J JUNCTION BOX
<br />F FURNITURE WALL FEED OUTLET BOX
<br />PB PULL BOX
<br />XX-#--(WHERE # = PULL BOX NEMA RATING)
<br />(WHERE XX = PULL BOX SIZE
<br />(6 = 6" X 6" X 6" PULL BOX)
<br />(12= 12"X 12" X 6" PULL BOX)
<br />UTILITY VAULT
<br />El (WHERE INDICATED, SUBSCRIPT INDICATES UTILITY VAULT TYPE)
<br />XX
<br />ml FLOORBOX (WHERE INDICATED, SUBSCRIPT INDICATES FLOOR
<br />A BOX TYPE)
<br />POKE-THRU (WHERE INDICATED, SUBSCRIPT INDICATES
<br />A POKE-THRU TYPE)
<br />POWER POLE, FLOOR TO CEILING
<br />SURFACE METAL RACEWAY
<br />RACEWAY CONCEALED IN WALL OR IN CEILING
<br />(EXPOSED IN UNFINISHED AREAS)
<br />®®® RACEWAY RUN BELOW FLOOR OR BELOW GRADE
<br />FLEXIBLE RACEWAY
<br />RACEWAY (CIRCLE DENOTES VERTICAL
<br />TRANSITION)
<br />RACEWAY CONTINUATION
<br />RACEWAY STUB WITH BUSHING
<br />RACEWAY SLEEVE WITH BUSHING
<br />FIRE STOPPING SLEEVE
<br />CABLE TRAY, 12"W X 4°'H OVERHEAD, UNLESS
<br />OTHERWISE NOTED
<br />CABLE TRAY, OVERHEAD LADDER TYPE
<br />HOMERUN TO PANEL
<br />HA-3 (INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER)
<br />10 -(GAUGE OF WIRE OTHER THAN AWG#12)
<br />NUMBER OF CONDUCTORS
<br />(GROUND CONDUCTOR)
<br />(PHASE CONDUCTORS)
<br />\ (NEUTRAL CONDUCTOR)
<br />GROUNDING
<br />G
<br />GROUNDING CONDUCTOR
<br />®
<br />GROUND ROD
<br />®
<br />GROUNDING BUSBAR
<br />71
<br />EQUIPMENT GROUNDING CONNECTION
<br />GROUNDING STRAP
<br />TELECOMMUNICATIONS DEVICE
<br />(X = REPRESENTS THE # OF TELECOMMUNICATIONS MODULES)
<br />(W = TELECOMMUNICATIONS WALL PHONE MTD AT +48" AFF)
<br />(B = BLANK COVER PLATE)
<br />x1 (F = MODULAR FURNITURE DEVICE)
<br />Y (AC = ABOVE COUNTER DEVICE)
<br />(S = SURFACE MOUNT)
<br />(WAP = WALL MOUNTED WIRELESS ACCESS POINT DATA DEVICE)
<br />ABOVE CEILING TELECOMMUNICATIONS DEVICE
<br />(X = REPRESENTS THE # OF TELECOMMUNICATIONS MODULES)
<br />P(WAP = WIRELESS ACCESS DEVICE)
<br />(SV = SECURITY VIDEO CAMERA)
<br />FIRE RESISTANT 3/4" PLYWOOD BACKBOARD
<br />TWO -POST EQUIPMENT RACK
<br />3.65" DOUBLE -SIDED VERTICAL MANAGEMENT
<br />6" DOUBLE -SIDED VERTICAL MANAGEMENT
<br />12" DOUBLE -SIDED VERTICAL MANAGEMENT
<br />WALL MOUNTED ENCLOSURE
<br />FLOOR MOUNTED SERVER ENCLOSURE
<br />110 BLOCK WITH LEGS
<br />66 BLOCK
<br />ACCESS CONTROL TE
<br />ACCESS CONTROL PANEL
<br />ACP �(C = CONTROLLER, CONNECTED TO NETWORK)
<br />(X)AS = SUBCONTROLLER, CONNECTED VIA RS-485)
<br />CREDENTIAL/ CARD READER
<br />S (CR = CARD READER, WALL MOUNTED)
<br />CR (CR/P = CARD READER W/PIN, WALL MOUNTED)
<br />(CR/M = CARD READER, MULLION MOUNTED)
<br />cR INTEGRATED CARD READER/ WIRELESS DOOR
<br />HARDWARE
<br />PIM WIRELESS PANEL INTERFACE MODULE
<br />DOOR POSITION SWITCH
<br />S _ --(S = SURFACE MOUNTED)
<br />El DOOR ENTRY STATION, WALL MOUNTED
<br />MS DOOR MASTER STATION, DESK TOP
<br />SECURITY BUTTONS/SWITCH, \/\/ALL MOUNTED
<br />(AO = AUTO OPERATOR)
<br />S (DR = DOOR RELEASE)
<br />XX (LD = LOCKDOWN)
<br />(KS = KEYED SWITCH
<br />(PB = PANIC/ DURESS)
<br />SECURITY BUTTONS, UNDER DESK MOUNTED
<br />® (DR = DOOR RELEASE)
<br />(LD = LOCKDOWN)
<br />(PB = PANIC/ DURESS)
<br />R' REQUEST TO EXIT DETECTOR, °J1/ALL MOUNTED
<br />R, REQUEST TO EXIT DETECTOR, CEILING MOUNTED
<br />R REQUEST TO EXIT, INTEGRAL MACRO SWITCH
<br />R REQUEST TO EXIT BUTTON, WALL MOUNTED
<br />s HORN, WALL MOUNTED
<br />s STROBE, WALL MOUNTED
<br />s STROBE/ SIREN, CEILING MOUNTED
<br />�S DOOR HARDWARE POWER SUPPLY (DIV 08)
<br />X (X = QUANTITY OF DOORS)
<br />EL ELECTRIFIED HARDWARE
<br />(EL = ELECTRIFIED LOCKSET/EXIT DEVICE)
<br />(ES = ELECTRIFIED STRIKE)
<br />(ML = ELECTRIFIED MAGNETIC LOCK)
<br />(MH = ELECTRIFIED MAGNETIC HOLD OPEN)
<br />GENERAL (NOTES
<br />ABBREVIATIONS
<br />DRA I INDEX
<br />EME ST0.1 SECURITY AND TELECOM( LEGEND AND
<br />1.
<br />PERFORM WORK IN ACCORDANCE WITH
<br />A
<br />AMIIPERE
<br />MAXMAXIMUM
<br />DRAWING INDEX
<br />APPLICABLE NATIONAL AND STATE CODES AS
<br />AC
<br />AIR CONDITIONING; ALTERNATING CURRENT;
<br />MC
<br />MAIN CROSS CONNECT; METAL CLAD (CABLE)
<br />AMENDED LOCALLY AND ENFORCED BY THE AHJ.
<br />ABOVE COUNTER
<br />MCC
<br />MOTOR CONTROL CENTER
<br />EME ST2.1 SECURITY AND TELECOM FLOOR PLAN
<br />AF
<br />AMP FUSE; AMP FRAME
<br />MCB
<br />MAIN CIRCUIT BREAKER
<br />EME ST8.1 SECURITY AND TELECOM DETAILS
<br />2.
<br />OBTAIN AND PAY FOR PERMITS REQUIRED FOR
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />INSTALLATION OF WORK. ARRANGE AND
<br />AG
<br />ABOVE GRADE
<br />MIDF
<br />MAIN DISTRIBUTION FRAME
<br />SCHEDULE REQUIRED INSPECTIONS.
<br />MDP
<br />MAIN DISTRIBUTION PANEL
<br />AHJ
<br />AUTHORITIES HAVING JURISDICTION
<br />MFR
<br />MANUFACTURER
<br />3.
<br />DEVICE LOCATIONS ARE APPROXIMATE.
<br />AHU
<br />AIR HANDLING UNIT
<br />MH
<br />MANHOLE
<br />COORDINATE DEVICE LOCATIONS AND ELEVATIONS
<br />AIC
<br />AMPERE INTERRUPTING CURRENT
<br />MIN
<br />MINIMUM
<br />WITH APPROPRIATE DOCUMENTS INCLUDING SHOP
<br />AL
<br />ALUMINUM
<br />MLO
<br />FAIN LUGS ONLY
<br />DRAWINGS AND ARCHITECT'S INTERIOR
<br />ANSI
<br />AMERICAN NATIONAL STANDARDS INSTITUTE
<br />MM
<br />MULTIMODE
<br />ELEVATIONS PRIOR TO ROUGH -IN.
<br />AS
<br />AMP SWITCH
<br />MPOE
<br />MAIN POINT OF ENTRY
<br />4.
<br />DEMOLISH EXISTING SYSTEMS AS INDICATED ON
<br />AT
<br />AMP TRIP
<br />MPOP
<br />MAIN POINT OF PRESENCE
<br />PLANS OR AS REQUIRED FOR INSTALLATION OF
<br />ATS
<br />AUTOMATIC TRANSFER SWITCH
<br />MTD
<br />MOUNTED
<br />NEW WORK. MATERIAL SHALL BE REMOVED FROM
<br />ATM
<br />ASYNCHRONOUS TRANSFER MODE
<br />MTS
<br />MANUAL TRANSFER SWITCH
<br />SITE AND LEGALLY DISPOSED OF OFF SITE UNLESS
<br />AV
<br />AUDIO VISUAL
<br />OTHERWISE DIRECTED. RETURN ITEMS TO OWNER
<br />AWG
<br />AMERICAN WIRE GAUGE
<br />(N)
<br />NEW
<br />IN EXISTING CONDITION WHEN DIRECTED BY
<br />OWNER.
<br />N
<br />NEUTRAL
<br />BAS
<br />BUILDING AUTOMATION SYSTEM
<br />NAC
<br />NOTIFICATION APPLIANCE CIRCUIT
<br />5.
<br />COMPLETION OF WORK SHALL BE EXECUTED IN
<br />BATT
<br />BATTERIES
<br />NEC
<br />NATIONAL ELECTRICAL CODE
<br />ACCORDANCE WITH THE PROJECT SCHEDULE.
<br />BKBD
<br />BACKBOARD
<br />NATIONAL ELECTRICAL MANUFACTURERS
<br />SCHEDULE INSTALLATION WITH OTHER TRADES TO
<br />BIL
<br />BASIC IMPULSE INSULATION LEVEL
<br />NEMA
<br />ASSOCIATION
<br />ENSURE PROJECT MILESTONES ARE MET,
<br />BKR
<br />BREAKER
<br />NF
<br />NON -FUSED
<br />BLDG
<br />BUILDING
<br />NIC
<br />NOT IN CONTRACT
<br />6.
<br />DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW
<br />NL
<br />NIGHT LIGHT
<br />ALL COMPONENTS REQUIRED FOR A COMPLETE
<br />INSTALLATION. PROVIDE COMPONENTS REQUIRED
<br />C
<br />CONDUIT; DEGREES CELSIUS
<br />FOR COMPLETE AND OPERATIONAL SYSTEMS
<br />CAB
<br />CABINET
<br />OFC
<br />OPTICAL FIBER CABLE
<br />INCLUDING RACEWAYS, CONDUCTORS, BOXES,
<br />CAT
<br />CATEGORY
<br />OHL
<br />OVERHEAD LINE
<br />SUPPORTS AND SIMILAR ITEMS.
<br />CATV
<br />COMMUNITY ANTENNA TELEVISION
<br />OL
<br />OVERLOAD
<br />CB
<br />CIRCUIT BREAKER
<br />OS
<br />OCCUPANCY SENSOR
<br />7.
<br />LOCATIONS OF RACEWAY, PATHWAY AND SIMILAR
<br />CCTV
<br />CLOSED CIRCUIT TELEVISION
<br />OSP
<br />OUTSIDE PLANT
<br />ITEMS ARE SHOWN SCHEMATICALLY. COORDINATE
<br />INSTALLATION, INCLUDING BUT NOT LIMITED TO
<br />CLG
<br />CEILING
<br />CABLING, TELECOMMUNICATION PATHWAYS AND
<br />CM
<br />CEILING -(MOUNTED
<br />P
<br />POLE
<br />SPACES, AND EXACT LOCATION OF HORIZONTAL
<br />CO
<br />CONDUIT ONLY
<br />PBX
<br />PRIVATE BRANCH EXCHANGE
<br />AND BACKBONE CABLING WITH LOCATIONS OF
<br />COW
<br />COMPUTER ON WHEELS
<br />PF
<br />POWER FACTOR
<br />FIXED CASEWORK AND BUILDING CONDITIONS
<br />CR
<br />CONTROLLED RECEPTACLE
<br />PH
<br />PHASE
<br />AFFECTING THE WORK OF THIS CONTRACT.
<br />CT
<br />CURRENTTRANSFORMER
<br />PIR
<br />PASSIVE INFRARED
<br />8.
<br />COORDINATE TELECOMMUNICATIONS/ SECURITY
<br />CU
<br />COPPER
<br />PIV
<br />POST INDICATING VALVE
<br />WORK WITH THAT OF OTHER TRADES. REFER TO
<br />PNL
<br />PANEL
<br />ELECTRICAL, ARCHITECTURAL DRAWINGS AND
<br />DDC
<br />DIRECT DIGITAL CONTROL
<br />PP
<br />PATCH PANEL
<br />SPECIFICATIONS. COORDINATION SHALL OCCUR
<br />DEMARC
<br />DEMARCATION POINT
<br />PT
<br />POTENTIAL TRANSFORMER
<br />PRIOR TO FABRICATION, PURCHASE, AND
<br />DISC
<br />DISCONNECT
<br />PVC
<br />POLYVINYL CHLORIDE
<br />INSTALLATION OF WORK.
<br />DIST
<br />DISTRIBUTION
<br />0.
<br />NEW CABLING INSTALLATIONS SHALL BE
<br />DSL
<br />DIGITAL SUBSCRIBER LINE
<br />RCP
<br />REFLECTED CEILING PLAN
<br />CONCEALED IN WALL, CEILINGS, AND BELOW
<br />DWG
<br />DRAWING
<br />REC
<br />RECEPTACLE
<br />RAISED FLOOR SPACES UNLESS OTHERWISE
<br />REF
<br />REFER TO
<br />NOTED ON THE DRAWINGS. CABLING IN
<br />(E)
<br />EXISTING
<br />REV
<br />REVISION
<br />ACCESSIBLE CEILING SPACES SHALL BE INSTALLED
<br />EA
<br />EACH
<br />RM
<br />ROOM
<br />AS OPEN CABLING NEAR STRUCTURES AND WALLS
<br />EF
<br />EXHAUST FAN
<br />RU
<br />RACK UNIT
<br />OR AS SPECIFICALLY NOTED ON DRAWINGS. SEE
<br />SPECIFICATIONS FOR SUPPORT REQUIREMENTS.
<br />EIA
<br />ELECTRONIC INDUSTRIES ASSOCIATION
<br />ELEV
<br />ELEVATION
<br />SHT
<br />SHEET
<br />10.
<br />PROVIDE FIRESTOPPING SYSTEMS FOR CONDUIT
<br />EM
<br />EMERGENCY
<br />SLC
<br />SIGNALING LINE CIRCUIT
<br />AND RACEWAY SYSTEMS AT PENETRATIONS,
<br />EMT
<br />(ELECTRICAL METALLIC TUBING
<br />SM
<br />SINGLEMODE
<br />SLEEVES AND SLOTS OF FIRE RATED
<br />ENCL
<br />ENCLOSURE
<br />SMFC
<br />SURFACE -MOUNTED OPTICAL FIBER CABINET
<br />CONSTRUCTION FOR HORIZONTAL PATHWAYS AND
<br />EPM
<br />ELECTRONIC POWER METER
<br />SMR
<br />SURFACE METAL RACEWAY
<br />SPACES.
<br />EPO
<br />EMERGENCY POWER OFF
<br />SONET
<br />SYNCHRONOUS OPTICAL NETWORK
<br />11.
<br />MINIMUM SPACING FROM ELECTRICAL APPARATUS
<br />EQUIP
<br />EQUIPMENT
<br />SP
<br />SERVICE PROVIDER
<br />SUCH AS MOTOR DRIVEN EQUIPMENT AND
<br />ETR
<br />EXISTING TO REMAIN
<br />SPD
<br />SURGE PROTECTIVE DEVICE
<br />TRANSFORMERS SHALL BE 6-0". SPACING
<br />EWC
<br />ELECTRIC WATER COOLER
<br />SPEC
<br />SPECIFICATIONS
<br />REQUIREMENTS SHALL APPLY TO OPEN CABLING
<br />SPST
<br />SINGLE POLE SINGLE THROW
<br />PATHWAYS WHERE EQUIPMENT IS LOCATED ON
<br />F
<br />FUSE; DEGREES FAHRENHEIT
<br />ST
<br />SHUNT TRIP
<br />THE SAME FLOOR, FLOOR ABOVE, FLOOR BELOW,
<br />FA
<br />FIRE ALARM(
<br />STP
<br />SHIELDED TWISTED PAIR
<br />OR IN ROOMS ADJACENT TO SUCH EQUIPMENT AS
<br />THOUGH WALLS AND FLOORS DID NOT EXIST.
<br />FAAP
<br />FIRE ALARM ANNUNCIATOR PANEL
<br />SVGA
<br />SUPER VIDEO GRAPHICS ARRAY
<br />EXCEPTION: BUILDING CONSTRUCTION THAT
<br />FACP
<br />FIRE ALARM",( CONTROL PANEL
<br />SW
<br />SWITCH
<br />RESULTS IN CONTINUOUS METALLIC BARRIER
<br />FBO
<br />FURNISHED BY OWNER
<br />SWBD
<br />SWITCHBOARD
<br />BETWEEN ELECTRICAL APPARATUS AND CABLE
<br />FOIC
<br />FURNISHED BY OWNER INSTALLED BY
<br />PATHWAYS SHALL BE CONSIDERED AS SUITABLE
<br />CONTRACTOR
<br />TBB
<br />TELECOMMUNICATIONS BONDING BACKBONE
<br />SEPARATION.
<br />FOIO
<br />FURNISHED BY OWNER INSTALLED BY OWNER
<br />TEL
<br />TELEPHONE
<br />FSD
<br />FIRE SMOKE DAMPER
<br />TELCO
<br />TELEPHONE COMPANY
<br />12.
<br />PRIOR TO STARTING TELECOMMUNICATIONS/
<br />SECURITY INSTALLATION, CAREFULLY INSPECT
<br />TGB
<br />TELECOMMUNICATIONS GROUNDING BUSBAR
<br />INSTALLED WORK OF OTHER TRADES AND VERIFY
<br />G
<br />GROUND
<br />TIA
<br />TELECOMMUNICATIONS INDUSTRY ASSOCIATION
<br />THAT SUCH WORK IS COMPLETE TO THE POINT
<br />GF
<br />GROUND FAULT CIRCUIT INTERRUPTER
<br />TMGB
<br />TELECOMMUNICATIONS MAIN GROUNDING
<br />WHERE WORK MAY PROPERLY COMMENCE.
<br />GFP
<br />GROUND FAULT PROTECTION
<br />BUSBAR
<br />NOTIFY THE ARCHITECT AND ENGINEER IN WRITING
<br />GND
<br />GROUND
<br />TP
<br />TAMPERPROOF
<br />OF CONDITIONS DETRIMENTAL TO THE PROPER
<br />GRS
<br />GALVANIZED RIGID STEEL
<br />TR
<br />TELECOMMUNICATIONS ROOM
<br />AND TIMELY COMPLETION OF THE WORK.
<br />TTB
<br />TELEPHONE TERMINAL BOARD
<br />13.
<br />DO NOT BEGIN TELECOMMUNICATIONS/ SECURITY
<br />HC
<br />HORIZONTAL CROSS CONNECT
<br />TV
<br />TELEVISION
<br />INSTALLATION UNTIL UNSATISFACTORY
<br />HID
<br />HIGH INTENSITY DISCHARGE
<br />TVSS
<br />TRANSIENT VOLTAGE SURGE SUPPRESSION
<br />CONDITIONS ARE RESOLVED. BEGINNING WORK
<br />HP
<br />HORSEPOWER
<br />TYP
<br />TYPICAL
<br />CONSTITUTES ACCEPTANCE OF CONDITIONS AS
<br />HTR
<br />HEATER
<br />SATISFACTORY
<br />Hz
<br />HERTZ
<br />UG
<br />UNDERGROUND
<br />UL
<br />UNDERWRITERS LABORATORIES
<br />14.
<br />ROUTE CATEGORY 6/6A CABLES TO THEIR
<br />IC
<br />INTERMEDIATE CROSS CONNECT
<br />UON
<br />UNLESS OTHERWISE NOTED
<br />ASSIGNED CROSS -CONNECT AND TERMINATE
<br />CABLES ON 48-PORT PATCH PANELS ON RACKS
<br />IBC
<br />INTERNATIONAL BUILDING CODE
<br />UPS
<br />UNINTERRUPTIBLE POWER SUPPLY
<br />UNLESS OTHERWISE NOTED.
<br />IDF
<br />INTERMEDIATE DISTRIBUTION FRAME
<br />USB
<br />UNIVERSAL SERIAL BUS
<br />IEEE
<br />INSTITUTE OF ELECTRICAL AND ELECTRONIC
<br />UTP
<br />UNSHIELDED TWISTED PAIR
<br />15.
<br />ROUTE SECURITY CABLES TO THEIR ASSIGNED
<br />ENGINEERS
<br />UV
<br />UNIT VENTILATOR
<br />PANELS.
<br />IG
<br />ISOLATED GROUND
<br />IMC
<br />INTERMEDIATE METALLIC CONDUIT
<br />V
<br />VOLTS
<br />16.
<br />THE ELECTRICAL CONTRACTOR SHALL PROVIDE
<br />ISDN
<br />INTEGRATED SERVICES DIGITAL NETWORK
<br />VA
<br />VOLT AMPERES
<br />ALL CONDUIT, OUTLET BOXES, JUNCTION BOXES,
<br />RACEWAY SYSTEMS, ETC. FOR A COMPLETE AND
<br />VFD
<br />VARIABLE FREQUENCY DRIVE
<br />OPERATIONAL PATHWAY SYSTEM FOR ALL
<br />J
<br />JUNCTION
<br />TELECOMMUNICATIONS SYSTEMS PER THE SCOPE
<br />W
<br />WATT; WIRE
<br />OF WORK INDICATED ON THE CONSTRUCTION
<br />kVA
<br />KILOVOLT AMPERE
<br />W/
<br />WITH
<br />DRAWINGS AND BID SPECIFICATIONS.
<br />kW
<br />KILOWATT
<br />W/O
<br />WITHOUT
<br />KCMIL
<br />THOUSAND CIRCULAR MILS
<br />WA
<br />WORKSTATION AREA
<br />KVAR
<br />KILOVOLT AMPERE REACTIVE
<br />WAN
<br />WIDE AREA NETWORK
<br />WG
<br />WIRE GUARD
<br />LAN
<br />LOCAL AREA NETWORK
<br />WH
<br />WATT HOUR METER
<br />LCP
<br />LIGHTING CONTROL PANEL
<br />WP
<br />WEATHERPROOF
<br />LEC
<br />LOCAL EXCHANGE CARRIER
<br />LT
<br />LIGHT
<br />XMFR
<br />TRANSFORMER
<br />LTG
<br />LIGHTING
<br />Y
<br />WYE
<br />M
<br />METER
<br />ALL SYMBOLS MAY APPEAR ON THE DRAWINGS
<br />MAN
<br />METROPOLITAN AREA NETWORK
<br />Z
<br />IMPEDANCE
<br />SECURITY ROUGH -IN SCHEDULE
<br />SYMBOL
<br />j MOUNTING HEIGHT
<br />DEVICE NAME
<br />OUTLET BOX
<br />CONDUIT
<br />MUD RING
<br />DETAIL
<br />NOTES
<br />QTY
<br />SIZE
<br />QT�°
<br />SIZE
<br />TERM LOCATION
<br />S
<br />CR
<br />+48", LION
<br />CARD READER
<br />1
<br />4"S
<br />1
<br />3/4"
<br />ACCESSIBLE CLG
<br />SINGLE GANG
<br />2/ST8.2
<br />-
<br />s
<br />-
<br />DOOR POSITION SWITCH
<br />-
<br />-
<br />1
<br />3/4"
<br />ACCESSIBLE CLG
<br />-
<br />i
<br />2/ST8.2
<br />2
<br />S
<br />LD
<br />+48" OR
<br />ABOVE COUNTER
<br />LOCKDOWN BUTTON
<br />1
<br />4"S
<br />1
<br />3/4"
<br />ACCESSIBLE CLG
<br />SINGLE GANG
<br />-
<br />-
<br />RR
<br />UNDER DESK
<br />DOOR RELEASE BUTTON
<br />1
<br />4"S
<br />1
<br />3/4"
<br />ACCESSIBLE CLG
<br />SINGLE GANG
<br />-
<br />-
<br />EL
<br />_
<br />ELECTRONIC LOCKSET/ EXIT
<br />DEVICE
<br />_
<br />1
<br />3/4"
<br />ACCESSIBLE CLG
<br />-
<br />2/ST8.2
<br />2
<br />MH
<br />+78'°
<br />i
<br />MAGNETIC DOOR HOLD OPEN
<br />-
<br />-
<br />1
<br />'
<br />3/4°'
<br />ACCESSIBLE CLG
<br />-
<br />1/ST8.2
<br />2
<br />CAMERA
<br />1
<br />4"S
<br />1
<br />3/4"
<br />ACCESSIBLE CLG
<br />SINGLE GANG
<br />-
<br />-
<br />c
<br />CEILING
<br />i
<br />CAMERA
<br />1
<br />4"S
<br />1
<br />3/4"
<br />ACCESSIBLE CLG
<br />SINGLE GANG
<br />-
<br />'
<br />-
<br />GENERAL NOTE: MOUNTING HEIGHTS INDICATED ON THE SCHEDULE REFER TO CENTER OF BACK BOX.
<br />NOTE 1: DEVICE REQUIRES NETWORK CONNECTION, PROVIDE CATEGORY 6 CABLING (CABLING BY 271100).
<br />NOTE 2: COORDINATE REQUIREMENTS WITH DOOR HARDWARE.
<br />R </
<br />06.4a8. v .__
<br />_4
<br />9
<br />I
<br />s�
<br />a
<br />Ipsd
<br />is
<br />uj
<br />uj
<br />18-1041
<br />WE
<br />3-8-18
<br />DB
<br />CHEDW By
<br />PS
<br />AND
<br />TELECOM I C '♦ ' D
<br />D�,'i'' I
<br />
|