My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6200 23RD DR W 2020 Plans 2022-11-02
>
Address Records
>
23RD DR W
>
6200
>
Plans
>
6200 23RD DR W 2020 Plans 2022-11-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2022 9:47:22 AM
Creation date
12/15/2021 8:48:47 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
6200
Permit
B2010-026
Year
2020
Notes
Tenant improvement for TSI Seats. Reconfigure quality lab
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Two 12 gs. splay wires <br />at max. 8' (2,500mm) o.c. <br />0 <br />Max. 10' <br />(3000rnm) <br />Approx.45' 1 <br />Attachment options to structure (wood, concrete or steel) <br />a. Attachnient devices to structure �/4-inch (6mm) diaaneter x <br />3-inch (75mm) long closed -eye wood screws; minimum <br />penetration 1 inch (25mm) into the wood member. <br />b. No. 12 ga. splay wire looped around bottom chord of <br />open joint or truss. <br />c. Fetal -inch x 2-inch (50mm x 50mm) angle, attached to <br />concrete or steel. with approved fasteners. <br />d. Tie wire spire minimum 3/16-inch (5mrn) diameter x 2 <br />inches (50 mm) long, drilled and hammered. for concrete. <br />e, Tie wire wedge anchor V4 inch x 11 /� inches (6mm x <br />44mrn.), for concrete. <br />f. Beam/flange clamps for steel structure members. <br />Splay wire to be wrapped around itself three f ll turns; <br />within a 3-inch (75mrn) length. <br />Attachment options at partition <br />a. Attach partition track to suspended ceiling main runner <br />with two No. 8 S-screws. (Detail A. oraly.) <br />b. '/4-inch (6mm) closed. -eye bolt through partition track. <br />c. 2-inch. x 2-inch (50mm. x 50mm) metal angle with. two <br />No. 8 -screws in partition track. <br />® Splay wire to be wrapped around itself three full. terns. <br />within a 3-inch (75m ) length. <br />TOP OF WALL BRACING <br />Scale: N.T.S. <br />VI\ LI\1UL_U U1\LJ I LI\ I L011m_. f I p 1\ 1 Lill W. <br />Scale: N.T.S. <br />SOUND BATT <br />INSULATION OVER <br />ENTIRE SERVER ROOM <br />AREA CEILING <br />8" METAL CEILING <br />JOISTS AT 16" O.C. <br />5/8" TYPE 'Y' GWB <br />3-5/8" METAL <br />STUDS AT 16" O.C. <br />WITH 5/8" TYPE "X" <br />GWB EACH SIDE <br />0 <br />CD CD <br />SOUND BATT INSULATION <br />1 /8He DIA. X 1 " <br />POWDER ACTUATED <br />FASTENERS @ 24" <br />O.C. <br />BASE PER SCHEDULE <br />EXISTING CONC. FLOOR <br />I <br />ALL AT SERVER ROOM <br />ale: 1 f 2"-1,_o" <br />.0111 =1100'yi <br />■ <br />SUSPENDED CEILING <br />SYSTEM PER <br />REFLECTED CEILING <br />PLAN <br />3-5/89B METAL <br />STUDS AT 16" O.C. <br />WITH 5/8" TYPE "Xis <br />GWB EACH SIDE <br />SOUND BATT INSULATION <br />1 /8" DIA. X 1 " <br />POWDER ACTUATED <br />FASTENERS @ 24" <br />O.C. <br />BASE PER SCHEDULE <br />EXISTING CONC. FLOOR <br />WALL AT QUALITY LAB <br />Scale: 1 /2 1 0" <br />21 X 4' SUSPENDED ACOUSTICAL <br />TILE CEILING <br />® 2' X 4' LAY IN LED LIGHT FIXTURE. EATON—METALUX "CRUZE ST" <br />24CZ-30 OR APPROVED EQUAL. <br />0 SURFACE MOUNTED STRIP LED LIGHT FIXTURE. EATON—METALUX <br />2WSNLED OR APPROVED EQUAL. <br />EXIT LIGHTED EXIT SIGN WITH BATTERY BACK—UP <br />NOTE: PROVIDE EMERGENCY EXIT PATHWAY LIGHTING <br />TO COMPLY WITH B.B.C. SECTION 1008. <br />� ' I ki .., rl I■ C <br />Scale: N.T.S. <br />I <br />8" MAX <br />�IIIti �. ' t �a <br />Scale: N.T.S. <br />COUNC NNST TN®N R QUNR�I� <br />1) MINIMUM 2" WALL MOLDING OR APPROVED ALTERNATE. <br />2) GRID MUST BE ATTACHED TO TWO ADJACENT WALLS - OPPOSITE WALLS MUST <br />HAVE A 3/4" CLEARANCE, AND BE FREE TO SLIDE. <br />3) SPREADER BARDS SHALL BE USED TO PREVENT THE ENDS OF THE MAIN <br />BEAMS AT PERIMETER WALLS FROM SPREADING. ENDS OF MAIN BEAMS AND <br />CROSS TEES MAY BE TIED TOGETHER TO PREVENT THEIR SPREADING. <br />4) PERIMETER SUPPORT WIRES MUST BE WITHIN 8" OF CEILING EDGE. <br />5) PROVIDE MANUFACTURERS HEAVY GRID SYSTEM. <br />6) CEILING AREAS OVER 1,000 SF MUST HAVE HORIZONTAL RESTRAINT WIRE OR <br />RIGID BRACING. <br />7) CEILING AREAS OVER 2,500 SF MUST HAVE MUST HAVE SEISMIC SEPARATION <br />JOINTS OR FULL HEIGHT PARTITIONS. <br />8) CEILINGS WITHOUT RIGID BRACING MUST HAVE 2" OVERSIZED TRIM RINGS FOR <br />SPRINKLERS AND OTHER PENETRATIONS. <br />9) CHANGES IN CEILING PLANE MUST HAVE POSITIVE BRACING. <br />10) CABLE TRAYS AND ELECTRICAL CONDUITS MUST BE INDEPENDENTLY <br />SUPPORTED AND BRACED. <br />11) SUSPENDED CEILING WILL BE SUBJECT TO SPECIAL INSPECTION AS REQUIRED <br />BY LOCAL BUILDING OFFICIAL. <br />4! <br />45' or less <br />CROSS TEE <br />PER ASTM <br />C635� <br />Scale: N.T.S. <br />STEEL STUD <br />COMPRESSION POST <br />ONLY IF REQUIRED BY <br />BUILDING OFFICIAL <br />�6 <br />6 <br />8" MAX <br />Scale: N.T.S. <br />M <br />#12 HANGER WIRE <br />ANCHORED TO <br />STRUCTURE ABOVE <br />,�EFERRBU SURI�N�"f <br />IF CEILING SYSTEM TO BE INSTALLED IS NOT AS SPECIFIED ABOVE CONTRACTOR <br />SHALL SUBMIT ALTERNATIVE MATERIAL AND METHODS AS DESCRIBED IN I.B.C. <br />SECTION 104.11 TO LOCAL BUILDING OFFICIAL. ENGINEERING PLANS SHALL BE <br />STAMPED AND SIGNED BY AN ENGINEER REGISTERED IN THE STATE OF <br />WASHINGTON. NO WORK ON THESE ITEMS SHALL BEGIN UNTIL BUILDING OFFICIAL <br />APPROVAL HAS BEEN RECEIVED. <br />LAUB&= IMM9 <br />SUSPENDED CEILINGS SHALL BE BRACED AGAINST LATERAL MOVEMENT DUE TO <br />EARTHQUAKE PER IBC SECTION 808, ASTM C635 AND C636. IN THE ABSENCE <br />OF AN ENGINEERED DESIGN THE FOLLOWING BRACING SYSTEM WILL BE <br />REQUIRED. <br />MAINT-TEE CLASSIFICATION SHALL BE 'HEAVY-DUTY' <br />FOUR NO. 12 GA STEEL WIRES SHALL BE ATTACHED TO A MAIN RUNNER WITHIN <br />2 INCHES OF A CROSS RUNNER. THE WIRES SHALL BE SPLAYED 90 DEGREES <br />TO EACH OTHER AND RUN UP TO BE ATTACHED TO STRUCTURE ABOVE AT AN <br />ANGLE NOT TO EXCEED 45 DEGREES FROM THE HORIZONTAL. <br />A COMPRESSION STRUT SHALL EXTEND FROM THE MAIN RUNNER AT THE <br />ATTACHMENT OF THE WIRES VERTICALLY AND BE ATTACHED TO THE STRUCTURE <br />ABOVE ONLY IF REQUIRED BY BUILDING OFFICE. SUCH BRACING SYSTEMS <br />SHALL BE PROVIDED AT A SPACING NOT TO EXCEED 12 FEET IN BOTH <br />DIRECTIONS. <br />VERTICAL PERIMETER HANGER WIRES INSTALLED NOT MORE THAN 8" FROM WALL, <br />PER ASTM C636 AND MANUFACTURERS REQUIREMENTS. <br />LIGHTING FIXTURES WHICH WEIGH LESS THAN 56 POUNDS SHALL BE ATTACHED <br />TO THE CEILING GRID SYSTEM AND TO BUILDING STRUCTURE BY AT LEAST 2 NO. <br />12 GAGE WIRES. LIGHT FIXTURES WHICH WEIGH 56 POUNDS OR MORE SHALL <br />BE SUSPENDED FROM THE STRUCTURE INDEPENDENT OF THE CEILING GRID, AND <br />AN ENGINEERING DESIGN SHALL BE SUBMITTED TO SUBSTANTIATE THE <br />SUSPENSION SYSTEM. <br />MECHANICAL EQUIPMENT SHALL BE SUPPORTED INDEPENDENT OF THE CEILING <br />SUSPENSION SYSTEM. <br />45` or less <br />#12 HANGER WIRE <br />TIGHT LOOP THROUGH HANGER <br />HOLE & THREE TIGHT TURNS <br />WITHIN 3" ( TOP TO BOTTOM) <br />:r <br />0 <br />45° or less <br />MAIN CEILING <br />BEAM PER ASTM C635 <br />
The URL can be used to link to this page
Your browser does not support the video tag.