My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2902 RUCKER AVE 2020 FAST SIGNS Plans 2022-10-28
>
Address Records
>
RUCKER AVE
>
2902
>
FAST SIGNS
>
Plans
>
2902 RUCKER AVE 2020 FAST SIGNS Plans 2022-10-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2022 2:16:09 PM
Creation date
12/14/2021 2:30:18 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2902
Tenant Name
FAST SIGNS
Permit
B2010-013
Year
2020
Notes
Minor demo, mod partition walls, add loading dock
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- Permit #: <br />Site Address: <br />213®7_ RUCKER AVE <br />Cvvner: <br />DMT RUCKER LLC <br />Tenant: <br />FAST SIGNS LLC <br />BUILDING CODE SUMMARY <br />2015 IEBC: <br />OCCUPANCY GROUP B: 16,175SF <br />ZONING CODE SUMMARY <br />PRESCRIPTIVE COMPLIANCE, CH. 4 <br />2015 IBC: <br />2015 WA ENERGY CODE: <br />REFER TO BUILDING PERMIT #B-2003-0413 FOR ALLOWABLE ARE <br />EXITING: SEE EGRESS PLAN A6 FOR EXITING LOADS AND ANAL( <br />CHAPTER 19.19 (UM ZONE) <br />BUSINESS SERVICE - PERMITTED USE <br />CHAPTER 19.34.050 <br />GENERAL NOTES AND SPECIFICATIONS <br />1. MEANS & METHODS: THE ARCHITECT IS NOT RESPONSIBLE FOR CONSTRUCTION <br />MEANS AND METHODS, ACTS OR OMISSIONS OF THE CONTRACTOR OR IT'S <br />SUBCONTRACTORS, OR FAILURE OF ANY OF THEM TO CARRY OUT WORK IN <br />ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. ANY DEFECT DISCOVERED IN <br />THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE <br />ARCHITECT BEFORE PROCEEDING WITH WORK. REASONABLE TIME NOTALLOWED THE <br />ARCHITECT TO CORRECT THE DEFECT SHALL PLACE THE BURDEN OF COST AND <br />LIABILITY FROM SUCH DEFECT UPON THE CONTRACTOR. <br />2. INTENT: THE ARCHITECT SHALL BE CONSULTED FOR CLARIFICATION IF SITE <br />CONDI°ITIONS ARE (ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DEC 2 <br />DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER <br />THE INTENT OF THE PLANS OR NOTES.` <br />3. DIMENSIONS: INTERIOR DIMENSIONS ARE TO FACE OF DRYWALL UNLESS OTHERWISE <br />NOTED, EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING OR FOUNDATION WALL. <br />ALL OPENINGS NOT LOCATED BY DIMENSIONS ON THE DRAWINGS SHALL BE 5" FROM <br />FACE OF ADJACENT WALL SURFACE TO EDGE OF ROUGH OPENING, OR CENTERED <br />BETWEEN ROOM PARTITIONS AS SHOWN. DOOR AND WINDOW DIMENSIONS SHOWN <br />ARE NOMINAL DIMENSIONS,; VERIFY ROUGH OPENING REQUIEMENTS WITH <br />MANUFACTURER. NOTE. THE EXISTING BUILDING IS NOT PLUMB AND SQUARE. <br />DIMENSIONS SHOWN ARE TO ESTABLISH THE MINIMUM REQUIRED OPENINGS AND <br />SPACES; PRIOR TO FRAMING THE CONTRACTOR SHALL u°ERIFYALIGNMEN7— OFALL <br />VERTICAL OPENINGS AND SHAFTS FOR COMPLIANCE WITH DIMENSIONAL INTENT <br />4. STAIRAND ELEVATOR SHAFTS: VERIFYAILL SHAFT DIMENSIONS WITH EXISTING <br />FRAMING CONDITIONS; ALIGN STUDS AT SHAFTWALLS WITH FACE OF EXISTING BEAMS <br />TO ALLOW DRYWALL TO RUN PAST UNINTERRUPTED. MAINTAIN SHAFT CLEAR <br />DIMENNIONS SHOWN ON DRAWINGS. <br />5. INTERPRETATIONS: DO NOT SCALE THE DRAWINGS. THE ARCHITECT SHALL BE <br />RESPONSIBLE FOR ALL INTERPRETATIONS OF DIMENSIONS AND ABBREVIATIONS, <br />6. BUILDING SYSTEMS DESIGN: ANY REQUIRED ENGINEERING DESING OR DESIGN OF THE <br />FOLLOWING BUILDING SYSTEMS BEYOND THE FIXTURES AS DESCRIBED IN THE <br />DRAWINGS WALL FOR THE RESPONSIBILITY OF THE FOLLOWING DESIGN BUILD <br />SUBCONTRACTORS: PLUMBING SYSTEM; ELECTRICAL SYSTEM; AND HEATING, <br />VENTILATION, AND AIR CONDITIONING (HN/AC) SYSTEM. FIRE PROTECTION SYSTEMS, <br />INCLUDING SPRINKLER DESIGN, SMOKE DETECTOR LOCATIONS, FIRE ALARM PULL <br />LOCATIONS, FIRE EXTINGUISHER LOCATIONS, AND ANNUNCIATOR AND FIRE <br />DEPARTMENT CONTROL PANEL LOCATIONS AS REQUIRED BY IBC CHAPTER 9 SHALL BE <br />THE RESPONSIBILITY OF THE FIRE PREVENTION DESIGN BUILD CONTRACTOR WHO <br />SHALL PREPARE ALL SUBMITTALS REQUIRED BY IBC SECTION 107.2.2. <br />7. ELECTRICAL: RECEPTACLES IN BATHROOMS, KITCHENS AND GARAGES SHALL BE G.F.I. <br />OR G,IF.I.C, PER NATIONAL ELECTRICAL CODE REQUIREMENTS. <br />3. VENTILATION: VENT FANS (MIN 100CFM) SHALL BE PROVIDED IN TOILET ROOMS AND <br />KITCHENS. <br />9. WEATHER AND AIR TIGHTNESS: INSTALL POLYISOCYANURATE FOAM TYPE INSULATION <br />AT FLOOR AND PLATE LINES, OPENINGS IN PLATES, CORNER STUD CAVITIES AND <br />AROUND DOOR AND WINDOW ROUGH OPENING CAVITIES. ALL EXTERIOR WALL <br />OPENINGS, FLASHING, COUNTERFLASHING, ETC. SAHLL BE CONSTRUCTED IN SUCH A <br />MANNER AS TO MAKE THEM WATERPROOF. ACCESSORIES MOUNTED ON OR WITHIN <br />WALLS SHALL BE INSTALLED AND SEALED TO PROTECT THE STRUCTURAL ELEMENTS <br />FORM MOISTURE. <br />10. BLOCKING: PROVIDE SOLID WOOD BLOCKING FROM 2X MATERIAL BEHIND ALL <br />INSTALLED ITEMS SUCH AS CABINETRY, WOOD TRIM, BATH ACCESSORIES, ETC. <br />or i <br />For Thls- Pvtocl-750 Include: <br />Plumbingprd Wor <br />k Mechiandcal , Fire Alai <br />r ,jw x i [. " <br />r <br />LEGAL a [, DESCRIPTION: EVERETT PLAT <br />ce'I :i I O ,a L i 680 D0,i LOTS j S I" .M <br />WON, WD AUMMAM FIRE <br />DETECTO SYSTEM REQUIRED <br />SPRMLER SYSTEHIMEQUIRED <br />a <br />Use: COMMERCIAL ALTERATIONS <br />In: MINOR DEMO, MOD PARTITION WALLS, <br />ADD LOADING DOCK <br />i Date: <br />BV:jL <br />Set lake Site Set Fire/Pl nning Set <br />
The URL can be used to link to this page
Your browser does not support the video tag.