My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3506 ROCKEFELLER AVE 2020 Plans 2022-12-01
>
Address Records
>
ROCKEFELLER AVE
>
3506
>
Plans
>
3506 ROCKEFELLER AVE 2020 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 8:23:03 AM
Creation date
12/14/2021 2:11:45 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3506
Permit
CW2008-002
Year
2020
Notes
Complete repair/restoration/re-roof from fire damage
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(HANDRAIL DRIP SIZE PER <br />IRC 1111z.) <br />1 1/4" DIA. MIN, <br />HANDRAIL, CONT. <br />FOR FULL LENGTH <br />OF STAIR ZA <br />SPACING 5ETWEEN INTERMEDIATE <br />GUARDRAIL MEM5 RS TO 5E SUCH <br />THAT A SPHERE OF 4" DIA. SHALL NOT <br />PASS THROUGH ANY OPENINGS <br />HANI:>RAIL6 PER <br />IRC R311.i1a <br />5ALU5TER5 TO CONFORM <br />TO IRC R312.3 <br />3ro" MIN. STAIRWAY WIDTH <br />PER IRC 11,1.1 =-- <br />DOU5LE MMR <br />1/2" G.W.5. UNDER ALL <br />STAIRS w0 USA5LE SPACE <br />3) 2X12 STRINGERS <br />FIRE 5LOCKING MID SPAN <br />ALL WiNPOLUSTO 5E R u <br />UNITS O 5wl ELECTWC 1 ;* Syy <br />WALLS SMALL 5E WATERPROOFED TO A MIN. OF 12" ABOVE THE DRAIN <br />INLET. <br />- ALL GLAZING INCLUDING WINDOWS WITHIN r-o0" OF DRAIN <br />INLET TO 5E SAFETY CLASS. <br />.ALL SHOWERHEAD5 AND KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE <br />SHALL 5E RATED AT 1.15 G.P.M. OR LESS. ALL OTHER LAVATORY FAUCETS <br />SMALL 5E RATED AT 1.0 C.P.M. <br />I. IN CONCEALED SPACES OF STUD FALLS AND PARTITIONS, <br />INCLUDING FURRED SPACES AND PARALLEL ROWS OF 5TUD5 <br />OR STAGGERED STUDS AS FOLLOWS: <br />I.I. VERTICALLY AT THE CEILING AND FLOOR LEVELS. <br />1.2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET <br />2. AT ALL INTER CONNECTIONS 15ETLUEEN CONCEALED VERTICAL <br />AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP <br />CEILINGS AND COVE CEILINGS. <br />3. IN CONCEALED SPACES 5ETWEEN STAIR STRINGERS AT THE TOP <br />AND IBOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL <br />COMPLY WITH SEDCTION R311.2.2. <br />4. AT OPENINGS AROUND VENTS, PIPES, AND DUCTS AT CEILING AND <br />FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RE51ST THE FREE <br />PASSAGE OF FLAME$ AND PRODUCTS OF COM U5TION. <br />5. FOR THE FIRE5LOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION <br />R100.1ro. <br />ro. FIRE5LOCKING OF CORNICES OF A TWO-FAMILY DWELLING IS REQUIRED <br />AT THE LINE OF DWELLING UNIT SEPARATION. <br />1. PROVIDE SQUASH 5LOCKS UNDER ALL POSTS a SHEARWALL5 <br />POSTS • w. <br />R. ARE EXISTING <br />TYPICAL PLATE 15 i'-11"t <br />TOP OF WINDOWS TO 5E Q &'-10" i <br />- ALL EXISTING EXTERIOR WALLS ARE 2x4 a 1611 O.C. <br />- ALL EXTERIOR WALLS TO 5E INSULATED w/ R-21 INSULATION <br />DENOTES DOU LE TRIMMERS AT EACH END OF HEADER <br />THAT SPANS &'-0" OR GREATER <br />® DENOTES MULTIPLE STUDS UNDER POINT LOADS <br />SEE PLAN FOR NUM5ER OF STUDS REQUIRED <br />5D/CMD - SMOKE DETECTOR AND CAR50N MONOXIDE DETECTOR <br />TO 5E HOT WIRED AND INTERCONNECTED w0 5ATTERY 5ACKUP <br />ALL SMOKE DETECTORS TO 5E HOT WIRED AND INTERCONNECTED <br />w/ 5ATTERY 5ACKUP <br />m 51-IOKE DETECTOR TO 5E ON THE CEILING INSIDE THE DOOR <br />OF EACH 5EDROOM <br />® SMOKE ALARMS TO 5E AUD15LE IN ALL 5EDR00M5 AND SLEEPING AREA5. <br />ALL WINDOWS WITHIN 15" OF THE FLOOR OR WITHIN 24" OF DOOR SWINGS, <br />TU58, AND SHOWERS, TO 5E TEMPERED SAFETY GLASS. <br />- VENT ALL FANS 4 DRYER EXAUST TO OUTSIDE <br />PROVIDE EGRESS WINDOWS IN ALL SLEEPING ROOMS <br />GUARDS TO EBE PROVIDED AT ALL PORGIES, 5ALCONI S, OR RAISED <br />FLOORS MORE T HAT 30" A50VE THE FLOOR OR GRADE PER IRC R312. <br />MINIMUM HEIGHT 15 3P " (3.4" AT STAIRS) AND OPEN SIDES MUST HAVE <br />INTERMEDIATE RAILS OR ORNAMENTATION THAT WILL NOT ALLOW PASSAGE <br />OF A SPHERE 4" OR MORE IN DIAMETER. <br />- WATER HEATER PER Si NAECA, <br />WATER HEATER 4 FURNACE TO 5E STRAPPED 4 <br />5OLTED TO RESIST SEI5MIC MOVEMENT. USE U.L. APPROVED <br />STRAPPING MATERIAL 4 METHODS. <br />- HEAT ELEMrzNTS TO IBE 15" A50VE CONCRETE SLA5. <br />