CONSTRUCTION NOTES <br />1. GENERAL <br />A. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH THE PRINCIPLES OF GOOD <br />CONSTRUCTION PRACTICE. <br />B. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR THE SAFETY (INCLUDING FIRE SAFETY) OF THE NEW, AS WELL AS EXISTING, <br />STRUCTURES. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, BRACING, <br />AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL SAFETY <br />ORDINANCES. ANY DEVIATION FROM SUCH ORDINANCES MUST BE APPROVED PRIOR <br />TO ERECTION. THAT RESPONSIBILITY SHALL APPLY CONTINUOUSLY AND SHALL NOT <br />BE LIMITED TO NORMAL WORKING HOURS. <br />C. THE CONTRACTOR SHALL CHECK ALL INFORMATION ON THE PLANS (INCLUDING <br />DIMENSIONS) PRIOR TO COMMENCING THE WORK. ALL DISCREPANCIES SHALL BE <br />CALLED TO THE ATTENTION OF THE ENGINEER, AND SHALL BE RESOLVED BEFORE <br />PROCEEDING WITH THE WORK. <br />D. ALL CONSTRUCTION WORK (INCLUDING, BUT NOT LIMITED TO, MEANS, METHODS, <br />SEQUENCES, TECHNIQUES, PROCEDURES, ETC.) IS THE SOLE RESPONSIBILITY OF <br />THE CONTRACTOR. <br />THE RECOMMENDATIONS (IF ANY) ON THESE PLANS REGARDING THE MEANS, <br />METHODS, SEQUENCES, TECHNIQUES, PROCEDURES, ETC. OF CONSTRUCTION <br />SHALL BE CONSIDERED AS MINIMAL REQUIREMENTS. THE CONTRACTOR SHALL NOT <br />DEVIATE FROM THESE RECOMMENDATIONS UNLESS SUCH DEVIATION IS TOWARD <br />MORE STRINGENT REQUIREMENTS. <br />E. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RESTORATION OF WORKING <br />CONDITION OF ALL EXISTING COMPONENTS AND STRUCTURES AFFECTED BY THIS <br />CONSTRUCTION. THE CONTRACTOR SHALL CONSTANTLY KEEP THE AREA OF <br />CONSTRUCTION FROM ACCUMULATION OF WASTE MATERIALS AND DEBRIS. AT THE <br />END OF WORK, THE CONTRACTOR SHALL REMOVE ALL WASTE, SURPLUS MATERIAL, <br />TOOLS, AND EQUIPMENT. <br />F. THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE ENGINEER <br />HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONJUNCTION WITH <br />THIS PROJECT EXCEPT FOR LIABILITY RISING FROM THE SOLE NEGLIGENCE OF THE <br />ENGINEER. ANY LIABILITY BY SGE AS RELATED TO THIS PROJECT IS LIMITED TO THE <br />ENGINEERING FEES RECEIVED FOR THE SERVICES RENDERED. <br />G. ALL MATERIALS, STRUCTURES, AND WORKMANSHIP SHALL CONFORM TO THESE <br />PLANS, CALCULATIONS, AS WELL AS TO THE ESTABLISHED GUIDELINES SET FORTH <br />BY THE LATEST ADOPTED EDITIONS OF 2018 WASHINGTON STATE BUILDING CODE, <br />AISC MANUAL OF STEEL CONSTRUCTION, ACI 318, AND ALL OTHER APPLICABLE <br />REGULATORY DOCUMENTS. IN CASE OF ANY CODE CONFLICTS, THE CONTRACTOR <br />SHALL CONTACT SGE <br />H. THESE PLANS AND CALCULATIONS ARE BASED UPON THE ASSIGNMENT FROM, AS <br />WELL AS ON THE INFORMATION ABOUT, THE NEW EQUIPMENT, AS PROVIDED BY <br />CASCADE COFFEE [MR. DENNIS STICKLES, TEL. (425) 347-3995]. <br />I. THIS DESIGN SHALL BE USED EXCLUSIVELY BY CASCADE COFFEE, AS WELL AS <br />THEIR CONTRACTOR(S). ANY OTHER USE (INCLUDING, BUT NOT LIMITED TO, REVIEW, <br />DISSEMINATION, OR COPYING) OF THESE DESIGN MATERIALS AND ANY PORTION <br />THEREOF, AS WELL AS AN USE OF THOSE MATERIALS BY ANY PARTY OR PARTIES <br />OTHER THAN THE ONES SPECIFIED ABOVE, ARE STRICTLY PROHIBITED UNLESS <br />UNDER A WRITTEN PERMISSION BY SGE. <br />J. DO NOT SCALE THE PLANS. <br />K. REFER TO SPECIAL INSPECTION SCHEDULE FOR ALL SPECIAL INSPECTION C <br />REQUIREMENTS. <br />L. THESE PLANS SUPERSEDE ANY OTHER PLANS PREVIOUSLY ISSUED BY SGE FOR <br />THE SUBJECT PROJECT. <br />M. THE MEASUREMENTS SHOWN ON THE PLANS ARE BASED UPON THE CATALOGUED <br />(IDEAL) DIMENSIONS OF THE EQUIPMENT THE CONTRACTOR SHALL VERIFY THE <br />DIMENSIONS AGAINST THOSE OF THE TEMPLATE AND/OR OF THE ACTUAL <br />EQUIPMENT PRIOR TO ANY CONSTRUCTION ACTIVITIES. <br />2. DESIGN CONSIDERATIONS <br />A. THESE STRUCTURAL PLANS AND CALCULATIONS WERE DEVELOPED BY SGE <br />RESTRICTIVELY IN REGARD TO THE INSTALLATION OF A 9,000-GALLON LIN TANK & <br />VAPORIZER AT CASCADE COFFEE, 1525 75TH ST SW #100, EVERETT, WA 98203. <br />B. THIS DESIGN DOES NOT CONSIDER THE STRUCTURAL ADEQUACY OF THE <br />EQUIPMENT (LEGS, BASEPLATES, AND CONNECTIONS BETWEEN THESE MEMBERS <br />BY OTHERS). FOR THE PURPOSES OF THIS DESIGN, ALL NEW EQUIPMENT WAS <br />ASSUMED TO BE STRUCTURALLY ADEQUATE. <br />3. LOADS <br />THESE STRUCTURAL PLANS AND CALCULATIONS WERE BASED UPON THE <br />FOLLOWING MINIMAL LOADS COMPLIANT WITH CHAPTER 16 OF THE 2018 <br />WASHINGTON STATE BUILDING CODE AND ASCE 7 (REFER TO SEISMIC PARAMETER A <br />SCHEDULE). <br />A. PROJECT INFORMATION: <br />SITE LATITUDE, LONGITUDE 47.9336865,-122.256386 <br />RISK CATEGORY II <br />B. WIND DESIGN DATA: <br />BASIC WIND SPEED, MPH 110 <br />WIND EXPOSURE C <br />C. EARTHQUAKE DESIGN DATA: <br />SITE CLASS D <br />SEISMIC DESIGN CATEGORY D <br />SPECTRAL RESPONSE ACCELERATION PARAMETERS: <br />SS 1.370 <br />S1 0.486 <br />SIDS 1.096 <br />SD1 0,722 <br />ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCE <br />4. SOILS <br />A. THE DESIGN WAS BASED UPON THE REQUIREMENTS OF 2018 WASHINGTON STATE <br />BUILDING CODE SECTION 1806 AND TABLE 1806.2. <br />B. THE SOIL PRESSURE UNDER THE NEW EQUIPMENT PAD IS NOT EXPECTED TO <br />EXCEED 1,000 PSF UNDER THE DEAD AND LIVE LOADS, AND 1,900 PSF UNDER DEAD, <br />LIVE, AND SHORT-TERM LOADING. <br />C. CONTRACTOR SHALL IMMEDIATELY INFORM SGE IF SOILS OF DIFFERENT NATURE <br />OR PROPERTIES (GROUND WATER, APPARENTLY LOWER CAPACITY SOILS, OR <br />AGGRESSIVE SOILS) WERE ENCOUNTERED DURING THE CONSTRUCTION. <br />D. THE CONTRACTOR SHALL LOCATE, REMOVE, OR PROTECT ALL UNDERGROUND <br />PIPING, CONDUITS, VAULTS, ETC. AS REQUIRED BY THE APPLICABLE CODE AND <br />JURISDICTION, <br />E. THE NEW PADS SHALL NOT BE PLACED AT THE FOLLOWING LOCATIONS: <br />a. OVER ANY EXISTING STRUCTURE, AND/OR CAST AGAINST SUCH STRUCTURES; <br />b. CLOSER THAN 6" (CLEAR) TO, ANY EXISTING FOOTINGS; <br />c. CLOSER THAN 24" TO ANY EXISTING WALL; <br />d. AT/ABOVE EXISTING RETAINING WALLS UNLESS FURTHER AWAY (CLEAR) THAN <br />THE DEPTH OF THE WALL. <br />ANY OF THE ABOVE CONDITIONS SHALL BE BROUGHT TO THE IMMEDIATE <br />ATTENTION OF SGE PRIOR TO THE BEGINNING OF CONSTRUCTION OR UPON <br />DISCOVERY. NO WORK SHALL BE CONDUCTED ON THE PADS AT SUCH LOCATIONS <br />UNTIL WRITTEN AUTHORIZATION BY SGE <br />F. AS A MINIMUM, THE SOIL IMPROVEMENTS SHALL INCLUDE THE FOLLOWING. <br />THE NEW PADS SHALL BE UNDERLAIN BY A 18" MIN. LAYER OF STRUCTURAL FILL <br />CONSISTING OF CLEAN CRUSHED STONE, GRAVEL, OR CLASS If BASE COMPACTED <br />TO A FIRM AND UNYIELDING CONSISTENCY WITH A MINIMUM OF 4 PASSES OF A <br />VIBRATORY PLATE COMPACTOR OR DRUM ROLLER WITH A MINIMUM STATIC WEIGHT <br />OF 500 POUNDS. THE STRUCTURAL FILL SHALL BE PLACED OVER A GEOTEXTILE <br />FABRIC SUCH AS MIRAFI 600X, OR AN EQUIVALENT. <br />ALTERNATIVELY, CONTROLLED LOW STRENGTH MATERIAL (CLSM) WITH A MAXIMUM <br />COMPRESSIVE STRENGTH OF 50 PSI MAY BE USED PER NATIONAL READY MIXED <br />CONCRETE ASSOCIATION GUIDE SPECIFICATION AND ALL APPLICABLE ASTM <br />STANDARDS. <br />G. ALL EARTHWORK IS RECOMMENDED TO BE CONDUCTED UNDER THE GUIDANCE OF <br />A REGISTERED GEOTECHNICAL OR CIVIL ENGINEER. <br />H. A GEOTECHNICAL ENGINEER FAMILIAR WITH THE SITE IS RECOMMENDED TO <br />REVIEW THESE PLANS, AS WELL AS THE EXCAVATION AND IMPROVEMENTS OF SOIL. <br />THE PLACEMENT OF REBARS AND CONCRETE IS RECOMMENDED NOT TO <br />COMMENCE WITHOUT A WRITTEN AUTHORIZATION (MEMO) FROM THE <br />GEOTECHNICAL ENGINEER STATING THE ADEQUACY OF THE DESIGN ASSUMPTIONS <br />AND THE ACTUAL EXCAVATION. THE FOUNDATION TYPE AND/OR SIZE MAY CHANGE <br />AS A RESULT OF THE REVIEW BY A GEOTECHNICAL ENGINEER, OR OF THE <br />DISCOVERY OF SOILS THAT DIFFER FROM THE ORIGINAL DESIGN ASSUMPTIONS. <br />5. CONCRETE <br />A. ALL NEW REINFORCED CONCRETE SHALL BE OF NORMAL WEIGHT (145 PCF): <br />a. MINIMUM COMPRESSIVE STRENGTH OF IN 28 DAYS 4,500 PSI ASTM C39; <br />b. PORTLAND CEMENT TYPE IIA ASTM C150; <br />c. MAXIMUM AGGREGATE SIZE 1 ASTM C33; <br />d. MAXIMUM WATER -CEMENT RATIO 0.45 <br />B. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF SEVEN <br />(7) DAYS AFTER PLACEMENT. ALTERNATE METHODS WILL BE APPROVED IF <br />SATISFACTORY PERFORMANCE CAN BE ASSURED. <br />C. THE SURFACE OF ALL NEW CONCRETE SHALL BE FLAT (1/8" MAX. UNFLATNESS <br />UNDER 10-FT STRAIGHTEDGE), AND SHALL HAVE ROUGH BROOM FINISH. FORM 3/4" <br />CHAMFERS AT ALL EXPOSED EDGES OF CONCRETE. UNLESS NOTED OTHERWISE, <br />THE SURFACE OF CONCRETE SHALL SLOPE AT 0.75% MAX. FOR DRAINAGE. <br />D. CONTRACTOR SHALL ASSURE FULL AND UNIFORM CONTACT BETWEEN CONCRETE <br />SURFACE AND EQUIPMENT BASEPLATES. IF NECESSARY, USE NON -SHRINK <br />GROUTING UNDER BASEPLATES (SIKAGROUT 212 OR APPROVED EQUAL). <br />E. NEW CONCRETE MAY BE PROTECTED WITH SIKATOP SEAL 107 OR APPROVED EQUAL <br />(BREATHABLE, EXTERIOR) SEALER. <br />F. UNLESS SPECIFICALLY AUTHORIZED BY SGE, INSTALLATION OF EQUIPMENT MAY <br />BEGIN NOT EARLIER THAN 7 DAYS AFTER POURING OF CONCRETE. <br />6. REINFORCING STEEL <br />A. UNLESS NOTED OTHERWISE, ALL REINFORCING STEEL SHALL CONFORM TO ASTM <br />SPECIFICATION A615 GRADE 60. ALL REBARS CONNECTED BY, OR SUBJECTED TO, <br />WELDING SHALL BE OF ASTM SPECIFICATION A706. <br />B. ALL REINFORCING STEEL SHALL BE SPLICED WITH CLASS B SPLICES. SPLICE <br />LENGTHS SHALL BE AS FOLLOWS: <br />MINIMUM SPLICE LENGTH <br />NWC <br />fc=4,500 PSI <br />TOP REBAR <br />BOTTOM REBAR <br />PAD THICKNESS <br />>12" <br />512" <br />ANY <br />#4 <br />19" <br />15" <br />15" <br />N <br />#5 <br />24" <br />18" <br />18" <br />X <br />#6 <br />28" <br />22" <br />22" <br />m <br />#7 <br />41" <br />32" <br />32" <br />w <br />w <br />#8 <br />46" <br />35" <br />35" <br />#9 <br />58" <br />45" <br />45" <br />C. STANDARD HOOKS SHALL BE CONSTRUCTED AS FOLLOWS: <br />STANDARD HOOKS <br />TYP <br />RADIUS (R, IN.) <br />EXTENSION (EXT, IN.) <br />DIAGRAM <br />BEND <br />90° 180° <br />90° <br />180, <br />90° <br />180, <br />#3 <br />1 2 <br />6 <br />4 <br />EXT <br />#4 <br />_ <br />8 <br />42 <br />N <br />U) <br />X <br />#5 <br />-�2 - <br />2 2 <br />10 <br />5 <br />#6 <br />3 <br />12 <br />6w <br />m <br />#7 <br />3 2 <br />14 <br />7 <br />w <br />#8 <br />4 <br />16 <br />8 <br />D. REBARS SHALL BE HELD IN THE REQUIRED POSITION BY MEANS OF APPROVED <br />DEVICES. <br />E. REBAR SPACING SHOWN IS MAXIMUM DISTANCE BETWEEN REBAR CENTER LINES. <br />F. REBARS SHALL BE CLEAN OF DIRT, OIL, SCALE, AND FOREIGN MATERIALS. <br />7. POST -INSTALLED ANCHORS <br />A. ALL ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. <br />B. ALL VAPORIZER ANCHORAGE HARDWARE (THREADED, RODS, NUTS, AND WASHERS) <br />SHALL BE GALVANIZED. <br />C. THE ANCHORAGE HARDWARE SHALL STRICTLY MEET THE NOTED ASTM <br />SPECIFICATIONS, PARTICULARLY: THREADED RODS - F1554 GRADE AS SHOWN; NUTS <br />- ASTM A194 GRADE 2H OR ASTM A563 GRADE DH; PLATE WASHERS - A36; CIRCULAR <br />WASHERS - F436. <br />D. STEELS OF HIGHER GRADES OR DIFFERENT ASTM SPECIFICATIONS SHALL NOT BE <br />USED WITHOUT A REVIEW AND WRITTEN APPROVAL BY SGE. <br />E. THE SET ANCHOR ROD SHOULD NOT BE DISTURBED OR LOADED DURING THE <br />SPECIFIED CURING TIME. <br />F. UNLESS SPECIFICALLY AUTHORIZED BY SGE, INSTALLATION OF THE ANCHORS AND <br />EQUIPMENT MAY BEGIN NOT EARLIER THAN 7 DAYS AFTER POURING OF CONCRETE. <br />G. USE EQUIPMENT BASEPLATES AS A TEMPLATE FOR THE INSTALLATION OF THE <br />ANCHORS. REFER TO PLANS BY OTHERS FOR THE ORIENTATION OF THE EQUIPMENT <br />ON THE PADS. <br />H. USE HAMMER DRILL AND CARBIDE BITS TO DRILL ANCHOR HOLES. <br />8. STRUCTURAL STEEL <br />A. STRUCTURAL STEEL (NEW EMBEDDED PLATES) SHALL BE DETAILED, FABRICATED <br />AND ERECTED IN ACCORDANCE WITH THE AISC SPECIFICATION FOR THE DESIGN, <br />FABRICATION AND ERECTION OF STRUCTURAL STEEL BUILDINGS AND ASTM <br />SPECIFICATION A36. <br />B. STRUCTURAL STEEL SHALL BE WELDED IN COMPLIANCE WITH ANSI/AWS D1. <br />WELDERS SHALL BE CERTIFIED AS REQUIRED BY THE GOVERNING CODE <br />AUTHORITY. WELDING SHALL BE DONE BY THE ELECTRIC ARC PROCESS USING <br />APPROVED COATED RODS (E-70XX OR BETTER). SHOP WELDING SHALL BE <br />PERFORMED BY AN APPROVED FABRICATOR. <br />C. UNLESS A LARGER SIZE FILLET WELD IS INDICATED, PROVIDE MINIMUM SIZE OF <br />WELD PER AISC MANUAL TABLE J2.4. WELD LENGTHS INDICATED ARE THE NET <br />EFFECTIVE LENGTH REQUIRED. <br />D. FIELD CUTTING OR BURNING OF STRUCTURAL STEEL IS NOT PERMITTED WITHOUT <br />THE WRITTEN APPROVAL OF SGE. <br />E. REMOVE ALL BURRS AND SMOOTHEN ALL CORNERS TO 1/8" CHAMFER MINIMUM. <br />F. ALL NEW STEEL SHALL BE SANDBLASTED, THOROUGHLY CLEANED, AND PAINTED. <br />G. CORROSION PROTECTION: <br />a. PREP: SSPC SP 1 SOLVENT CLEAN AND SSPC 2 AND 3 HAND AND POWER TOOL <br />CLEAN. <br />b. PRIME: MACROPDXY 646-100 5-10 MILS <br />c. INTERMEDIATE: MACROPDXY 646-100 5-10 MILS <br />d. FINISH: HI SOLIDS POLY 2-3 MILS <br />9. ABBREVIATIONS <br />AHJ AUTHORITY HAVING JURISDICTION MAX MAXIMUM <br />BCD BOLT CIRCLE DIAMETER MIN MINIMUM <br />BTM BOTTOM MIR MIRROR <br />BW BOTH WAYS (N) NEW COMPONENT <br />CJ CONTROL JOINT NIC NOT IN THIS CONTRACT <br />CL CENTERLINE NOM NOMINAL <br />CLR CLEAR NTS NOT TO SCALE <br />CLSM CONTROLLED LOW -STRENGTH MATERIAL NWC NORMAL WEIGHT CONCRETE <br />CONT CONTINUOUS OC CENTER -TO -CENTER <br />CS CARBON STEEL OPP OPPOSITE <br />DIA DIAMETER PL PLATE <br />(E) EXISTING COMPONENT PSF POUNDS PER SQUARE FOOT <br />EA EACH PSI POUNDS PER SQUARE INCH <br />EJ EXPANSION JOINT REF FOR REFERENCE ONLY <br />EMB EMBEDMENT REINF REINFORCEMENT <br />FOR ENGINEER OF RECORD RPT REPORT <br />EXT EXTENSION SIM SIMILAR <br />(F) FUTURE COMPONENT SS STAINLESS STEEL <br />FC FILL CONNECTION STD STANDARD <br />GAL GALLON T&B TOP AND BOTTOM <br />GALV GALVANIZED TBD TO BE DETERMINED <br />HORIZ HORIZONTAL THK THICKNESS <br />L LITER TOC TOP OF CONCRETE <br />LAR LIQUID ARGON TOG TOP OF GRADE <br />LIN LIQUID NITROGEN TOS TOP OF STEEL <br />LNG LIQUEFIED NATURAL GAS TRANSV TRANSVERSE <br />LONGIT LONGITUDINAL TYP TYPICAL <br />LOX LIQUID OXYGEN LINO UNLESS NOTED OTHERWISE <br />LWR LENGTH OF REBAR WRAPPING VERT VERTICAL <br />THE SHOWN MINIMAL DISTANCES TO THE <br />PAD EDGES, ANCHOR EDGE DISTANCES, <br />NUMBER AND TYPE OF ANCHORS, AND <br />EQUIPMENT CLEARANCE DISTANCES <br />SHALL BE MAINTAINED. <br />FOR SITE PLAN, EQUIPMENT LAYOUT AND <br />ORIENTATION, AND OTHER INFORMATION <br />REFER TO PLAN BY OTHERS. <br />FOR ADDITIONAL INFORMATION, <br />REFER TO CONSTRUCTION NOTES, <br />PARTICULARLY, TO SECTIONS: <br />"SOILS" <br />"CONCRETE" <br />"REINFORCING STEEL" <br />"POST -INSTALLED ANCHORS" <br />"STRUCTURAL STEEL" <br />TYP <br />t <br />AS REQUIRED FOR <br />ALL SIDES EXPOSED <br />TO VEHICULAR <br />IMPACT <br />(N) SLIDING GATE <br />BY OTHERS NIC <br />(N) CHAIN LINK FENCE <br />(N) BOLLARD CL 29 BY OTHERS, NIC REF <br />70, NOTE 4E <br />------------------ ---- ------------------------------------------ --- <br />T-Yp- (N) VAPORIZER: <br />5-LWS-I2M-F <br />2 ANCHORAGE <br />PER SCHEDULE <br />(N) EMBEDDED PLATE FILL S2 <br />(3) TYP CONN B <br />LOCATION PER DETAIL _ <br />(N) TANK <br />1 9000-GALLON LIN <br />FIELD WELDED TO <br />52 EMBEDDED PLATES ❑ F <br />EJ @ CONCRETE a, <br />TYP TYP ONLY TYP <br />6 7 8 <br />S2 S2 S2 <br />iTANK CENTER <br />io <br />TYP <br />4 <br />i 0010'REF- <br />7' <br />2 <br />-------------------------------------------------------- - - - - - - - - - -- <br />(N) EQUIPMENT PAD-/ <br />30" THICK <br />4500 PSI NWC <br />REINFORCEMENT, B.W.: 8, 8' 8'-5" REF 4'-7" <br />TOP: #6@16" <br />BOT: #6@10" <br />(N) SWINGING GATE <br />BY OTHERS, NIC <br />(N) PAD AND (N) EQUIPMENT LAYOUT <br />PLAN, SCALE: 1" = 3'-0" <br />DESIGN <br />WEIGHT <br />SEISMIC DESIGN DATA <br />PARAMETER <br />HEIGHT <br />LRFD <br />EMPTY <br />FULL OR ICED <br />I <br />R <br />SEISMIC <br />BASE SHEAR <br />EQUIPMENT <br />FT <br />UNIT <br />KIPS <br />KIPS <br />COEFF. <br />KIPS <br />(N) TANK: 9,000-GAL LIN <br />48.70 <br />109.50 <br />27.83 <br />1 <br />2 <br />0.548 <br />60.00 <br />(N) VAPORIZER: 5-LWS-12M-F <br />2.40 <br />19.56 <br />23.09 <br />1 <br />2 <br />0.548 <br />10.72 <br />)�SEISM�ICDESIGN PARAMETER SCHEDULE <br />EPDXY: HILTI HIT-HY 200 PER [CC ESR-3187 <br />WASHERS <br />ANCHORAGE <br />(1) EACH ANCHOR <br />SPECIAL <br />ANCHOR ROD <br />INSPECTION <br />0 <br />EMB <br />EXT <br />STEEL <br /># PER <br /># PER <br />SIZE <br />THK. <br />HOLE 0, <br />MATERIAL <br />EQUIPMENT <br />REQUIRED <br />UNIT <br />IN <br />IN <br />IN <br />GRADE <br />LEG <br />UNIT <br />IN <br />IN <br />IN <br />(N) TANK: 9,000-GAL LIN <br />FIELD WELDED TO EMBEDDED PLATE <br />G <br />---------------------- <br />(N) VAPORIZER: 5-LWS-12M-F <br />1 <br />10 <br />6 <br />1 <br />4 <br />STANDARD GALV STEEL WASHER <br />GALV <br />REFER TO PLAN AND CONSTRUCTION NOTES FOR ADDITIONAL INFORMATION. <br />B ANCHORAGE SCHEDULE <br />U <br />w <br />r <br />BUILDING <br />CONTINUOUS <br />PERIODICALLY <br />REFERENCED <br />VERIFICATION AND INSPECTION TASK <br />DURING TASK <br />DURING TASK <br />STANDARD <br />REPORT <br />LISTED <br />LISTED <br />CONCRETE <br />1. INSPECTION OF ANCHORS <br />UPON <br />POST -INSTALLED IN HARDENED <br />X <br />ACI 318: 17.8.2 <br />INSPECTION <br />CONCRETE MEMBERS <br />2. INSPECTION OF CONCRETE <br />IBC: 1705.3 <br />CONSTRUCTION <br />EXCEPTION 2.3 <br />SOILS <br />1. VERIFY MATERIALS BELOW SHALLOW <br />FOUNDATIONS ARE ADEQUATE TO <br />ACHIEVE THE DESIGN BEARING <br />X <br />CAPACITY <br />2. VERIFY EXCAVATIONS ARE EXTENDED <br />TO PROPER DEPTH AND HAVE REACHED <br />X <br />- <br />PROPER MATERIAL <br />3. PERFORM CLASSIFICATION AND TESTING <br />PRIOR TO <br />OF FILL MATERIALS (EXCLUDING CLSM) <br />X <br />FOUNDATION <br />POUR <br />4. VERIFY USE OF PROPER MATERIALS, <br />DENSITIES AND LIFT THICKNESSES <br />DURING PLACEMENT AND COMPACTION <br />X <br />OF FILL (EXCLUDING CLSM) <br />5. PRIOR TO PLACEMENT OF FILL, OBSERVE <br />SUBGRADE AND VERIFY THAT SITE HAS <br />X <br />BEEN PREPARED PROPERLY <br />STEEL <br />AISC 360-10 <br />UPON <br />1. INSPECTION OF FIELD WELDING <br />X <br />TABLE: <br />INSPECTION <br />N5.4-1,2,3 <br />DEPUTY INSPECTORS ARE REQUIRED TO BE REGISTERED AND APPROVED BY THE AHJ <br />�^ SPECIAL INSPECTION SCHEDULE <br />v <br />CLIENT <br />CASCADE <br />- COFFEE - <br />Cascade Coffee <br />1525 75th St. SW, Suite 100, <br />Everett, WA 98203 <br />z <br />J <br />z <br />O <br />J <br />J t'� <br />Q w <br />1 0 <br />O " <br />00 <br />00 Q <br />QO (� W <br />a> 0� <br />u Q �# <br />O � w <br />0 Z �' <br />'ca U) <br />< I,- <br />V LO <br />ZL0 <br />O " <br />z <br />E- 4 <br />4 Imm <br />J <br />J <br />Q <br />i� <br />THESE PLANS WERE DEVELOPED RESTRICTIVELY <br />FOR USE ON THE STRUCTURES AND BY <br />PERSONS/COMPANY AS SPECIFIED IN THE TITLE <br />BLOCK. ANY OTHER USE (INCLUDING, BUT NOT <br />LIMITED TO, DISSEMINATION AND COPYING) OF <br />THESE PLANS OR ANY USE OF THE PLANS BY ANY <br />PARTY OR PARTIES OTHER THAN THE ONES <br />SPECIFIED IN THE TITLE BLOCK, ARE STRICTLY <br />PROHIBITED UNLESS UNDER A WRITTEN <br />PERMISSION BY SGE <br />S. GORDIN STRUCTURAL DESIGN <br />& ENGINEERING SERVICES (SGE), INC. <br />2081 Business Ctr Dr., Ste. 105, Irvine, CA 92612 <br />TEL. (949) 552-5244 FAX (949) 552-5243 <br />S TE ll <br />WASgl �O <br />June 29, 2021 <br />SGE JOB No. 521.053.396 <br />CASCADE COFFEE <br />REVISIONS <br />REV DATE DESCRIPTION tfr <br />PP'd <br />DATE: June 29, 2021 <br />DESIGNED BY EL <br />APPROVED BY VSG <br />TOTAL STRUCTURAL SHEETS - 2 <br />STRUCTURAL <br />LAYOUT, <br />NOTES & <br />SCHEDULES <br />smi <br />