Laserfiche WebLink
L �; I ' J <br />IN`� `' ���;�`-_n.40 <br />1 +26.7, 79.4' LT <br />6" SIDE SEWER CO <br />48" SADDLE MH <br />PER C.O.E. STD <br />DWG 605A <br />ED <br />RE=561,6+ <br />IE=553.61 + <br />(CALGD IE) <br />1" IRRIGATION WATER LINE WITH 1" METER <br />4" WATER SERVICE LINE WITH 4" METER (2 <br />METERS) PER C.O.E. STD DWG 502C & 5036 <br />074, <br />17 <br />-8%8*''GVMJxMJxMJTEE <br />6" GV MJ x MJ (1 EA <br />TAPPING TEE BY CITY <br />i ,, <br />-r <br />T, <br />I <br />11+87: <br />+` II <br />Y <br />,\ <br />� <br />I � <br />f <br />I <br />' _ <br />P <br />F <br />a° <br />VA I` <br />- 11+00 4- <br />UJI 2 , <br />i< <br />Lv <br />fa <br />I <br />i <br />I <br />L <br />1 <br />`6a <br />SS 2,f6o% (MIN) <br />12 <br />' I <br />f <br />I � I <br />2 I <br />I 1 <br />h, A1' <br />�Y I <br />p ZCl- <br />}I <br />X <br />+40 <br />a <br />0 <br />E <br />J <br />E <br />WATER DISTRIBUTION NOTES <br />A. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY MEANS OF AN APPROVED BACKFLOW <br />PREVENTION DEVICE PRIOR TO SATISFACTORY FLUSHING, TESTING, DISINFECTION, AND RECEIPT OF <br />SATISFACTORY BACTERIOLOGICAL TEST RESULTS. <br />B. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE BY THE PUBLIC WORKS DEPARTMENT AT THE <br />DEVELOPER'S EXPENSE. THE PUBLIC WORKS DEPARTMENT SHALL BE GIVEN AT LEAST 5 BUSINESS DAYS NOTICE <br />FOR EACH CONNECTION, THE PUBLIC WORKS DEPARTMENT SHALL THEREAFTER DETERMINE THE DATE AND TIME <br />AT WHICH THE CONNECTION SHALL BE MADE, <br />C. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT STANDARDS. <br />D. A PRE -CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO THE START OF CONSTRUCTION. THE <br />CITY OF EVERETT PUBLIC WORKS CONSTRUCTION DIVISION MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR TO <br />COMMENCEMENT OF CONSTRUCTION. <br />E. THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED AGENT SHALL NOTIFY THE PUBLIC WORKS DEPARTMENT OF <br />A PERSON WHO CAN BE CONTACTED REGARDING PROBLEMS DURING CONSTRUCTION ON A 24 HOUR BASIS. <br />F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL SEPARATION BETWEEN POTABLE AND <br />NON -POTABLE CONVEYANCE SYSTEMS, <br />G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBLIC WORKS DEPARTMENT PERSONNEL ONLY, ALL <br />VALVES, NEW AND EXISTING, SHALL BE ACCESSIBLE AT ALL TIMES. <br />H. FIRE FLOW FOR THIS PROJECT IS 1,500 GPM, <br />1. THIS SITE CONTAINS A PRIVATE FIRE SUPPRESSION (SPRINKLER) SYSTEM. <br />J. ALL BENDS, TEES AND FITTINGS SHALL BE RESTRAINED PER 2012 CITY OF EVERETT DESIGN AND CONSTRUCTION <br />STANDARDS 5-13. MEGA -LUG OR COE APPROVED EQUAL FIELD LOCK/RESTRAINTS ARE REQUIRED, RESTRAINING <br />LENGTH SHALL BE DETERMINED PER TABLE 5A "HORIZONTAL THRUST RESTRAINT LENGTH". <br />NW1 /4, NW1 /4, SEC 24, TWN 28 N, RNG 4 E, EVERETT WA, WM <br />E x FH,, <br />(96 TO FDC) <br />SANITARY SEWER NOTES <br />1. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT STANDARDS AND <br />WSDOT/APWA STANDARD SPECIFICATION. <br />2. NO PART OF THE SANITARY SEWER SYSTEM SHALL BE COVERED, CONCEALED OR PUT <br />INTO USE UNTIL IT HAS BEEN TESTED, INSPECTED, AND APPROVED BY THE CITY <br />INSPECTOR. <br />3. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM AVAILABLE <br />RECORDS AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR VERIFICATION OF LOCATIONS AND TO AVOID DAMAGE TO ANY <br />ADDITIONAL UTILITIES NOT SHOWN. IF CONFLICTS WITH EXISTING UTILITIES ARISE DURING <br />CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR AND <br />ANY CHANGES REQUIRED SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO <br />COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT, <br />4. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN EASEMENTS MUST <br />BE STAKED BY SURVEY FOR LINE AND GRADE PRIOR TO STARTING CONSTRUCTION. <br />C.O.E. STANDARD DRAWING REFERENCES: <br />1. FOR 1" WATER SERVICE SPECIFICATIONS, SEE STD DWG 502C. <br />2. FOR 3" WATER SERVICE SPECIFICATIONS, SEE STD DWG 503B. <br />3. FOR WATER VALVE SPECIFICATIONS, SEE STD DWG 504. ,. <br />4. FOR FIRE HYDRANT ASSEMBLY DETAILS, SEE STD DWG 507, 509 & 510, <br />5. FOR TAPPING TEE DETAILS, SEE STD DWG 514, <br />6. FOR DCV ASSEMBLY DETAILS, SEE STD DWG 515, 516 & 520. <br />7. FOR TYPICAL SIDE SEWER CONNECTION DETAILS, SEE STD DWG 602. <br />8. FOR TYPICAL SIDE SEWER CLEANOUT DETAILS, SEE STD DWG 604. <br />9. FOR TYPICAL TRENCH SECTION DETAILS, SEE STD DWG 610,611 & 615. <br />Tabie:5A <br />Horizontal' Thrust' Restraint Lenefh <br />Fitting <br />Pi Diameter <br />Length to be Restrained in Each <br />Direction <br />11-114°bend <br />5' <br />5' <br />10' <br />22-1/20 bend <br />10, <br />10, <br />15' <br />450 bend <br />15' <br />20' <br />25' <br />901 bend <br />35' <br />45' <br />60' <br />Tees (where all legs can be <br />restrained <br />20' <br />25' <br />55' <br />Dead Ends and Tees (where <br />only one ne branch is installed) <br />60' <br />80` <br />115, <br />J cc <br />Lu <br />> J <br />3 � <br />z <br />m W <br />cc <br />FLOOR PER <br />FLANGE CONN. x <br />BUILDING PERMIT77 <br />6" D.I.P. <br />cc <br />Lu <br />'o <br />U <br />Co <br />1"=20' <br />0 10 20 40 <br />LEGEND <br />® <br />WATER METER <br />EX. FIRE HYDRANT <br />pd <br />WATER VALVE <br />-0- <br />UTILITY POLE <br />UTILITY ANCHOR <br />GV <br />GAS VALVE <br />STREET SIGN <br />® <br />EX. CB, TYPE 1 <br />CATCH BASIN TYPE 2 <br />0 <br />SAN SWR. MANHOLE <br />--SS-- <br />SAN. SWR. PIPELINE <br />— s0— <br />STORM DRAIN <br />— W — <br />WATER PIPELINE <br />— OP---- <br />OVERHEAD POWER <br />x --- <br />EXISTING FENCE <br />LEGEND & CITY OF EVERETT <br />STANDARD DRAWING REFERENCES <br />® PROPOSED WATER METER PER CITY OF EVERETT STANDARD DWG 502C <br />EXISTING EDGE OF PAVEMENT. <br />BEND WITH THRUST BLOCK <br />,Nr GATE VALVE PER CITY OF EVERETT STANDARD DWG 504 <br />DOUBLE CHECK VALVE ASSEMBLY (DCVA) FOR 2-1/2" AND SMALLER <br />N SERVICE PER CITY OF EVERETT STANDARD DWG 520 <br />TAPPING TEE <br />SANITARY SEWER CLEANOUT (SSCO) <br />• <br />V PROP. F.H. <br />PLAN APPROVED <br />Pumc 1o111Lw MTE OL <br />. JrIA i . <br />OROSION PUBLK !VORKS <br />A PUBLir 'LS N'+-tiLi IS <br />REQUIRED tie t Tr ARTING <br />ANY CON 51ON g I -HIS <br />J PROIEC re; NUUyAL to>= THIS <br />UL LISTED FIRE PUMPER PROJF1- ,s CIIN >rT1U,,;AL PER <br />T CURRENT CITY STANDARDS AND <br />CONNECTION AND UL LISTED PIkES a., _9_=4d <br />uWi BREAK AWAY CAPS --,-- PERMIT FOR consrrttlCfsoN MI <br />JO CiiY Fail set" ISSUED. <br />r, <br />M <br />6" D.I.P. <br />FL x IP ADAPTOR <br />\-- 6"~90' MJ x FLG BEND <br />6" MJ CL 52 D.I.P. w/MEGA LUGS <br />w/MEGA LUGS <br />FIRE DEPT PUMPER CONNECTION <br />N.T.S. <br />VERTICAL DATUM: NAVD88 <br />NAVD88 - 3.586' = NGVD29 <br />NGVD1929 MONUMENT U 406, BRASS <br />CAP IN FOUNDATION OF THE TRAFFIC <br />SIGNAL POLE NW CORNER OF THE <br />INTERSECTION OF 100TH & EVERGREEN <br />WAY ELEVATION 569.49' <br />LINE MEASURES 1" AT <br />FULL SIZE PLOT <br />I----- I <br />IF SHEET SIZE IS OTHER <br />THAN 22"X34° ADJUST <br />SCALE ACCORDINGLY MiL I <br />0 <br />W <br />0 <br />tL <br />rL <br />0 <br />0 <br />M <br />#k <br />W <br />U <br />Z <br />Q <br />tY <br />to <br />0 <br />CV <br />LO <br />e <br />d <br />REVISIONS <br />C C <br />o W N <br />W <br />0 <br />N , h <br />uj <br />Z W <br />ti h <br />— Lrj�, <br />o00 <br />Z _ <br />COwoo <br />CO <br />�`�� <br />W to <br />U. <br />Z <br />0 <br />4 <br />cm <br />00 <br />Z <br />00 ,Q <br />W <br />c a <br />00 0 <br />� 31267IST <br />NAL <br />2/06/201. 7 <br />0a <br />Q �: Cn <br />z <br />Z�Z4% <br />O <br />J <br />W <br />U Ir M <br />a <br />> Z <br />CC <br />Lu <br />TWO <br />n <br />0�u <br />W <br />di <br />1� <br />W <br />U) <br />J <br />Z <br />a> <br />cc a0 <br />W <br />LLI •� <br />Cn <br />W <br />DRAWN BY: <br />GTR <br />CHKD BY: <br />MER <br />DATE: 06/29/2016 <br />14-063 <br />i <br />Know what's below. <br />Call before you dig, <br />C3uO <br />