My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6415 ELLIOTT WAY 2021-12-16
>
Address Records
>
ELLIOTT WAY
>
6415
>
6415 ELLIOTT WAY 2021-12-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2021 10:32:04 AM
Creation date
12/16/2021 10:31:04 AM
Metadata
Fields
Template:
Address Document
Street Name
ELLIOTT WAY
Street Number
6415
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
appear to indicate that the majority of the residence is being altered. Pleas clarify on the plansa �the <br /> specifics ope of the project. IRC R106.1.1. PO( ctt �/J�9 cp <br /> /< ? #s. <br /> 6.The plans contain exterior and interior elevations,please indicate and cut these elevations such that <br /> they can be referenced on the plan sheets. IRC R106.1.1. ,Q64.C1 <br /> 7. On the Basement Floor plan sheet, it appears that egress windows are proposed in order to meet the <br /> IRC 310 emergency egress and rescue opening provisions. Please indicate the dimensions locating <br /> these openings as well as provide window wells at these locations as this information appears to be <br /> missing fromthe drawings. IRC 310.2 and its subsections. /l'G <br /> 8. On the Main Floor plan sheet, (2) bedrooms are indicated. The drawings do not appear to provide <br /> emergency egress from these spaces. Please revise drawings as required. IRC 310 and its <br /> subsections. ,4dded <br /> 9. On the Basement and Main Floor plan sheets,exterior stairways are proposed to be constructed, <br /> please indicate on the plans and provide construction details for exterior landings at top and ottom <br /> of the stairwells as required as these appear to be missing from the plans. IRC 311.7.6. dpigif <br /> 10. On the Basement and Main Floor plan sheets,the proposed exterior stairwells appear to be missing <br /> handrails as well as details such as indicating rise and run for the stairways. The plans indicate a <br /> rise-run note,shown on the interior stairs, but there are no details defining the stairway`/geA � <br /> on the exterior stairways. Please clarify and revise drawings as required. IRC R311.7. i <br /> 11. On the Main Floor plan sheet,a deck is proposed to be replaced,please provide framing details for <br /> the deck framing addressing the vertical and lateral design loads,guar rails,and for exterior deck as <br /> these appear to be missing from the plans. IRCR507. 6;e <br /> 12. It is unclear on the plans if smoke alarms and carbon monoxide detectors are being installed or <br /> updated throughout in the residence per IRC R314.2.2 and R315.2.2, respectively. Please indicate <br /> and locate smoke alai s and carbop monoxide detectors in accordance with IRC R314 and R315 and <br /> their subsections. X adela <br /> 13. Please indicate the local exhaust systems used on the proposq bathroom/kitchen,laundry room as <br /> these appear to be missing from the plans.,IRC M1507.4. X Ul <br /> 14. Given the missing description of work, it is unclear the extent of scope of the WSEC requirements in <br /> the context of the proposed project. Please address the alterations as they apply to the provisions <br /> of the WSEC.WSEC R503. For example,given the current drawing set,the basement appears to be , <br /> an altered or new proposed habitable space,which may include updates to the building envelope, <br /> fenestration, HV C,etc. Please ccllari o pr� additional d ails on the p an . WSEC R53. <br /> 15. 0O ain oor ply n e a pears b a o osed i ati In of a x ez ��ad beam a d <br /> 4x6 posts to alter an existing bearing wall. The plan callout appears to have detail cut, but appears <br /> to be missing from the construction drawings. Please provide structural details addressing items <br /> such as the connections to the new framing(posts to beams, posts to foundation,etc.),the beam's <br /> connection to the existing framing as well as clarify if footings are provided for the proposed posts <br /> as it is unclear from the plans. Please also include information such as the wood species,connection <br /> EPage 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.