Laserfiche WebLink
AA UNSECURE SIDE <br />ll�/� I <br />ELEVATION A —A ELEVATION B—B <br />UNSECURE SIDE SECURE SIDE <br />SECURE SIDE BB <br />SECURE SIDE BB <br />NOW <br />ELEVATION — AA <br />UNSECURE SIDE <br />ralatIM rim <br />1 8A\0 <br />1i 8AWG—o <br />O/A SHII <br />1. WIRE GAUGES NOTED ARE MINIMUM GAUGE <br />REQUIREMENTS. COORDINATE GAUGE REQUIREMENTS <br />WITH MANUFACTURER BASED ON ACTUAL WIRE LENGTHS <br />2. DETAIL SHOWN IS ATYPICAL ELEVATION, REFER TO <br />FLOOR PLANS FOR EXACT DOOR ORIENTATION, DEVICE <br />TYPES AND DEVICE PLACEMENTS RELATIVE TO DOOR <br />POSITION AND SWING. <br />3. CONDUIT SHALL BE 3/4" EMT UNLESS NOTED OTHERWISE. <br />4. DIVISION 26 & 28 SHALL PROVIDE CONDUIT AND CABLING <br />AS INDICATED. <br />WIRE � <br />GAUGE, <br />1 <br />1 ADA AUTO OPERATOR BUTTON (WHERE APPLICABLE) <br />QDOOR ENTRY STATION WITH CAMERA (WHERE <br />APPLICABLE) <br />3 CARD READER SHALL BE MOUNTED ON UNSECURE SIDE <br />OF DOOR <br />4 DOOR POSITION SWITCH SHALL BE RECESSED IN DOOR <br />FRAME <br />5 ELECTRIFIED LOCKSET OR ELECTRIFIED EXIT DEVICE, <br />FURNISHED BY DIV. 08 <br />6 CABLE TO DOOR HARDWARE AND/OR INTEGRAL REX <br />7 POWER TRANSFER HINGE/ ARMORED CABLE, SEE DIV. 08 <br />FOR ADDITIONAL INFORMATION <br />ROUGH —IN/ BACK BOX FOR CABLING TO DOOR FRAME <br />9 ELECTRIFIED MAGNETIC HOLD OPEN DEVICE, FURNISHED <br />BY DIV. 08 <br />E N G I N E E R S <br />� 1 <br />{ <br />I <br />`mm.,n.,,.w...» ter.......-�, ... .._.„-. <br />.m ...a.rr...-rn <br />�:r......c„exrc-,>•,k <br />LLJ <br />0-01 <br />18-1041 <br />WE <br />3-8-18 <br />owm By <br />DB <br />PS <br />