Laserfiche WebLink
1. ALL STRUCTURAL WOOD SMALL CONFORM WITH THE LATEST EDITION OF THE FOLLOWING <br />SPECIFICATIONS: <br />A. HEMLOCK FIR ...... ..........................WWPA GRADING RULES-05. STRESS VALUES SHOWN IN NOTE #2 <br />EASE MEMBER VALUES. <br />B. STOCK GLULAM BEAMS..................PRG-305 PERFORMANCE STANDARD FOR APA EWS STOCK GLULAM <br />BEAM <br />C. NON -STOCK GLULAM BEAMS.... ..... ANSI/AITC STANDARD A190.1 FOR STRUCTURAL GLUED LAMINATED <br />TIMBER <br />D. STRUCTURAL PLYWOOD ................ALL PANELS TO BE PLYWOOD OF MINIMUM 5 PLY CONSTRUCTION. <br />EACH PANEL SHALL BEAR THE QUALITY TRADEMARK STAMP OF THE "APA - THE ENGINEERED WOOD <br />ASSOCIATION". <br />E. ORIENTED STRAND BOARD ...........ALL PANELS TO BE ORIENTED STRAND BOARD. EACH PANEL SHALL <br />BEAR THE QUALITY TRADEMARK SWAMP OF THE " APA - THE ENGINEERED WOOD ASSOCIATION <br />2. ALL LUMBER SHALL BE HEMLOCK FIR WITH A MOISTURE CONTENT OF 19% OR LESS AT THE TIME <br />OF INSTALLATION. MINIMUM GRADE SHALL BE: <br />4X - HEMLOCK FIR 2, Fb = 850 PSI <br />2X - HEMLOCK FIR 2, Fb = 850 PSI <br />PARALLAM PSL - 2.2E TRUSJOIST PARALLAM <br />PREFABRICATED WOOD I -JOISTS - WEYERHEUSER TRUSS JOIST TJI JOISTS <br />® STOCK GLULAM BEAMS - 1.9E ROSOBORO X-BEAM. UNBALANCED AT SINGLE SPAN AND BALANCED <br />AT CONTINUOUS OR CANTILEVERED SPANS. <br />NON -STOCK GLULAM BEAMS - SIMPLE SPAN 24F-V4. CONTINUOUS SPAN 24F-V8. CAMBER MINIMUM <br />3500-FT RADIUS, LION. <br />STRUCTURAL PLYWOOD - APA C-D EXTERIOR GLUE. <br />3. BEADING AND SHEAR WALLS SHALL HAVE DOUBLE TOP PLATES, LAPPED AT WALL AND PARTITION <br />INTERSECTIONS WITH 3-16d NAILS. SPLICE UPPER AND LOWER PLATES AS IN DETAIL ON THIS SHEET. <br />TOP OR BOTTOM PLATES WHEN BORED FOR PIPES AND CONDUITS SHALL BE SPLICED WITH SIMPSON ST <br />6236 STRAPS ON ONE SIDE WHEN NOTCH IS 1/3 THE WIDTH OF THE PLATES. WHEN THE HOLE IS 2/3 OF <br />THE WIDTH OF THE PLATES USE SIMPSON ST 6236 STRAPS ON EACH SIDE OF THE PLATES. BORED <br />HOLES SHALL BE CENTERED ALONG THE WIDTH OF PLATES. NOTCHING PLATES MORE THAN 9 OF THE <br />WIDTH IS NOT ALLOWED. NOTCHES IN PLATES SHALL SHALL NOT BE LONGER THAN THE PLATE WIDTH <br />AND SHALL HAVE A CLEAR DISTANCE BETWEEN ANY ADJACENT HOLE OR NOTCH OF AT LEAST TWICE <br />THE PLATE WIDTH. SILL PLATES SHALL BE PLACED IN A BED OF GROUT WHEN REQUIRED FOR FULL <br />BEARING ON THE FOUNDATION. <br />4. FOR EXTERIOR AND BEARING STUDS, NOTCHING NOT TO EXCEED 25% OF WIDTH AND BORED HOLES <br />NOT TO EXCEED 40% OF WIDTH. FOR NON -BEARING STUDS, NOTCHING NOT TO EXCEED 40% AND <br />BORING NOT TO EXCEED 60%. IF EXCEEDED, PROVIDE SIMPSON HSS STUD SHOE. <br />5. PROVIDE SOLID BLOCKING BETWEEN JOISTS OR RAFTERS AT ALL SUPPORTS, AND AT SUPPORTS <br />PARALLEL TO THE FRAMING PROVIDE BLOCKING OVER SUPPORT AT THE SAME SPACING AS THE <br />FRAMING. PROVIDE CROSS BRIDGING OR FULL DEPTH BLOCKING FOR ALL ROOF RAFTERS OR FLOOR <br />JOISTS THAT ARE 8 1/4 OR MORE INCHES DEEP, AT 8 FEET ON CENTER MAXIMUM AND AT NOT MORE <br />THAN 10 FEET FROM SUPPORTS. CROSS BRIDGING SHALL CONSIST OF 2X3 WITH 2-8d TOE NAILS AT <br />EACH END OR METAL BRIDGING INSTALLED WITH 2-8d NAILS AT EACH END. <br />6. JOISTS UNDER AND PARALLEL TO PARTITIONS SMALL BE DOUBLED AND STITCH NAILED TOGETHER. <br />7. PROVIDE BLOCKING IN ALL WALLS AT THE MID HEIGHT OF STUDS OR SO SPACED THAT THE UNBRACED <br />LENGTH OF STUDS DOES NOT EXCEED 10 FEET. PROVIDE BLOCKING IN WALLS AT CEILING LINES. <br />8. PROVIDE SOLID BLOCKING BETWEEN ANY POSTS AT FLOOR FRAMING IN MULTI -STORY CONSTRUCTION. <br />9. ALL WOOD FRAMING MEMBERS SHALL EITHER BEAR ON PLATES, BEAMS, POSTS OR BE SUPPORTED IN A <br />METAL CONNECTOR. <br />10. ALL LIGHT GAGE METAL CONNECTORS FOR WOOD CONSTRUCTION SHALL BE SIMPSON "STRONG -TIE" <br />PRODUCTS AS SPECIFIED IN THEIR LATEST CATALOG OR AN APPROVED EQUAL. INSTALL ALL <br />CONNECTORS PER MANUFACTURERS REQUIREMENTS, UON. <br />11. HOLES FOR BOLTS IN WOOD SHALL BE BORED WITH A BIT OF THE SAME NOMINAL DIAMETER AS THE <br />BOLT PLUS 1116TH OF AN INCH. HOLES FOR LAG SCREWS SHALL BE BORED AT NO MORE THAN 75% OF <br />THE DIAMETER OF THE ROOT OF THE THREADS. <br />12. ALL BOLTS, EXPANSION ANCHORS AND LAG SCREWS SHALL BE PROVIDED WITH METAL WASHERS <br />UNDER THE HEADS AND NUTS WHICH BEAR ON WOOD. <br />13. LAG SCREWS AND WOOD SCREWS SHALL BE SCREWED AND NOT DRIVEN INTO PLACE. ALL BOLTS AND <br />LAG SCREWS SHALL BE TIGHTENED ON INSTALLATION AND RETIGHTENED BEFORE CLOSING IN OR <br />COMPLETION OF THE JOB. <br />14. ALL GLULAM BEAM FABRICATION SHALL BE PERFORMED BY AN APPROVED FABRICATOR PER IBC <br />1704.2.5.1. <br />15. WOOD FRAMING MEMBERS THAT REST ON EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" FROM <br />EXPOSED EARTH SHALL BE OF (NATURALLY DURABLE OR PRESERVATIVE -TREATED PER IRO R317.1. <br />16. CLEARANCE BETWEEN WOOD SIDING, SHEATHING AND FRAMING ON THE EXTERIOR OF A BUILDING AND <br />EARTH SHALL NOT BE LESS THAN 6" FROM THE GROUND AND 2°" VERTICALLY FROM CONCRETE STEPS, <br />PORCH SLABS, ETC. EXCEPT WHERE SIDING, SHEATHING AND WALL FRAMING ARE OF NATURALLY <br />DURABLE OR PRESERVATIVE -TREATED WOOD PER IRC R317.1. <br />fil <br />f9F <br />�D <br />�B <br />0 <br />ev <br />I <br />es <br />c <br />®I <br />r <br />CD <br />0) <br />N <br />U <br />c <br />0 <br />E <br />0 <br />u <br />cr <br />2 <br />r <br />W <br />IL <br />1. ALL POWER (PNEUMATIC) DRIVEN NAILS FOR STRUCTURAL WORTS SMALL BE <br />SMOOTH -NAILS (UNLESS SPECIFICALLY NOTED OTHERWISE) PER ASTM 1667. <br />2. ALL POWER DRIVEN NAILS FOR STRUCTURAL WORK SHALL CONFORM WITH ICC <br />ESR-1539. <br />3. NAILS INSTALLED IN PRESERVATIVE LUMBER SHALL BE HOT -DIP GALVANIZED <br />NAILS CONFORMING WITH ASTM A 153, <br />4. NAILS EXPOSED TO WEATHER SHALL BE CORROSION RESISTANT. <br />5. NAILS SHALL BE SPACED AT NOT LESS THAN 11 DIAMETERS ON CENTER. EDGE <br />AND END DISTANCES SHALL NOT BE LESS THAN 6 DIAMETERS. NAIL HOLES <br />SHALL BE SUE -DRILLED WHERE NECESSARY TO PREVENT SPLITTING OF WOOD. <br />6. ALL FAILS FOR PLYWOOD SHEATHING SHALL MEET 8d COMMON NAIL SLING <br />(2 1 /2"°X0. 1 31 "0) <br />F. NAILING NOT NOTED BELOW OR INDICATED ON THE PLANS SHALL BE A MINIMUM <br />OF TWO 16d NAILS AT EACH CONTACT FOR 2X MEMBERS AND A MINIMUM OF <br />TWO 8d NAILS AT EACH CONTACT FOR 1X MEMBERS. <br />8. MINIMUM NAILING SHALL BE PER THE TABLE BELOW. CONNECTIONS NOT NOTED <br />BELOW SHALL BE PER ICC ESR-1539 TABLE 11: <br />ITEM <br />DESCRIPTION OF BUILDING ELEMENT <br />NUMBER/SPACING @TYPE <br />OF FASTENER <br />ROOF <br />1 <br />BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TN <br />(3) 16d (3"°x0.131 <br />(3) 8d (2 1/2"x0.131 <br />2 <br />CEILING JOISTS TO PLATE, TOE NAIL <br />(3) 16d (3°"0.131") <br />(3) 8d (2 1 /2"x0.131 <br />3 <br />CEILING JOISTS NOT ATTACHED TO PARALLEL RAFTER" LAPS <br />(4) 16d (3"°x0.131 <br />OVER PARTITIONS, FACE NAIL <br />4 <br />COLLAR TIE TO RAFTER, FACE NAIL OR 1 1/4"x20 GAGE RIDGE <br />(4) 16d (3"x0.131 <br />STRAP <br />(5) 8d (2 1/2"x0.131 <br />5 <br />RAFTER OR ROOF TRUSS TO PLATE, TOE NAIL <br />(4) 16d (3"x0.131") <br />(5) 8d (21/22'0.131"°) <br />6 <br />ROOF RAFTER TO RIDGE, VALLEY OR HIP RAFTERS: TOE NAIL <br />(5) 16d (3"x0.131°") <br />(5) 8d (2 1/2" 0.131") <br />7 <br />ROOF RAFTER TO RIDGE, VALLEY OR HIP RAFTERS: END NAIL <br />(4) 16d (3"x0.131 <br />WALL <br />8 <br />BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TN <br />16d (3"00.131") @ 16°" OC <br />8d (2 1/2°"x0.131") @ 8" OC <br />9 <br />ABUTTING STUDS AT INTERSECTING WALL CORNERS, FACE NAIL <br />16d (3"°0.131") @ 8" OC <br />8d (2 1/2"x0.131") @ 8" OC <br />10 <br />BUILT-UP HEADER, TWO PIECES WITH 1/2" SPACER <br />16d (3°"0.131°") @ 8" OC <br />11 <br />CONTINUOUS HEADER TO STUD, TOE NAIL <br />(4) 16d (3"x6.131")® <br />(4) 8d (2 1/2"x0.131 ) <br />12 <br />DOUBLE TOP PLATES, FACE NAIL <br />16d (3"x0.131°") @ 12"° OC <br />8d (2 1 /2"°x0.131 ") @ 8" OC <br />13 <br />DOUBLE TOP PLATES, MINIMUM 48-INCH OFFSET OF END JOINTS, <br />(16) 16d (3"x0.131 <br />FACE NAIL IN LAPPED AREA <br />14 <br />TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS, FACE NAIL <br />(3) 16d (3"x0.131 <br />15 <br />SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL <br />16d (3"00.131") @ 12" OC <br />8d (2 1/2"x0.131"') @ 8" OC <br />16 <br />SOLE PLATE TO JOIST OR BLOCKING AT BRACED WALL PANELS <br />(4) 16d (3"x0.131°") @ 16" OC <br />(4) 8d (2 1/2"°x0.131") @ 16" OC <br />17 <br />TOP OR SOLE PLATE TO STUD, END NAIL <br />(4) 16d (3"x0.131"°) <br />(4) 8d (2 1/2"0.131") <br />18 <br />STUD TO SOLE PLATE, TOE NAIL <br />(4) 16d (3"x0.131")" <br />(4) 8d (2 1/2 x0.131 ) <br />FLOOR <br />19 <br />JOIST TO SILL OR GIRDER, TOE NAIL <br />3-16d (3"x0.131 ") <br />3-8d (2 1/2"x0.131") <br />20 <br />RIM JOIST TO TOP PLATE, TOE NAIL <br />16d (3"0.131") @ 6" OC <br />8d (2 1/2"x0.131") @ 6" OC <br />21 <br />BUILT-UP GIRDERS AND BEAMS, ):INCH LUMBER LAYERS <br />16d (3"x0.131") @ 24" OC <br />22 <br />LEDGER STRIP SUPPORTING JOISTS OR RAFTERS <br />5-16d (3"x0.131°") <br />6-8d (2 1/2"0.131") <br />HAND DRIVEN NAILING NOTES: <br />1. ALL HAND DRIVEN NAILS FOR STRUCTURAL WORK SHALL BE SMOOTH -COMMON NAILS <br />(UNLESS SPECIFICALLY NOTED OTHERWISE) PER ASTM 1667. <br />2. NAILS INSTALLED IN PRESERVATIVE LUMBER SHALL BE HOT -DIP GALVANIZED NAILS <br />CONFORMING WITH ASTM A 153. <br />3. NAILS EXPOSED TO WEATHER SHALL BE CORROSION RESISTANT. <br />4. NAILS SHALL BE SPACED AT NOT LESS THAN 11 DIAMETERS ON CENTER. EDGE AND END <br />DISTANCES SHALL NOT BE LESS THAN B DIAMETERS. NAIL HOLES SHALL BE SUB - <br />DRILLED WHERE NECESSARY TO PREVENT SPLITT➢NG OF WOOD. <br />5. NAILING NOT NOTED BELOW OR INDICATED ON THE PLANS SHALL BE A MINIMUM OF <br />TWO 10D NAILS AT EACH CONTACT FOR 2X MEMBERS AND A MINIMUM OF TWO 8d NAILS <br />AT EACH CONTACT FOR 1X MEMBERS. <br />6. MINIMUM NAILING SHALL BE PER THE TABLE BELOW. CONNECTIONS NOT NOTED BELOW <br />SHALL BE PER IRO TABLE R602.3(1): <br />ITEM <br />DESCRIPTION OF BUILDING ELEMENT <br />NUMBER/SPACING @ <br />TYPE OF FASTENER <br />ROOF <br />1 <br />BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, <br />(3) 8d (2 1/2")(0.131"), OR <br />TOE NAIL <br />(3) 3"x0.131"° <br />2 <br />CEILING JOISTS TO PLATE, TOE NAIL <br />(3) 8d (2 1/2"x0.131"), OR <br />(3) 3"x0.131 " <br />3 <br />CEILING JOISTS NOT ATTACHED TO PARALLEL RAFTER, LAPS <br />(3) 16d (3 1/2"0.162"), OR <br />OVER PARTITIONS, FACE NAIL <br />(4) 3"x0.131" <br />5 <br />COLLAR TIE TO RAFTER, FACE NAIL OR 1 1/4"x20GA RIDGE <br />(3) 10d (3°"x0.148"), OR <br />STRAP, FACE NAIL <br />(4) 3""x0.131" <br />6 <br />`_ <br />RAFTER OR ROOF TRUSS TO PLATE, TOE NAIL <br />(3) 10d (2 1/2"x0.148"), OR <br />(4) 3"°0.131 "° <br />(3) 10d (3 1/2"00.148") <br />7 <br />ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS OR ROOF <br />(4) 3"00.131" <br />(2) 16d (3 1/2"x0.162°") <br />RAFTER TO MINIMUM 2" RIDGE BEAM (TOE NAIL/FACE NAIL) <br />(3) 3"x0.131 " <br />WALL <br />8 <br />STUD TO STUD (NOT AT BRACED WALL PANELS), FACE NAIL <br />16d (3 1/2"00.162") @ 24" OC <br />3c"x0.131 " @ 16" OC <br />9 <br />STUD TO STUD AND ABUTTING STUDS AT INTERSECTION <br />16d (3 1/2"x0.162"°) @ 16°" OC <br />WALLCORNERS AT BRACED WALL PANELS), FACE NAIL <br />3"x0.131°" @ 12°" OC <br />10 <br />BUILT-UP HEADER (2" TO 2°" HEADER W/ 1/2"° SPACER), FACE NAIL <br />16d (3 1/2"x0.162") @ 16"" OC <br />16d (3 1/2"00.135"") @ 12" OC <br />11 <br />CONTINUOUS HEADER TO STUD, TOE NAIL <br />(4) 8d (2 1/2"x0.131"), ®R <br />(4) 10d (3"x0.128") <br />12 <br />TOP PLATE TO TOP PLATE, FACE NAIL <br />16d (3 1/2"00.162") @ 16°" OC <br />3"x0.131 °" @ 12" OC <br />13 <br />DOUBLE TOP PLATE SPLICE, MINIMUM 48-INCH OFFSET OF END <br />(16) 16d (3 1/2"x0.135"°) <br />JOINTS, FACE NAIL IN LAPPED AREA <br />(16) 3"x0.131") <br />14 <br />BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING <br />16d (3 1/2"x0.162") @ 16"° OC <br />(NOT AT BRACED WALL PANELS), FACE NAIL <br />3"x0.131"@ 12"OC <br />15 <br />BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING <br />(2) 16d (3 1/2"00.162"°) @ 16"° OC <br />(AT BRACED WALL PANELS), FACE NAIL <br />(4) 3"x0:131" @ 16" OC <br />(4) 8d (2 1/2"0.131 <br />16 <br />4) 3"°0.131" <br />TOP OR BOTTOM PLATE TO STUD (TOE NAIL/END NAIL) <br />(2) 16d (3 1/2")(0.162") <br />(3) 3"00.131 " <br />17 <br />TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS, FACE NAIL <br />(2) 16d (3 1/2"x0.162") <br />3 3"0.131 <br />FLOOR <br />21 <br />JOIST TO SILL, TOP PLATE OR GIRDER, TOE NAIL <br />(3) 8d(2 1/2"00.131") <br />(3) 3"0.131 °" <br />22 <br />RIM JOIST, BALD JOIST OR BLOCKING TO SILL OR TOP PLATE, TN <br />8d (2 1/2"0.131") @ 6"° OC <br />3"x0.131 "@ 6"OC <br />24 <br />2" SUBFLOOR TO JOIST OR GIRDER, BLIND AND FACE NAIL <br />(3) 16d (3 1/2"°x0.135") <br />(2) 16d (3 1/2"xO. 162") <br />26 <br />BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER, FACF NAIL <br />(3) 16d (3 1/2"0.162") <br />(4) X'x0.131" <br />27 <br />LEDGER STRIP SUPPORTING JOISTS OR RAFTERS, FACE NAIL EA <br />1Od (3"x0.128"") OR 3"x0.131 <br />JST <br />@ 24°" OC T&B & 3 EA END <br />28 <br />BAND OR RIM JOIST TO JOIST" END NAIL <br />(3) 16d (3 1/70.162") <br />(4) `g""x0.131"" <br />29 <br />BRIDGING TO JOIST <br />(2) 10dJ(3"x0.128") <br />WOOD STRUCTURAL PANELS, SUBFLOOR, ROOF AND INTERIOR WALL SHEATHING <br />32 <br />3/8" to 1/2" (EDGE (NAILING/FIELD NAILING) <br />8d (2 1/2"00.131") @ 6°" OC <br />8d (2 1/2°0.131") @ 12"° OC <br />33 <br />19/32" TO 1" (EDGE NAILING/FIELD <br />8d (2 1/2"x0.131") @ 6" OC <br />8d (2 1/2"x0.131") @ 12"° OC <br />34 <br />1 1/8" to 1 1/4" (EDGE NAILING/FIELD NAILING) <br />10d (3"x0.148") @ 6" OC <br />10d (3"x0.148") @ 12" OC <br />V9T <br />REVIEWED FOR PERNT <br />