Laserfiche WebLink
TCURBF <br />SUPPLY PLENUM <br />#P WS131 <br />OCCUPIED SET POINT <br />TO BE CONTROLLED <br />BY nLIGHIT OCCUPAN( <br />SENSORS <br />imW ! ­. ­', j, iW �! <br />!pH 91 <br />1LN <br />I <br />I1Tl11110"[flili Tl� <br />Rp <br />Pz (calc) Pz (used) 1(cfm/pe <br />29 29 1 10 <br />Az = room area (sf) <br />Occ. Dens = occupant density (from Table 403.3) <br />Pz (calc) = zone population or occupant quantity (calculated) <br />Pz (used) = zone population or occupant quantity (user can override the calculation -increase only) <br />Rp = people outdoor airflow rate in breathing zone (cf/person) <br />Ra = area outdoor airflow rate in breathing zone (cfm/sf) <br />Vbz = Breathing zone outdoor airflow rate Per ea. 4-1( RP*Pz+Ra*Az) <br />MECHANICAL NOTES: <br />1. DUCT MATERIAL IS 26 GA. GALV. AND FLEX DUCT. DUCTWORK SHALL BE SUPPORTED PER 2015 IMC <br />WAC CHAPTER 6. SECTION 603 <br />2. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25, SMOKE DEVELOPMENT <br />OF 50 PER 2015 IMC WAC CHAPTER 6. SECTION 602 <br />3. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND <br />CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND SEALED WITH <br />WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC -PLUS EMBEDDED -FABRIC SYSTEMS OR APPROVED TAPES <br />INSTALLED IN ACCORDANCE WITH 2O15 IMC WAC CHAPTER 6 SECTION 603.9. <br />4. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEN THEY SHALL COMPLY <br />WITH IMC CHAPTER 6 <br />5. <br />10" DIFFUSERS WITH NO MANUAL DAMPERS. USE <br />FLOW CONTROLS <br />AT WYES, TYPICAL AS NOTED ON PLAN <br />6. <br />MINIMUM OUTSIDE AIR VENTILATION PER 2015 IMC <br />WAC CHAPTER <br />4, TABLE 403.3.1.1. <br />7. <br />OUTSIDE AIR DAMPERS SHALL COMPLY WITH 2O15 <br />WSEC, SECTION <br />C403.2.4.3. <br />8. <br />SINGLE PACKAGE UNITARY FAN COOLING UNITS HAVING A TOTAL <br />COOLING CAPACITY OF GREATER THAN <br />20,000 Btu/h REQUIRE ECONOMIZERS PER WSEC <br />403.3. EXCEPT <br />AS PERMITTED BY C403.3 EXCEPTION 1 <br />MECHANICAL NOTES: (cont.) <br />MECHANICAL EQUIPMENT INSTALLATION IN OR ON THIS BUILDING SHALL BE IN ACCORDANCE WITH <br />THE REQUIREMENTS OF THE 2015 IMC WAC CHAPTER 6. <br />ROUND FLEX DUCT SHALL BE U.L. LISTED CLASS 1, STANDARD 181 -- FACTORY MADE AIR DUCTS AND AIR <br />CONNECTORS. MEASURED IN ACCORDANCE TO ASTM C 518 OR ASTM C 177 AT 75DEG F MEAN <br />TEMPERATURE. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURES INSTALLATION INSTRUCTIONS <br />MECHANICAL DRAWINGS SHOW DUCTWORK SIZES TO BE CLEAR INSIDE DIMENSION. <br />DUCT INSULATION SHALL COMPLY WITH 2O15 IMC WAC CHAPTER 6, SEC. 604. <br />ELECTRICIAN MUST VERIFY ALL ELECTRICAL REQUIREMENTS AND LOCATIONS <br />THERMOSTAT SCHEDULING TO BE PERFORMED ON SITE BY OTHERS. <br />ALL HVAC EQUIPMENT LEAVES FACTORY WIRED FOR 240 VOLT OPERATION <br />THE ACCEPTABLE OPERATING RANGE FOR THE 240V & 208V TAPS ARE: <br />TAP RANGE <br />240 253-216 <br />208 220-187 <br />SITE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THE RIGHT TAP IS CONNECTED FOR <br />THE APPLIED SITE VOLTAGE. <br />AIR FILTERS IN HVAC UNITS OR SYSTEMS ARE TO BE CHANGED EVERY 30 DAYS BY OTHERS ON SITE. <br />REGISTER AIR FLOW TEST AND BALANCE OF HVAC SYSTEM TO BE PROVIDED AND PERFORMED BY OTHERS ON SITE. <br />HVAC SITE CONTRACTOR IS RESPONSIBLE FOR BALANCING THE SYSTEM. (2015 IMC WAC 403.3.3.1.5) <br />DEALER L <br />❑ APPROVED­1Y t rr <br />,�'� <br />El APPROVED EXCEPT S NOTE® RE' Ina I <br />I 1� <br />❑ REVISE AS NOTE® AND RESUBMT NOT <br />FOR CONSTRUCTION <br />APPROVE® By Date <br />DOAS/ERV/ELECTRICAL 10 <br />DOAS/ERV/ELECTRICAL © <br />COOLING CAPACITY 3) <br />HEATING CAPACITY ® <br />DOAS <br />UNIT <br />HEAT STRIPS <br />ENERGY RECOVERY <br />ELECT. INFORM. <br />ELECT.INFOR . <br />COMP <br />TOTAL <br />ECON. <br />BOAS <br />LOW VENTILATION MODE <br />FULL VENTILATION MODE <br />COOL <br />SENS. <br />COOL <br />SENS. <br />HTG <br />HTG <br />OUTDOOR <br />BARD <br />TYPE <br />CFM <br />BLR. <br />100% <br />ERV <br />OSA <br />OUTSIDE <br />ENT <br />ENT <br />CAP. <br />CAP. <br />CAP. <br />CAP. <br />OUTSIDE <br />CAP. <br />CAP, <br />SUMMER <br />DB/WB <br />HRS <br />HRL <br />WINTER <br />INDOOR <br />WHIR <br />ELEC. <br />HEAT <br />ELEC. <br />HEAT <br />OPER, <br />WGT. <br />ECM <br />ECM <br />TAG <br />QTY <br />MODEL # <br />TONS <br />SCROLL <br />NOM. <br />TYPE. <br />FREEFLOW <br />' VENTIL. <br />V-PH <br />ERV <br />BLOWER <br />V-PH <br />ERV <br />BLOWER <br />DB <br />DB <br />WB <br />EER <br />IPLV <br />BTUH <br />BTUH <br />BTUH <br />BTUH <br />DB <br />COP <br />BTUH <br />BTUH <br />EFFICIENT <br />DEG'S <br />BTUH <br />BTUH <br />EFFICIENT <br />DB <br />MOP <br />V-PH <br />MCA <br />MOP <br />CKT <br />V-PH <br />MCA <br />BTUH <br />CKT <br />KW <br />BTUH <br />LBS: <br />PART/FULL <br />MOTOR <br />MOTOR <br />PART LOAD <br />PART LOAD <br />FULL LOAD <br />FULL LOAD <br />.PART/LOAD <br />FULL/LOAD <br />HP-1 <br />1 <br />C36HA-A10ZP4XXR <br />3 <br />2-STAGE <br />750 <br />ECM <br />N0 <br />388 <br />450 <br />230/1 <br />AMPS-1.3 <br />WATTS-296 <br />AMPS-.87 <br />WATTS-95 <br />230/1 <br />AMPS-2.2 <br />WATTS-497 <br />AMPS-1.74 <br />WATTS-192 <br />95 <br />80 <br />67 <br />11:0 <br />14.5 <br />23.4K <br />18.5K <br />35K <br />26.3K <br />47 <br />3.3 <br />22.7K <br />31K <br />65% <br />95/70 <br />6,318 <br />1,711 <br />80% <br />1,711 <br />23,328 <br />230/1 <br />27 <br />40 <br />A <br />240/1 <br />52 <br />60 <br />B <br />10 <br />34,130 <br />678 <br />1100 <br />ADDITIONAL REMARKS; <br />1 - ENERGY MODEL PLAN APPROVAL #15FBS1700193 <br />2 - INCLUDE BARD WALL CURB #TCURBF3642A-4. <br />3 - THERMOSTAT, BARD#8403-060, 7-DAY PROGRAMMABLE <br />4 - WALL CO2 SENSOR. #8403-067 <br />5 - OCCUPANCY SENSOR, (SUPPLIED BY BLAZER) <br />6 - GPS (FIELD INSTALLED CONTROL KIT). <br />7 - 2" FILTER. <br />8 - ERV (DOAS) ENERGY RECOVERY. <br />9 - UNIT COLOR IS *BUCKEYE GRAY* <br />10 PRE INSTALLED OUTDOOR THERMOSTAT, SET AT 40DEG'S. <br />** M.C. TO REFER TO INSTALLATION INSTRUCTIONS FOR START UP AND EQUIPMENT SET. <br />x* M.C. TO CHECK SITE VOLTAGE AND SET CORRECT TAP ON TRANSFORMER. <br />** M.C. TO SET AND PROGRAM THERMOSTAT PER CUSTOMERS REQUIREMENTS. <br />C36H1 <br />ERV Watts - Low <br />296 Watts <br />Blower Full Load <br />192 Watts <br />ERV Amps - Low <br />1.3 Amps <br />Blower Full Load <br />1.74 Amps <br />ERV CFM - Low <br />300 CFM <br />Blower Part Load <br />95 Watts <br />ERV Watts - Med <br />415 Watts <br />Blower Part Load <br />0.87 Amps <br />ERV Amps - Med <br />1.8 Amps <br />ERV CFM - Med <br />375 CFM <br />Compressor Full <br />2588 Watts <br />ERV Watts - Hi <br />497 Watts <br />Compressor Full <br />11.46 Amps <br />ERV Amps - Hi <br />2.2 Amps <br />Compressor Part <br />1734 Watts <br />ERV CFM - Hi <br />450 CFM <br />Compressor Part <br />7.99 Amps <br />Outdoor Fan <br />380 Watts <br />Outdoor Fan <br />1.67 Amps <br />The sequence of operation for the Integrated DOAS system. <br />1. Upon a call from the occupancy sensor the (BOAS) ERV and the indoor (ECM) motor will <br />start in low vent mode and ventilate the space continuously as occupied. <br />Note: 1 on the HVAC Schedule. <br />2. Upon a call from the CO2 sensor the (BOAS) ERV and the indoor (ECM) motor will <br />change to full vent mode and ventilate the space until the CO2 sensor is satisfied and then <br />revert back to the low vent mode during the occupied time. <br />Note: 2 on the HVAC Schedule. <br />3. The Beating and Cooling section will only work if there is a Heating or Cooling tail from <br />the thermostat. This action works entirely independent of the DOAS ventilation portion. <br />Note: 3 & 4 on the HVAC Schedule. <br />ADDITIONAL <br />REMARKS <br />1, 2, 3, 4, 5, 6, 7, 8 <br />