My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12115 19TH AVE SE 2020 THE LAKEHOUSE APARTMENTS Plans 2023-07-03 (2)
>
Address Records
>
19TH AVE SE
>
12115
>
THE LAKEHOUSE APARTMENTS
>
Plans
>
12115 19TH AVE SE 2020 THE LAKEHOUSE APARTMENTS Plans 2023-07-03 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2023 11:44:16 AM
Creation date
12/15/2021 8:20:28 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12115
Tenant Name
THE LAKEHOUSE APARTMENTS
Permit
B2010-033
Year
2020
Notes
New exterior gazebo added near pool deck
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />0 <br />m <br />T <br />r <br />CD <br />CV <br />0 <br />N <br />O <br />1 2 <br />ABBREVIATIONS: <br />< <br />ANGLE <br />FAST <br />FASTENER <br />PIP <br />POURED IN PLACE <br />@ <br />AT <br />FB <br />FLAT BAR <br />Pi <br />PANEL JOINT <br />F <br />+ <br />AND <br />FBO <br />FURNISHED BY OTHERS <br />PL <br />PROPERTY LINE <br />AB <br />ANCHOR BOLT <br />FID <br />FLOOR DRAIN <br />P. LAM <br />PLASTIC LAMINATE <br />A/C <br />AIR CONDITIONING <br />FDN <br />FOUNDATION <br />PLAS <br />PLASTER <br />ACT <br />ACOUSTICAL CEILING TILE <br />FE <br />FIRE EXTINGUISHER <br />PLYWD <br />PLYWOOD <br />ACOUS <br />ACOUSTICAL <br />FEC <br />FIRE EXTINGUISHER CABINET PR <br />PAIR <br />AD <br />AREA DRAIN <br />FF <br />FINISH FLOOR <br />PREFIN <br />PREFINISHED <br />ADD <br />ADDENDUM <br />FHC <br />FIRE HOSE CABINET <br />PT <br />PRESSURE TREATED <br />ADJ <br />ADJACENT <br />FIN <br />FINISH <br />PTD <br />PAPER TOWEL DISPENSER <br />ADJT <br />ADJUSTABLE <br />FL <br />FLOOR <br />PTDR <br />COMBINATION PAPER <br />A.F.F. <br />ABOVE FINISH FLOOR <br />FLASH <br />FLASHING <br />TOWEL <br />DISPENSER + RECEPTACLE <br />AGG <br />AGGREGATE <br />FLUOR <br />FLUORESCENT <br />PTN <br />PARTITION <br />ALS <br />AREA LIGHT STANDARD <br />FO <br />FACE OF <br />PTR <br />PAPER TOWEL RECEPTACLE <br />ALT <br />ALTERNATE <br />FOC <br />FACE OF CONCRETE <br />PVC <br />POLYVINYL <br />ALUM <br />ALUMINUM <br />FOF <br />FACE OF FINISH <br />PVMT <br />PAVEMENT <br />ANOD <br />ANODIZED <br />FOM <br />FACE OF MASONRY <br />QT <br />QUARRY TILE <br />APPROX <br />APPROXIMATE <br />FOS <br />FACE OF STUD <br />R <br />RISER <br />ARCH <br />ARCHITECTURAL <br />FOTS <br />FACE OF TUBE SECTION <br />R. <br />RADIUS <br />AUTO <br />AUTOMATIC <br />FRT <br />FIRE RETARDANT TREATED <br />RA <br />RETURN AIR <br />A.F.C. <br />ABOVE FINISH CEILING <br />FT <br />FOOT OR FEET <br />RB <br />RUBBER BASE <br />BC <br />BOTTOM OF CURB <br />FTG <br />FOOTING <br />RD <br />ROOF DRAIN <br />BD <br />BOARD <br />FURR <br />FURRING <br />REF <br />REFERENCE <br />E <br />B.F.F. <br />BELOW FINISH FLOOR <br />GA <br />GAUGE <br />REFL <br />REFLECTED <br />BITUM <br />BITUMINOUS <br />GALV <br />GALVANIZED <br />REFR <br />REFRIGERATOR <br />BLDG <br />BUILDING <br />GB <br />GRAB BAR <br />REINF <br />REINFORCED <br />BLK <br />BLOCK <br />GC <br />GENERAL CONTRACTOR <br />RESIL <br />RESILIENT <br />BLKG <br />BLOCKING <br />GI <br />GALVANIZED IRON <br />REQ'D <br />REQUIRED <br />B.M. <br />BENCH MARK <br />GL <br />GLASS <br />REV <br />REVISE OR REVISION <br />B.O. <br />BOTTOM OF... <br />GL <br />GLU LAM <br />RM <br />ROOM <br />BOT <br />BOTTOM <br />GND <br />GROUND <br />RO <br />ROUGH OPENING <br />BRG <br />BEARING <br />GP <br />GALVANIZED PIPE <br />RWL <br />RAIN WATER LEADER <br />B.S. <br />BOTH SIDES <br />GRID <br />GRADE <br />RCP <br />REFLECTED CEILING PLAN <br />BSMT <br />BASEMENT <br />GVP <br />GYPSUM VENEER PLASTER <br />S <br />SOUTH <br />BTWN <br />BETWEEN <br />GWB <br />GYPSUM WALL BOARD <br />Sc <br />SOLID CORE <br />BUR <br />BUILT-UP ROOF <br />GYP <br />GYPSUM BOARD <br />SCD <br />SEAT COVER DISPENSER <br />BPW <br />BED PAN WASHER <br />HB <br />HOSE BIBB <br />SCHED <br />SCHEDULE <br />[ QR C <br />CHANNEL <br />HC <br />HOLLOW CORE <br />SD <br />SOAP DISPENSER <br />CAB <br />CABINET <br />HC <br />HANDICAP PARKING STALL <br />SECT <br />SECTION <br />CB <br />CATCH BASIN <br />HDWD <br />HARDWOOD <br />SGE <br />SEMI -GLOSS ENAMEL <br />CEM <br />CEMENT <br />HDWR <br />HARDWARE <br />SH <br />SHELF <br />CFI <br />CONTRACTOR FURNISHED <br />HM <br />HOLLOW METAL <br />SHTG <br />SHEATHING <br />AND INSTALLED <br />HORIZ <br />HORIZONTAL <br />SHWR <br />SHOWER <br />CG <br />CORNER GUARD <br />HR <br />HOUR ONLY <br />SHT <br />SHEET <br />p <br />C.I. <br />CONTRACTOR INSTALLED <br />H. <br />HEIGHT <br />SIM <br />SIMILAR <br />Cl <br />CAST IRON <br />HVAC <br />HEATING / VENTILATION / AIR <br />SJ <br />SEISMIC JOINT <br />CE <br />CENTER LINE <br />CONDITIONING <br />SL <br />SLIDING <br />CLG <br />CEILING <br />HW <br />HOT WATER <br />SM <br />SHEET METAL <br />CLOS <br />CLOSET <br />ID <br />INSIDE DIAMETER (DIM.) <br />SND <br />SANITARY NAPKINDISPENSER <br />CLR <br />CLEAR <br />INSUL <br />INSULATION <br />SNT <br />SANITARY NAPKINRECEPTACI <br />CJ <br />CONTROL JOINT <br />INT <br />INTERIOR <br />SPEC <br />SPECIFICATION <br />CMU <br />CONCRETE MASONRY UNIT <br />INV <br />INVERT <br />SQ <br />SQUARE <br />COL <br />COLUMN <br />IPS <br />IRON PIPE SIZE <br />SS <br />STAINLESS STEEL <br />COMP <br />COMPOSITION <br />JAN <br />JANITOR <br />S + V <br />STAIN + VARNISH <br />CONC <br />CONCRETE <br />JT <br />JOINT <br />STA <br />STATION <br />CO <br />CONCRETE OPENING <br />JST <br />JOIST <br />STD <br />STANDARD <br />CONN <br />CONNECTION <br />KIT <br />KITCHEN <br />STK <br />STOCK <br />CONST <br />CONSTRUCTION <br />KID <br />KILN DRIED <br />STL <br />STEEL <br />CONT <br />CONTINUOUS <br />L. <br />LENGTH <br />STOR <br />STORAGE <br />CONTR <br />CONTRACTOR <br />LAB <br />LABRTTORY <br />STRUCT <br />STRUCTURAL <br />CORR <br />CORRIDOR <br />LAM <br />LAMINATE <br />SUSP <br />SUSPENDED <br />CR <br />CONTRACTOR ROUGH -IN <br />LAV <br />LAVATORY <br />SYM <br />SYMMETRICAL <br />CRRR <br />CONTRACTOR REMOVED, <br />LB <br />LAG BOLT <br />SYST <br />SYSTEM <br />RELOCATED + REINSTALLED <br />LDW <br />LESS DOOR WIDTH <br />T <br />TREAD <br />CS <br />COUNTERSUNK <br />L.I. <br />LANDSCAPE ISLAND <br />TB <br />TOWEL BAR <br />C <br />CS.J <br />CONSTRUCTION JOINT <br />LKR <br />LOCKER <br />T + B <br />TOP AND BOTTOM <br />CSMT <br />CASEMENT <br />LL <br />LIVE LOAD <br />TOC <br />TOP OF CURB <br />CT <br />CERAMIC TILE <br />LS <br />LANDSCAPING <br />TEL <br />TELEPHONE <br />CTR <br />CENTER <br />LT <br />LIGHT <br />TEMP <br />TEMPERED <br />CW <br />COLD WATER <br />LVR <br />LOUVER <br />T + G <br />TONGUE AND GROOVE <br />DBL <br />DOUBLE <br />MAT'L <br />MATERIAL <br />THK <br />THICK <br />DEMO <br />DEMOLISH <br />MAX <br />MAXIMUM <br />TJ <br />TOOL JOINT <br />DEPT <br />DEPARTMENT <br />MB <br />MACHINE BOLT <br />TP <br />TOP OF PAVEMENT <br />DF <br />DRINKING FOUNTAIN <br />MC <br />MINERAL CORE <br />TPD <br />TOILET PAPER DISPENSER <br />DIA <br />DIAMETER <br />MDO <br />MEDIUM DENSITY OVERLAY <br />TPD(S) <br />SURFACE MOUNTED <br />DIAG <br />DIAGONAL <br />MECH <br />MECHANICAL <br />TOILET PAPER DISPENSER <br />DIM <br />DIMENSION <br />MED <br />MEDIUM <br />TS <br />TUBE SECTION <br />DISP <br />DISPENSER <br />MEMB <br />MEMBRANE <br />TV <br />TELEVISION <br />D.JT <br />DEFLECTION JOINT <br />MEZZ <br />MEZZANINE <br />TOW <br />TOP OF WALL <br />DL <br />DEAD LOAD <br />MFR <br />MANUFACTURER <br />TYP <br />TYPICAL <br />DMT <br />DEMOUNTABLE <br />MH <br />MANHOLE <br />UNFIN <br />UNFINISHED <br />DN <br />DOWN <br />MI <br />MALEABLE IRON <br />UR <br />URINAL <br />DO <br />DOOR OPENING <br />MIN <br />MINIMUM <br />U/CUT <br />UNDER CUT <br />DP <br />DAMPROOFING <br />MIR <br />MIRROR <br />U.N.O. <br />UNLESS NOTED OTHERWISE <br />DR <br />DOOR <br />MISC <br />MISCELLANEOUS <br />VB <br />VAPOR BARRIER <br />DS <br />DOWNSPOUT <br />MO <br />MASONRY OPENING <br />VERT <br />VERTICAL <br />B <br />DSP <br />DRY STANDPIPE <br />MTD <br />MOUNTED <br />VEST <br />VESTIBULE <br />DT <br />DRAIN TILE <br />MTL <br />METAL <br />VFY <br />VERIFY <br />DTL <br />DETAIL <br />MULL <br />MULLION <br />VG <br />VERTICAL GRAIN <br />DWG <br />DRAWING <br />MEDCAB <br />MEDICAL CABINET <br />W <br />WEST <br />0 <br />DIAMETER OR ROUND <br />N <br />NORTH <br />W. <br />WIDTH <br />E <br />EAST <br />NA <br />NOT APPLICABLE <br />W/ <br />WITH <br />EA <br />EACH <br />NAT <br />NATURAL <br />WC <br />WATER CLOSET <br />EF <br />EACH FACE <br />NIC <br />NOT IN CONTRACT <br />W.D. <br />WINDOW DIMENSION <br />E.AGG <br />EXPOSED AGGREGATE <br />NO. OR # <br />NUMBER <br />WD <br />WOOD <br />EJ <br />EXPANSION JOINT <br />NOM <br />NOMINAL <br />WF <br />WIDE FLANGE <br />EL <br />ELEVATION <br />NS <br />NELSON STUD <br />WG <br />WIREGLASS <br />ELEC <br />ELECTRICAL <br />NTS <br />NOT TO SCALE <br />WH <br />WATER HEATER <br />ELEV <br />ELEVATOR <br />NIS <br />NOT IN SHELL ISSUE <br />WDW <br />WINDOW <br />EOS <br />EDGE OF SLAB <br />OA <br />OVERALL <br />W/O <br />WITHOUT <br />ENCL <br />ENCLOSURE <br />OBS <br />OBSCURE <br />WP <br />WATERPROOF <br />ENGR <br />ENGINEER <br />OC <br />ON CENTER <br />WRB <br />WEATHER RESISTAN7BARRIEF <br />EP <br />ELECTRICAL PANEL <br />OD <br />OUTSIDE DIAMETER <br />WRGB <br />WATER RESISTANT GYPSUM <br />EQ <br />EQUAL <br />O.F. <br />OWNER FURNISHED <br />BOARD <br />EQUIP <br />EQUIPMENT <br />O.F.C.I. <br />OWNER FURNISHED <br />WW <br />WATERSTOP <br />ES <br />EACH SIDE <br />OFF <br />OFFICE <br />WSCT <br />WAINSCOT <br />EW <br />EACH WAY <br />OH <br />OVERHEAD <br />WT <br />WEIGHTNCTOR INSTALLED <br />A <br />EDF <br />ELECTRIC DRINKING <br />OPNG <br />OPENING <br />WWF <br />WELDED WIRE FABRIC <br />FOUNTAIN <br />OPP <br />OPPOSITE <br />EXIST <br />EXISTING <br />OS <br />OUTSIDE <br />EXP <br />EXPANSION <br />OR <br />OWNER FURNISHED -INSTALLED <br />EXT <br />EXTERIOR <br />PAR <br />PARALLEL <br />FA <br />FIRE ALARM <br />PC <br />PRECAST <br />I <br />LEGEND OF SYMBOLS: <br />DETAIL IDENTIFICATION <br />XX <br />XX <br />AXXX <br />AXXX <br />SHEET WHERE DRAWN <br />DETAIL <br />I DETAIL VIEW BUBBLE <br />DETAIL IDENTIFICATION <br />MATCH <br />��-- SHEET <br />XX <br />XXXX LOCATION <br />AXXX <br />,- SHEET WHERE DRAWN <br />BUILDING SECTION <br />MATCH LINE REFERENCE <br />—DETAIL IDENTIFICATION <br />DETAIL IDENTIFICATION <br />—CUT <br />�CUT LINE - <br />LINE - <br />DEFINES <br />DEFINES <br />XX THE <br />XX THE DETAILED <br />AXXX DETAILED <br />AXXX ELEMENT <br />'"�---SHEET �ELEMENT�AWN <br />SHEET WHERE DRAWN <br />WALL SECTION <br />DETAIL SECTION <br />DETAIL <br />IDENTIFICATION <br />XX---;,-DETAIL IDENTIFICATION <br />XX <br />XX AXXX XX <br />XX <br />SHEET WHERE <br />-- <br />SHEET WHERE DRAWN <br />XX <br />DRAWN <br />EXTERIOR ELEVATION <br />INTERIOR ELEVATION <br />ROOM NAME <br />XX <br />XXX <br />XXXX-A <br />ROOM NAME & NUMBER <br />DOOR NUMBERS <br />XX <br />X <br />WINDOW NUMBER <br />EQUIPMENT TAG <br />XX <br />X <br />KEY NOTES <br />WALL TYPE <br />E <br />Level 1(Dx <br />0'-0" AFF <br />DATUM ELEVATION <br />REVISION DELTA & CLOUD <br />XX <br />00'-001, <br />FINISH TAG <br />CEILING HEIGHT <br />0'-0" <br />00'-00" XX-XX <br />SPOT ELEVATION <br />FINISH HEIGHT & TYPE <br />TO <br />0'-0" <br />START POINT <br />TOP OF MARK <br />EXTENT OF <br />WORK <br />EXTENT OF WORK <br />DATUM INDICATOR <br />441x"- <br />TRUE <br />NEW GRID EXISTING <br />NORTH <br />GRID <br />NORTH ARROW <br />GRIDLINE BUBBLE <br />NON - RATED <br />1-HOUR RATED <br />2-HOUR RATED <br />3-HOUR RATED <br />4-HOUR RATED <br />PARTITION FIRE RATINGS <br />EXIT SIGN <br />MATERIALS <br />ACOTILE �Oo GRAVEL WOOD <br />MEMBER <br />EMBER <br />J ALUMINUM GYPSUM <br />BOARD <br />BATT PLYWOOD <br />�UV INSULATION <br />CMU OR BRICK RIGID <br />INSULATION <br />CONCRETE SOUND <br />INSULATION <br />EARTH STEEL <br />FINISHED WOOD <br />WOOD I/ BLOCKING <br />5 <br />GENERAL NOTES: <br />1. ALL WORK TO COMPLY WITH THE REQUIREMENTS OF THE AHJ AND THE <br />CURRENT EDITIONS OF LISTED BUILDING CODES. ANY BUILDING OFFICIAL, <br />SUBCONTRACTOR OR TRADES PERSON NOTING DISCREPANCIES SHALL NOTIFY THE <br />DESIGNER IMMEDIATELY UPON DISCOVERY. <br />2. CONTRACTORS SHALL COORDINATE ALL REQUIRED INSPECTIONS BY TFCITY <br />AND ANY OTHER GOVERNING AUTHORITIES AREQUIRED. <br />3. CONTRACTORS SHALL VERIFY AND CONFIRM EXISTING CONDITIORSHOWN OR <br />IMPLIED ON DRAWINGS PRIOR TO THE START OF CONSTRUCTION OR ORDERING <br />MATERIALS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES. <br />4. CONTRACTORS SHALL OBTAIN AND PAY FOR ALL TEMPORARY UTILITIES INCLUDING <br />ELECTRICITY NECESSARY FOR CONSTRUCTION. <br />5. ALL CONSTRUCTION DEBRIS TO BE NEATLY STOCKPILED ON SITE UNTIL DISPOSAL. <br />ALL DEBRIS IS TO BE DISPOSED OF IN LEGAL MANNER AT A LANDFILL OR RECYCLING <br />CENTER. NO DEBRIS IS TO BE DISPOSED OF IN LOCAL WASTE COLLECTION FACILITIES. <br />6. CONTRACTOR SHALL INFORM THE DESIGNER OF ANY AND ALREQUESTED <br />CHANGES. CONTRACTOR SHALL NOT PROCEED WITH REQUESTED CHANGES OR <br />DIRECTIVES WITHOUT PRIOR AUTHORIZATION FROM THE DESIGNER AND A WRITTEN <br />CHANGE ORDER. <br />7. CONTRACTOR SHALL PROVIDE STORAGE FOR ALL BUILDING MATERIALS IN <br />ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. <br />8. ALL SUBSTITUTIONS MUST BE APPROVED BY DESIGNER, ALONG WITH WRITTEN <br />REQUESTS CONTRACTOR SHALL PROVIDE ALL INFORMATION REGARDING THE <br />SUBSTITUTION IN QUESTION, INCLUDING COST. <br />9. SOLID WOOD BLOCKING, INSULATION, OR OTHER FIRE STOP MATERIALS IS TO BE <br />PROVIDED, BETWEEN TOP STORY AND ROOF FACE. <br />10. CONTRACTOR SHALL PROVIDE SAMPLE OF FINISHES AND STAIN COLORS FOR <br />APPROVAL BY DESIGNER. THIS INCLUDES INTERIOR AND EXTERIOR PAINT, AND <br />SHEET ROCK TEXTURES. <br />11. WRITTEN DIMENSIONS AND NOTES ON DRAWING SHALL TAKE PRIORITY OVER SCALE <br />OF DRAWINGS. DO NOT MEASURE DRAWINGS TO DETERMINE ANY DIMENSIONS. <br />DRAWINGS ARE IN SCALE FOR PURPOSES OF DESIGN AND INTENT ONLY. ALL <br />DIMENSIONS SHOWN PLANS ARE FROM AND TO FACE OF FRAMING OR FROM AND TO <br />CENTERLINE OF WALLS, UNLESS OTHERWISE NOTED. <br />12. ALL FEATURES OF THE WORK NOT FULLY SHOWN SHALL BE OF THE SANTYPE <br />AND CHARACTER OF THAT SHOWN FOR SIMILAR CONDITIONS. IN THE EVENT OF THAT <br />ADDITIONAL WORK IS REQUIRED TO COMPLETE THE WORK AS INTENDED OR <br />REQUIRED BY GOVERNING CODES, YET NOT FULLY SHOWN OR OMITTED BY IN THE <br />DRAWINGS, CONTRACTOR'S) MUST STILL PROVIDE FOUNDATION, CARPENTRY, <br />MECHANICAL, ELECTRICAL AND OR/ PLUMBING AS REQUIRED FOR CERTIFICATE OF <br />OCCUPANCY, INCONSISTENCIES, OR DISCREPANCIES. <br />13. VERIFY ALL DIMENSIONS AND MFR. SPECIFICATIONS OF OWNER FURNISHED <br />EQUIPMENT PRIOR TO CONSTRUCTION. <br />14. DO NOT SCALE DRAWINGS. <br />BIDDER DESIGN MECHANICAL <br />ELECTRICAL, AND PLUMBING <br />CRITERIA <br />1. ALL MECHANICAL, ELECTRICAL, AND PLUMBING WORK SHALL BE PROVIDED UNDER <br />A SEPARATE CONTRACT AND PERMIT. SUBMITTALS SHALL BE DEFERRED <br />2. IT IS THE DESIGN/BUILD CONTRACTOR'S RESPONSIBILITY TO CONFORM TO ALL <br />APPLICABLE BUILDING CODES AND TO PROVIDE ALL DOCUMENTATION REQUIRED <br />TO OBTAIN PERMITS FOR WORK UNDER THEIR CONTRACT. <br />3. THE OWNER AND DESIGNER ARE NOT RESPONSIBLE FOR ADDITIONAL COSTS <br />INCURRED DUE TO DESIGN/BUILD CONTRACTOR'S ERROR AND OMISSIONS. <br />4. ELECTRICAL DESIGN CONTRACTOR WILL COORDINATE POWER, SIGNAL AND <br />LIGHTING DESIGN AND PROVIDE CALCULATIONS IN CONFORMANCE WITH STATE <br />ELECTRICAL CODE, ENERGY CODE AND BUILDING CODE. <br />5. ELECTRICAL DESIGN CONTRACTOR WILL REVIEW THE PROGRAM DRAWING AND <br />WILL MEET WITH THE TENANT TO FINALIZE THE EXACT POWER LOCATIONS AND <br />REQUIREMENTS FOR EQUIPMENT. DESIGN WILL PROVIDE FOR CODE REQUIRED <br />AND MAINTENANCE RECEPTACLES. DESIGN WILL INCLUDE FIRE ALARM SYSTEM IF <br />REQUIRED, COORDINATED AND EXTENDED FROM BUILDING FIRE ALARM SYSTEM. <br />OUTLETS, PHONE AND DATA JACKS SHOWN ON ARCHITECTURAL PLANS (IF ANY) <br />ARE MINIMUM REQUIRED AND MAY NOT INCLUDE ADDITIONAL OUTLETS REQUIRED <br />BY CODE OR FOR MAINTENANCE. <br />6. ELECTRICAL DESIGN CONTRACTOR WILL COORDINATE HIS WORK WITH THE <br />ARCHITECT AND WITH THE HVAC AND FIRE SPRINKLER DESIGN/BUILD <br />CONTRACTORS. <br />7. ELECTRICAL DESIGN CONTRACTOR WILL MEET WITH THE TENANT TO DETERMINE <br />AND/OR CONFIRM THE LOCATION OF ALL DATA AND COMMUNICATION <br />CONNECTIONS REQUIRED AND INCLUDE CONDUIT TO 6" ABOVE FIN CLG. BOX AND <br />PULL STRING IN THE REQUIRED LOCATIONS UNDER THE T.I. CONTRACT. <br />8. CONFIRM LIGHTING SWITCHING REQUIREMENTS WITH OWNER <br />9. CONSTRUCTION AND AS -BUILT DRAWINGS TO BE PROVIDED ON ELECTRONIC <br />MEDIA, AUTOCAD RELEASE 14 OR LATER, TO THE ARCHITECT FOR THE OWNER'S <br />RECORDS. <br />10. ELECTRICAL DESIGN/BUILD CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL <br />DEVICES, INCLUDING BUT NOT LIMITED TO: STROBES, ANNUNCIATERS AND EGRESS <br />LIGHTING, REQUIRED BY ALL APPLICABLE CODES. POWER AND LIGHTING <br />DRAWINGS INCLUDED IN THIS DOCUMENT ARE FOR DESIGN PURPOSES ONLY. ANY <br />DEVICE REQUIRED BY CODE OR BY BUILDING OFFICIAL AND NOT INCLUDED IN <br />ELECTRICAL DESIGN/BUILDERS BASE BID SHALL BE INSTALLED AT THE ELECTRICAL <br />DESIGN CONTRACTOR'S EXPENSE. <br />11. GENERAL CONTRACTOR TO COORDINATE POWER AND DATA PLANS WITH OWNER. <br />A <br />7 8 <br />9 <br />Permit#: <br />B2010-033 <br />Site Address: <br />12115 19TH AVE SE GAZEBO <br />Owner: <br />AUK-SILVERLAKE LLC <br />Tenant: <br />AUKUM MANAGEMENT LLC <br />App.Date: <br />10/17/2020 <br />Proposed Use: <br />NEW COMMERCIAL <br />Description: <br />NEW EXTERIOR GAZEBO ADDED NEAR <br />POOL DECK <br />Reviewed B <br />Dated <br />Office Set <br />1ok� Site Set Fire/Planning Set <br />APPROVED <br />PLANNING & COMMUNITY <br />DEVELOPME DEFT <br />BY-.. <br />DATE \®. • 20 2d <br />LAKEHOUSE CLUBHOUSE <br />PERGOLA <br />PROJECT TEAM <br />CLIENT: AUKUM MANAGEMENT <br />E: ANDREW@AUKUM.COM <br />CONTACT: ANDREW WOLPER <br />ARCHITECT OF RECORD WOODBLOCK ARCHITECTURE <br />827 SW 2ND AVE, STE 300 <br />PORTLAND, OR 97204 <br />P: 503.889.0604 <br />CONTACT: ANDRA RIEGLER <br />STRUCTURAL ENGINEER: VLMK ENGINEERING+DESIGN <br />3933 SW KELLY AVE <br />PORTLAND, OR 97239 <br />P: 503.222.4453 <br />CONTACT: KEVIN KAPLAN <br />INTERIOR DESIGNER: COPELAND PDX <br />2641 NE ALBERTA ST <br />PORTLAND OR 97211 <br />E: KAT@COPELANDPDX.COM <br />CONTACT: KATHERINE MAUND <br />PROJECT DATA <br />PROJECT DESCRIPTION <br />NEW PERGOLA NEAR POOL DECK, INCLUDING NEW CONCRETE POUR. <br />CONSTRUCTION TYPE: V-B <br />04 <br />OCCUPANCY: A - ASSEMBLY <br />PROPERTY NAME: LAKEHOUSE APARTMENTS <br />FIRE SPRINKLERS: NONE <br />VICINITY MAP nn��C/�TC�Tr <br />G000 <br />G101 <br />G200 <br />A700 <br />S0.0 <br />S1.0 <br />S2.0 <br />TI 1. G <br />[",'PRO\1ED "`OR THIE �SWANCE OF <br />NKC <br />F`U6I IC\Pj10F,. S, ��9ECHAAL, FIRE <br />UPPPE'6I N, ELUTMCAL O <br />PLUr��U3 � PEHMI. <br />Adaibon,as. erm'ts Are Required <br />.. <br />prinkder <br />'Fire Marm <br />EICI"1�, e j <br />lo zg-u <br />FEB 16 221 <br />CITY Of EVERETT <br />D RAW I N G LIST Permil Services <br />COVER SHEET <br />OVERALL SITE PLAN <br />ARCHITECTURAL SITE PLAN <br />CANOPY <br />STRUCTURAL NOTES &SPECIAL INSPECTIONS <br />SITE PLAN, CANOPY FOUNDATION & FRAMING PLANS <br />STRUCTURAL DETAILS <br />APPLICABLE CODES CITY OF VANCOUVER. WA <br />2015 INTERNATIONAL BUILDING CODE W/ WA AMENDMENTS <br />2015 INTERNATIONAL MECHANICAL CODE (IMC) <br />2015 UNIFORM PLUMBING CODE (UPC) <br />2015 INTERNATIONAL FIRE CODE (IFC) <br />2015 WASHINGTON STATE ELECTRICAL CODE (WSEC) <br />2015 ENERGY CONSERVATION CODE OF WASHINGTON <br />DEFERRED SUBMITTALS <br />• ELECTRICAL <br />• PLUMBING <br />01Y OF EVTT <br />REVIEWED FOR PERMIT <br />w <br />Lug <br />WW <br />a. o <br />z <br />wQ <br />W Q� <br />Z <br />rn W <br />W. DAVID HARDISTER <br />PERMIT SET <br />10.01.20 <br />Project #20-006 <br />L DESCRIPTION DATE <br />COVER SHEET <br />G000 <br />8 <br />Q <br />N L <br />Ty <br />E <br />CD <br />r <br />a.c_ <br />O <br />zo <br />0 <br />?L <br />N <br />rn 3 <br />a� <br />�a <br />2a <br />
The URL can be used to link to this page
Your browser does not support the video tag.