D <br />C <br />B <br />A <br />180'-0" <br />i <br />60'-O" <br />60'-0" <br />60'-0" <br />GENERAL NOTES <br />1 . EXISTING BUILDING CONSTRUCTION PROVIDES EXAMPLE OF FINISH LEVEL TO BE PROVIDED. Al <br />WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. <br />CONTRACTOR. <br />2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE <br />CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND <br />STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH <br />OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE <br />3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT <br />AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION <br />OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THROUGH <br />EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT <br />THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED <br />BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, <br />ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE <br />WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR <br />RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE <br />CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH <br />MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE <br />SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. <br />4. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS <br />STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK <br />AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. <br />5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP <br />IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. <br />6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS. ANY CHANGE TO SAME SHALL BE <br />SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL. <br />7. CONTRACTOR SUBMITOF ALL OF AND NUMBER THAT THEY <br />REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN PRIOR TO INSTALLATION FOR <br />ARCHITECT'S APPROVAL. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT DATA FOR <br />ARCHITECT'S APPROVAL ON ALL SPECIAL REQUIRINGO FABRICATION. <br />8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ARCHITECT OF <br />ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE DRAWINGS. <br />9. CONTRACTOR SHALL PROVIDE SOLID WOOD BLOCKING IN PARTITIONS FOR ALL WALL MOUNTED <br />FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. <br />10. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, <br />TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE <br />APPROVED BY THE ARCHITECT BEFORE USE. <br />11. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO <br />ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECT'S APPROVAL, <br />AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED TO MATCH EXISTING <br />MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD <br />OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER <br />PRIOR TO INSTALLATION. <br />EXITING NOTE) <br />SPRINKLED BUILDING 2015 I.B.C. <br />i <br />ALLOWABLE EXIT ACCESS TRAVEL DISTANCES; <br />B (SPRINKLED) = 300' <br />S-1 (ONE STORY, 24' CLEAR & SPRINKLED) = 400' <br />F-1 (ONE STORY, 24' CLEAR & SPRINKLED) = 400' <br />E.A.T.D.: = EXIT ACCESS TRAVEL DISTANCE <br />C.P.E.T.: = COMMON PATH EGRESS TRAVEL - MAX. 100 FT <br />D.D.: = DIAGONAL DISTANCE <br />S.D.: = SEPARATION DISTANCE (MINIMUM 1 /3 DIAGONAL) <br />OCCUPANCIES WITHIN TENANT SPACE: <br />3,519 S.F. "B" OCCUPANCY 1/100 = 35.19 OCCUPANTS. (1) EXIT REQUIRED - (2) PROVIDED <br />9,600 S.F. "S-1" OCCUPANCY 1 /500 = 19.2 OCCUPANTS. (1) EXITS REQUIRED - (4) PROVIDED <br />26,279 S.F. "F-1 " OCCUPANCY 1 /100 = 276 OCCUPANTS. (2) EXITS REQUIRED - (4) PROVIDED <br />OCCUPANCY NOTES <br />MAIN OCCUPANCY OF BUILDING F-1 (MANUFACTURING). NO SEPARATION REQUIRED BETWEEN F-1, S-1 <br />(STORAGE) AND B (OFFICE) PER I.B.C. TABLE 508.4 IN SPRINKLED BUILDING. <br />7'1 All <br />� " `,..� r f <br />IT <br />Ammellffilm". <br />B - OFFICE: 3,519 S.F. <br />F-1 - �MANUF.): 22,879 S.F. <br />S-1 - STORAGE): 12,000 S.F. <br />TOTAL 38,398 S.F. <br />PLUMBING FIXTURE COUNT BASED ON CURRENT USE. <br />WATER CLOSET CALCULATIONS <br />FOUNTAINSDRINKING REQUIRED: <br />PROVIDE <br />FOR EACH 500 <br />12. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED <br />DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. <br />13. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF <br />SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR <br />THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL <br />HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND <br />REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS <br />SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER <br />CONDITION TO RECEIVE THE FINISH INDICATED. <br />14. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING <br />ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS <br />OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. <br />FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY <br />PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, <br />SUBMIT FOUR (4) COPIES OF COMPLETE BACK-UP INFORMATION FOR PURPOSES OF EVALUATION. <br />WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. <br />15. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE <br />CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. <br />16. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE ARCHITECTURAL <br />DRAWINGS ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY <br />OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. <br />17. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S & TENANT APPROVAL SHOWING <br />LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS, FIRE AND SMOKE DETECTION DEVICES <br />INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC. <br />18. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR <br />STRUCTURAL COMPONENTS MUST BE APPROVED BY ARCHITECT & TENANT. <br />19. ALL WOOD IN CONTACT WITH FLOOR SLAB TO BE PRESERVATIVE TREATED WOOD PER I.B.C. SECTION <br />2304.12. <br />PLAN LEGEND <br />OCCUPANT LOAD FOR BUILDING 288 <br />2 DRINKING FOUNTAINS REQUIRED. <br />2 DRINKING FOUNTAINS PROVIDED. <br />USE <br />LOAD <br />AREA PER OCCUPANT <br />TOTAL <br />MIN. REQUIRED WC <br />PERCENTAGE <br />TABLE 1004.1.2 <br />OCCUPANTS <br />PLUMBING FIXTURES <br />REFER TO IBC COMMENTARY <br />(RATIO) <br />TABLE 2902.1 <br />SAMPLE PROBLEMS <br />B (BUSINESS) <br />3,519 S.F. <br />100 GROSS <br />35.19 17.59 MALE/17.59 FEMALE <br />1 PER 25 FOR <br />.7 MALE, .7 FEMALE <br />FIRST 50 <br />F-1 (MANUF.) <br />22,879 S.F. <br />100 GROSS <br />228.79 114.39 MALE/114.39 FEMALE <br />1 PER 100 <br />1.14 MALE, 1.14 FEMALE <br />S (STORAGE) <br />12,000 S.F. <br />500 GROSS <br />24 12 MALE/12 FEMALE <br />1 PER 100 <br />.12 MALE, .12 FEMALE <br />MALE - .7 + 1.14 + .12 = 1.96 or 2 REQUIRED <br />FEMALE - .7 + 1.14 + .12 = 1.96 or 2 REQUIRED <br />2 MALE AND 2 FEMALE WC REQUIRED <br />2 MALE WC & 1 URINAL AND 3 FEMALE WC PROVIDED <br />LAVATORY CALCULATIONS <br />USE <br />LOAD <br />AREA PER OCCUPANT <br />TOTAL <br />MIN. REQUIRED LAV. <br />PERCENTAGE <br />TABLE 1004.1.2 <br />OCCUPANTS <br />PLUMBING FIXTURES <br />REFER TO IBC COMMENTARY <br />(RATIO) <br />TABLE 2902.1 <br />SAMPLE PROBLEMS <br />B (BUSINESS) <br />3,519 S.F. <br />100 GROSS <br />35.19 17.59 MALE/17.59 FEMALE <br />1 PER 40 FOR <br />FIRST 80 <br />44 MALE, .44 FEMALE <br />F-1 (MANUF. <br />22,879 S.F. <br />100 GROSS <br />228.79 114.39 MALE/114.39 FEMALE <br />1 PER 100 <br />1.14 MALE, 1.14 FEMALE <br />S (STORAGE) <br />12,000 S.F. <br />500 GROSS <br />24 12 MALE/12 FEMALE <br />1 PER 100 <br />.12 MALE, .12 FEMALE <br />MALE - <br />.44 + <br />1.14 + <br />.12 = 1.70 OR 2 REQUIRED <br />FEMALE <br />- .44 <br />+ 1.14 <br />+ 12 = 1.70 OR 2 REQUIRED <br />3 MALE <br />AND 3 <br />FEMALE <br />LAVATORIES, PROVIDED <br />EXISTING WALL (SHADED) <br />NEW INTERIOR WALL PER PLAN <br />EARTH <br />GRAVEL/ROCK <br />CONCRETE <br />ASPHALT WAVING <br />WOOD FRAMING <br />BLOCKING OR SHIM <br />FINISH WOOD <br />GLASS(ELPJATION) <br />GLASS(SECTION) <br />GYPSUM WALL BOARD <br />CAULKING/SEALANT <br />PLYWOOD <br />RIGID INSULATION <br />BATT INSULATION <br />METAL <br />101 <br />A ELEVATION <br />D A1.2 B <br />SHEET <br />C <br />NUMBER <br />DETAIL <br />2 <br />A1.2 <br />SHEET <br />NUMBER <br />DOOR NUMBER (E=EXISTING) <br />INTERIOR <br />ELEVATION <br />la. <br />REVISIONS <br />WALL TYPES <br />2 I ENLARGED <br />A1.2 PLANS /DETAILS <br />COLUMNS OR <br />GRID LINES <br />TEMPERED GLASS <br />NOTE: PLUMBING CALCULATIONS FROM <br />APPROVED PERMIT # B2003-037. <br />USE OF SPACE REMAINS AS PREVIOUSLY <br />PERMITTED. NO CHANGES TO PLUMBING <br />SYSTEM UNDER THIS PERMIT. <br />