My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7130 HIGHLAND DR 2018 Plans 2022-12-01
>
Address Records
>
HIGHLAND DR
>
7130
>
Plans
>
7130 HIGHLAND DR 2018 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 8:22:18 AM
Creation date
12/14/2021 11:49:58 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND DR
Street Number
7130
Permit
C1811-006
Year
2018
Notes
SFR addition
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
„ " 99 9� CAST IN PLACE HOLD-DOWN SCHEDULE FOR CONCRETE i=OUNDATON I T L T <br />� OSB or PLYWOOD SHEAR WALL SCHEDULE FOR SEISMIC DESIGN CATEGORY D AND E GENERAL: <br />ES <br />MARK ALLOW. TENSION LOAD FOR SPIT or HF ANCHOR MODEL FOR MIN, <br />SILL PLATE INTERIOR ON THE # MONO POUR DIAM. EMBEDMENT VERTICAL WOOD ALL METHODS, MATERIALS AND WORKMANSHIP ARE TO CONFORM <br />ALLOWABLE TO THE INTERNATIONAL BUILDING CODE 2015 EDITION, AS <br />SILL BOTTOM PLATE ANCHOR UNLESS WALLS TOP SI-IEAR PLAN TYPE M1DW'ALL ENDWALL c�c CORNER MID�IVALL or CORNER IN. IN. MEMBER MIN. <br />MARK SHEATHING AMENDED AND ADOPTED BY THE GOVERNING JURISDICTION, <br />SHEATHING EDGE NAILING PLATE NAILING OTHER CONNECTION SEISMIC,/WIND STHD10 3400 @ 8" wail 2175 @ 8" wall 20 -16d SINKER 10 2-2x SIZE SPECIFIED ON U.N.O. ON { ) THE CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING: <br />THE PLAN THE PLAN a. PROVIDING TEMPORARY SHORING AND BRACING UNTIL ALL <br />STHD14 3815 @ 8" wall 3500 @ 8 wall (24)-16d SINKER 14 2-2x STRUCTURAL ELEMENTS HAVE BEEN INSTALLED AND <br />7/16" APA RATED 16d @ 6" o.c. to 5/8,= <br />8d @ 6 o.c, 2X 99 n 9 599 " 2-2x CONNECTION COMPLETED. <br />PI-6 SHEATHING ONE SINGLE blocking or 5' - 0" o.c. A35 @ 24 o.c. 2 ,0plf/336plf HDU2-SDS2.5 2215 (HF) 2215 (HF) SSTB16 / SB,x24 5/8 12-8 18 b. FIELD VERIFICATION AND COORDINATION OF ALL DIMENSIONS <br />SIDE joist (interior walls) HDU4-SDS2.5 3285 HF 3285 HF 5 5J9 " AND ELEVATIONS BEFORE PROCEEDING WITH THE WORK. <br />{ { ' SSTB24 / SBgx24 5/8 20-g / 18 2-2X C. BRINGING TO THE ATTENTION OF THE BUILDING DESIGNER <br />7/16" APA RATED 16d @ 4" o.a. to 5 8 � @ <br />PI-4 SHEATHING ONE 8d @ 4" o.c. 2X SINGLE blocking Cr A35 @ 18 o.c. 349plf/488pif HDU5-SDS2.5 4065 HF) 4065 HF) 5 5 ANY CONFLICTS IN DIMENSIONS, MATERIALS OR NOTES <br />3 - 6 o.c. ( { SBh24 / SB$x24 5/8 18 2-2x SHOWN ON THE PLANS, <br />SIDE Dist (interior walls) 4305 (HF) 4-305 (HF) SSTB28 / SB8x24 7/899 24-8" / 18" 2-�x d. INSTALLATION of PROPRIETARY PRODUCTS IN ACCORDANCE WITH <br />7/16" APR RATED 9 16d @ 3" o.c. staggered 5 %8" 0 @ HDU8-SDS2.5 ' MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. <br />P1 -3 SHEATHING ONE 8d @ 3 o.c. 2X to DBL blocking or ;foist \ - 69i Doc A35 @ 12' 0.c. 450plf/630plf 6970 (DF) 5550 (DF) SSTB28 / SB8x24 7/899 24-899 / 18" 4>;6 <br />INSPECTIONS_ <br />SIDE interior �rualls - <br />7870 (DF) 5550 (DF) SSTB28 / SB8x24 7 8'9 24-g" / 18 6x6 a. PERIODIC SPECIAL INSPECTIONS REQUIRED FOR WIND AND SEISMIC <br />7/16" APA RATED 1 6d @ 2" o.c. staggered 5/8" 0 @ - / RESISTANCE SUCH AS ANCHORS & STRAPS EMBEDDED IN TO <br />PI-2 SHEATHING ONE 8d @ 2" o.a. 2>t to DBL blocking or joist 2' - 0" o.c. A35 @ 10" o.c. 589pIF/824p1f CONCRETE <br />SIDE interior walls b. IF INSPECTION OF EPDXY GROUTED ANCHORS IS REQUIRED BY THE <br />BUILDING OFFICIALS, IT CAN BE PROVIDED BY AAR TESTING <br />NOTES: LABORATORY INC. Ph: (425)-881-5812 or ANOTHER CERTIFIED <br />1. All fasteners shall be common wire or galvanized box and meet the following criteria: <br />AGENCY. <br />8d common = 0.131 "0 x 2-1/2" min. � WOOD ROOF TRUSSES: <br />10d common = 0.148"0 x 3" min. NOTES: Minimum Concrete Strength 2500psi U.N.O. METAL PLATE CONNECTED WOOD TRUSSES ARE TO BE DESIGNED BY A <br />8d box galvanized = 0.1130 x 2-1/2"min. Extend foundation down as required to receive hold-down A.B. embedment. WASHINGTON STATE PROFESSIONAL ENGINEER IN ACCORDANCE WITH ANSI/TPI <br />10d box galvanized = 0.1280 x 3" min. Threaded rod and coupler as required. 1-2002 "NATIONAL DESIGN STANDARDS FOR METAL -PLATE CONNECTED WOOD <br />2. Schedule is based on IBC 2015 for wood framed ,malls with 2x4(minimum) SPF#2 or BTR. For Two pour foundation see "SIMPSON" Catalog SSTBL Model. TRUSS CONSTRUCTION". TRUSSES INCLUDING DRAG TRUSSES AND SHEAR FRAMES <br />ARE TO BE PLANT FABRICATED BY A MANUFACTURER. THE TRUSS ERECTION <br />3. Sheathing is to be span rated 24/0 minimum and may be plywood or CSB installed on For sill plate more then 1-1/2" use anchor bolts SSTBL Model. CONTRACTOR IS RESPONSIBLE_ FOR ALL TEMPORARY BRACING DURING <br />studs are spaced 16" o.c. max. For epoxy -tie hold-down anchor application see typical detail below. INSTALLATION AND FOR ALL PERMANENT BRACING IDENTIFIED ON THE TRUSS <br />4. Space nails at 12" o.c. along intermediate framing members. For addition information see "Simpson Strong -Tie Connectors catalog" PLANS. <br />5. Sheathing is to be directly applied to studs and all edges blocked. Tighten all nuts on bolted connections at the latest procticable time SHEAR WALL FRAMING <br />6. For shear walls: PI-3 & PI-2 all framing members receiving before covering them with further construction. SEE SHEAR WALL SCHEDULE <br />edge nailing from abutting panels shall not be less than 3-inch nominal member or dbl studs fastened together per <br />bottom plate nailing schedule above. Plywood joint nailing shall be staggered. PLYWOOD DIAPHRAGM <br />7. Anchor bolts to have a minimum 3"x3"x1 /4" thick plate washers. 4 1/2" o HOLD-DOWN ROOF SHEATHING OF SIZE SHOWN ON THE ARCHITECTURAL PLANS IS TO BE APA <br />8. Provide full width blocking below post at ends of shear walls. -I11 3/4" \ PER PLAN 1 RATED 15/ 32" PLYWOOD or 7/16" O.S.B. SPAN RATED 24/16 MINIMUM <br />9. Install anchor bolts within 12" and no closer than 4" of each plate break and holdovvn anchor. r m 7rl- -- 0 DIRECTLY NAILED TO SUPPORTING TRUSSES OR RAFTERS with LONG DIMENSION10. Edge nailingat ends of shear walls is to post with tie -down attached to it, 7�2 \� -- PERPENDICULAR TO SUPPORTS with 8d COMMON @ 6" o.c. AT ALL EDGES AND <br />even if sheathing extends past the past. CONCRETE I <br />ID 12 o.c. AT ALL INTERMEDIATE SUPPORTS. <br />; <br />SLOTTED BPS5/8-3 FOR SLOTTED BPS5/8-6 FOR STANDARD CUT 1.3/4" 0 FOUNDATION <br />-6 �-�--- - - --- -- 5/8"0 ANCHOR BOLTS 5/8"0 ANCHOR BOLTS x1 1/16" x3/64" WASHER.FLOOR SHEATHING (SUB -FLOORING) OF SIZE SHOWN ON THE ARCHITECTURAL <br />STEEL STRAP SCHEDULE <br />TYPE <br />ALLOW. TENSION <br />LOAD # for SPF <br />or BTR <br />FASTENERS <br />EACH END <br />MOTES <br />CS16 <br />1705 <br />13-8d <br />ST6224 <br />2540 <br />14-16d <br />H2.5 <br />365 <br />10-8d total <br />H 1 <br />400 <br />10-8d total <br />A35 <br />600 <br />12-8d x 1 .1 /2" <br />A34 <br />445 <br />8-8d x 1. 1 / 2" <br />HALF THE SPAN LENGTH OF THE JOIST. <br />C. FLOOR JOISTS ARE TO BE BLOCKED AT ALL BEARINGS. <br />d. WALL TOP PLATES ARE TO HAVE STAGGERED SPLICES A MINIMUM OF <br />4'-0" APART AND NAILED TOGETHER IN THE SPLICE ZONE WITH MINIMUM OF <br />(8)-16d COMMON NAILS. <br />e. WOOD IN CONTACT WITH THE WEATHER, SOIL, CONCRETE or MASONRY IS <br />TO BE PRESERVATIVE TREATED. <br />METAL_ CONNECTOR FOR WOOD: <br />THE MODEL NUMBERS OF METAL CONNECTORS WHERE SPECIFIED ON THE <br />PLANS ARE THOSE AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY, <br />INC. OR USP EQUIVALENT AS SPECIFIED IN THEIR LATEST CATALOGS, <br />BOLTS ARE TO BE A307 WITH WASHERS AT ALL WOOD SURFACES BENEATH <br />HEAD OR NUTS. BOLT HOLES ARE TO BE 1/16" GREATER IN DIAMETER <br />g� I {� C ANCHORAGE <br />� I n THAN BOLT DIAMETER. <br />N E VV EXISTING �I FOUNDATION SILL PLATE AN C H 0 RAG E AND STYPE AS SPECIFIEBE D OBY SIMPSON. <br />NAILSRE AND OF QUANTITY, SIZE, LENGTH <br />I <br />EPDXY -TIE HOLD-DOWN ANCHOR RETROFIT <br />FOUNDATION <br />ROOF SHEATHING PER PLAN, NAILED OUTRIGGER CONNECTION DESIGN CRITERIA: 1. Verif all dimension With architectural plains. Verify all <br />w/8d NAILS @ 6"o.c. @ PANEL EDGES PER DIET. "5/S1" 2x4 BRACE AT 6'-0"o.c. ROOF DEAD LOAD '15 psf y P y <br />& 12"o.c. ALONG INTERMIDIATE 8d @ 6"o.c. MAX., APPLY WHEN SNOW LOAD 25 psf dimensions prior to start of work or ordering materials. <br />FRAMING. (NO BLOCKING) DIAGHONAL BRACING HAS ROOF TRUSS BOTTOM CHORD LIVE LOAD 1Opsf <br />GABLE END LENGTH MORE THAN 6' ROOF SHEATHING 8d @ 4"o.c. TO 2x4 (ROOF TRUSS BOTTOM CHORD LIVE LOAD DOES NOT ACT 2. Bottom of all footing are to be level and rest on <br />BLOCKING ' <br />/,---TRUSS 2x4 w/ A34 @ PER PLAN CON,CURENTLY WITH THE ROOF LIVE LOAD) undisturbed soil regardless of elevations shown on plan. <br />W/SHEATHING FLOOR DEAD LOAD 10 psf SIMPSON H1 SEISMIC CLIP @ PER HEATH EACH END FLOOR LIVE LOAD 40 p3. Clean looting excavation immediately before concrete <br />2ERIOR, IF H1 LOCATED AT i IMPORTANCE FACTOR 1.0 psf <br />is placed to remove all softened or loosened materials. <br />INTERIOR SIDE OF THE WALL, I (5)-8d ROOF 9, <br />ADD RBC ROOF CLIP @ 24"o.c. SHEATHING TO 2x4 OUTRIGGER. H1 @ 24 o.c. WIND VELOCITY (3-second gust) 110 mph 4. Do not locate foundation Vent Openings under shear <br />FROM BLOCKING TO WALL TOP BLOCKING \ @ 24"o.c.F WIND EXPOSURE "B„ walls with anchor bolts spacing less than 24°' o.c. OR <br />PLATE. INTERNAL PRESSURE FACTOR 018 <br />H2.5 EACH SIDE AT MULTI -PLY <br />TRUSS <br />MANUFACTURED <br />8d NAILS AT / -- TRUSSES PER <br />611o.c. SHEATHING---------. PLAN <br />TO BLOCKING <br />\\ <br />EDGE NAILING PER <br />I <br />SHEAR WALL SCHEDULE <br />I <br />SHEAR WALL PER <br />TO BE USED BETWEEN p PLANS IS TO BE 3/4" PLYWOOD or 23/32" O.S.B. APA RATED STUDD-I-FLOOR <br />NUTS AND SLOTTED II ll b J ll ll p <br />3 � fi ll D Q Co II'll �°. UNDERLYMENT GRADE ,.with LONG DIMENSION PERPENDICULAR TO SUPPORTS with <br />BEARING PLATES ifll co I- II II 8d COMMON @ 6" o.c. AT ALL EGES AND 12" o.c. AT ALL INTERMEDIATE <br />p <br />NEW FOUNDATION n P °VII III SUPPORTS. <br />1' 6" 4" WOOD FRAMING <br />BP5/8-3 FOR 5/8"0 RETROFIT ANCHOR 1 3/4" 2x LUMBER TO BE HF#2 or BETTER EXCEPT WALL STUDS MAY BE HF STUD <br />2" MAX. ANCHOR BOLTS 2 3/4" MAX. PER TABLE <br />MIN MIN. GRADE &SILL PLATE HF3 WHERE NOT SPECIFIED ON THE PLANS; <br />(3)-#4 REBAR EPDXY 4 5/16" FOR HDU2; HDU4; HDU5 <br />GROUTED TO EXISTING 1/2" MAX. GAP BPS5/8-6 - 1/2" MAX. GAP 4.3/8" FOR HDU8 a. COLUMN 1N WALLS ARE TO BE (2)-2x STUDS OF THE SAME WIDTH AS <br />a ✓ FOUNDATION BEARING PLATE ELEVATION SECTION <br />m C L C L THE WALL and NAILED WITH 16d @ 24" o.c. (UNLESS NOTES OTHERWISE) <br />BP5/8-3 or BPS5/8-3 CU NWA.SDH'ER b. FLOOR FRAMING PARALLEL TO INTERIOR PARTITIONS IS TO HAVE TWO <br />BEARING PLATE FLOOR JOISTS DIRECTLY BENEATH EACH PARTITION IF PARTITION EXCEEDS ONE <br />a. <br />-2x P.T. SILL PLATE <br />4 <br />FINISH GRADE � FINISH GRAD <br />EXISTING FOUNDATION - REiNFORCEMENT�r <br />= = = = = PER PLAN <br />a 5/8" 0 ANCHOR BOLT <br />__V_1a a PER PLAN, 12" MAX. <br />FROM ENDS & 7" G <br />a MIN. EMBEDMENT <br />OPTION 2 EXTERIOR CONCRETE OPTION 3 <br />For addition information see "Simpson \\\\\ sTEM WALL PER PLAN <br />FOR WALLS SHEATHED ON BOTH SIDES ANCHOR BOLTS TO BE STAGGERED <br />Strong -Tie Connectors catalog" <br />Q m <br />2 <br />1 \ <br />(4)-16d NAILS <br />2x4 DIAGONAL <br />P' <br />BRACE @ 48"o.c. <br />SIMPSON A34 @ 48"o.c. <br />BRACE TO TOP WALL PLATE <br />2x NAILER W/16d @ 6"o.c. <br />16d @ 6"o.c. <br />PANEL EDGE NAILING <br />SIMPSON <br />REQUIRED EPDXY -TIE <br />MINIMUM EMBEDMENT 6" WALL <br />ADHESIVE FOR FULL <br />ANCHOR <br />HOLD-DOWN <br />'HD' CAPACITY <br />END WALL <br />MIDWALL <br />HDU2 <br />"SIMPSON" <br />10" <br />10„ <br />HDU4 <br />SET-XP <br />RFB #5x16 <br />857# ASD <br />1357# ASD <br />HDU5 <br />(1200# LRFD) <br />(1900 LRFD) <br />"SIMPSON" <br />7/8"0 <br />15" <br />15" <br />HDU8 <br />SET-XP <br />857# ASD164-2# <br />ASD <br />THRU-BOLT <br />(1200# LRFD) <br />(2300 LRFD) <br />HDU11 <br />CAST IN PLACE <br />HDU14 <br />APPLICATION ONLY <br />s' rri`x <br />Kzt FACTOR 1.00 <br />locate them at rim joist. <br />5. All back -fill against foundation wails must be <br />FOR SEISMIC DESIGN USED EQUIVALENT LATERAL FORCE PROCEDURE <br />compacted to 90% relative density unless otherwise <br />4 I <br />@ (4)-10d <br />SEISMIC FORCE RESISTING SYSTEM IS BEARING LIGHT FRAMED WALLS <br />directed by the soil report. <br />EACH BLOCK <br />' <br />WOOD STRUCTURAL PANELS <br />OCCUPANCY CATEGORY II <br />6. Lap all bars in accordance w/ACI 318 but not less <br />1 -6, MAX. <br />--- <br />SEISMIC FORCE -RESISTING SYSTEM BEARING WALL SYSTEM <br />than 40 bar diameter nor less than 1 8' . All horizontal <br />DROPPED GABLE <br />/(2)-16dD <br />SITE CLASS "D" <br />bars shall be developed at corners. <br />P <br />END TRUSS <br />DESIGN SPECTRAL RESPONSE ACCEL. Sds 0.930 <br />7, Contractor to provide concrete landing and or stoop <br />DESIGN SPECTRAL RESPONSE ACCEL Sd1 0.532 <br />IMPORTANCE FACTOR FOR SEISMIC DESIGN 1.0 <br />P at all egress door as er local codes, <br />SHEATH PER <br />RESPONSE MODIFICATION FACTOR 6.5 <br />8. The minimum clear spacing between parallel bars in a <br />GRAIN NAILS P1-6 <br />SEISMIC DESIGN CATEGORY "D" <br />layer shall be D-bar but not less than 1 inch, <br />SEISMIC RESPONSE COEFFICIENT 0.1431 <br />g. See plan and shearwall schedule for anchors spacing <br />FOUNDATION DESIGN CRITERIA <br />and shearwall requirements. Elsewhere use 5/879 0 anchors <br />at 5P-O"o.c. 129' max from ends U.N.Q. <br />Allowable soil bearing capacity 1500psf <br />110. Follow "SIMPSON STRONG TIE" Catalog instruction for <br />Equivalent Fluid Pressure 35psf/ft <br />installation of all connectors. <br />Lateral Sliding Coefficient 0.25 <br />11 The ex Deed concrete rnust be 3000 <br />PLAN & SCHEDULE Lateral Passive Pressure 150psf/ft P ! P I I <br />Frost depth 18" <br />\\--GABLE END WALL Concrete Compressive Strength (USD Design) 2500psi <br />The minimum cement content per cubic yard <br />TRUSS C 0 N N ECT O N TRUSS GABLE END OUTRIGGER C 0 �i N ECT 0 of concrete is 5.2 sacks' Special inspection is y 0" L- <br />\ \ \ not required R U� IEi;"JEI FOP,', <br />2, <br />RF-10 I RF-46 � RF-70 Concrete Compressive Strength (Weathering) 3000psi � �.� <br />Concrete reinforcing bars 40000psi <br />Anchor bolts A307 or BTR <br />
The URL can be used to link to this page
Your browser does not support the video tag.