My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
405 SE EVERETT MALL WAY 2021 Plans 2022-11-21
>
Address Records
>
SE EVERETT MALL WAY
>
405
>
Plans
>
405 SE EVERETT MALL WAY 2021 Plans 2022-11-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 8:38:20 AM
Creation date
12/14/2021 2:34:09 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
405
Permit
B2102-051
Year
2021
Notes
Remodel to create storage to support guest order fulfillment
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOT USED— <br />PN101 <br />3 NOT USED _ ---- <br />PM01 <br />ROD HANGER �- <br />III (III <br />STRAPHANGER <br />BAR JOIST OR <br />STEEL BEAM <br />TYPICAL <br />STEEL ANGLE -�-I r--- R DUCT :WIDTHS SCREW STRAP TO <br />DUCT WIDTHS LESS THAN 36" DUCT. MINIMUM <br />36" OR GREATER i" STRAP LENGTH <br />PRE -PUNCHED CHANNEL ON UNDERSIDE <br />SUPPORT FASTENEDTO OF DUCT. <br />ROOF DECK T TOP OF BAR JOIST. <br />TYPICAL i (TYPICAL. <br />s_ Irk <br />--!--�� 'III <br />STRAP HANGER � ROD HANGER OR <br />Iy' I STRAP HANGER <br />BAND SAME SIZE y'! i \ III <br />STRAP <br />HANGER <br />36' <br />LU MAXIMUM GREATER THAN <br />DUCT DIAME I ER 36"DUCT DIAMETER <br />GENERAL NOTES: <br />A. REFER TO CMACHA HVAC DUCT CONSTRUCTION STANDARDS" FOR HANGER REQUIREMENTS, <br />INCLUDING STRAP HANGERS, ROD HANGERS, STEEL ANGLES AND FASTENERS. <br />6_ SUPPORT FROM BAR JOIST TOP CHORD PANS PNT. <br />C. .MAXIMUM LOAD ON ANY PANEL !S III LIS, UNLESS APPROVED BY STRUCTURAL <br />ENGINEER- SEE STRUCTURAL FOR ADDITIONAL HE HINTS <br />D. SEE 1/1111/1 FOR SEISMIC BRACING DETAIL. <br />E DO NOT INSTALL DUCTWORK CLOSER THAN 8" TO ANY WATER, FIRE PROTECTION, OR <br />GAS PIPING_ <br />DUCT HANGERS <br />PM01 SCALE: NOTTOSCALE <br />0 SALES FLOOR GRILLES AND REGISTER SQUARE TO ROUND <br />ADAPTERS PROVIDED BY OWNER WHERE NOTED ON PLAN <br />SHEETS, ALL OTHERS SHALL BE CONTRACTOR PROVIDED. <br />SEE PLANS FOR SEE PLANS FOR <br />NECK SIZE <br />NECK SI7_E <br />GRILLE OR <br />REGISTER GRILL OR <br />BELOW REGISTER <br />1XH2, 24x24 OR 624 OR 12x24 BELOW <br />24'x48" (18"x30" NECK) <br />NOTE <br />MAXIMUM OF 18" OF FLEX DUCT MAY BE USED FOR FINAL CONNECTION_ <br />GRILLE & REGISTER BOOT_-- <br />PM101 SCALE: NOTTOSCALE <br />HVAC SYMBOLS <br />ITEM INDICATED <br />DOUBLE LINE DRAWING <br />I <br />REPRESENTATION <br />DUCT (1st RGURESIDESHOVVN <br />Id FIGURE SIDE NOT <br />If <br />24x20 - <br />SHOWN}� <br />j <br />DT;ON <br />2CJ2 �a� 2VR <br />(SUPPLY) <br />I <br />DUCT SECTION <br />24s12 / / `� 24"i^ <br />(RETURN) <br />- <br />SUPPLY DUCT <br />TURNING TURNING <br />P 24"y DO�Mil <br />TURNING UP OR DOWN <br />y <br />RETURN DUCT <br />TURNING T j - TURNING <br />UP 24 � - DOWN - <br />TURNING UP OR DOWN <br />— - - <br />EXHAUST DUCT <br />TURNING UP DORY DOWN <br />4"© <br />TURNING UP OR DOWN <br />CT <br />TURNING - <br />/ <br />2S� <br />TURNING <br />DODjN <br />TURNING UPDOih.'N <br />INCLINED RISER) OR DROP(D) <br />L <br />REFER TO PLANS FOR BOD HEIGHTS <br />ECCENTRIC DUOT FITTING <br />I l l <br />0x12 24x12 <br />CONCENTRIC DUCT FITTING <br />20x12 24x12 <br />i <br />----------- <br />BRANCH DUCT TAKE -OFF <br />USING RECTANGULAR <br />24xi2 �' BALANCING <br />_11 DAMPER <br />DUCTWORK MAIN <br />12x10 I� �V- <br />I <br />POWER ROOF VENTILATOR <br />) <br />J,/j �/\���12 <br />DIFFUSER <br />500 <br />DESCRIPTION C. REFERSTOTYPE <br />12" NECK SIZE ISO ONES) <br />\ - <br />1 <br />500: OEM <br />�- <br />(REFER TO M301 <br />--I- <br />FORDIFFUSERTYPE) <br />SUPPLY, RETURN OR EXHAUST <br />REGISTERN <br />1�8 <br />10, TI <br />DESCRIPTION H: REFERSTOTIPE <br />12x8: REGISTER SIZE <br />! I <br />200; CFM <br />4' <br />(REFER TO 1,01 <br />FOR REGISTER TYPE) <br />CEILING RETURN GRILLE <br />DESCRIPTION F: REFERSTOTYPE <br />24x12: GRILLE SIZE <br />(REFER TO M301 <br />� 2gx12 <br />FOR GRILLE TYPE) <br />F <br />TRANSFER GRILLE& <br />DUCTWORK <br />DESCRIPTION <br />46 �x <br />F: REFERS TO TYPE <br />24z6: GRILLE SIZE <br />�� 24T7Ax6 <br />FJ I <br />(REFER TO M301361 TIA: TRANSFER A!R <br />� SQUARE TO <br />FCR GRILLE TYPE) <br />ROUND ADAPTER <br />TRANSFER GRILLE & <br />DUCTWORK <br />DESCRIPTION F. REFERSTOTYPE <br />22'e <br />2424- GRILLE SIZE <br />T/A: TRANSFER. AIR <br />(REFER TO M301 <br />� 2 ' <br />24z2A h�4 <br />FOR GRILLE TYPE) <br />T/A T/A <br />IINEAR SLOT DIFFUSER <br />-r'� LEXIBLE DUCT I <br />r <br />WITH BOOT <br />DESCRIPTION K: DIFFUSERTYPE <br />8": BOOT AIDTHECK ZE <br />1.0": SLOTWIDTH <br />330: OEM <br />r <br />/ <br />(REFER <br />(REFER TO M301 <br />FOR DIFFUSER TYPE) <br />3-5 DUCT DIAMETERS SIZED TO <br />VARIABLE AIR VOLUME BOX <br />18"q BOX INLET, TYPICAL <br />(SIZE AND SHARE OFBOX WILLVARY) <br />15 I ?— <br />18' a <br />3-5 DUCT DIAMETERS SIZED TO <br />BOX I NLET, TYPICAL <br />FAN POWERED VARIABLE AIR IT)' BOX <br />/ FLEXIBLE <br />/ CONNECTOR <br />(SIZE AND SHAPE OF BOX WILL VARY) <br />UNIT HEATER <br />CJ 18"a <br />�� SECTION VIEW <br />THERMOSTAT OR TEMPERATURE SENSOR <br />i O <br />TEMPERATURE & HUMIDITY SENSOR <br />TH <br />UNIT STATIC PRESSURE SENSOR <br />- -- <br />PLUMBING / PIPING SYMBOLS <br />SYMBOL— <br />DESCRIPTION <br />- <br />-- <br />EDd <br />I� <br />LAVATORY (MULTI -STATION NOT SHOWN) <br />EC(G <br />'WATER CLOSET <br />1 <br />URINAL <br />10 <br />SINK <br />El <br />JANITORS SINK <br />ELECTRIC WATER COOLER <br />HUB DRAIN <br />FLOOR DRAIN <br />FLOOR SINK <br />t <br />RCOF DRAIN <br />! <br />OTI <br />CLEAN OUT <br />FUNNEL DRAIN <br />I6I <br />VENT THROUGH ROOF <br />j <br />-IT HYDRANT/INSIDE HOSE BIBS <br />-� <br />GAS SHUTOFF VALUE <br />- <br />PRESSURE REGULATOR <br />INV-X". EL. <br />XX' <br />INVERT ELEVATION TAG <br />xx' x' <br />� X <br />BOTTOM OF DUCT ELEVATION TAG <br />TOP CONNECTION <br />I <br />- <br />BOTTOM CONNECTION <br />DROP IN DIRECTION OF FLOW <br />_ <br />RISE IN DIRECTION OF FLOW <br />.� <br />SHUTOFF VALVE <br />--'Iif-- <br />WAFER CHECK VALVE <br />STRAINER <br />--%'--- <br />UNION <br />—��-r— <br />SWING CHECK VALVE <br />- <br />FCW <br />FILTERED COLD WATER <br />I <br />COLD WATER <br />-HW---- <br />HOT WATER <br />HWR --- <br />RECIRCULATING HOT WATER <br />—LP------ <br />LIQVEFEU PETROLEUM <br />V-_ <br />I <br />VENT <br />SD- <br />STORM DRAIN <br />CD - <br />CONDENSATE DRAIN <br />---G-- <br />NATURAL GAS <br />_- <br />-GWr- -_ <br />GREASE WASTE <br />I <br />CWV - <br />C0611I1ATION WASTE &VENT <br />SNJ - <br />SANITARY WASTE <br />VAC-- <br />CONDENSATE VACUUM <br />RO <br />REVERSE OS110SIS FILTERED COLD WATER <br />SITE!RRIGATION <br />PIPEANCHOR <br />PIPE BREAK <br />CONNECT TO EXISTING OR SYSTEMS PROVIDED BY NIC <br />XX <br />OWIUEft FURNISHED EQUIPMENT SYMBOL <br />REFER TO SHEET A601 FOR EQUIPMENT <br />INFORMATION <br />/ KD ID-d. <br />X" X' 3 <br />PLUMBING DRAIN TAG <br />MECHANICAL SYMBOLS <br />SYMBOL <br />DESCRIPTION <br />SMOKE DAMPER <br />FIRE DAMPER <br />P <br />''_/n,i, <br />BALANCING DAMPER <br />L^L'- <br />MOTORIZED DAMPER <br />/ � 1 <br />GRAVITY DAMPER <br />COMBINATION FIRE/SMOKE DAMPER <br />--C-�' <br />DOOR UNDER CUT <br />FIRE PROTECTION <br />SYMBOLS <br />l <br />4 <br />SYMBOL <br />DESCRIPTION <br />� <br />FIRE PROTECTION PIPING <br />I <br />INSPECTORS TEST CONNECTION <br />NOTE: NOT ALL SYMBOLS MAY APPEAR. <br />ON DRAWINGS. <br />SHEET INDEX <br />PM01 <br />SHEET INDIX <br />ME'ME111 <br />M307 <br />- <br />GROCERY PICKUFPICKU� h^JAG PLANS <br />1'L <br />TARGET,1000 NICOLLE T MALL <br />MINNEAPOLIS, MN 55403 <br />! <br />MICHAEL ID. WOEHRLE, P.P. <br />9100 49th Avenue N. <br />MINNEAPOLIS, MN 55428 <br />Tel: (763) 367-7600 <br />Fax: (763) 367-7601 <br />Late I No. Description <br />01/28/21 BP-3.0 COMPLETE <br />(CONSTRUCTION <br />I <br />�Rg1, D. 1D, <br />�1G OT n'ASgY�j <br />a <br />�N. <br />50318 l o"` <br />°>r `LFcratet�c �'® <br />DATE: EXP. <br />01-28-91 _ 11-19-22 <br />1/27/2021 11:34:33 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.