Laserfiche WebLink
NOTES <br />y <br />GENERAL ^ A t S <br />PLEASE DO 6$ ,y' O% DETACH <br />PLAN THEFT PROTECTION <br />ROOFING <br />THIS PLAN IS COPYRIGHTED,AND ALL RIGHTS ARE RESERVED INCLUDING THE RIGHT OF REPRODUCING IN WHOLE OR IN <br />-ALL ROOFING SHALL BE APPLIED ACCORDING TO THE MANUFACTUERER'S RECOMENDATIONS AND CONFORM TO IRC <br />PART, EXCEPT BY CONCET-UAL DESIGN INC. WRITTEN CONSENT,THIS PLAN IS NOT TO BE REPRODUCED BY ANYONE <br />BY ANY METHOD, INCLUDING BLUEPRINTING,PHOTOCOPY[ NG,PHOTOGRAPHY,TRACING,REDRAWING,OR ANY OTHER <br />TRUSSES: <br />MEANS. THIS PLAN MAY NOT BE LISTED BY ANYONE FOR REPEAT CONSTRUCTION ON SALES BROCHURES,ADVERTISING <br />° TRUSS MANUFACTURER SHALL FURNISH SHOP DRAWING CALCULATIONS, ALL TRUSS CONDITIONS CONNECTIONS AND <br />OR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF CONCEPTUAL DESIGN INC. THIS PLAN MAY NOT BE <br />SPACING. DESIGN ROOF LOAD AS PER TRUSS MANUFACTURER ENG. <br />Cth ST SE <br />KNOWINGLY FURNISHED TO OTHERS FOR SUCH PURPOSES. <br />° NO TRUSS SHALL BE FIELD MODIFIED WITHOUT PRIOR APPROVAL OF THE BUILDING DEPARTMENT. <br />A.THE RIGHT OF BUILDING ONLY ONE STRUCTURE FROM THE PLAN YOU HAVE PURCHASED IS GRANTED EXCLUSIVELY TO <br />SHEET METAL <br />SITE LOCATION tJ <br />tip <br />THE OWNER BUILDING CONTRACTOR. UNLAWFUL REPRODUCTION OF THIS PLAN ABSOLVES CONCEPTUAL DESIGN INC. <br />Q <br />Q <br />FROM ALL RESPONSIBILITY AS TO ACCURACY OF THE DRAWINGS. AND WE MAY TAKE SUITABLE LEGAL ACTION AGAINST <br />° PROVIDE AND INSTALL SHEET METAL DUCTS FROM ALL HOODS AND EXHAUST FANS DIRECT TO OUTSIDE. <br />W <br />THE COPIER UNDER COPYRIGHT LAWS. <br />® ALL REQUERED FLASHINS TO BE 26 GAUGE GALVANIZED METAL UNLESS OTHERWISE SPECIFIED. <br />U <br />W <br />S. IF ANY BUILDING IS CONSTRUCTED FROM THIS PLAN OTHER THAN THE ONE FOR WHICH THE PLAN WAS PURCHASED, <br />WE HAVE THE RIGHT ACCORDING TO COPYRIGHT LAW TO RECOVER THE VALUE OF THE BUILDING LESS THE COST OF <br />PLUMBING <br />� <br />CONSTRUCTION. <br />O <br />° PROVIDE AND INSTALL PLUMBING AND FIXTURES AS INDICATED ON PLAINS ACCORDING TO LOCAL PLUMBING CODES. <br />47th ST 5E <br />CODE & STANDARDS <br />ELECTRICAL HEATING <br />° ALL WORKMANSHIP IS TO BE OF A STANDARD EQUAL IN ALL RESPECTS TO GOOD BUILDING PRACTICE. <br />° AT THE TIME OF PREPARATION, THIS PLAN WAS DRAWN IN ACCORDANCE WITH THE CURRENT EDITORS OF <br />INTERNATIONAL RESIDENTIAL CODE IT IS THE RESPONSIBILTY OF THE OWNER BUILDER TO INSURE <br />THAT CHANGES TO THE CODE ARE COMPLIED WITH AND ALL AMENDMENTS ARE INCORPORATED IN THE CONSTRUCTION <br />OF THIS PLAN. ALL WORK SHALL CONFORM TO LOCAL BUILDING CODES AND LAWS WHICH MAY TAKE PRECEDENCE. <br />° PRIOR TO PROCEEDING WITH CONSTRUCTION,THE BUILDER MUST VERIFY ALL INFORMATION. DIMENSIONS AND SPECIFICATION <br />OF THIS PLAN. WRITTEN DIMENSIONS ALWAYS TAKE PRECEDENCE OVER SCALE MEASUREMENTS. <br />° ANY VARIANCES FROM THE STRUCTURAL DRWINGS AND SPECIFICATIONS OR FROM CONDITIONS ENCOUNTERED AT THE <br />JOB SITE,SHALL BE RESOLVED BY THE OWNER BUILDER AND SUCH SOLUTIONS SHALL BE THIER SOLE RESPONSIBILITY. <br />o THE OWNER BUILDER SHALL BE RESPONSIBILE FOR THE CORRECT SITING OF THE HOUSE ON THE PROPERTY AND FOR <br />CONFIRMATION OF ALL REQUERMENTS FOR SITING. CONCEPTUAL DESIGN INC. CAN ACCEPT NO RESPONSIBILITY <br />FOR PLANS COMPLYING WITH THE LOCAL SIDE YARDS AND SETBACKS FOR A SPECIFIC PIECE OF PROPERTY. <br />° THE OWNER BUILDER TO SUPPLY ALL MISSING DIMENSIONS ON SITE PLAN,ALSO ELEVATIONS OF LOT,LEGAL DESCRIPTION, <br />NORTH DIRECTION,MAIN STREETS AND LOCATION OF SERVICES. <br />° CONCEPTUAL DESIGN INC. SHALL NOT BE RESPONSIBLE FOR CONDITIONS SUCH AS SOIL BEARING CAPACITY,DEPTH <br />OF FROST PENETRATION, WATER TABLE OR BURIED STRUCTURES, ETC. <br />° CONCEPTUAL DESIGN INC. DOES NOT ASSUME LIABILITY FOR ANY ERRORS OR OMISSIONS ON THIS PLAI%UNLESS <br />ADVISED IN WRITING OF SUCH ERRORES OR OMISSIONS PRIOR TO COMMENCEMENT OF CONSTRUCTION. <br />° ANY VARIANCES FROM THE STRUCTURAL DRAWINGS AND SPECIFICATIONS ARE THE SOLE RESPONSIBILIT1Y OF THE <br />OWNER BUILDER. CONCEPTUAL DESIGN INC. SHALL NOT BE RESPONSIBLE FOR ANY SUCH VARIANCES MADE OR <br />ADVISED BY ANY OFFICIAL, BUILDER OR OTHER PERSON AND ANY SUCH VARIANCE NULLIFIES ANY RESPONSIBILITY <br />THAT CONCEPTUAL DESIGN INC. MAY HAVE WITH RESPECT TO THIS PLAN OR CONSEQUENT CONSTRUCTION. <br />° ALL REQURRMENTS, WHETHER GENERAL OR SPECIFIC, SHALL BE INTERPRETED IN CONJUNCTION WITH ALL OTHER <br />INFORMATION APPEARING IN THE DRAWINGS AND SPECIFICATIONS. <br />° ALL CONCRETE TO HAVE A MINIMUM COMPRESSIVE STRENGHT OF 2500 PSI AT 28 DAYS. <br />° CONCRETE FOOTINSGS MUST BE PLACED ON UNDISTURBED OR COMPACTED SOIL PER IRC, FOOTINGS SHOWN ON <br />THESE DRAWINGS HAVE BEEN DESIGNED FOR SOIL BEARING CAPACITY OF 1500 PSF. <br />° UNLESS OTHERWISE SHOWN OR NOTED, CONCRETE COVERAGE FOR REINFORCING BARS TO FACE OF BARS SHALL BE AS <br />FOLLOWS: <br />1-CONCRETE IN CONTACT WITH EARTH <br />UNIFORMED 3 INCHES. <br />2-CONCRETE IN CONTACT WITH EARTH <br />FORMED 31NCHES. <br />3-WALL,EXTERIOR FACE 21NCHES <br />4-WALL INETERIOR FACE 3/4" INCHES <br />5-STRUCTURAL SLABS 3/4" INCHES <br />° ALL REINFORCEMENTS SHALL 13E POSITIONED INTO CONCRETE AS PER ENG. DETAILS. <br />° INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. <br />° REFER TO STRUCTURAL ENGINEER NOTES FOR ADDITIOINAL INFORMATION. <br />I <br />ASSUMED DESIGN LOADS <br />(UNLESS OTHERWISE NOTED) <br />° ROOF DESIGN LOAD (LIVE AND DEAD)= 25 P.S.F. <br />m FLOOR DESIGN LOAD (LIVE AND DEAD)= 40 P.S.F. <br />® BALCONY DECK DESIGN LOAD (LIVE AND DEAD)=60 P.S.F. <br />° STAIR (LIVE AND DEAD)=200 P.S.F. <br />m FRAMING LUMBER SHALL BE NUMBER (2) OR BETTER DOUGLAS FIR UNLESS 01-HERWISE SPECIFIED ON PLAN. <br />° ALL BEAMS AND LINTEL SIZES SHOWN ON THE DRAWWGGS ARE BASED ON NUMBER TWO (2) DOUGLAS FIR <br />UNLESS OTHERWISE INDICATED. <br />® FLOOR AND ROOF SHEATHING TO BE LAID CONTINOUS OVER TWO OR MORE SPANS AND FACE GRAIN <br />PERPENDICULAR TO SUPPORTS. ALLOW MIN. SAPCE 106" BETTWEEN END JOINTS AND JOINTS AND 1/8" AT EDGE JOINTS <br />FOR EXPANSIONS AND CONTRACTION OF PANELS. <br />o JOISTS ARE TO BE DOUBLED UNDER PARALLEL PARTITIONS. <br />° JOISTS SHALL BE PLACED TO ACCOMMODATE HEATING AND PLUMBING ETC. <br />° ALL HEADERS AND TRIMMERS TO COMPLY WITH IRC. <br />° REFER TO STRUCTURAL ENGINEER NOTES FOR ADDITIONAL NFORMATON. <br />° OWNER BUILDER TO OBTAIN CERTIFICATE FROM MANUFACTURER OF FLOOR TRUSSES, ROOF TRUSSES <br />AND GLU-LAM BEAMS. <br />® WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. <br />DIMENSIONS ARE FROM THE FACE OF STUDS. <br />PLUMBING <br />® Uniform Pluming Code (IAPMO) <br />n INSTALLATION OF ENTIRE HEATING SYSTEM SHALL COMPLY WITH MANUFACTURERS DIRECTIONS WHERE APPLICABLE <br />AND CONFORME WITH LOCAL CODES AND REGULATIONS IN ALL RESPECTS. <br />° INSTALLATION OF ELECTRICAL ITEMS MUST COMPLY WITH LOCAL ELECTRICAL CODES AND REGULATIONS AND WITH <br />LOCAL ELECTRICAL_ POWER SUPPLY REGULATONS IN ALL RESPECTS. <br />° OUTLET LOCATIONS SHOW ON PLANS COMPLY WITH OR EXCEED NATIONAL ELECTRIC CODE REQUERMENTS AND <br />ARE TO BE USED AS A GUIDE ONLY. ADJUST ACCORDING TO OWNERS AND LOCAL AUTHORITIES REQUERMENTS. <br />° APPROVED HEAT SMOKE DETECTORS TO BE INSTALLED AS REQUIRED PER IRC. <br />° GLAZING WEIGHTS SHALT_ COMPLY WITH IRC <br />m IF GLASS SLIDING PATIO DOORS ARE TO BE INSTALLED, THEY MUST BE OF TEMPERED GLASS. <br />° GLLSS OTHER THAN SAFETY GLASS NOT TO BE USED FOR A SHOWER OR BATHTUB ENCLOSURE. ALL WORK SHALL <br />COMPLY WITH IRC <br />° REFER OT DRAWING FOR SPECIFICATION. <br />NAILING SCHEDULE <br />(SEE IBC) <br />CONNECTION NAILING <br />JOIST TO SILL OR GIRDER, <br />3-8d <br />BRIDGING TO JOIST,AND EACH END <br />2-8d <br />SILL PLATE TO JOIST OR BLOCKING, <br />16d AT 126" O.G. <br />TOP PLATE TO STUD, <br />2-16d <br />DOUBLE STUDS, <br />16d AT 24" O.C. <br />DOUBLED TOP PLATES, <br />16d AT 16" O.C. <br />TOP PLATES, LAPS AND INTERSECTIONS, <br />2-16d <br />CEILING JOIST TO PLATE, <br />3-8d <br />CONTINUOUS HEADER TO STUD, <br />4-8d <br />CEILING JOISTS, LAPS OVER PARTIONS, <br />3-16d <br />BUILT-UP CORNER STUDS <br />16d AT 24" O.C. <br />fw I <br />A. FIELD VERIFIES ALL CABINET DIMENSIONS PRIOR TO FABRICATION. <br />B. KITCHEN COUNTER TOP AND BAR TOP TO BE 36"/42" WITH 4" SPLASH AND RETUERN. <br />C. BATH COUNTER TOP TO BE 30" WITH 4" SPLASH AND RETURN. <br />SPECIFICATIONS <br />A. DO NOT SCALE ANY DRAWINGS NI THIS DOCUMENT. <br />B. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH IRC <br />C. ALL CONSTRUCTION SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS, SECTIONS AND DETAIL. <br />D. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL STRUCTURAL <br />DETAILS. <br />E. MATERIAL NOTES AND SPECIFICATIONS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THE SPECIFICATIONS, <br />F. ALL EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOM HAVE MINIMUM NET OPENING OF 5.7 SQ.FT. <br />AND MINIMUM HEIGHT OF 24", MINIMUM WIDTH SHALL BE 20" EGRESS AND RESCUE FROM SLEEPING <br />ROOMS SHALL HAVE A SILL HIGHT OF NOT MORE THAN 44". <br />° CAULK OVER AND AROUND ALL EXTERIOR OPENING USING NON -HARDENING CAULKING COMPOUND. <br />° FLASH ALL CHANGES OF MATERIALS ON EXTERIOR WALLS. <br />° FLASH OVER ALL EXTERIOR OPENING. <br />° ALL SIDING OR STUCCO 1-0 BE MINIMUMI OF 6" ABOVE FININSHD GRADE. <br />a ALL BALCONY RAILINGS TO BE 36" IN HEIGHT.MAXIMUM SPACING BETWEEN VERTICAL MEMBERS <br />SUCH THAT A SPHERE 4" IN DIAMIETR CAN NOT PASS THROUGH. <br />o FLOOR FINISHES,BATIHROOMI VAN€TIES,SATIH SPLASH AND KITCHEN CABINETS TO MEET SPECIFICATIONS <br />OF OWNER BUILDER. <br />m COATS AND CLOTHES SHALL HAVE AT LEAST ONE ROD AND SHELF. LINEN CLOSET SHALL HAVE 5 <br />ADJUSTABLE SHELVES WHEREVER POSSIBLE. <br />° CERAMIC AND PLASTIC TILES INSTALLED ON WALLS AROUND BATHTUBS OR SHOWERS SHALL BE APPLIED OVER <br />MIISTURE RESISTANTBACKING. <br />° ALL NAILS USED IN THE EXTERIOR TRIMS OR SIDINGS SHALL BE GALVENIZE OR ALUMINUM. <br />° USE COOLER NAILS AT 7" O.C. ON ALL STUDS, PLATES,AND BLOCKING USE 5d NAILS WITH 1/2" WALLBOARD <br />AND 6d NAILS WITH 5/8" UNLESS NOTED OTHERWISE. <br />• TYPE AND THICKNESS OF GYPSUM WALLBOARD AS PER DRAWINGS, ALL WORK TO MELT WITH <br />MANUFACTURER'S REQUERMENTS. <br />® CEILING INSULATION MAY BE LOOSE FILL TYPE OR BATT TYPE, WALL AND FLOOR INSULATION MUST BE <br />BATT TYPE, <br />• WALL AND CEILINGS BETWEEN RESIDENCE AND ATTACHED GARAGE SHALL BE INSULATED. <br />° INSULATION REQUERMENTS MAY VARY WITH HEATING SYSTEM AND WITH LOCAL CONDITIONS. PLEASE <br />CHECK WITH LOCAL AUTHRITIES. <br />° ALL ROOF SPACES SHALL BE VENTILATED WITH SOFFIT,ROOF OR GABLE VENTS OR COMBINATION OF <br />THESE EQUALLY DISTRIBUTED BETWEEN THE TOP OF ROOF SPACE AND SOFFITS. <br />° ALL VENTILATION OF CRAWL SPACES AND ROOF SPACES SHALL CONFORM TO IRC <br />43L-h 9T SE <br />w <br />Em <br />sm <br />of <br />GENERAL <br />NOTES <br />