Laserfiche WebLink
1 1 2 <br />4 <br />5 <br />tC <br />iC <br />IC <br />A <br />EXISTING BUILDING CODE INFORMATION <br />Cont. <br />t <br />Existing occupancy M <br />Propose ocepansy <br />A-3 <br />Year building was constructed 1984 <br />Number of stones 1 Height in,feet 23.5 (AVG.) <br />Type of construction III-g <br />Area per tier <br />46,781 MAIN FLR.)+ 2,147(MEZZ} = 48,928 <br />Percentage of open perimeter increase 78 <br />Completely suppressed: <br />Yes <br />No <br />Corridor wall rating N/A <br />Type; <br />Co artmentation: <br />Yes <br />X <br />Required door closers: <br />Yes N/A <br />No <br />Fire -resistance rating of vertical opening enclosures N/A <br />Type of HVAC system DUCTED, ROOFTOP serving number of flocs 1 <br />Automatic fire detection-. <br />e <br />No <br />Type and location CODE COMPLIANT <br />Fire alarm systern. <br />Xs <br />No <br />Type CURRENT CODE COMPLIANT <br />Smoke control: <br />Yes <br />X <br />Type <br />Adequate exit routes: <br />YX <br />No <br />Bead ends_ <br />Yes X <br />No <br />Maximum e)dt access travel distance 250' <br />Elevator centrals: N/A <br />Yes <br />No <br />Means of egress emergency lighting: Yes X No <br />Mixed occupancies: <br />Yes <br />No X <br />Standpipes <br />Yes <br />X <br />Patient ability for self-preservation N/A <br />Incidental use <br />Y <br />X <br />Patient concentration N/A <br />Smoke compartmentation less than 22,50,D s . feet <br />Yes <br />No <br />X <br />Atten. dant-tb-patient ratio N/A <br />SAFETY PARAMETERS <br />FIRE SAFETY (FS) <br />MEANS OF EGRESS (ME) <br />GENERAL SAFETY (GS) <br />1401.6.1 Building Height <br />2.0 <br />2.0 <br />2.0 <br />14 1.6.2 Bulkillng Area <br />-2.5 <br />-2.5 <br />-2.5 <br />1401.5.3 C€ mp rtri ntation <br />0.0 <br />0.0 <br />0.0 <br />1401.6.4 Tenant .and Dwelling Unit Separations <br />0.0 <br />0.0 <br />0.0 <br />1401.5:.5 Comdor Falls <br />0.0 <br />0.0 <br />0.0 <br />1401_6-6 Vertical Openings <br />0.0 <br />0.0 <br />0.0 <br />1401 6.7 HVAC Systems <br />5.0 <br />5.0 <br />5.0 <br />14 1.6.8 Autornatc Fire Detection <br />6.0 <br />6.0 <br />6.0 <br />141...9 Fire Alarm System <br />5.0 <br />5.0 <br />5.0 <br />1401.6.10 Smoke contfoll <br />0.0 <br />0.0 <br />1401.5.11 Means of Egress <br />10.0 <br />10.0 <br />1401.s6.12 lead ends <br />� � � � <br />-2.0 <br />-2.0 <br />1401.& 13 M "mum Exit Access Travel Distance <br />� � *2 <br />3.4 <br />3.4 <br />1401.& 14 Elevator Control <br />0.0 <br />0.0 <br />0.0 <br />141..15 Means of Egress Emergency Lighting <br />4.0 <br />4.0 <br />1401..5.16 Mixed Occupancies <br />0.0 <br />0.0 <br />1401..17 Autornafic Sprinklers <br />4,0 <br />- = 2,0 <br />4.0 <br />1401. .18 Standpipes <br />6.0 <br />6.0 <br />6.0 <br />1401..6.19 Incidental Use <br />0.0 <br />0.0 <br />0.0 <br />1401.5..20 Sm-ke compartmentation <br />0.0 <br />0.0 <br />0.0 <br />1401...21.1 Patient ability for self-presetvation <br />� �'� � <br />0.0 <br />0.0 <br />14 1.6.21.2 Patient concentration <br />0.0 <br />0.0 <br />1401.6.21. Attendant -to -patient Ratio <br />� � * * <br />0.0 <br />0.0 <br />Building scor f value <br />25.5 <br />38.9 <br />40.9 <br />Notes: <br />Add Fire alarm control station to Fire Alarm System <br />Add Standpipe <br />01!11' <br />= Fire Safety. <br />- Mandatory Fire Ste. <br />i! <br />E _ Means of Egress. IN <br />ME_' WarWatM Meads of Egress. <br />_ Senegal safety. t, <br />GS = Mandatory Meares of Sa iy. <br />OCCUPANCY: <br />ASSEMBLY UNCONCENTRATED: <br />50 S.F/ OCCUPANT AT EXERCISE ROOMS PER IBC TABLE 1004.1.2 <br />ACTUAL OCCUPANCY: <br />600 GUESTS/CUSTOMERS, 40 STAFF, TOTAL OCCUPANCY 640 <br />* REDUCED OCCUPANT LOAD BASED UPON ACTUAL OCCUPANCY, PER IBC <br />1004.1.2 EXCEPTION. ACCESS TO FACILITY WILL BE MANAGED AT TWO CHECK -IN <br />COUNTERS. OCCUPANCY LIMIT SIGNS WILL BE POSTED AT BOTH ENTRY DOORS <br />PER IBC 1004.3. IN ADDITION, SECURITY STAFF WILL BE PRESENT IF OCCUPANCY <br />EXCEEDS 500. <br />PLUMBING FIXTURE COUNT <br />PER IBC WASH. ST. AMENDMENTS, TABLE 2902.1: 320 MALE, 320 FEMALE <br />REQUIRED FIXTURE COUNTS: <br />LAVATORIES: <br />MALE AND FEMALE 320 OCCUPANTS X 1/200 = 1.6 REQ'D <br />WC'S: <br />MALE 320 OCCUPANTS X 1/125 = 2.6 REQ'D <br />FEMALE 320 OCCUPANTS X 1165 = 4.9 REQ'D <br />PROPOSED FIXTURES: <br />LAVATORIES: <br />MALE AND FEMALE 4 PROVIDED + 0.5 UNISEX = 4.5 > 1.6 REQ'D <br />WC'S: <br />MALE 3 PROVIDED +3 URINALS + 0.5 UNISEX = 6.5 > 2.6 REQ'D <br />FEMALE 6 PROVIDED >+ 0.5 UNISEX = 6.5 > 4.9 REQ'D <br />EXISTING BUILDING CODE INFORMATION <br />ALTERATIONS PROPOSED IN THIS PROJECT SHALL MEET THE PERFORMANCE <br />COMPLIANCE MEASURES DESCRIBED IN CHAPTER 14 OF THE INTERNATIONAL <br />EXISTING BUILDING CODE. <br />IN GENERAL, EXISTING MATERIALS AND SYSTEMS SHALL BE ALLOWED TO <br />REMAIN IN PLACE. ALTERATIONS ( NEW SYSTEMS AND MATERIALS) SHALL MEET <br />REQUIREMENTS OF IBC, AND OTHER APPLICABLE CODES. <br />PER IEBC SECTION 407.4 CHANGE IN USE TO HIGHER RISK CATEGORY USE SHALL <br />REQUIRE SEISMIC EVALUATION AS DESCRIBED IN IEBC CHAPTER 3, <br />ALTERATIONS SHALL MEET ACCESSIBILITY REQUIREMENTS OF IEBC SECTION <br />410, AND IBC CHAPTER 11, <br />BUILDING SAFETY EVALUATION PER IEBC 1401.6: <br />GENERAL SAFETY, FIRE SAFETY, AND MEANS OF EGRESS <br />BUILDING HEIGHT AND STORIES PER 1401.6.1: <br />BUILDING HEIGHT CALCULATION <br />(ALLOWED - EXISTING)/12.5 X 1 (CF=1) <br />(55-23.5)/12.5 =2.52 <br />BUILDING STORIES CALCULATION <br />(ALLOWED - EXISTING) 1 (CF=1) <br />3 - 1 = 2 LOWER OF 2 VALUES (2 POINTS) TO BE USED. <br />BUILDING AREA PER 1401.6.2. <br />ALLOWABLE AREA PER IBC <br />A +(NS* If) =38,000 + (9,500*0.54)=43,130 <br />At = 38,000 SF PER IBC TABLE 506. =2 <br />NS = 9,500 SF PER IBC TABLE 506.2 <br />Lf = [F1P - 0.251 X W/30 = [(20,700/872)-0.25] = 0.54 <br />F=[(250 x 30) + (250 x 30) + (190 x 3)]=20,700 <br />P=880 <br />W=30 <br />AREA VALUE <br />(ALLOWABLE/1200) *(1-(EXISTING/ALLOWABLE)= <br />(43,130/1200)*[1-(48,928/43,130)]= (-2.5) POINTS <br />COMPARTMENTATION PER 1401.6.1 <br />=0 POINTS <br />TENANT AND OCCUPANCY SEPARATION PER 1401.6.4: <br />N/A - 0 POINTS <br />CORRIDOR WALLS PER 1401.6.5: <br />N/A - 0 POINTS <br />VERTICAL OPENINGS PER 1401.6.6: <br />N/A - 0 POINTS <br />HVAC PER 1401.6,7: <br />SYSTEMS SERVING ONE STORY- CATEGORY E- 5 POINTS <br />AUTOMATIC FIRE DETECTION PER 1401.6.8: <br />SMOKE DETECTORS THROUGHOUT- CATEGORY E- 6 POINTS <br />FIRE ALARM SYSTEM PER 1401.6.9: <br />FIRE ALARM SYSTEM PER IBC 907 WITH FIRE COMMAND STATION PER IBC 911. <br />CATEGORY D - 5 POINTS. <br />SMOKE CONTROL PER 1401.6.10: <br />NONE PROVIDED. CATEGORY A - 0 POINTS <br />MEANS OF EGRESS PER 1401.6.11: <br />REQ'D CAPACITY =640 X 0.2 = 128" 612" PROVIDED > 125% OF REQUIREMENT.. <br />NUMBER OF EXITS REQ'D=3. 8 EXITS PROVIDED > REQUIREMENT. <br />BOTH REQUIREMENTS EXCEEDED, CATEGORY E -10 POINTS <br />DEAD ENDS PER 1401.6.12: <br />DEAD ENDS OVER 70' (INFLATABLE ATTRACTION) <br />CATEGORY A - (-2) POINTS <br />EXIT ACCESS TRAVEL DISTANCE PER 1401.6.13: <br />20 x (ALLOWABLE DISTANCE - ACTUAL DISTANCE)/ ALLOWABLE= <br />20 X (250-207)/250 =3.44 --- 3.4 POINTS. <br />ELEVATOR CONTROL PER 1401.6.14 <br />N/A - 0 POINTS. <br />MEANS OF EGRESS EMERGENCY LIGHTING PER 1401.6.15: <br />2 OR MORE EXITS PROVIDED WITH EMERGENCY EGRESS LIGHTING PER IBC 2702. <br />CATEGORY C - 4 POINTS. <br />MIXED OCCUPANCIES PER 1401.6,16: <br />N/A - 0 POINTS. <br />AUTOMATIC SPRINKLERS PER 1401.6.17: <br />SPRINKLERS REQUIRED PER CODE, AND PROVIDED PER IBC 907, CATEGORY E - <br />4 POINTS. <br />STANDPIPES PER 1401.6.18: <br />STANDPIPES NOT REQUIRED, BUT PROVIDED, PER IBC 905. <br />CATEGORY D - 6 POINTS <br />INCIDENTAL USES PER 1401.6.19 <br />N/A - 0 POINTS. <br />SMOKE COMPARTMENTATION PER 1401.6.20: <br />NIA - 0 POINTS. <br />PATIENT ABILITY AND ATTENDANT RATIO VALUES PER 1401.6.21: <br />N/A - 0 POINTS. <br />SEE TABLES 1401.7 AND 1401.9 FOR SUMMARY INFORMATION. <br />SEE STRUCTURAL DRAWINGS AND CALCULATIONS FOR STRUCTURAL ANALYSIS. <br />3 <br />M $$M-o -s <br />LAND USE/ ZONING <br />JURISDICTION: City of Everett, Washington <br />ZONING: C1 R <br />PARCEL SIZE: 5.19 ACRES <br />EXISTING BUILDING AREA 48,928 SF TOTAL <br />PARKING & LOADING CALCULATION <br />PARKING REQUIRED PER EMC 19.34 TABLE 34.1 : <br />HEALTH CLUB OR <br />ATHLETIC FACILITY 48,928 SF /300 <br />XX STALLS <br />TOTAL REQUIRED <br />163 STALLS <br />PARKING PROVIDED: <br />STANDARD <br />186 STALLS <br />HANDICAPPED <br />6 STALLS <br />TOTAL PROVIDED <br />192 STALLS <br />GOVERNING CODES <br />• 2015 INTERNATIONAL EXISTING BUILDING CODE <br />• 2015 INTERNATIONAL BUILDING CODE (IBC), AS AMENDED BY WAC <br />51-50 <br />• 2015 INTERNATIONAL MECHANICAL CODE (IMC), AS AMENDED BY <br />WAG 51-52 <br />• 2015 INTERNATIONAL FIRE CODE (IFC), AS AMENDED BY WAC 51-54 <br />• 2015 INTERNATIONAL PLUMBING CODE (IPC) AS AMENDED BY WAC <br />51-56 AND 51-57 <br />• 2015 WASHINGTON STATE ENERGY CODE (WSEC) WAC 51-11R <br />2009 ACCESSIBLE & USABLE BUILDINGS AND FACILITIES (ICC/ANSI <br />117.1) <br />• NATIONAL ELECTRICAL CODE (NEC) 2008, AND WASHINGTON CITIES <br />ELECTRICAL CODE 2009, AS AMENDE BY THE CITY OF EVERETT. <br />• EMC EVERETT MUNICIPAL CODE, TITLE 19 EVERETT ZONING CODE <br />DEFERRED SUBMITTALS <br />DESIGN -BUILD SPRINKLER SYSTEMS <br />DESIGN -BUILD FIRE ALARM SYSTEMS. <br />DESIGN -BUILD MECHANICAL SYSTEMS (HVAC) <br />DESIGN -BUILD PLUMBING SYSTEMS <br />DESIGN -BUILD ELECTRICAL SYSTEMS <br />0 <br />_J <br />a� <br />o <br />4i <br />FLYING SQUIRREL SPORTS <br />48,928 S.F. PROJECT AREA <br />EXISTING PARKING 192 STALLS); <br />F* <br />d <br />�, <br />EXISTING ACCESSIBLE PARKING, <br />RAMPS, AND SIGNAGE (TYP.) <br />°a <br />!No <br />m <br />X x <br />X <br />a <br />fl <br />i <br />30 <br />Site Plan <br />1" = 80'-0" <br />EXISTING <br />ADJACENT <br />MICHAEL'S <br />CRAFTS <br />M <br />X <br />2 <br />0 <br />30 <br />t 4 1111�j <br />0 <br />MIX <br />�2 <br />1 Z <br />T <br />O <br />11 <br />X4 <br />0 40' 80, 160' <br />Scale: 1 °' = 80`-0" <br />SITE INFORMATION <br />Parcel Number(s): 28051800404900 <br />Legal Description(s): SEC 18 TWP 28 RGE 05PAR A PAY'N SAVE <br />CORP B.S.P. NO 5-85 REC'D VOL 1 OF SITE <br />PLANS PG 52 AF NO 8602125004 BEING PTN <br />OF NE114 & SE1/4 <br />Building Address: 1325 SE EVERETT MALL WAY <br />EVERETT, WA. 98208 <br />Owner: JUMP EVERETT, L.L.C. D.B.A. <br />FLYING SQUIRREL SPORTS <br />Owner Address: PO BOX 1664, WOODINVILLE, WA, 98072 <br />Owner Phone: (206) 861 5120 <br />BUILDING INFORMATION: <br />PROJECT DESCRIPTION <br />48,928 SF TENANT IMPROVEMENT FOR CHILDREN / YOUTH <br />ACTIVITY CENTER WITH ASSOCIATED CAFE, BAR, AND FOOD <br />PREPARATION AREAS. <br />PROJECT INCLUDES PROVISION OF NEW CLASS I DRY <br />STANDPIPE SYSTEM, AND NEW FIRE CONTROL AND <br />COMMUNICATION CENTER. SEE SHEET CS10 FOR FURTHER <br />INFORMATION. <br />FIRE PROTECTION: SPRINKLED (FULLY) <br />FIRE ALARM SYSTEM PROVIDED <br />OCCUPANCY A-3 <br />CONSTRUCTION TYPE III-N, FULLY SPRINKLERED <br />(EXISTING): <br />SEISMIC ZONE: 3 <br />VICINITY MAP <br />DRAWING INDEX <br />GENERAL: <br />G0.1 COVER SHEET <br />CODE SUMMARY: <br />CS00 <br />PROJECT INFORMATION & CODE ANALYSIS <br />CS10 <br />BUILDING AREA ANALYSIS <br />CS11 <br />MOUNTING HEIGHTS <br />CS12 <br />ACCESSIBILITY STANDARDS, MOUNTING HEIGHTS <br />BASE - BUILDING: <br />BB1.41 <br />ROOF PLAN <br />BB9.10 <br />INTERIOR DETAILS <br />BB9.30 <br />CEILING DETAILS <br />INTERIOR DESIGN: <br />A0.0 <br />PROJECT INFORMATION &SITE PLAN <br />A0.1 <br />DOOR & WINDOW SCHEDULES <br />A0.2 <br />TRAVEL DISTANCE PLAN <br />A1.0 <br />DEMOLITION PLAN <br />A2.0 <br />CONSTRUCTION PLAN <br />A2,1 <br />PLATFORM PLAN <br />A3.0 <br />REFLECTED CEILING PLAN <br />A3.1 <br />LASER LIGHT & SPEAKER PLAN <br />A3.2 <br />LIGHTING SCHEDULES & NOTES <br />A4.0 <br />FINISHES PLAN <br />A4.1 <br />FINISHES SCHEDULE AND DETAILS <br />A5.0 <br />INTERIOR ELEVATIONS <br />A5.1 <br />INTERIOR ELEVATIONS <br />A5.2 <br />INTERIOR & EXTERIOR ELEVATIONS <br />A6.0 <br />MEZZANINE STAIR SECTION <br />A7:0 <br />BAR WASHROOM & SCHEDULES <br />A7.1 <br />MEZZ.WASHROOM & SCHEDULES <br />A8.0 <br />PLATFORM STAIR DETAILS <br />A8.1 <br />JUMP BOX PLATFORM DETAILS <br />A8.2 <br />CHAIN LINK &ACRYLIC PANEL DETAILS <br />A8.3 <br />WHEELCHAIR LIFT SPECIFICATION <br />A9.0 <br />WALL SECTIONS <br />STRUCTURAL: <br />S0.01 <br />GENERAL NOTES AND SHEET INDEX <br />S0.02 <br />GENERAL NOTES <br />S0.03 <br />GENERAL NOTES <br />S0.04 <br />ABBREVIATIONS AND SYMBOLS <br />S1,01 <br />FOUNDATION AND FIRST FLOOR PLAN <br />S1.02 <br />MEZZANINE FRAMING PLAN <br />S1.03 <br />ROOF FRAMING PLAN <br />S2.01 <br />PARTIAL PLAN AND DETAILS <br />S4.01 <br />SECTIONS AND DETAILS <br />S5.90 <br />TYPICAL LIGHT GAUGE <br />CONSULTANT: <br />REGISTRATION STAMPS: <br />9552 REGISTERED <br />ARCHITECT <br />A A A Ae-- <br />STATE OF WASHINGTON <br />CI <br />PROJECT IDENTIFICATION: <br />Tenant <br />Improvements <br />s <br />FLYING SQUIRREL <br />SPORTS <br />1325 SE EVERETT MALL <br />WAY <br />EVERETT, WA. 98208 <br />This drawing is: B <br />1. Copyright 2019 Dykeman, Inc. <br />2. The Architect's Instrument of Professional Service. <br />3. For use on this project only. Obtain Architect's <br />written permission for any other use or reproduction. <br />2020-019 <br />• <br />MARK DATE DESCRIPTION <br />PRINCIPAL IN CHARGE:I TJJ <br />PROJECT MANAGER: WDH <br />PROJECT ARCHITECT: 4 WDH <br />JOB CAPTAIN: AO <br />421111111111 <br />PROJECT <br />INFORMATION & <br />CODE ANALYSIS <br />1 <br />5 <br />