4735 GLENHAVEN DR 2019 Plans 2022-11-10
>
Address Records
>
GLENHAVEN DR
>
4735
>
Plans
>
4735 GLENHAVEN DR 2019 Plans 2022-11-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 1:07:16 PM
Creation date
12/14/2021 11:20:45 AM
Metadata
Fields
Template:
Address Document
Street Name
GLENHAVEN DR
Street Number
4735
Permit
B1911-017
Year
2019
Notes
Remove extg load bearing wall & install new beam to support
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M EL <br />91 <br />r c z 1 <br />DESIGN LOADS <br />DEAD LOADS: <br />ROOF <br />12 PSF <br />FLOOR <br />12 PSF <br />LIVE LOADS: <br />ROOF (SNOW LOAD) <br />25 PSF <br />RESIDENTIAL <br />40 PSF <br />(LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.10). <br />SEE PLANS FOR ADDITIONAL DESIGN LOADS. <br />STATEMENT OF SPECIAL INSPECTIONS <br />SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A <br />WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF <br />WORK IN ACCORDANCE WITH CHAPTER 1704.4 OF THE IBC. <br />STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER 1S NOT REQUIRED. <br />FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY <br />SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS <br />SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. <br />SPECIAL INSPECTION <br />OPERATION CONT PERIODIC REMARKS <br />SOILS <br />PIPE PILING INSTALLATION X <br />PILING REFUSAL VERIFICATION X <br />CONCRETE <br />ADHESIVE ANCHORS X IF REQ'D <br />NOTE: <br />ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL <br />INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE <br />ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL <br />RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT <br />TO THE ATTENTION OF THE DESIGN TEAM. <br />i1M I-plivt L00 10imairl"11,01 o, <br />SOILS REPORT: REPORT NO: 1113119 <br />PREPARED BY: NELSON GEOTECHNICAL ASSOCIATES, INC <br />DATED: 07/03/19 <br />ALLOWABLE SOIL PRESSURE: 2,000 PSF (ASSUMED; TO BE FIELD VERIFIED DURING CONSTRUCTION) <br />FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND <br />AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS <br />REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE <br />CONDITIONS AND MUST THEREFORE BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW <br />COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. <br />IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR <br />MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE <br />THAN 10% FINES (PASSING THE #200 SIEVE). <br />FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE <br />THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM <br />TEST METHOD D1557-00. <br />BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE <br />DRAINAGE. PROVIDE DAMPPROOFING AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER <br />ARCHITECTURAL SPECIFICATIONS. <br />EXCAVATIONS AND DRAINAGE INSTALLATION SHALL BE OBSERVED BY A SOILS ENGINEER RETAINED BY THE OWNER. <br />IF EXCAVATION SHOWS SOIL CONDITIONS TO BE OTHER THAN THOSE ASSUMED ABOVE NOTIFY THE STRUCTURAL <br />ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. <br />UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN <br />CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY <br />VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. <br />NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD <br />ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR <br />WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING <br />SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL <br />MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: <br />NAIL <br />SHANK 0 <br />MIN LENGTH <br />8d COMMON <br />0.1310 <br />2 1/2" SHANK <br />10d COMMON <br />0.1480 <br />3" SHANK <br />12d COMMON <br />0.1480 <br />3 1/4" SHANK <br />16d COMMON <br />0.1620 <br />3 1/2" SHANK <br />10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING <br />MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED <br />WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET, ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS <br />ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. <br />ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS <br />OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE <br />SHANK AND THREADED PORTIONS PER NDS 11.1.3. <br />CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG <br />TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED <br />BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, <br />SCREWS, OR BOLTS IN EACH MEMBER. <br />INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE <br />(MINIMUM) AS MEMBERS CONNECTED. <br />GALVANIZATION <br />UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED <br />ACCORDING TO THE FOLLOWING TABLE: <br />G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA <br />G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA <br />HDG = HOT DIP GALVANIZED <br />SST300 = TYPE 316L STAINLESS STEEL <br />It IIIion IA al,al, g waurI'[lil ol-4wilmAE1a1f,U."Imamsimlliviu:Im lg <br />FABRICATED IN CONFORMANCE WITH THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES) REPORT <br />NO. ESR-1387 OR CCMC REPORT NO. 12627-R, 08675-R, AND 11161-R. EACH MEMBER SHALL BE IDENTIFIED BY A <br />STAMP INDICATING THE PRODUCT TYPE AND GRADE, ICC-ES OR CCMC REPORT NUMBER, MANUFACTURER'S NAME, <br />PLANT NUMBER AND INDEPENDENT INSPECTION AGENCY'S LOGO. FABRICATOR SHALL BE CERTIFIED, MEMBERS <br />SHALL MEET THE FOLLOWING MINIMUM STANDARDS: <br />TIMBERSTRAND, MICROLLAM, AND UNTREATED PARALLAM MEMBERS ARE INTENDED FOR DRY -USE APPLICATIONS. <br />UNLESS NOTED OTHERWISE, ENGINEERED WOOD BEAMS EXPOSED TO WEATHER SHALL BE TREATED PER <br />MANUFACTURES RECOMMENDATIONS. <br />EXISTING BUILDING <br />CONTRACT R SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING <br />DEPICTED I THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE <br />REDESIGN. <br />CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS <br />PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. <br />GENERAL. <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY <br />DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL <br />PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. <br />CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE STRUCTURAL ENGINEER FOR <br />APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT <br />SATISFY THIS REQUIREMENT. <br />DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT <br />SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF <br />CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER. <br />IN <br />(ENGINEIE"RiNk <br />250 4TH AVE. Se, SUITE 200 <br />EDMONDS, WASHINGTON 98020 <br />PHONE (425) 778-u800 <br />FAX (425) 778-5536 <br />�l(J%vTA� <br />y <br />Q <br />01W19 <br />DESIGN: <br />NAL' <br />,k <br />DRAWN: <br />x <br />JEG <br />CHECK: <br />MTM <br />JOB NO: 19200.10 <br />DATE: 1 0/31 /10 <br />'I <br />cl <br />ZF <br />0 <br />Fd <br />I— <br />lP <br />a <br />SHEET: <br />I <br />Z <br />