Y <br />[4jilliIII lig qj <br />gnt <br />(a) <br />(b) <br />wheelchair <br />ambulatory <br />accessible <br />accessible water <br />water closets <br />closets <br />1525 <br />Figure 604.3.1 Size of Clearance at Water Closets <br />604.3.2 Overlap. The required clearance around the water closet shall be permitted to overlap <br />the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, <br />shelves, accessible routes, clear floor space and clearances required at other fixtures, and <br />the <br />turning space. No other fixtures or obstructions shall be located within the required water <br />closet clearonce. <br />604.4 Sects. The seat height of a water closet above the finish floor shall be 17 inches (430 <br />mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat. Sects <br />shall not be sprung to return to a lifted position. <br />604.5 Grab Bars. Grob bars for water closets shall comply with 609. Grob bars shall be <br />provided on the side wall closest to the water closet and on the rear wall. <br />604.5.1 Side Wall. The side wall grab bar shall be 42 inches (1065 mm) long minimum, <br />located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) <br />minimum from the rear wall. <br />492= <br />transfer <br />side <br />Figure 604.5.1 Side Wall Grab Bar at Water Closets Figure 804.5.2 Rear Wall Grab Bar at Water Closets <br />604.5.2 Rear Wall. The rear wofl grab bar shall be 36 inches (915 mm) long minimum and <br />extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and <br />24 inches (610 mm) minimum on the other side. <br />604.6 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush <br />controls shall comply with 309. Flush controls shall be located on the open side of the water <br />closet except in ambulatory accessible compartments complying with 604.8.2. <br />604.7 Dispensers. Toilet paper dispensers shall comply with 309,4 and shall be 7 inches (180 <br />mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the <br />centerline of the dispenser. The outlet of the dispenser shall be 15 inches (380 rrim) minimum <br />and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind <br />grab bars. Dispensers shall not be of a type that controls delivery or that does not allow <br />continuous paper flow. <br />Figure 604.7 Dispenser Outlet Location <br />604.8 Toilet Compartments, Wheelchair accessible toilet compartments shall meet the <br />requirements of 604.8.1 and 604.8.3. Compartments containing more than one plumbing fixture <br />shall comply with 603. Ambulatory accessible compartments shall comply with 604.8.2 and <br />604,8.3. <br />604.8.1 Wheelchair Accessible Compartments. Wheelchair accessible compartments shall comply <br />with 604.8.1. <br />604.8.1.1 Size. Wheelchair accessible compartments shall be 60 inches (1525 mm) wide <br />minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum <br />for wall hung water closets and 59 inches (1500 mm) deep minimum for floor mounted water <br />closets measured perpendicular to the rear wall. Wheelchair accessible compartments for <br />children's use shall be 50 inches (1525 mm) wide minimum measured perpendicular to the <br />side wall, and 59 inches (1500 mm) deep minimum for wall hung and floor mounted water <br />closets measured perpendicular to the rear wall, <br />1 (a525 <br />) <br />adult wall hung <br />water closet <br />alternate <br />door <br />location <br />X <br />M <br />E <br />1 525 <br />(b) <br />adult floor mounted water closet <br />and children's water closet <br />Figure 604.8.1.2 Wheelchair Accessible Toilet Compartment Doors <br />604.8.1.3 Approach. Compartments shall be arranged for left—hand or right—hand approach to <br />the water closet. <br />1 It's <br />EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than <br />62 inches (1575 mm) deep with a wall —hung water closet or 65 inches (1650 mm) deep with <br />a floor —mounted water closet. Toe clearance at the side partition is not required in a <br />compartment greater than 66 inches (1675 mm) wide. Toe clearance at the front partition is <br />not required in a compartment for children's use that is greater than 65 inches (1650 mm)deep <br />min 6 min <br />150 150 <br />9 min 12 min <br />gin AVI — — — 7/ 305 <br />(a) (b) <br />elevation elevation <br />adult children <br />plan <br />604.8.13 Grob Bor& Grob bars shall comply with 609. A side —wall grab bar complying with <br />604.5.1 shall be provided on both sides of the compartment. <br />QC <br />Figure 604.8.2 Ambulatory Accessible Toilet Compartment <br />1 T Jill <br />RIABRISM, I I MariWMTM%9�11- IM <br />604.9.3 Height. The height of water closets shall be 11 inches (280 mm) minimum and 17 <br />inches (430 mm) maximum measured to the top of the seat. Seats shall not be sprung to <br />return to a lifted position. <br />III lJIll IIIIIIIIIIIIIIIIIIII 1plijllllpl,111�11 !IIIIIIII <br />1111! 111111111 1 MMM� <br />a? I I <br />604.9.5 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated <br />flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) <br />maximum above the finish floor. Flush controls shall be located on the open side of the water <br />closet except in ambulatory accessible compartments complying with 604.8-2. <br />604.9.6 Dispensers. Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 <br />mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the <br />centerline of the dispenser. The outlet of the dispenser shall be 14 inches (355 mm) minimum <br />and 19 inches (485 mm) maximum above the finish floor. There shall be a clearance of 1 <br />1/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that <br />controls delivery or that does not allow continuous paper flow. <br />604.9.7 Toilet Compartments. Toilet compartments shall comply with 604-8. <br />605 Urinals <br />605.2 Height and Depth. Urinals shall be the stall —type or the wall —hung type with the rim 17 <br />inches (430 mm) maximum above the finish floor or ground. Urinols shall be 13 1/2 inches <br />(34.5 mm) deep minimum measured from the outer face of the urinal rim to the back of the <br />fixture. <br />131/2 min <br />131/2 min <br />345 <br />(a) (b) <br />wall hung type stall type <br />Figure 605.2 Height and Depth of urinals <br />605.3 Clear Floor Space. A clear floor or ground space complying with 305 positioned for <br />forward approach shall be provided, <br />605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush <br />controls shall comply with 309. <br />606 Lavatories and Sinks <br />606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward <br />approach, and knee and toe clearance complying with 306 shall be provided, <br />606.3 Height, Lavatories and sinks shall be installed with the front of the higher of the rim or <br />counter surface 34 inches (865 mm) maximum above the finish floor or ground. <br />606.4 Faucets. Controls for faucets shall comply with 309. Hand —operated metering faucets <br />shall remain open for 10 seconds minimum. <br />606.5 Exposed Pipes and Surfaces. Water supply and drain pipes under lavatories and sinks <br />shall be insulated or otherwise configured to protect against contact, There shall be no sharp <br />or abrasive surfaces under lavatories and sinks. <br />5325 <br />REGISTERED <br />ARCHITECT <br />TERRENCE C. <br />WATSON <br />STATE OF VVA1NGTON <br />E <br />0 <br />Jul <br />Z <br />(D <br />Lo <br />ICU <br />L) <br />> LO <br />< (0 , <br />0 <br />:F; (0 <br />U) <br />LID CN 0 <br />0 <br />ILL <br />I_) <br />D& <br />co: <br />U2 _QR) <br />0) M <br />< <br />LU <br />Cv <br />CN <br />00 <br />E <br />a) <br />2 <br />> <br />C <br />C) <br />N 4_9 <br />Cd 0 co <br />4-� <br />Eb <br />— C U) E <br />U) co 0 0 <br />06 7, (5 Fj 2 <br />co E o <br />00 <br />-5 <br />N> CD co C5 <br />cv) <br />Co Lij <br />File 2002A wdll <br />Drawn: 8-12-2020 <br />Revised: <br />Sheet <br />_< <br />ZL <br />Drawing scales are for 34"x22" paper <br />Verify with embedded graphic scarce <br />