My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2424 60TH ST SE 2020 Plans 2022-11-08
>
Address Records
>
60TH ST SE
>
2424
>
Plans
>
2424 60TH ST SE 2020 Plans 2022-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 11:07:35 AM
Creation date
12/15/2021 9:05:26 AM
Metadata
Fields
Template:
Address Document
Street Name
60TH ST SE
Street Number
2424
Permit
CW2002-002
Year
2020
Notes
Convert illegal duplex back to SFR and interior remodel
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROJECT INFORMATION: <br />OWNER: JEFF LAURENCE <br />ADDRESS: 2424 60TH ST. SE, EVERETT, WA 98203 <br />PROJECT SCOPE: <br />INTERIOR REMODEL OF EXISTING RESIDENCE; <br />CONVERT ILLEGAL DUPLEX BACK TO SINGLE FAMILY <br />RESIDENCE. <br />PARCEL: 28050500201500 <br />LEGAL DESCRIPTION: <br />SEC 05 TWP 28 RGE 05RT-18D-1) E 80FT MEAS R/A & <br />PLT ELY LN FDT BEG AT INT OF E & W C/L SEC & E LN <br />BRDY CUT-OFF TPB TH NLY ALG SD E LN 1 OOFT TO S <br />LN CO RD TH N84*32 30E ALG SD RD 195.62FT TH S05* <br />27 30E 129.44FT TOE & W C/L TH WLY ALG SD C/L <br />201-37FT TO TPB <br />ZONE: R-1 <br />CODE: <br />BASED ON THE 2015 I.R.C., 2015 UPC, 2015 WA <br />STATE ENERGY CODE, AND 2015 WA STATE <br />AMENDMENTS <br />OCCUPANCY GROUP <br />R-3 <br />CONSTRUCTION TYPE <br />VB <br />ALLOWABLE FLOOR AREA <br />UNLIMITED <br />FLOOR AREA (SF) <br />EXISTING LOWER LEVEL <br />EXISTING MAIN LEVEL <br />TOTAL LIVING AREA: <br />EXIST. NEW N/A <br />1,240 SF <br />.1,291 SF <br />2,531 SF <br />REQUIRED SEPARATION <br />N/A <br /># OF STORIES <br />I <br />FULLY SPRINKLERED <br />NO <br />SHEET INDEX: <br />A01.1 <br />TITLE SHEET <br />A2.0 <br />DEMO PLAN <br />A2.1 <br />FLOOR PLANS <br />A3,1 <br />ELEVATIONS <br />A4.1 <br />SECTIONS <br />A9.1 <br />DETAILS <br />SITE PLAN NOTES <br />1 THERE IS AN AVAILABLE PUBLIC WATER SYSTEM. <br />2. THIS IS NOT A LEGAL SURVEY. PROPERTY DESCRIPTION <br />INFORMATION ON THIS SHEET FOR GENERAL USE ONLY. <br />3. CONNECT UTILITY EXTENSIONS TO EXISTING UTILITIES. <br />CONTRACTOR TO VERIFY LOCATIONS OF EXTENSIONS. <br />4. LIMITS OF CONSTRUCTION, STORAGE AREA, & VEGETATION OF <br />CONCERN TO BE COORDINATED W/OWNER <br />5. NO PROPOSED CHANGES TO BUILDING COVERAGE <br />6. NO PROPOSED CHANGES TO IMPERVIOUS AREA <br />HEIGHT CALCULATIONS: <br />BENCH MARK: MH RM ELEV. - 286,62' <br />EXISTING RESIDENCE: <br />A= 299.53' <br />B= 297.6' <br />C= 293.71' <br />D= 294.5' <br />1185.34'/ 4 = 296.33'(AVG, BASE ELEV.) <br />+28'ALLOWED <br />324.33 = MAX. HT. <br />NO PROPOSED CHANGES <br />LOT COVERAGE BY BUILDINGS - LOT SIZE = 8,712 SF (0.20 ac.) <br />EXISTING RESIDENCE <br />1,787 SF <br />EXISTING OUT BUILDING <br />400 5F <br />TOTAL: <br />2,187 SF <br />BLDG. SF/LOT SIZE = 2,187 / 8,712 = 25% <br />NO PROPOSED CHANGES <br />IMPERVIOUS AREA: <br />EXIST. RES. (ROOF AREA) <br />2,096 SF <br />EXIST. OUTBUILDING (ROOF AREA) <br />543 SF <br />EXIST. WALKWAYS <br />312 SF <br />EXIST. DECK/PORCH <br />328 SF <br />EXIST. PAVED DRIVEWAYS <br />552 SF <br />EXIST. GRAVEL DRIVE <br />675 SF <br />TOTAL: <br />4,506 SF <br />NO PROPOSED CHANGES <br />GR <br />ADING AND DRAINAGE <br />10 Provislons shall be made for the control and drainage of surface <br />water around buildings by: gutters, drain lines, inlets ard catch <br />basins or other necessary drainage structures and shall be installed <br />where storm water disposal cannot be obtained without their use or <br />where erosion cannot be prevented by finish grading and planting. <br />Dry wells shall not br i.,,stalled in areas where the soil is not well <br />drained and,jor porous. <br />2. Grading shall be provided to insure: <br />(a) Diversion of water away from buildings. <br />(b) Prevention of standing water and soil saturation detrimental <br />to structures and lot use. <br />(c) That natural drainage channels or basins are not blocked or <br />filled. <br />(d) Provisions for the disposal of water from a lota <br />ig) Protection of A'0joinjng property. <br />IF BUILDING IS NOT POSITIONED 'At <br />INDICATED ON APPROVED SITE PLAN, <br />A NEW SITE PLAN SHALL BE SUBMIT- <br />TED. NO FURTHER INSPECTIONS WILL <br />BE MADE ON THIS PROJECT UNTIL THE <br />REVISED SITE PLAN HAS BEEN APPROV- <br />ED BY THE BUILDING/PUBLIC WORKS <br />DEPTS. <br />it it oviers ruspvft�,�IAY 10 establish and stake _a# <br />property lines. <br />PROPANE TANKS, HEAT PUMPS AND <br />OTHER EQUIPMENT OR APPURTENANCES <br />MAY NOT BE LOCATED IN THE FRONT <br />AND SIDE SETBACKS. PROPANE TANKS <br />REQUIRE ADDITIONAL PERMITS ISSUED <br />BY THE EVERETT FIRE DEPARTMENT <br />PRIOR TO iNSTALLATION. <br />Additional Permits Are Required <br />For This Project To Include: <br />E] Plumbing E] Sprinkler <br />0 Mechanical []Fire Alarm <br />ER Electrical <br />60TH ST. SE <br />MH RIM <br />ELEV. = <br />286.62' <br />Permit#: <br />CW2002-W2 <br />Site Address: <br />2424 60TH ST SE <br />Owner: <br />LAURENCEIEFFERY <br />Tenant: <br />[TenNamel <br />App. Date: <br />2/21/2020 <br />Proposed Use: <br />DUPLEX TOSFR <br />Description: <br />CONVERT ILLEGAL DUPLEX BACK TO SFR <br />AND INTERIOR REMODEL <br />Reviewed By: <br />Date: <br />Office Set <br />Job Site Set _Fire/PlanningSet <br />@ 03, U_ <br />JUL 14 2 <br />CITY OF EVE <br />Permit Servi <br />VICINITY MAP, <br />APPROVED <br />PLANNING & COMMUNITY <br />DEVELOPMENT DEPT. <br />BY <br />DATE- <br />CITY OF EVERETT cc <br />W <br />REVIEWED FOR PERMIT 0. <br />UJ <br />< I— <br />C5 Z <br />LU <br />UJ <br />UJ <br />01= <br />Cr <br />0 <br />LU 0 <br />U_ <br />00 <br />C' <br />Z <br />00 cc <br />W <br />UJ <br />Cn <br />CC <br />W U_ <br />00 <br />Z z <br />CC 0 <br />0 <br />cr_ <br />n <br />UJ <br />M Cr <br />Cr <br />UJ 0 <br />LLJ <br />C/) <br />do U, <br />N <br />(1)0 <br />< r <br />0 < <br />z :D <br />U z <br />UJ <br />Orn <br />cc <br />LL <br />0 <br />Cl) <br />O� <br />0 <br />0 C) <br />0 W <br />F_ 0 <br />cc <br />0 a- <br />UJ <br />= <br />5 F- <br />M <br />D 0 <br />Or <br />0 <br />CC M <br />< <br />0 0 <br />Z C/) <br />C) 0OC <br />LU <br />0 M = < <br />>_ D <br />P- <br />00a- <br />() UJ <br />Llj!= <br />U) < <br />0 <br />Z <br />z <br />00 <br />UJ z <br />U) <br />Lu <br />X: z <br />Li <br />U) <br />z <br />0 <br />CO <br />LIJ <br />C= <br />W <br />co <br />O <br />VJ <br />00 <br />0) <br />< <br />LL1 <br />W <br />LL1 <br />LIJ <br />C) <br />LLj <br />z <br />U) <br />W <br />F� <br />U) <br />0 <br />C\1 <br />z Lu <br />LLI <br />< r) r <br />cc U) <br />0 <br />NN <br />0) <br />M <br />C:) <br />0) <br />0 <br />Z <br />04 <br />0 <br />T <br />LU <br />CY) <br />< <br />z?5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.