />12.
<br />IN ACCORDANCE WITH LOCAL CODES, REPLACE ALL FIRE SUPPRESSION
<br />TRAVEL DISTANCE TO ALL PORTIONS OF THE SPACE.
<br />AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK. MAINTAIN
<br />INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM SYSTEMS. VERIFY IN
<br />FIELD.
<br />13.
<br />IN THE CASE THAT THE EXISTING CABLE LINE, PHONE LINE AND BLOCK, T-1
<br />LINE AND DATA CABLING PRESENT, G.C. SHALL SALVAGE AND REWORK TO
<br />FACILITATE NEW INSTALLATION.
<br />12920 SE 38th STREET
<br />BELLEVUE, WA 98006
<br />www.T-N4obilE).com
<br />COPYRIGHT NOTICE
<br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO
<br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF
<br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION
<br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND
<br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH
<br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS
<br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR
<br />MONETARY LIABILITY.
<br />ARCHITECT
<br />2056 Byers Roil
<br />-,llj,l➢j bLlrq,Ohio 45",t2
<br />S444.8'04.7700
<br />nl 7
<br />®ga-^^
<br />"ET
<br />STATE OF WASH6NSTo1N
<br />0 /0 / � -
<br />CONSULTING ENGINEER:
<br />Lu
<br />Lu
<br />Lo
<br />Lum
<br />UJ
<br />Lu
<br />ui
<br />i
<br />i
<br />DATE: July 02, 2021
<br />SCALE: AS NOTED
<br />DRAWN BY: PT
<br />SAP NUMBER:
<br />4 3 2 1
<br />
|