Laserfiche WebLink
J JUNCTION BOX <br />F FURNITURE WALL FEED OUTLET BOX <br />PB PULL BOX <br />XX-#--(WHERE # = PULL BOX NEMA RATING) <br />(WHERE XX = PULL BOX SIZE <br />(6 = 6" X 6" X 6" PULL BOX) <br />(12= 12"X 12" X 6" PULL BOX) <br />UTILITY VAULT <br />El (WHERE INDICATED, SUBSCRIPT INDICATES UTILITY VAULT TYPE) <br />XX <br />ml FLOORBOX (WHERE INDICATED, SUBSCRIPT INDICATES FLOOR <br />A BOX TYPE) <br />POKE-THRU (WHERE INDICATED, SUBSCRIPT INDICATES <br />A POKE-THRU TYPE) <br />POWER POLE, FLOOR TO CEILING <br />SURFACE METAL RACEWAY <br />RACEWAY CONCEALED IN WALL OR IN CEILING <br />(EXPOSED IN UNFINISHED AREAS) <br />®®® RACEWAY RUN BELOW FLOOR OR BELOW GRADE <br />FLEXIBLE RACEWAY <br />RACEWAY (CIRCLE DENOTES VERTICAL <br />TRANSITION) <br />RACEWAY CONTINUATION <br />RACEWAY STUB WITH BUSHING <br />RACEWAY SLEEVE WITH BUSHING <br />FIRE STOPPING SLEEVE <br />CABLE TRAY, 12"W X 4°'H OVERHEAD, UNLESS <br />OTHERWISE NOTED <br />CABLE TRAY, OVERHEAD LADDER TYPE <br />HOMERUN TO PANEL <br />HA-3 (INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER) <br />10 -(GAUGE OF WIRE OTHER THAN AWG#12) <br />NUMBER OF CONDUCTORS <br />(GROUND CONDUCTOR) <br />(PHASE CONDUCTORS) <br />\ (NEUTRAL CONDUCTOR) <br />GROUNDING <br />G <br />GROUNDING CONDUCTOR <br />® <br />GROUND ROD <br />® <br />GROUNDING BUSBAR <br />71 <br />EQUIPMENT GROUNDING CONNECTION <br />GROUNDING STRAP <br />TELECOMMUNICATIONS DEVICE <br />(X = REPRESENTS THE # OF TELECOMMUNICATIONS MODULES) <br />(W = TELECOMMUNICATIONS WALL PHONE MTD AT +48" AFF) <br />(B = BLANK COVER PLATE) <br />x1 (F = MODULAR FURNITURE DEVICE) <br />Y (AC = ABOVE COUNTER DEVICE) <br />(S = SURFACE MOUNT) <br />(WAP = WALL MOUNTED WIRELESS ACCESS POINT DATA DEVICE) <br />ABOVE CEILING TELECOMMUNICATIONS DEVICE <br />(X = REPRESENTS THE # OF TELECOMMUNICATIONS MODULES) <br />P(WAP = WIRELESS ACCESS DEVICE) <br />(SV = SECURITY VIDEO CAMERA) <br />FIRE RESISTANT 3/4" PLYWOOD BACKBOARD <br />TWO -POST EQUIPMENT RACK <br />3.65" DOUBLE -SIDED VERTICAL MANAGEMENT <br />6" DOUBLE -SIDED VERTICAL MANAGEMENT <br />12" DOUBLE -SIDED VERTICAL MANAGEMENT <br />WALL MOUNTED ENCLOSURE <br />FLOOR MOUNTED SERVER ENCLOSURE <br />110 BLOCK WITH LEGS <br />66 BLOCK <br />ACCESS CONTROL TE <br />ACCESS CONTROL PANEL <br />ACP �(C = CONTROLLER, CONNECTED TO NETWORK) <br />(X)AS = SUBCONTROLLER, CONNECTED VIA RS-485) <br />CREDENTIAL/ CARD READER <br />S (CR = CARD READER, WALL MOUNTED) <br />CR (CR/P = CARD READER W/PIN, WALL MOUNTED) <br />(CR/M = CARD READER, MULLION MOUNTED) <br />cR INTEGRATED CARD READER/ WIRELESS DOOR <br />HARDWARE <br />PIM WIRELESS PANEL INTERFACE MODULE <br />DOOR POSITION SWITCH <br />S _ --(S = SURFACE MOUNTED) <br />El DOOR ENTRY STATION, WALL MOUNTED <br />MS DOOR MASTER STATION, DESK TOP <br />SECURITY BUTTONS/SWITCH, \/\/ALL MOUNTED <br />(AO = AUTO OPERATOR) <br />S (DR = DOOR RELEASE) <br />XX (LD = LOCKDOWN) <br />(KS = KEYED SWITCH <br />(PB = PANIC/ DURESS) <br />SECURITY BUTTONS, UNDER DESK MOUNTED <br />® (DR = DOOR RELEASE) <br />(LD = LOCKDOWN) <br />(PB = PANIC/ DURESS) <br />R' REQUEST TO EXIT DETECTOR, °J1/ALL MOUNTED <br />R, REQUEST TO EXIT DETECTOR, CEILING MOUNTED <br />R REQUEST TO EXIT, INTEGRAL MACRO SWITCH <br />R REQUEST TO EXIT BUTTON, WALL MOUNTED <br />s HORN, WALL MOUNTED <br />s STROBE, WALL MOUNTED <br />s STROBE/ SIREN, CEILING MOUNTED <br />�S DOOR HARDWARE POWER SUPPLY (DIV 08) <br />X (X = QUANTITY OF DOORS) <br />EL ELECTRIFIED HARDWARE <br />(EL = ELECTRIFIED LOCKSET/EXIT DEVICE) <br />(ES = ELECTRIFIED STRIKE) <br />(ML = ELECTRIFIED MAGNETIC LOCK) <br />(MH = ELECTRIFIED MAGNETIC HOLD OPEN) <br />GENERAL (NOTES <br />ABBREVIATIONS <br />DRA I INDEX <br />EME ST0.1 SECURITY AND TELECOM( LEGEND AND <br />1. <br />PERFORM WORK IN ACCORDANCE WITH <br />A <br />AMIIPERE <br />MAXMAXIMUM <br />DRAWING INDEX <br />APPLICABLE NATIONAL AND STATE CODES AS <br />AC <br />AIR CONDITIONING; ALTERNATING CURRENT; <br />MC <br />MAIN CROSS CONNECT; METAL CLAD (CABLE) <br />AMENDED LOCALLY AND ENFORCED BY THE AHJ. <br />ABOVE COUNTER <br />MCC <br />MOTOR CONTROL CENTER <br />EME ST2.1 SECURITY AND TELECOM FLOOR PLAN <br />AF <br />AMP FUSE; AMP FRAME <br />MCB <br />MAIN CIRCUIT BREAKER <br />EME ST8.1 SECURITY AND TELECOM DETAILS <br />2. <br />OBTAIN AND PAY FOR PERMITS REQUIRED FOR <br />AFF <br />ABOVE FINISHED FLOOR <br />INSTALLATION OF WORK. ARRANGE AND <br />AG <br />ABOVE GRADE <br />MIDF <br />MAIN DISTRIBUTION FRAME <br />SCHEDULE REQUIRED INSPECTIONS. <br />MDP <br />MAIN DISTRIBUTION PANEL <br />AHJ <br />AUTHORITIES HAVING JURISDICTION <br />MFR <br />MANUFACTURER <br />3. <br />DEVICE LOCATIONS ARE APPROXIMATE. <br />AHU <br />AIR HANDLING UNIT <br />MH <br />MANHOLE <br />COORDINATE DEVICE LOCATIONS AND ELEVATIONS <br />AIC <br />AMPERE INTERRUPTING CURRENT <br />MIN <br />MINIMUM <br />WITH APPROPRIATE DOCUMENTS INCLUDING SHOP <br />AL <br />ALUMINUM <br />MLO <br />FAIN LUGS ONLY <br />DRAWINGS AND ARCHITECT'S INTERIOR <br />ANSI <br />AMERICAN NATIONAL STANDARDS INSTITUTE <br />MM <br />MULTIMODE <br />ELEVATIONS PRIOR TO ROUGH -IN. <br />AS <br />AMP SWITCH <br />MPOE <br />MAIN POINT OF ENTRY <br />4. <br />DEMOLISH EXISTING SYSTEMS AS INDICATED ON <br />AT <br />AMP TRIP <br />MPOP <br />MAIN POINT OF PRESENCE <br />PLANS OR AS REQUIRED FOR INSTALLATION OF <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />MTD <br />MOUNTED <br />NEW WORK. MATERIAL SHALL BE REMOVED FROM <br />ATM <br />ASYNCHRONOUS TRANSFER MODE <br />MTS <br />MANUAL TRANSFER SWITCH <br />SITE AND LEGALLY DISPOSED OF OFF SITE UNLESS <br />AV <br />AUDIO VISUAL <br />OTHERWISE DIRECTED. RETURN ITEMS TO OWNER <br />AWG <br />AMERICAN WIRE GAUGE <br />(N) <br />NEW <br />IN EXISTING CONDITION WHEN DIRECTED BY <br />OWNER. <br />N <br />NEUTRAL <br />BAS <br />BUILDING AUTOMATION SYSTEM <br />NAC <br />NOTIFICATION APPLIANCE CIRCUIT <br />5. <br />COMPLETION OF WORK SHALL BE EXECUTED IN <br />BATT <br />BATTERIES <br />NEC <br />NATIONAL ELECTRICAL CODE <br />ACCORDANCE WITH THE PROJECT SCHEDULE. <br />BKBD <br />BACKBOARD <br />NATIONAL ELECTRICAL MANUFACTURERS <br />SCHEDULE INSTALLATION WITH OTHER TRADES TO <br />BIL <br />BASIC IMPULSE INSULATION LEVEL <br />NEMA <br />ASSOCIATION <br />ENSURE PROJECT MILESTONES ARE MET, <br />BKR <br />BREAKER <br />NF <br />NON -FUSED <br />BLDG <br />BUILDING <br />NIC <br />NOT IN CONTRACT <br />6. <br />DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW <br />NL <br />NIGHT LIGHT <br />ALL COMPONENTS REQUIRED FOR A COMPLETE <br />INSTALLATION. PROVIDE COMPONENTS REQUIRED <br />C <br />CONDUIT; DEGREES CELSIUS <br />FOR COMPLETE AND OPERATIONAL SYSTEMS <br />CAB <br />CABINET <br />OFC <br />OPTICAL FIBER CABLE <br />INCLUDING RACEWAYS, CONDUCTORS, BOXES, <br />CAT <br />CATEGORY <br />OHL <br />OVERHEAD LINE <br />SUPPORTS AND SIMILAR ITEMS. <br />CATV <br />COMMUNITY ANTENNA TELEVISION <br />OL <br />OVERLOAD <br />CB <br />CIRCUIT BREAKER <br />OS <br />OCCUPANCY SENSOR <br />7. <br />LOCATIONS OF RACEWAY, PATHWAY AND SIMILAR <br />CCTV <br />CLOSED CIRCUIT TELEVISION <br />OSP <br />OUTSIDE PLANT <br />ITEMS ARE SHOWN SCHEMATICALLY. COORDINATE <br />INSTALLATION, INCLUDING BUT NOT LIMITED TO <br />CLG <br />CEILING <br />CABLING, TELECOMMUNICATION PATHWAYS AND <br />CM <br />CEILING -(MOUNTED <br />P <br />POLE <br />SPACES, AND EXACT LOCATION OF HORIZONTAL <br />CO <br />CONDUIT ONLY <br />PBX <br />PRIVATE BRANCH EXCHANGE <br />AND BACKBONE CABLING WITH LOCATIONS OF <br />COW <br />COMPUTER ON WHEELS <br />PF <br />POWER FACTOR <br />FIXED CASEWORK AND BUILDING CONDITIONS <br />CR <br />CONTROLLED RECEPTACLE <br />PH <br />PHASE <br />AFFECTING THE WORK OF THIS CONTRACT. <br />CT <br />CURRENTTRANSFORMER <br />PIR <br />PASSIVE INFRARED <br />8. <br />COORDINATE TELECOMMUNICATIONS/ SECURITY <br />CU <br />COPPER <br />PIV <br />POST INDICATING VALVE <br />WORK WITH THAT OF OTHER TRADES. REFER TO <br />PNL <br />PANEL <br />ELECTRICAL, ARCHITECTURAL DRAWINGS AND <br />DDC <br />DIRECT DIGITAL CONTROL <br />PP <br />PATCH PANEL <br />SPECIFICATIONS. COORDINATION SHALL OCCUR <br />DEMARC <br />DEMARCATION POINT <br />PT <br />POTENTIAL TRANSFORMER <br />PRIOR TO FABRICATION, PURCHASE, AND <br />DISC <br />DISCONNECT <br />PVC <br />POLYVINYL CHLORIDE <br />INSTALLATION OF WORK. <br />DIST <br />DISTRIBUTION <br />0. <br />NEW CABLING INSTALLATIONS SHALL BE <br />DSL <br />DIGITAL SUBSCRIBER LINE <br />RCP <br />REFLECTED CEILING PLAN <br />CONCEALED IN WALL, CEILINGS, AND BELOW <br />DWG <br />DRAWING <br />REC <br />RECEPTACLE <br />RAISED FLOOR SPACES UNLESS OTHERWISE <br />REF <br />REFER TO <br />NOTED ON THE DRAWINGS. CABLING IN <br />(E) <br />EXISTING <br />REV <br />REVISION <br />ACCESSIBLE CEILING SPACES SHALL BE INSTALLED <br />EA <br />EACH <br />RM <br />ROOM <br />AS OPEN CABLING NEAR STRUCTURES AND WALLS <br />EF <br />EXHAUST FAN <br />RU <br />RACK UNIT <br />OR AS SPECIFICALLY NOTED ON DRAWINGS. SEE <br />SPECIFICATIONS FOR SUPPORT REQUIREMENTS. <br />EIA <br />ELECTRONIC INDUSTRIES ASSOCIATION <br />ELEV <br />ELEVATION <br />SHT <br />SHEET <br />10. <br />PROVIDE FIRESTOPPING SYSTEMS FOR CONDUIT <br />EM <br />EMERGENCY <br />SLC <br />SIGNALING LINE CIRCUIT <br />AND RACEWAY SYSTEMS AT PENETRATIONS, <br />EMT <br />(ELECTRICAL METALLIC TUBING <br />SM <br />SINGLEMODE <br />SLEEVES AND SLOTS OF FIRE RATED <br />ENCL <br />ENCLOSURE <br />SMFC <br />SURFACE -MOUNTED OPTICAL FIBER CABINET <br />CONSTRUCTION FOR HORIZONTAL PATHWAYS AND <br />EPM <br />ELECTRONIC POWER METER <br />SMR <br />SURFACE METAL RACEWAY <br />SPACES. <br />EPO <br />EMERGENCY POWER OFF <br />SONET <br />SYNCHRONOUS OPTICAL NETWORK <br />11. <br />MINIMUM SPACING FROM ELECTRICAL APPARATUS <br />EQUIP <br />EQUIPMENT <br />SP <br />SERVICE PROVIDER <br />SUCH AS MOTOR DRIVEN EQUIPMENT AND <br />ETR <br />EXISTING TO REMAIN <br />SPD <br />SURGE PROTECTIVE DEVICE <br />TRANSFORMERS SHALL BE 6-0". SPACING <br />EWC <br />ELECTRIC WATER COOLER <br />SPEC <br />SPECIFICATIONS <br />REQUIREMENTS SHALL APPLY TO OPEN CABLING <br />SPST <br />SINGLE POLE SINGLE THROW <br />PATHWAYS WHERE EQUIPMENT IS LOCATED ON <br />F <br />FUSE; DEGREES FAHRENHEIT <br />ST <br />SHUNT TRIP <br />THE SAME FLOOR, FLOOR ABOVE, FLOOR BELOW, <br />FA <br />FIRE ALARM( <br />STP <br />SHIELDED TWISTED PAIR <br />OR IN ROOMS ADJACENT TO SUCH EQUIPMENT AS <br />THOUGH WALLS AND FLOORS DID NOT EXIST. <br />FAAP <br />FIRE ALARM ANNUNCIATOR PANEL <br />SVGA <br />SUPER VIDEO GRAPHICS ARRAY <br />EXCEPTION: BUILDING CONSTRUCTION THAT <br />FACP <br />FIRE ALARM",( CONTROL PANEL <br />SW <br />SWITCH <br />RESULTS IN CONTINUOUS METALLIC BARRIER <br />FBO <br />FURNISHED BY OWNER <br />SWBD <br />SWITCHBOARD <br />BETWEEN ELECTRICAL APPARATUS AND CABLE <br />FOIC <br />FURNISHED BY OWNER INSTALLED BY <br />PATHWAYS SHALL BE CONSIDERED AS SUITABLE <br />CONTRACTOR <br />TBB <br />TELECOMMUNICATIONS BONDING BACKBONE <br />SEPARATION. <br />FOIO <br />FURNISHED BY OWNER INSTALLED BY OWNER <br />TEL <br />TELEPHONE <br />FSD <br />FIRE SMOKE DAMPER <br />TELCO <br />TELEPHONE COMPANY <br />12. <br />PRIOR TO STARTING TELECOMMUNICATIONS/ <br />SECURITY INSTALLATION, CAREFULLY INSPECT <br />TGB <br />TELECOMMUNICATIONS GROUNDING BUSBAR <br />INSTALLED WORK OF OTHER TRADES AND VERIFY <br />G <br />GROUND <br />TIA <br />TELECOMMUNICATIONS INDUSTRY ASSOCIATION <br />THAT SUCH WORK IS COMPLETE TO THE POINT <br />GF <br />GROUND FAULT CIRCUIT INTERRUPTER <br />TMGB <br />TELECOMMUNICATIONS MAIN GROUNDING <br />WHERE WORK MAY PROPERLY COMMENCE. <br />GFP <br />GROUND FAULT PROTECTION <br />BUSBAR <br />NOTIFY THE ARCHITECT AND ENGINEER IN WRITING <br />GND <br />GROUND <br />TP <br />TAMPERPROOF <br />OF CONDITIONS DETRIMENTAL TO THE PROPER <br />GRS <br />GALVANIZED RIGID STEEL <br />TR <br />TELECOMMUNICATIONS ROOM <br />AND TIMELY COMPLETION OF THE WORK. <br />TTB <br />TELEPHONE TERMINAL BOARD <br />13. <br />DO NOT BEGIN TELECOMMUNICATIONS/ SECURITY <br />HC <br />HORIZONTAL CROSS CONNECT <br />TV <br />TELEVISION <br />INSTALLATION UNTIL UNSATISFACTORY <br />HID <br />HIGH INTENSITY DISCHARGE <br />TVSS <br />TRANSIENT VOLTAGE SURGE SUPPRESSION <br />CONDITIONS ARE RESOLVED. BEGINNING WORK <br />HP <br />HORSEPOWER <br />TYP <br />TYPICAL <br />CONSTITUTES ACCEPTANCE OF CONDITIONS AS <br />HTR <br />HEATER <br />SATISFACTORY <br />Hz <br />HERTZ <br />UG <br />UNDERGROUND <br />UL <br />UNDERWRITERS LABORATORIES <br />14. <br />ROUTE CATEGORY 6/6A CABLES TO THEIR <br />IC <br />INTERMEDIATE CROSS CONNECT <br />UON <br />UNLESS OTHERWISE NOTED <br />ASSIGNED CROSS -CONNECT AND TERMINATE <br />CABLES ON 48-PORT PATCH PANELS ON RACKS <br />IBC <br />INTERNATIONAL BUILDING CODE <br />UPS <br />UNINTERRUPTIBLE POWER SUPPLY <br />UNLESS OTHERWISE NOTED. <br />IDF <br />INTERMEDIATE DISTRIBUTION FRAME <br />USB <br />UNIVERSAL SERIAL BUS <br />IEEE <br />INSTITUTE OF ELECTRICAL AND ELECTRONIC <br />UTP <br />UNSHIELDED TWISTED PAIR <br />15. <br />ROUTE SECURITY CABLES TO THEIR ASSIGNED <br />ENGINEERS <br />UV <br />UNIT VENTILATOR <br />PANELS. <br />IG <br />ISOLATED GROUND <br />IMC <br />INTERMEDIATE METALLIC CONDUIT <br />V <br />VOLTS <br />16. <br />THE ELECTRICAL CONTRACTOR SHALL PROVIDE <br />ISDN <br />INTEGRATED SERVICES DIGITAL NETWORK <br />VA <br />VOLT AMPERES <br />ALL CONDUIT, OUTLET BOXES, JUNCTION BOXES, <br />RACEWAY SYSTEMS, ETC. FOR A COMPLETE AND <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />OPERATIONAL PATHWAY SYSTEM FOR ALL <br />J <br />JUNCTION <br />TELECOMMUNICATIONS SYSTEMS PER THE SCOPE <br />W <br />WATT; WIRE <br />OF WORK INDICATED ON THE CONSTRUCTION <br />kVA <br />KILOVOLT AMPERE <br />W/ <br />WITH <br />DRAWINGS AND BID SPECIFICATIONS. <br />kW <br />KILOWATT <br />W/O <br />WITHOUT <br />KCMIL <br />THOUSAND CIRCULAR MILS <br />WA <br />WORKSTATION AREA <br />KVAR <br />KILOVOLT AMPERE REACTIVE <br />WAN <br />WIDE AREA NETWORK <br />WG <br />WIRE GUARD <br />LAN <br />LOCAL AREA NETWORK <br />WH <br />WATT HOUR METER <br />LCP <br />LIGHTING CONTROL PANEL <br />WP <br />WEATHERPROOF <br />LEC <br />LOCAL EXCHANGE CARRIER <br />LT <br />LIGHT <br />XMFR <br />TRANSFORMER <br />LTG <br />LIGHTING <br />Y <br />WYE <br />M <br />METER <br />ALL SYMBOLS MAY APPEAR ON THE DRAWINGS <br />MAN <br />METROPOLITAN AREA NETWORK <br />Z <br />IMPEDANCE <br />SECURITY ROUGH -IN SCHEDULE <br />SYMBOL <br />j MOUNTING HEIGHT <br />DEVICE NAME <br />OUTLET BOX <br />CONDUIT <br />MUD RING <br />DETAIL <br />NOTES <br />QTY <br />SIZE <br />QT�° <br />SIZE <br />TERM LOCATION <br />S <br />CR <br />+48", LION <br />CARD READER <br />1 <br />4"S <br />1 <br />3/4" <br />ACCESSIBLE CLG <br />SINGLE GANG <br />2/ST8.2 <br />- <br />s <br />- <br />DOOR POSITION SWITCH <br />- <br />- <br />1 <br />3/4" <br />ACCESSIBLE CLG <br />- <br />i <br />2/ST8.2 <br />2 <br />S <br />LD <br />+48" OR <br />ABOVE COUNTER <br />LOCKDOWN BUTTON <br />1 <br />4"S <br />1 <br />3/4" <br />ACCESSIBLE CLG <br />SINGLE GANG <br />- <br />- <br />RR <br />UNDER DESK <br />DOOR RELEASE BUTTON <br />1 <br />4"S <br />1 <br />3/4" <br />ACCESSIBLE CLG <br />SINGLE GANG <br />- <br />- <br />EL <br />_ <br />ELECTRONIC LOCKSET/ EXIT <br />DEVICE <br />_ <br />1 <br />3/4" <br />ACCESSIBLE CLG <br />- <br />2/ST8.2 <br />2 <br />MH <br />+78'° <br />i <br />MAGNETIC DOOR HOLD OPEN <br />- <br />- <br />1 <br />' <br />3/4°' <br />ACCESSIBLE CLG <br />- <br />1/ST8.2 <br />2 <br />CAMERA <br />1 <br />4"S <br />1 <br />3/4" <br />ACCESSIBLE CLG <br />SINGLE GANG <br />- <br />- <br />c <br />CEILING <br />i <br />CAMERA <br />1 <br />4"S <br />1 <br />3/4" <br />ACCESSIBLE CLG <br />SINGLE GANG <br />- <br />' <br />- <br />GENERAL NOTE: MOUNTING HEIGHTS INDICATED ON THE SCHEDULE REFER TO CENTER OF BACK BOX. <br />NOTE 1: DEVICE REQUIRES NETWORK CONNECTION, PROVIDE CATEGORY 6 CABLING (CABLING BY 271100). <br />NOTE 2: COORDINATE REQUIREMENTS WITH DOOR HARDWARE. <br />R </ <br />06.4a8. v .__ <br />_4 <br />9 <br />I <br />s� <br />a <br />Ipsd <br />is <br />uj <br />uj <br />18-1041 <br />WE <br />3-8-18 <br />DB <br />CHEDW By <br />PS <br />AND <br />TELECOM I C '♦ ' D <br />D�,'i'' I <br />