1. EXISTING BUILDING CONSTRUCTION PROVIDES EXAMPLE OF FINISH LEVEL TO DE 11. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE
<br />PROVIDED. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO
<br />ARCHITECT'S APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL
<br />2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN,
<br />CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND
<br />COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION.
<br />TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND
<br />COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. 12. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR
<br />REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED
<br />3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, OTHERWISE.
<br />EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING
<br />NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE 13. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE
<br />CONTRACTOR REPRESENTS THAT THROUGH EXAMINATION OF THE SITE AND ALL EXISTING OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL
<br />CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE
<br />BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH
<br />THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT
<br />SATISFACTORY FOR CONSTRUCTION OF THE WORK. INHERE MINOR ADJUSTMENTS TO THE REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND
<br />WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH
<br />OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT INDICATED.
<br />DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO
<br />THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN 14. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY
<br />OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND ,APPROVAL. LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH
<br />REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY
<br />4. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR
<br />MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED
<br />WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT FOUR (4) COPIES OF
<br />5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF COMPLETE BACK—UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING
<br />WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED.
<br />6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS. ANY CHANGE TO SAME 15. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH
<br />SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL. LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS.
<br />T. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER 16. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE
<br />THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN PRIOR ARCHITECTURAL DRAWINGS ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND
<br />TO INSTALLATION FOR ARCHITECT'S APPROVAL. CONTRACTOR SHALL PROVIDE SHOP ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS.
<br />DRAWINGS AND PRODUCT DATA FOR ARCHITECT'S APPROVAL ON ALL SPECIAL ITEMS 17. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S & TENANT APPROVAL SHOWING
<br />REQUIRING CUSTOM FABRICATION. LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS, FIRE AND SMOKE
<br />DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC.
<br />8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY
<br />ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE DRAWINGS. 18. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR
<br />STRUCTURAL COMPONENTS MUST BE APPROVED BY ARCHITECT & TENANT.
<br />0. CONTRACTOR SHALL PROVIDE SOLID WOOD BLOCKING IN PARTITIONS FOR ALL WALL
<br />MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 10. ALL WOOD IN CONTACT WITH FLOOR SLAB TO BE PRESERVATIVE TREATED WOOD PER
<br />I.B.C. SECTION 2304.12.
<br />10. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE,
<br />COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS
<br />PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE.
<br />7 -
<br />0 _D
<br />Scala. 1 /8"= 9_0"
<br />N
<br />TOILET
<br />115
<br />E313 i
<br />N
<br />m
<br />.. Q MEN
<br />a
<br />OPEN
<br />OFFICE
<br />1 44
<br />10'-2 1/2'
<br />■
<br />OFFICE ®_
<br />220
<br />20
<br />TA3.0
<br />m
<br />NEW WALL
<br />B
<br />10®-2 1 /2_"
<br />!T:::�
<br />OFFICE
<br />122
<br />NOTE: ALL WORK SHOWN EXISTING
<br />EXCEPT NEW WALLS INDICATED. WHERE
<br />DEMOLISHED WALL INTERSECTS WALLS
<br />TO REMAIN, PATCH GWB TO MATCH
<br />ADJACENT SURFACE WHERE DAMAGED
<br />AND PAINT.
<br />...................................................................................................................................
<br />a ..............................................
<br />14'-6 1 /2'
<br />OFFICE
<br />123
<br />NMI
<br />J . ;;
<br />20 SIM.
<br />TA3.0 11
<br />D Ln
<br />EXISTING FALL (SHADED) a DOOR NUMBER (E=EXISTING)
<br />NEW INTERIOR WALL PER PLAN ELEVATION
<br />A
<br />�7� D A1.2 B INTERIOR
<br />EARTH SHEET ELEVATION
<br />NUMBER
<br />° GRAVEL/ROCK 2 DETAIL DETAILS
<br />A1.2 SHEET
<br />® CONCRETE NUMBER
<br />ASPHALT PAVING 2 REVISIONS
<br />WOOD FRAMING 1 WALL TYPES (SHEET TA2.0)
<br />BLOCKING OR SHIM 2 9 9 ENLARGED
<br />A1.2 I I FINISH 'MOOD PLANS /DETAILS
<br />l
<br />GLASS(ELEVATION)
<br />COLUMNS OR
<br />GLASS(SECTION) GRID LINES
<br />GYPSUM WALL BOARD
<br />CAULKING/SEALANT (OR) T TEMPERED GLASS
<br />�_-- PLYWOOD
<br />RIGID INSULATION
<br />EE BATT INSULATION
<br />®I METAL
<br />REVIEWED FOR EPEWT
<br />O
<br />
|