Laserfiche WebLink
THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS. -` <br />CRITERIA <br />GENERAL RESIDENTIAL NOTES: <br />DESIGN 1S IN ACCORDANCE WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE AS AMENDED BY CITY OF EVERETT <br />20. <br />PROVIDE FIRE BLOCKING AT ALL PLUMBING PENETRATIONS <br />1. <br />UNDER -FLOOR AREAS SHALL BE VENTILATED BY AN APPROVED <br />AND AT 10'-0" O.C. INTERVALS (HORIZONTAL AND <br />MECHANICAL MEANS OR BY OPENINGS 1N EXTERIOR FOUNDATION MALLS. <br />VERTICAL) IN ALL WALLS. FIRE STOP BETWEEN ALL <br />SUCH OPENINGS SHALL HAVE A NET AREA OF NOT LESS THAN 1 SO. FT, <br />INTERCONNECTIONS OF CONCEALED VERTICAL AND <br />FOR EACH 150 SQ. FT. OF UNDER -FLOOR AREA. OPENINGS SHALL BE <br />HORIZONTAL SPACES. FIRESTOP IN OPENINGS AROUND <br />LOCATED AS CLOSE TO CORNERS AS PRACTICAL AND SHALL PROVIDE CROSS <br />VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES, AND <br />VENTILATION. THE REQUIRED AREA OF SUCH OPENINGS SHALE BE <br />SIMILAR OPENINGS WHICH AFFORDS PASSAGE FOR FIRE AT <br />APPROXIMATELY EQUALLY DISTRIBUTED ALONG THE LENGTH OF AT LEAST TWO <br />CEILING AND FLOOR LEVELS WITH NONCOMBUSTIBLE <br />OPPOSITE SIDES. IRC R408.1 <br />MATERIALS. FIRE BLOCK CONCEALED SPACES BETWEEN <br />2. <br />CRAWL SPACE, UNOBSTRUCTED ACCESS, MINI. 18" X 24", IRC SEC. R408'Yz41 <br />STAIR STRINGERS AT THE TOP AND BOTTOM OF RUN AND <br />BETWEEN STUDS ALONG AND IN LINE WITH THE RUN OF <br />THE STAIRS IF THE WALLS UNDER THE STAIRS ARE <br />3. <br />ATTIC VENTILATION: 1/150 OF ATTIC AREA OR 1/300 IF 1/2 IS IN SOFFIT <br />UNFINISHED. IRC SEC. R602.8 <br />AND 1/2 IS 3' ABOVE PLATE LINE, OR 1/300 IF A VAPOR RETARDER OF 1 <br />21 <br />STAIRWAYS SHALL HAVE A V Qv1UM HEADROOM IN ALL PAR1-S OE THE <br />PERM IS INSTALLED ON THE WARM SIDE OF THE INSULATION. IRC SEC. R806.2 <br />STAIM,IIAYSHALL NOT BE LESS THAN 6 F-ET 8 INCHES (2035 rnm) MEASURED <br />VERTICALLY F ROM THE S!_OPED PLANE ADJOINING THE TREAD NOSING OR FROM <br />4. <br />IN ROOMS NOT PROVIDED WITH AN OPERABLE WINDOW OF 1.5 SO, FT. OR <br />THE FLOOR SURFACE OF THL LANDING OR PLATFORM.IRC SEC. R311.5.2 ALL <br />GREATER, A MECHANICAL VENTILATION SYSTEM, CAPABLE OF PROVIDING 5 AIR <br />; IAND RAILS SHHALL RE INSTALLED AT 3A" H OivI TREAD NOSING AND EACH DND <br />CHANGES PER HOUR, SHALL BE PROVIDED. <br />OF RAIL SHALL TERMINATE INTO TALL. <br />22. <br />RISER HEIGHT SHALL HAVE A MAXIMUM RISER HEIGHT OF <br />5. <br />PROVIDE SOURCE SPECIFIC AND WHOLE HOUSE VENTILATION AS REQUIRED BY THE <br />7 3/4 INCHES (196 mm). THE RISER SHALL BE MEASURED <br />WASHINGTON STATE ENERGY CODE, 2015 EDITION. <br />VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT <br />6. <br />VENT DRYER, EXHAUST FANS, AND COOKTOP/RANGE/HOODS TO <br />TREADS. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT <br />THE OUTSIDE. INSULATE ALL METAL VENTING. <br />OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE <br />THAN 3/8 INCH (9.5 mm). IRC SEC. R311.5.3.1 <br />23. <br />TREAD DEPTH SHALL BE 10 INCHES (254 mm). THE TREAD <br />DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE <br />THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF <br />ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S <br />7. <br />DRAFTSTOPS SHALL BE PROVIDED FOR USABLE SPACE <br />LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY <br />ABOVE AND BELOW A CONCEALED SPACE OF A FLOOR- <br />FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY <br />CEILING ASSEMBLY AND SHALL BE INSTALLED SO THAT <br />MORE THAN 3/8 INCH (9.5 mm). IRC SEC, R311.5.3.2 <br />THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED <br />24. <br />SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING <br />1,000 SQUARE FEET. DRAFTSTOPPING SHALL DIVIDE THE <br />LOCATIONS: <br />CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. <br />1. IN EACH SLEEPING ROOM. <br />IRC R502.12 <br />2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE <br />8. <br />GARAGE OCCUPANCY SEPARATION MIN. 1 HR. <br />IMMEDIATE VICINITY OF THE BEDROOMS. <br />TAPED AND FINISHED, IRC R309.2-UON. <br />3. ON EACH ADDITIONAL STORY OF THE DWELLING, <br />INCLUDING BASEMENTS, BUT NOT INCLUDING THE CRAWL <br />9. <br />PROVIDE WATER RESISANT GWB ABOVE ALL PREMANFATURED TUB SHOWER AND <br />SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR <br />SHOWER SURROUNDS. EXTEND A MIN 2` FROM EDGES AND BEHIND TOILET. <br />DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN <br />INTERVENING DOOR BETWEEN THE ADJACENT UNITS. <br />10. <br />INSTALL ALL PREFABRICATED FIREPLACES, STOVES AND <br />A SMOKE ALARM INSTALLED ON THE UPPER LEVEL <br />RELATED ASSEMBLIES IN ACCORDANCE WITH U.L. <br />S SUFFICE FOR THE ADJACENT LOWER LEVEL <br />APPROVED MANUFACTURER'S SPECIFICATIONS. <br />PROVIDED THAT THE LOUVER LEVEL IS LESS THAN ONE <br />PROVIDED <br />11. <br />HEARTH EXTENSIONS: HEARTHS SHALL EXTEND AT LEAST <br />FULL STORY BELOW THE UPPER LEVEL. IRC SEC. P=31=3a1 <br />16" FROM THE FRONT OF, AND AT LEAST 8" BEYOND EACH <br />25. <br />POWER SOURCE FOR SMOKE ALARMS: POWER SOURCE IN A <br />SIDE OF THE FIREPLACE OPENING. WHERE THE <br />NEW CONSTRUCTION SHALL RECEIVE THEIR PRIMARY POWER <br />FIREPLACE OPENING IS 6 SQ. FT. OR LARGER, THE <br />FROM THE BLDG WIRING WHEN SUCH WIRING IS SERVED FROM <br />HEARTH EXTENSION SHALL EXTEND AT LEAST 20" IN <br />A COMMERCIAL SOURCE, AND WHEN PRIMARY POWER IS INTERRUPTED, <br />FRONT OF, AND AT LEAST 12" BEYOND, EACH SIDE OF <br />SHALL RECEIVE POWER FROM A BATTERY. IRC SEC. IR&1.3-.2 I <br />THE FIREPLACE OPENING. <br />25.1 <br />r r ,o <br />PROVIDE CO DETECTORS IN THc VICINITY OF HABITABLE SLEEPING AREAS, VERIFY <br />12. <br />HVAC UNITS: WHEN HVAC OR WATER HEATERS ARE <br />W/ BUILDING OFFICAL AS TO EXACT LOCATIONS. ONLY REQUIRES WHERE FOR <br />PLACED IN AN AREA SUSCEPTIBLE TO MOISTURE, ALL <br />GAS APPLIANCES AND OR OR WOOD FUEL HEATING SOURCES. <br />PILOT LIGHTS, BURNERS, SWITCHES OR HEATING <br />ELEMENTS SHALL BE LOCATED 18" ABOVE THE FLOOR OR <br />26. <br />CEILING HEIGHT: HABITABLE ROOMS, HALLWAYS, CORRIDORS <br />SLAB. PROVIDE SEISMIC ANCHOR STRAPS FOR ALL WATER <br />BATHROOMS, TOILET ROOMS, LAUNDRY ROOMS AND <br />HEATERS. <br />BASEMENTS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN <br />13. <br />APPLICATION AND INSTALLATION OF INSULATION AND <br />S86•R•CE AN•D-WHI,EN--FRrm-CRY-p,cC WER: 1•S--I°NITERRIJ-P-TIED, <br />VAPOR BARRIERS SHALL COMPLY WITH STATE OF <br />7 FEET (2134 mm). THE REQUIRED HEIGHT SHALL BE MEASURED <br />WASHINGTON THERMAL IINSULATION STANDARDS <br />FROM THE FINISI-I FLOOR TO THE LOWEST PROJECTION FROM <br />THE CEILING. IRC SEC. 305.1 <br />14. <br />GLAZING SHALL BE IN COMPLIANCE WITH IRC SECT. R308 <br />EXCEPTIONS: NOT MORE THAN 50 PERCENT OF THE REQUIRED <br />AND WASHINGTON STATE SAFETY GLASS LAW. EXCEPTIONS <br />FLOOR AREA OF A ROOM OR SPACE IS PERMITTED TO HAVE <br />AS OUTLINED IN IRC SECT. R 308 <br />A SLOPED CEILING LESS THAN 7 FEET (2134 mm) IN HEIGHT <br />WITH NO PORTION OF THE REQUIRED FLOOR AREA LESS <br />15. <br />SAFETY GLAZING SHALL BE INSTALLED IN AREAS SUBJECT <br />THAN 5 FEET (1524 mm) IN HEIGHT. <br />TO HUMAN IMPACT ACCORDING TO .IBC SECTION 2406. <br />27. <br />LIGHT, VENTILATION AND HEATING: ALL HABITABLE ROOMS <br />SUCH HAZARDOUS LOCATIONS INCLUDE: <br />SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA OF NOT <br />A. <br />GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A <br />LESS THAN 4 PERCENT OF THE FLOOR AREA OF SUCH ROOMS. <br />DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING <br />SOURCE, AND WHEN PRIMARY POWER IS INTERRUPTED, <br />IS WITHIN A 24 INCH ARC OF EITHER VERTICAL EDGE OF <br />NATURAL VENTILATION SHALL BE THROUGH WINDOWS, DOORS, <br />THE DOOR IN A CLOSED POSITION AND THE BOTTOM <br />LOUVERS, OR OTHER APPROVED OPENINGS TO THE OUTDOOR <br />EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES <br />AIR. SUCH OPENINGS SHALL BE PROVIDED WITH READY ACCESS <br />ABOVE THE WALKING SURFACE EXCEPT WHEN THERE IS AN <br />OR SHALL OTHERWISE BE READILY CONTROLLABLE BY THE <br />INTERVENING WALL OR OTHER PERMANENT BARRIER <br />BUILDING OCCUPANTS. THE MINIMUM OPENABLE AREA TO THE <br />BETWEEN DOOR AND GLAZING. <br />OUTDOORS SHALL BE 4 PERCENT OF THE FLOOR AREA BEING <br />B. <br />GLAZING IN INGRESS OR EGRESS DOORS, EXCEPT <br />VENTILATED. IRC SEC. 303.1 AND WSEC <br />JALOUSIES. <br />EXCEPTIONS: <br />THE GLAZED AREAS NEED NOT BE OPENABLE WHERE THE <br />C. <br />GLAZING IN STORM DOORS. <br />OPENING IS NOT REQUIRED BY SECTION R310. <br />D. <br />GLAZING IN UNFRAMED SWINGING DOORS. <br />27.1 <br />PROVIDE A 120 CFM WHOLE OUSE FAN PER TABLE IRG4M+508, <br />E. <br />GLAZING IN DOORS AND WINDOWS FOR HOT TUBS, <br />OR WA. ST. AMEMNDMENTC(�5:08:3-, WHOLE HOUSE FAN SHA(f' HAVE A 24HR <br />WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATH TUBS, AND <br />CLOCK W/ PERMENANT FIXED LABELS SET PER THESE SECTIONS WITH A MAX. <br />SHOWERS. GLAZING IN ANY PORTION OF A BUILDING <br />SOME OF 1.0 Q .25 WATER GAUGE, PROVIDE A 4" SOLID METAL PIPE VENTED TO <br />WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM <br />THE EXTERIOR. <br />EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES <br />ABOVE A STANDING SURFACE AND DRAIN INLET. <br />28. <br />SECURITY FOR CRIMINAL ACTIVITY: BUILDING ENTRANCE <br />F. <br />GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL <br />DOORS INCLUDING GARAGE DOORS SHALL BE CAPABLE OF <br />LOCKING. THEY SHALL BE EQUIPPED WITH A DEAD -LOCKING <br />THAT MEETS ALL OF THE FOLLOWING CONDITIONS: <br />LATCH BOLT WITH AT LEAST A 1/2 INCH THROW WHICH PENETRATES <br />THE STRIKER NOT LESS THAN 1 /4 INCH. BUILDING ENTRANCE <br />- EXPOSED AREA OF AN INDIVIDUAL PANE GREATER <br />DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT USE ,-*----" <br />THAN NINE SQUARE FEET <br />OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. IRC SEC. 3 <br />- EXPOSED BOTTOM EDGE LESS THAN 18 INCHES ABOVE <br />29. <br />OBSERVATION PORTS: EVERY BUILDING ENTRANCE DOOR, <br />THE FLOOR <br />OTHER THAN GARAGE DOORS, SHALL HAVE A VISITOR OBSERVATION <br />PORT OR GLASS SIDE LIGHT. OBSERVATION PORTS SHALL BE <br />- EXPOSED TOP EDGE GREATER THAN 36 INCHES ABOVE <br />INSTALLED AT A HEIGHT OF NO LESS THAN 54 INCHES AND NO <br />THE FLOOR <br />MORE THAN66 INCHES FROM THE FLOOR. IRC SEC. 27> <br />- ONE OR MORE WALKING SURFACES WITHIN 36" <br />30. <br />WINDOWS AND SLIDING DOORS: DEAD BOLTS OR OTHER APPROVED <br />HORIZONTALLY OF THE PLANE OF THE GLAZING <br />OTHER LOCKING DEVICES SHALL BE PROVIDED ON ALL SLIDING <br />G. <br />GLAZING IN RAILINGS REGARDLESS OF HEIGHT ABOVE A <br />DOORS AND OPENABLE WINDOWS. IRC SEC. <br />WALKING SURFACE. <br />31. <br />GUARDRAILS SHALL BE PLACED AT ALL UNENCLOSED FLOOR <br />AND ROOF OPENINGS, LANDINGS, RAMPS, BALCONIES, <br />16. <br />EGRESS WINDOWS IN EVERY SLEEPING ROOM SHALL HAVE A <br />DECKS, OR PORCHES WHICH ARE MORE THAN 30 INCHES <br />MIN, NET CLEAR OPENING OF 5.7 SO, FT. THE MIN. <br />SHALL NOT BE LESS THAN 36 INCHES IN HEIGHT. <br />NET CLEAR OPENING HEIGHT DIMENSION SHALL BE 24" <br />GUARDRAILS SHALL HAVE INTERMEDIATE RAILS OR <br />MIN. NET CLEAR OPENING WIDTH DIMENSION OF 20", AND <br />ORNAMENTAL PATTERN WHICH WILL NOT ALLOW A 4" <br />A FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE THE <br />DIAMETER SPHERE TO PASS THROUGH. IRC SEC. R312 <br />FLOOR. SILL HT. LOWER THAN 24" REQUIRES FALL PROTECTION <br />WHEN WINDOW IS ABOVE 72 FROM GRADE. <br />32. <br />ONE HANDRAIL SHALL BE PROVIDED AT EVERY STAIRWAYS HAVING FOUR OR <br />MORE RISERS. PROVIDE 2 HANDRAILS WHERE INDICATED ON PLANS. THE TOP OF <br />1T ALL EXTERIOR WALL GLAZING SHALL BE DOUBLE GLAZED AND COMPLY <br />HANDRAILS SHALL BE PLACED NOT LESS THAN 34" NOR MORE THAN 38" ABOVE <br />WITH 2O15 WASHINGTON STATE ENERGY CODE. <br />THE NOSING OF TREADS. HANDGRIP PORTION OF HANDRAILS SHALL BE NOT <br />18. <br />PROVIDE A MINIMUM OF 22 GAUGE GALVANIZED STEEL <br />LESS THAN 1 1/2" NOR MORE THAN 2" IN CROSS SECTIONAL DIMENSION AND <br />FLASHING AT ALL ROOF/WALL INTERSECTIONS, <br />SHALL TERMINATE INTO WALLS OR NEWEL POSTS. IRC SEC, -R3i1-5:6-° 13.7 25 <br />ROOF/CHIMNEY INTERSECTION AND ROOF/SKYLIGHT CURBS. <br />33. <br />EXTERIOR STUD WALLS TO BE 2X6 STUDS AT <br />PROVIDE SAID FLASHING AT ALL HORIZONTAL <br />16" O.C. UNLESS NOTED OTHERWISE ON PLANS WITH R-21 <br />INTERRUPTIONS OF SIDING FINISHES. <br />DENSE CUT BATT INSULATION. INTERIOR STUD WALLS TO <br />BE 2X4 STUDS AT 16" O.C. UNLESS <br />19. EXTERIOR WOOD FRAMED DECKS AND OTHER WOOD FRAMED <br />INDICATED OTHERWISE ON PLANS. <br />STRUCTURES EXPOSED TO WEATHER: ALL WOOD SHALL BE <br />PRESSURE TREATED TO CURRENT AMERICAN WOOD <br />34 <br />ALL EXPOSED EXTERIOR 2X4 WALLS SHAL BE FILLED WITH R15 INSULATION ALL EXTERIOR <br />PRESERVERS INSTITUTE STANDARDS. THIS INCLUDES ALL <br />EXPOSED 2X6 WALL SHALL BE FILLED WITH R21 ALL "NEW" WINDOWS AND FENSTRATION <br />PLYWOOD, TRUSSES, SAWN MEMBERS, GLUE -LAMINATED <br />SHALL CONFORM TO THE INSULATION SCHEDULE <br />MEMBERS, ETC., UNLESS NOTED OTHERWISE. ALL NAILS <br />Mr) MKIM4 71'TOQQ QQAI I Or' FICA\/b (r)A,r r'As WAK117r'n <br />35. LEFT BLANK <br />36. SAFETY: CONTRACTOR SHALL BE RESPONSIBLE FOR ALL <br />REQUIRED SAFETY PRECAUTIONS AND THE <br />METHODS,TECHNIQUES, SEQUENCES, OR PROCEDURES REQUIRED <br />TO PERFORM THE WORK. <br />37. CHANGES: CONTRACTOR INITIATED CHANGES SHALL BE <br />SUBMITTED IN WRITING TO THE ARCHITECT AND <br />STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO <br />FABRICATION OR CONSTRUCTION, CHANGES SHOWN ON <br />SHOP DRAWINGS ONLY WILL NOT SATISFY THIS <br />REQUIREMENT. <br />38. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF <br />CONSTRUCTION. WHERE CONDITIONS ARE NOT <br />SPECIFICALLY INDICATED BUT ARE OF SIMILAR <br />CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF <br />CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND <br />APPROVAL BY THE ARCHITECT AND THE STRUCTURAL <br />ENGINEER. <br />39. ALL STRUCTURAL SYSTEMS SUCH AS WOOD TRUSSES WHICH <br />ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD <br />ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING <br />MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND <br />ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED <br />BY THE SUPPLIER. <br />40. THIS OFFICE ASSUMES NO RESPONSIBILITY AS TO THE <br />PHYSICAL CHARACTERISTICS OF THE SOIL. <br />41. SITE DRAINAGE TO CONFORM TO ALL LOCAL REGULATIONS <br />AND ORDINANCES. TIGHT LINE ALL ROOF DRAINS TO THE <br />STORM SEWER SYSTEM OR AN APPROVED DISCHARGE WHEN <br />STORM SEWERS ARE NOT AVAILABLE, DO NOT CONNECT <br />FOUNDATION AND RETAINING WALL PERIMETER AND <br />FOOTING DRAIN TIGHT LINE TO ROOF DRAIN TIGHT LINES <br />OR OTHER SITE DRAINAGE. FINISH GRADE AT THE <br />BUILDING FACE TO HAVE A POSITIVE SLOPE AWAY FROM <br />THE BUILDING. ALL SITE HARD SURFACES TO HAVE A <br />MINIMUM SLOPE OF 1/4":12" UNLESS NOTED OTHERWISE. <br />42. PROVIDE CONTINUOUS 4" ROUND PERFORATED PERIMETER <br />DRAIN IN GRAVEL FILL WITH FILTER FABRIC WRAP AT <br />ALL FOUNDATION WALLS. PROVIDE CLEAN OUTS SUCH <br />THAT ALL PORTIONS OF DRAINAGE SYSTEM CAN BE <br />ADEQUATELY CLEANED. LOCATE THE BOTTOM OF DRAIN <br />PIPE AT THE LOWEST POINT OF WALL FOOTING. TIGHT <br />LINE PERIMETER DRAIN TO STORM SEWER OR AN APPROVED <br />DISCHARGE WHEN STORM SEWERS ARE NOT AVAILABLE. DO <br />NOT CONNECT THE PERIMETER DRAIN TIGHT LINE TO ANY <br />OTHER TIGHT LINES OR SITE DRAINAGE SYSTEMS. <br />PROVIDE A MINIMUM OF 12" THICK CONTINUOUS LAYER OF <br />GRAVEL FILL FROM BOTTOM OF FOOTING TO WITHIN 12" <br />OF FINISH GRADE - TYPICAL AT ALL WALLS, APPROVED <br />GRAVEL FILL CONSISTS OF WASHED, CLEAN, FREE DRAINAGE <br />GRAVEL RANGING FROM 1 /4" TO 3/4" IN SIZE. <br />43. LEFT BLANK <br />44. PROVIDE WATER RESISTANT GWB GREEN BOARD OR <br />APPROVED SUBSTRATE BEHIND WET SURFACES <br />45. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL <br />WORK AND MATERIALS IN ACCORDANCE WITH ALL <br />APPLICABLE CODES AND ORDIANCES. GENERAL CONTRACTOR <br />SHALL BE RESPONSIBLE FOR <br />46. COORDINATING ALL WORK INCLUDING ADDITIONAL PERMITS <br />AND SUBCONTRACTOR WORK, <br />CONTRACTORD t BLOCKING FOR ALL WA <br />DISPENSERS,HUNG ITEMS (I.E. CABINETS, TOILET PAPER <br />MEDICINE <br />48. CONTRACTOR SHALL CLEAN ALL SURFACES PRIOR TO <br />OCCUPANCY OF RESIDENCE. <br />201 ��` HI GT N TAT' ENERGY CODE REQUIREMENTS <br />R401.3 POST !ENERGY COMPLIANCE CERTIFICATE WITHIN 3 FT. OF ELECTRICAL <br />PANEL AVAILABLE AT V1 .ENERGIY.VVSU.EDUYCODE <br />R402.4.1 PROVI,DIE DOOR BLOWER TEST AFFIDAVIT BY FINAL BUILDING INSPECTIONS, <br />R4i 03.1.11 PROVIDE ONE PROGRAMMABLE THERMOSTAT. <br />R403.2.2 PROVIDEDUCT SEALING AFFIDAVIT BY FINAL INSPECTION. <br />R404.1 A MIN. OF 75% OF ALL PERMANENTLY INSTALLED LIGHTING SHALL HAVE <br />HIGH EFFICACY LAMPS. <br />R402.`I.1 PROVIDE MIN. R-10 IRIGIID INSULATION AT HEADERS WHEN POSSIBLE <br />THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS. <br />CRITERIA <br />1. DESIGN IS 11\I ACCORDANCE WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE AS AMENDED BY CITY OF EVERETT <br />2. LIVE LOADS: <br />ROOF . . . . . . . . . . . . . . . . . . . . . . .25 PSF <br />FLOOR . . . . . . . . . . . . . . . . . . . . . 40 PSF <br />SNOW . . . . . . . . . . . . . . . . . . . . . . 25 PSF <br />DECK . . . . . . . . . . . . . . . . . . . . . . . 60 PSF <br />WIND . . . . . . . . . . . . . . . . . EXPOSURE "B" 110 MPH <br />SEISMIC. . . . . . . . . . . . . . . . . . . . . . . . . SITE CLASS "D" <br />3. FOUNDATIONS: <br />EXTEND FOOTINGS TO FIRM UNDISTURBED SOIL OR COMPACTED FILL. <br />ALLOWABLE SOIL BEARING 2500 PSL <br />EQUIVALENT FLUID PRESSURE = 40RF <br />4® CAST -IN -PLACE CONCRETE: (SPECIAL INSPECTION NOT REQUIRED) <br />F'C= 2500 PSI @ 28 DAYS. MINIMUM 5-1/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A MAXIMUM OF <br />6-3/4 GALLONS OF WATER PER 94,# SACK OF CEMENT. NO SPECIAL INSPECTION REQUIRED. MAXIMUM SIZED AGGREGATE IS 1-1/2 INCHES. <br />MAXIMUM SLUMP IS 4 INCHES. ALL PHASES OF WORK PERTAINING TO THE CONCRETE CONSTRUCTION SHALL CONFORM TO THE BUILDING CODE <br />REQUIREMENTS FOR REINFORCED CONCRETE. ALL REINFORCING STEEL DOWELS, ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN <br />POSITION PRIOR TO POURING CONCRETE, ANCHOR BOLTS FOR PRESSURE TREATED SILL PLATES TO FOUNDATION WALLS TO BE 5/8 INCH DIAMETER <br />WITH 7 INCH MINIMUM EMBEDMENT INTO CONCRETE AND MAXIMUM SPACING OF 2 FEET ON CENTER UNLESS NOTED OTHERWISE ON THE PLANS. <br />MINIMUM 2 BOLTS PER SILL PLATE PIECE, ONE BOLT TO BE PLACED WITHIN 12 INCHES OF EACH END OF THE SILL PLATE. <br />5. <br />01-Ty OF EVERETTPERMIT <br />ALL REINFORCING STEEL SHALL BE PLACED IN CONFORMANCE WITH THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE AND THE `IE FOR <br />MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION BY CRSI. DEFORMED REINFORCING STEEL BARS SHALL CONFORM TO <br />REINFORCING STEEL: 157PRE <br />HIITEOT <br />ASTM GRADE 40 FOR #5 AND SMALLER BARS ;AND GRADE 60 FOR 6 AND LARGER BARS. ALL REINFORCING BAR BENDS SHALL BE MADE COLD, WITI,,d-,�., <br />A MINIMUM RADIUS OF 6 BAR DIAMETERS (1 -o MINIMUM). CORNER BARS (2'-0 BEND) SHALL BE PROVIDED FOR ALL HORIZONTAL REINFORCEMENIT � <br />LAP ALL BARS A MINIMUM OF 48 BAR DIAMETERS UNLESS OTHERWISE. UNLESS OTHERWISE NOTED ON THE DRAWINGS REINFORCING STEEL SHALL <br />HAVE THE FOLLOWING MINIMUM COVER:. t -aaE7 <br />CONCRETE CAST AGAINST EARTH 3 INCHES `^sws sTF`atj <br />CONCRETE EXPOSED TO EARTH OR WEATHER: <br />6 THROUGH #18 BARS 2 INCHES <br />11R <br />#5 BAR AND SMALLER 1- 1/2 INCHES �ADI� �tG ' A,'\I;D DRAINAGE <br />CONCRETE NOT EXPOSED TO EARTH OR WEATHER: ` Provssio''ns shah .be made for -the control and drainage o"i surface <br />water aj-ounc] buildings g b, u��tters, drain lines, inlets Inc] catch <br />AND 18 BARS 1-1/2 INCHESwater <br />c atne:� nec4s,a,r•,� <br />11 BAR AND SMALLER 3/4 INCHES cl,ainage str ict�,:res and snail be ins-tal,l! <br />SLAB -ON -GRADE (FROM TOP SURFACE) 1-1/2 INCHES where storm water disPosal cannot be obtained without their use <br />EXPANSION AND EPDXY GROUTED ANCHORS: °vvhere eresian cannot be prevel" ecd b,; finish graclinc, and ^Iantln, <br />EXPANSION ANCHORS INTO CQNRETE SHALL BE WEDGE -ALL ANCHORS AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY INSTALLED IN <br />ACCORDANCE WITH THEIR RECOMMENDATIONS. EPDXY GROUTED ANCHORS SHALL BE INSTALLED USING "SET" EPDXY AS MANUFACTURED BY THE SIMPSON <br />STRONG TIE COMPANY. INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. ALTERNATE TYPE EXPANSION .AND <br />EPDXIED ANCHORS CAN BE SUBSTITUTED WITH APPROVAL OF OUR OFFICE. <br />ALL GRADES SHALL CONFORM TO WWPA GRADING RULES FOR WESTERN LUMBER, LATEST EDITION. PROVIDE CUT WASHERS UNDER ALL NUTS AND BOLTS <br />BEARING AGAINST WOOD. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED IN CONFORMANCE WITH I.R.C. SECTION R319.1. ALL <br />STRUCTURAL LUMBER SHALL BE NOTED BELOW: <br />S c 1nstallea in areas 4'�J�18rc^ sa19 �ls not �A'elrc <br />draln.ed a.nci.,)or Porous. <br />F G °dllg steal;E' provided d to lnsu"e'. <br />(a) Diversion of water av��ay ,1ro,n bulldingss <br />Ili) "`reventiO,9 of standing water and Sail sa-tUration dei,Ybment<-:,? <br />to St Uc�tures and lot use, <br />(oc) That natural drainage- olhanneas or basins are not lea r,'ad A.+r <br />ailed, <br />(d rov;s;ors for the calsposal of %,ate . f,", Iota <br />2X FLOOR & ROOF JOIST HEM -FIR #2 ....... ....... ....................................... Fb= 850 PSI E Protection n of a t,,i l,ng property <br />4X BEAMS DOUG-FIR/LARCH #2 .................. ................... Fb= 850 PSI <br />6X BEAMS DOUG-FIR LARCH #2 Fb= 850 PSI <br />COLUMNS DOUG-FIR/LARCH #2.....................................Fb= 850 PSI <br />LUMBER NOT NOTED DOUG-FIR/LARCH #2 ........... ...........Fb= 850 PSI .............. . <br />Root trusses to be des1qned <br />and drawing prepared by <br />MISCELLANEOUS HANGERS TO BE SIMPSON OR APPROVED EQUAL. ALL HANGERS SHALL BE FASTENED TO WOOD WITH PROPER NAILS. ALL HOLES SHALL B St to licensed struct0r„ <br />NAILED. MACHINE BOLTS TO BE A-307. ANCHOR BOLTS INTO CONCRETE SHALL BE 5/8 INCH DIAMETER WITH 7 INCHES OF EMBEDDMENT INTO CONCRETE engineer. <br />UNLESS NOTED OTHERWISE ON THE PLANS. ALL NAILS SHALL BE COMMON WIRE NAILS. NAILING SHALL CONFORM WITH I.R.C. TABLE R602.3c1) AN.D R802.1G" <br />OR I.B.C. TABLE 2304.9.1 FASTENERS INSTALLED IN PRESERVATIVE TREATED WOOD SHALL BE HOT DIPPED GALVANIZED PER I.R.C. SECTIO�N``Rarf94. <br />, <br />FLOOR SHEATHING: <br />SHEATHING SHALL BE 3 4 INCH TONGUE & GROOVE A.P.A. RATED SHEATHING SPAN RATING 48 24 WITH LONG DIMENSION IF BUI."DING IS NOT POS1TtO:�t D ,kS <br />PERPENDICULAR TO SUPPORTS. UNLESS NOTED OTHERWISE NAIL WITH 8d COMMON NAILS AT 6 INCHES ON CENTER AT SUPPORTED tI ?ICATED ON r"A-PPRO'4T:E.D SITE PLAN, <br />PANEL EDGES & 10 INCHES ON CENTER AT INTERMEDIATE SUPPORTS. THE FLOOR SHEATHING SHALL BE GLUED TO THE JOIST AND A 7NE r S :ate, PLAN SIETA L IS S DTI&-t-' <br />THE TONGUE AND GROOVE JOINTS WITH AN APPROVED ADHESIVE. TED. NO Tc R'T.-!E-R ITIiSPEC TTONS WILL <br />ROOF SHEATHING: WISED SITE PL ", HAS BEEIN PPROY- <br />SHEATHING SHALL BE 7/16 INCH A.P.A. RATED SHEATHING. SPAN RATING 32/16, INSTALLED WITH LONG DIMENSION ACROSS SUPPORTS. :D TT& <br />PERPENDICULAR TO SUPPORTS. UNLESS NOTED OTHERWISE NAIL WITH 8d COMMON NAILS AT 6 INCHES ON CENTER AT SUPPORTED <br />PANEL END JOINTS SHALL OCCUR AT SUPPORTS. NAIL PANEL EDGES WITH 8d NAILS AT 4 INCHES ON CENTER .AND 10 INCHES ON <br />at IS oilers reso;a;f iz) c5�k!I�? 5 <br />CENTER AT INTERMEDIATE SUPPORTS. <br />WALL SHEATHING: Additional Permits Are ReqUirSd <br />SHEATHING SHALL BE 7/16 INCH A.P.A. RATED SHEATHING. SPAN RATING 24/0. PANEL END JOINTS SHALL OCCUR AT SUPPORTS. For Thf 1'0JIt To InCIud . <br />NAIL PANEL EDGES WITH 8d NAILS AT 6 INCHES ON CENTER AND 10 INCHES ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED <br />OTHERWISE ON THE DRAWINGS. USE GALV. PRODUCTS @ ALL PRESSURE TREATED CONNECTIONS El PlumbingII prinMer <br />GLUE -LAMINATED TIMBER: Mechanical Fire Nam cl) <br />LAMINATED TIMBER SHALL BE DOUGLAS-FIR/ LARCH KILN DRIED. STRESS GRADE COMBINATION 24F-V4 (Fb=2400 PSI, Fv=225 PSI) OS, EeQtrjcaj <br />FORSIMPLE SPANS AND 24F-V8 FOR CANTILEVER AND CONTINUOUS BEAMS. A.I.T.C. CERTIFICATE OF CONFORMANCE REQUIRED. <br />GLU- LAMS SHALL CONFORM TO A.I.T.C. STANDARDS 117. FABRICATOR SHALL SUBMIT DETAILS AND SPECIFICATIONS TO THE ENGINEERCONCRETE-ENCASED ELECTRODE <br />0 <br />AND BUILDING DEPARTMENT FOR APPROVAL PRIOR TO FABRICATION GROUND)JUFER REQUIRED <br />PER NEC 250.30 <br />FLOOR FRAMING: (INSPEC70 A7 I TIII) <br />PROVIDE FULL DEPTH BLOCKING FOR JOIST AT THE SUPPORTS. FLUSH BEAMS (FB) AND HEADERS NOT CALLED OUT ON THE PLANS <br />SHALL BE (2) 2X10. ALL VERTICALLY LAMINATED BEAMS AND HEADERS SHALL BE SPIKED TOGETHER WITH 16d NAILS AT 6 INCHES ON Bencbmark Is Required On Site <br />CENTER. To VeTffy Approved Building HeIvIn! <br />BEARING WALL FRAMING: <br />c �sr <br />0, ANE TANKS, HEAT PIMPS AND <br />ALL DOOR AND WINDOW HEADERS NOT CALLED OUT ON THE PLANS SHALL BE (2) 2X8 DOUGLAS-FIR/LARCH 2 WITH ONE CRIPPLE OTI-I�� EQUIPMENT OR APPURTENANCES <br />AND ONE STUD EACH END FOR OPENINGS 4 FEET OR LESS AND TWO CRIPPLES AND ONE STUD FOR OPENINGS MORE THAN 4 FEET WIDE. Q,TH 9 OT S LOCATED IN THE TE AT <br />ALL COLUMNS NOT CALLED OUT ON THE PLANS SHALL BE (2) STUDS. SPIKE LAMINATED COLUMNS TOGETHER WITH 16d NAILS AAY OT ELOC TE PROPANE TANKS <br />AT `I2 INCHES ON CENTER. PROVIDE TWO LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER AT CONTACT SURFACES BETWEEN MQ SIDI A DIB'ION,A, PERMITS IC ED <br />WOOD AND CONCRETE. WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATES AND BOTTOM RETUI EVERETT MIRE DEPAP, NT <br />PLATES TO EACH STUD WITH 2-16d NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16d NAILS AT 10 INCHES ON CENTER. LAP AND FACE 9_-A1L19 TO INSTAL4A ION. <br />PLATES WITH 2-16d MAILS AT EACH SPLICE, CORNER INTERSECTION. STAGGER SPLICES A MINIMUM OF 48 INCHES. FACE NAIL BOTTOM <br />PLATE TO WITH 2-16d NAILS. <br />PRE -MANUFACTURED FLOOR JOIST: <br />JOIST SHALL BE MANUFACTURED IN A PLANT APPROVED FOR FABRICATION BY THE BUILDING DEPARTMENT AND UNDER THE SUPERVISION <br />N,I I <br />OF AN APPROVED THIRD PARTY INSPECTION AGENCY. EACH JOIST SHALL BE IDENTIFIED BY A STAMP INDICATING THE JOIST TYPE <br />CABO NER REPORT NUMBER, MANUFACTURERS NAME, PLANT NUMBER AND THE INDEPENDENT INSPECTION AGENCY LOGO r =1 <br />t i a� 91 <br />AND EVALUATION REPORT NUMBER. 0 ��1 � , �I <br />PRE -MANUFACTURED ROOF TRUSSES: <br />R ' ' <br />TRUSSES SHALL BE PLANT FABRICATED OF DOUGLAS--FIRAARCH OR HEM -FIR. TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS <br />Permit#: <br />C1804-005 <br />OF AN APPROVED THIRD PARTY INSPECTION AGENCY. EACH JOIST SHALL BE IDENTIFIED BY A STAMP INDICATING THE JOIST TYPE <br />Site Address: <br />6223 KENWOOD DR <br />AND CALCULATIONS STAMPED, SIGNED AND DATED BY A WASHINGTON STATE LICENSED STRUCTURAL ENGINEER, ALL TRUSS PLATES <br />Owner: <br />@AZEOLLAANTHONY <br />AND CONNECTORS SHALL BE I.C.B.O. APPROVED VERIFY MECHANICAL UNIT LOADS AND LOCATIONS WITH SUPPLIER AND FURNISH <br />Tenant: <br />ADDITIONAL TRUSSES AS REQUIRED. SUBMIT TRUSS DRAWING TO THE ENGINEER OF RECORD AND BUILDING DEPARTMENT FOR <br />App. Date: <br />9/24/2 <br />9/24/20181� <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />���� � <br />�� a <br />Proposed Use: <br />SEF� DETACHED <br />SPECIAL CONDITIONS: <br />! ��?� �r�,�'aE�D <br />FOR P `RPv ,7., <br />Ali �ul �I <br />Description: <br />�9E19i9SERDETA�HED <br />THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ALL DISCREPANCIES SHALL BE REPORTED TO THE <br />ARCHITECT OR ENGINEER. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AS REQUIRED UNTIL PERMANENT CONNECTIONS <br />,I <br />Reviewed By: <br />,9 <br />' f <br />Dater 11::11 � <br />AND STIFFENINGS HAVE BEEN INSTALLED. THE CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL OPENING IN THE FLOOR <br />a9fOfficeSet <br />TobSiteSet <br />Fire/Planning Set <br />ROOF, AND WALLS WITH ALL THE APPROPRIATE DRAWINGS. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING DEPARTMENT <br />FOR ALL BLDG. DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE THE DRAWINGS. THE DETAILS SHOWN ARE TYPICAL AND SHALL <br />BE USED FOR LIKE OR SIMILAR CONDITIONS NOT SHOWN. PRE -FABRICATED ITEMS TO BE HANDLED AND INSTALLED PER MANUFACTURERS <br />RECOMMENDATIONS. <br />